Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 35(8): 1154-1165.e6, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38729421

RESUMEN

PURPOSE: To report the first interim analysis of the STRIKE-PE study, evaluating the safety and effectiveness of computer assisted vaccum thrombectomy (CAVT) for the treatment of acute pulmonary embolism (PE). MATERIALS AND METHODS: This prospective, international, multicenter study will enroll 600 adult patients with acute PE of ≤14 days and a right ventricle (RV)-to-left ventricle (LV) ratio of ≥0.9 who receive first-line endovascular treatment with CAVT using the Indigo Aspiration System (Penumbra, Alameda, California). Primary endpoints are change in RV/LV ratio and incidence of composite major adverse events (MAEs) within 48 hours. Secondary endpoints include functional and quality-of-life (QoL) assessments. RESULTS: The first 150 consecutive patients were treated with 12F catheter CAVT. Mean age was 61.3 years, 54.7% were men, 94.7% presented with intermediate-risk PE, and 5.3% presented with high-risk PE. Median thrombectomy and procedure times were 33.5 minutes and 70.0 minutes, respectively, resulting in a mean reduction in systolic pulmonary artery pressure of 16.3% (P < .001). Mean RV/LV ratio decreased from 1.39 to 1.01 at 48 hours, a 25.7% reduction (P < .001). Four (2.7%) patients experienced a composite MAE within 48 hours. At 90-day follow-up, patients exhibited statistically significant improvements in the Borg dyspnea scale score and QoL measures, and the New York Heart Association class distribution returned to that reported before the index PE. CONCLUSIONS: Interim results from the STRIKE-PE study demonstrate a significant reduction in pulmonary artery pressure and RV/LV ratio, a median thrombectomy time of 33.5 minutes, a composite MAE rate of 2.7%, and significant improvements in 90-day functional and QoL outcomes.


Asunto(s)
Embolia Pulmonar , Calidad de Vida , Trombectomía , Humanos , Femenino , Masculino , Embolia Pulmonar/fisiopatología , Embolia Pulmonar/terapia , Embolia Pulmonar/cirugía , Persona de Mediana Edad , Trombectomía/efectos adversos , Trombectomía/instrumentación , Resultado del Tratamiento , Estudios Prospectivos , Anciano , Factores de Tiempo , Recuperación de la Función , Adulto , Vacio , Estado Funcional , Factores de Riesgo
2.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38460161

RESUMEN

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Asunto(s)
Reestenosis Coronaria , Infarto del Miocardio , Femenino , Humanos , Anciano , Paclitaxel , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Stents , Resultado del Tratamiento , Muerte
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA