Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Rev Sci Instrum ; 93(11): 113546, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36461451

RESUMEN

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny-Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.

2.
Phys Rev Lett ; 107(21): 215003, 2011 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-22181890

RESUMEN

Observations in the ASDEX Upgrade tokamak show a correlation between the gradient of the intrinsic toroidal rotation profile and the logarithmic gradient of the electron density profile. The intrinsic toroidal rotation in the center of the plasma reverses from co- to countercurrent when the logarithmic density gradients are large, and the turbulence is either dominated by trapped electron modes or is at the transition between ion temperature gradient and trapped electron modes. A study based on local gyrokinetic calculations suggests that the dominant trend in the observations can be explained by the combination of residual stresses produced by E × B and profile shearing mechanisms.

3.
Rev Sci Instrum ; 92(10): 103501, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34717377

RESUMEN

We introduce a new correlation analysis technique for thermal helium beam (THB) diagnostics. Instead of directly evaluating line ratios from fluctuating time series, we apply arithmetic operations to all available He I lines and construct time series with desired dependencies on the plasma parameters. By cross-correlating those quantities and by evaluating ensemble averages, uncorrelated noise contributions can be removed. Through the synthetic data analysis, we demonstrate that the proposed analysis technique is capable of providing the power spectral densities of meaningful plasma parameters, such as the electron density and the electron temperature, even under low-photon-count conditions. In addition, we have applied this analysis technique to the experimental THB data obtained at the ASDEX Upgrade tokamak and successfully resolved the electron density and temperature fluctuations up to 90 kHz in a reactor relevant high power scenario.

4.
Rev Sci Instrum ; 90(12): 123101, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31893862

RESUMEN

A multichannel spectroscopic diagnostic based on the Stark effect on helium lines was developed and implemented in IShTAR (Ion Cyclotron Sheath Test ARrangement) to measure the spatial distribution of electric fields across the radio frequency sheaths of the ion cyclotron antenna. Direct measurements of the DC electric fields in the antenna sheaths are an important missing component in understanding the antenna-plasma edge interactions in magnetically confined fusion plasmas since they will be used to benchmark theoretical models against real antenna operation. Along with the high-resolution Czerny-Turner monochromator and a detector with an intensifier, the hardware relies on the 2 chained set of linear-to-linear fiber bundles that provide seven optical channels capable of resolving an 8.4 mm region in the vicinity of the antenna's box. The diagnostic is supported with local helium gas puff, enabling it to operate in nonhelium plasmas. Spatially resolved electric field was measured for two discharge configurations, one with and one without the ICRF antenna. The results show a clear difference in the shape of the DC electric field's spatial profile for the two cases studied, with the elevated values when the ICRF antenna was operating. This demonstrates the ability of the diagnostic to measure even small relative changes in the intensity of the electric field.

5.
Rev Sci Instrum ; 89(10): 10D115, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399884

RESUMEN

IShTAR, Ion cyclotron Sheath Test ARrangement, is a linear device dedicated to the investigation of the edge plasma-ICRF (Ion Cyclotron Range of Frequencies) antenna interactions in tokamak edge-like conditions and serves as a platform for a diagnostic development for measuring the electric fields in the vicinity of ICRF antennas. We present here our progress in the development of an optical emission spectroscopy method for measuring the electric fields which concentrates on the changes in the helium spectral line profiles introduced by the external electrical field, i.e., the Stark effect. To be able to fully control the operating parameters, at the first stage of the study, the measurements are conducted on a planar electrode installed in the centre of the plasma column in IShTAR's helicon plasma source. At the second stage, the measurements are performed in the vicinity of IShTAR's ICRF antenna.

6.
Rev Sci Instrum ; 89(10): 10D102, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399953

RESUMEN

The thermal helium beam edge diagnostic has recently been upgraded at the ASDEX Upgrade (AUG) tokamak experiment. Line ratio spectroscopy on neutral helium is a valuable tool for simultaneous determination of the electron temperature and density of plasmas. The diagnostic now offers a temporal resolution of 900 kHz with a spatial resolution of up to 3 mm at 32 lines of sight (LOS) simultaneously. The LOS covers a radial region of 8.5 cm, starting at the limiter radius and reaching into the confined region beyond the separatrix. Two components are of particular importance for the aforementioned hardware improvements. The first is the optical head, which collects the light from the experiment. Equipped with an innovative clamping system for optical fiber ends, an arbitrary distribution pattern of LOS can be achieved to gain radial and poloidal profiles. The second major development is a new polychromator system that measures the intensity of the 587 nm, 667 nm, 706 nm, and 728 nm helium lines simultaneously for 32 channels with filter-photomultiplier tube arrays. Thus, the thermal helium beam diagnostic supplements the AUG edge diagnostics, offering fast and spatially highly resolved electron temperature and density profile measurements that cover the plasma edge and scrape-off layer region. Plasma fluctuations, edge localized modes, filaments, and other turbulent structures are resolved, allowing analysis of their frequency and localization or their propagation velocity.

7.
Rev Sci Instrum ; 88(4): 043103, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28456224

RESUMEN

In this work, a new type of high through-put Czerny-Turner spectrometer has been developed which allows us to acquire multiple channels simultaneously with a repetition time on the order of 10 µs at different wavelengths. The spectrometer has been coupled to the edge charge exchange recombination system at ASDEX Upgrade which has been recently refurbished with new lines of sight. Construction features, calibration methods, and initial measurements obtained with the new setup will be presented.

8.
Rev Sci Instrum ; 88(7): 073508, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28764552

RESUMEN

A new core charge exchange recombination spectroscopy diagnostic has been installed in the ASDEX Upgrade tokamak that is capable of measuring the impurity ion temperature, toroidal rotation, and density on both the low field side (LFS) and high field side (HFS) of the plasma. The new system features 48 lines-of-sight (LOS) with a radial resolution that varies from ±2 cm on the LFS down to ±0.75 cm on the HFS and has sufficient signal to run routinely at 10 ms and for special circumstances down to 2.5 ms integration time. The LFS-HFS ion temperature profiles provide an additional constraint on the magnetic equilibrium reconstruction, and the toroidal rotation frequency profiles are of sufficiently high quality that information on the poloidal velocity can be extracted from the LFS-HFS asymmetry. The diagnostic LOS are coupled to two flexible-wavelength spectrometers such that complete LFS-HFS profiles from two separate impurities can be imaged simultaneously, albeit with reduced radial coverage. More frequently, the systems measure the same impurity providing very detailed information on the chosen species. Care has been taken to calibrate the systems as accurately as possible and to include in the data analysis any effects that could lead to spurious temperatures or rotations.

9.
Rev Sci Instrum ; 87(11): 11E528, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910416

RESUMEN

A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line Dα. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

10.
J Immunol Methods ; 144(2): 175-83, 1991 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-1960414

RESUMEN

Monoclonal antibodies (Mabs) directed against cell surface determinants and conjugated to fluochromes, radionuclids or drugs are of increasing importance in cell and tumor biology as well as in clinical oncology. Many of the applications of Mab require precise and quantitative information regarding the molecular interactions of labeled antibody with the respective antigen expressed on the cell surface. These interactions are characterized by the association rate constant (ka), the dissociation rate constant (kd) and the antibody affinity constant (K). The immunoreactive fraction (IRF) of the labeled antibody molecules directly influences these parameters. IRF is usually reduced below 100% by antibody purification and labeling procedures and, in case of radiolabeled antibodies, by radiation damage during antibody storage. Besides the calculation of kinetic parameters, IRF should, therefore, be determined for the quality control of any antibody preparation before experimental or clinical application. Commonly used methods for measuring IRF are based on radioimmunoassays (RIA) on intact cells performed under antigen excess. However, especially with Mabs directed against cell surface antigens expressed in small numbers per cell and for displaying low affinity constants, these assays often give unsatisfactory results. We have, therefore, established a method which permits us to determine IRF, ka, kd and K for an 125I-labeled Mab with precision even in the absence of antigen excess.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Animales , Afinidad de Anticuerpos , Sitios de Unión de Anticuerpos , Línea Celular , Radioisótopos de Yodo , Cinética , Radioinmunoensayo , Ratas
11.
J Neurol Sci ; 144(1-2): 59-63, 1996 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-8994104

RESUMEN

Fifteen persons from two consecutive generations of one family affected with facio-scapulo-humeral muscular dystrophy (FSHD) were clinically and neurophysiologically examined. Diagnostic muscle biopsies were obtained from two members. Linkage analysis showed that all four affected members of the family inherit the same 4q35 haplotype giving a lod score of z = +1.44. Six family members were examined by ECG at rest and under stress, by two-dimensional echocardiography, and by cardiac Thallium-201 single-photon-emission computed tomography (Tl-201-SPECT) under dobutamine stress and at rest. Abnormal reduced Tl-201 uptake in cardiac SPECT was only found in the affected members of the family. Therefore we suggest that cardiac Tl-201-SPECT abnormalities in FSHD reflect cardiomyogenic changes in this type of muscular disease.


Asunto(s)
Genes Dominantes , Corazón/diagnóstico por imagen , Distrofias Musculares/genética , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Biopsia , Cardiotónicos , Dobutamina , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculos/patología , Distrofias Musculares/diagnóstico por imagen , Distrofias Musculares/patología , Linaje , Radioisótopos de Talio
12.
J Neurol Sci ; 121(1): 74-8, 1994 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-7510788

RESUMEN

Flow cytometry (FC) is an useful tool for the analysis of subpopulations in complex cell suspensions. When applying this method to the cerebrospinal fluid (CSF), some characteristic properties of this cell type must be taken into consideration: there are only few cells which decay rapidly in their native medium and during centrifugation. One aim of the immunostaining procedure preceding flow cytometric analysis must be to minimize cell loss in order to get an undistorted picture of 'true' CSF cell populations. Consequently, morphological flow cytometric plots of high resolution are an indispensable precondition for reliable determination of subpopulations defined by monoclonal antibody (Mab) binding. We describe a standardized protocol for the flow cytometric examination of CSF cells which minimizes undesired cell loss. By the use of a 'quality control' the extent of cell loss could be monitored. Examples of morphological flow cytometric plots are given. The subsequent determination of Mab binding subpopulations is critical when fluorescence intensities of antigen positive and negative cells are non-disjunct. A statistical test was developed for these cases often seen when cell surface determinants are expressed at low levels only.


Asunto(s)
Líquido Cefalorraquídeo/citología , Citometría de Flujo/métodos , Anticuerpos Monoclonales , Antígenos CD/análisis , Centrifugación , Femenino , Fluoresceína-5-Isotiocianato , Humanos , Técnicas Inmunológicas , Recuento de Leucocitos , Linfocitos/inmunología , Masculino , Control de Calidad , Coloración y Etiquetado , Factores de Tiempo
13.
Rev Sci Instrum ; 84(9): 093505, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24094058

RESUMEN

A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique.

14.
Rev Sci Instrum ; 84(11): 113502, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24295435

RESUMEN

A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as D2-molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.

15.
Rev Sci Instrum ; 83(10): 103501, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23130787

RESUMEN

The charge exchange recombination spectroscopy (CXRS) diagnostics at ASDEX Upgrade (AUG) have been upgraded and extended to provide high-resolution measurements of impurity ion temperature, density, and rotation profiles. The existing core toroidal CXRS diagnostic has been refurbished to increase the level of signal, thus enabling shorter exposure times down to 3.5 ms. Additional lines of sight provide more detailed profiles and enable simultaneous measurements of multiple impurities. In addition, a new CXRS system has been installed, which allows for the measurement of poloidal impurity ion rotation in the plasma edge with high temporal (1.9 ms) and spatial resolution (down to 5 mm). A new wavelength correction method has been implemented to perform in situ wavelength calibrations on a shot-to-shot basis. Absolute measurements of the poloidal impurity ion rotation with uncertainties smaller than 1.5 km/s have been obtained. Comparison of all the CXRS measurements provides a consistency check of the diagnostics and good agreement has been found for all of the CXRS systems.

20.
Phys Rev Lett ; 102(2): 025001, 2009 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-19257281

RESUMEN

The toroidal rotation of H-mode plasmas in ASDEX Upgrade is studied in the outermost 5 cm of the confined plasma. The projection of the rotation velocity along the line of sight (approximately toroidal) is measured using charge exchange recombination spectroscopy, with a radial resolution of up to 3 mm and a temporal resolution of 1.9 ms. At about 1 cm inside the separatrix the rotation exhibits a local minimum. From there, the rotation in codirection increases towards the plasma center and towards the separatrix. The latter increase is the focus of this work. It is situated in the region of the edge transport barrier and amounts to 10-20 km/s. It is observed for D+, He2+, B5+, and C6+. The described rotation feature at the edge is not visible during an ELM crash and is probably connected to the occurrence of steep gradients in this plasma region.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA