Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Lancet Neurol ; 4(11): 727-34, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16239179

RESUMEN

BACKGROUND: In patients with acute stroke, rapid intervention is crucial to maximise early treatment benefits. Stroke patients commonly have their first contact with medical staff in the emergency room (ER). We designed and validated a stroke recognition tool-the Recognition of Stroke in the Emergency Room (ROSIER) scale-for use by ER physicians. METHODS: We prospectively collected data for 1 year (development phase) on the clinical characteristics of patients with suspected acute stroke who were admitted to hospital from the ER. We used logistic regression analysis and clinical reasoning to develop a stroke recognition instrument for application in this setting. Patients with suspected transient ischaemic attack (TIA) with no symptoms or signs when assessed in the ER were excluded from the analysis. The instrument was assessed using the baseline 1-year dataset and then prospectively validated in a new cohort of ER patients admitted over a 9-month period. FINDINGS: In the development phase, 343 suspected stroke patients were assessed (159 stroke, 167 non-stroke, 32 with TIA [17 with symptoms when seen in ER]). Common stroke mimics were seizures (23%), syncope (23%), and sepsis (10%). A seven-item (total score from -2 to +5) stroke recognition instrument was constructed on the basis of clinical history (loss of consciousness, convulsive fits) and neurological signs (face, arm, or leg weakness, speech disturbance, visual field defect). When internally validated at a cut-off score greater than zero, the instrument showed a diagnostic sensitivity of 92%, specificity of 86%, positive predictive value (PPV) of 88%, and negative predictive value (NPV) of 91%. Prospective validation in 173 consecutive suspected stroke referrals (88 stroke, 59 non-stroke, 26 with TIA [13 with symptoms]) showed sensitivity of 93% (95% CI 89-97), specificity 83% (77-89), PPV 90% (85-95), and NPV 88% (83-93). The ROSIER scale had greater sensitivity than existing stroke recognition instruments in this population. INTERPRETATION: The ROSIER scale was effective in the initial differentiation of acute stroke from stroke mimics in the ER. Introduction of the instrument improved the appropriateness of referrals to the stroke team.


Asunto(s)
Servicios Médicos de Urgencia , Servicio de Urgencia en Hospital , Accidente Cerebrovascular/diagnóstico , Anciano , Estudios de Cohortes , Bases de Datos Factuales , Diagnóstico Diferencial , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Humanos , Ataque Isquémico Transitorio/diagnóstico , Modelos Logísticos , Masculino , Trastornos del Movimiento/diagnóstico , Trastornos del Movimiento/etiología , Estudios Prospectivos , Reproducibilidad de los Resultados , Accidente Cerebrovascular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA