Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Microbiol ; 22(1): 119, 2022 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-35501697

RESUMEN

BACKGROUND: 16S rDNA-PCR for the identification of a bacterial species is an established method. However, the DNA extraction reagents as well as the PCR reagents may contain residual bacterial DNA, which consequently generates false-positive PCR results. Additionally, previously used methods are frequently time-consuming. Here, we describe the results obtained with a new technology that uses DNA-free reagents for automated DNA extraction and subsequent real time PCR using sterile clinical specimens. RESULTS: In total, we compared 803 clinical specimens using real time PCR and culturing. The clinical specimens were mainly of orthopedic origin received at our diagnostic laboratory. In 595 (74.1%) samples, the results were concordant negative, and in 102 (12.7%) the results were concordant positive. A total of 170 (21.2%) clinical specimens were PCR-positive, of which 62 (36.5% from PCR positive, 7.7% in total) gave an additional benefit to the patient since only the PCR result was positive. Many of these 62 positive specimens were strongly positive based on crossingpoint values (54% < Cp 30), and these 62 positive clinical specimens were diagnosed as medically relevant as well. Thirty-eight (4.2%) clinical specimens were culture-positive (25 of them were only enrichment culture positive) but PCR-negative, mainly for S. epidermidis, S. aureus and C. acnes. The turnaround times for negative specimens were 4 hours (automated DNA extraction and real time PCR) and 1 working day for positive specimens (including Sanger sequencing). Melting-curve analysis of SYBR Green-PCR enables the differentiation of specific and unspecific PCR products. Using Ripseq, even mixed infections of 2 bacterial species could be resolved. CONCLUSIONS: For endocarditis cases, the added benefit of PCR is obvious. The crucial innovations of the technology enable timely reporting of explicit reliable results for adequate treatment of patients. Clinical specimens with truly PCR-positive but culture-negative results represent an additional benefit for patients. Very few results at the detection limit still have to be critically examined.


Asunto(s)
Bacterias , Staphylococcus aureus , Bacterias/genética , ADN Bacteriano/análisis , ADN Bacteriano/genética , ADN Ribosómico/genética , Humanos , Indicadores y Reactivos , Reacción en Cadena en Tiempo Real de la Polimerasa , Staphylococcus aureus/genética
2.
Ann Clin Microbiol Antimicrob ; 20(1): 52, 2021 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-34362393

RESUMEN

BACKGROUND: The resistance of Neisseria gonorrhoeae to ceftriaxone is unusual in Switzerland. The underlying genotype responsible for resistance is suspected to be novel. Generally, resistance in Neisseria gonorrhoeae (Ng) involves a comprehensive set of genes with many different mutations leading to resistance to different ß-lactams and fluoroquinolones. CASE PRESENTATION: A patient had a positive result from specific PCR for Ng. We routinely culture all clinical specimens with a positive NG-PCR. In this particular case, we isolated a strain with resistance to ceftriaxone in Switzerland. A total of seven different genes (penA, ponA, porinB, mtr, gyrA, parC, 23S rRNA gene) in this strain were partially sequenced for comparison with phenotypic susceptibility testing. Interestingly, two different mutations in the porinB gene were observed, and data on this gene are limited. Information on the identified allele type of the penA gene is very limited as well. Three different mutations of parC and gyrA that correlate with ciprofloxacin resistance were found. The combination of ceftriaxone and ciprofloxacin resistance makes an appropriate treatment difficult to obtain due to multidrug resistance. CONCLUSION: The combined results for all genes show the appearance of new mutations in central Europe either due to worldwide spread or the emergence of new genetic combinations of mutations.


Asunto(s)
Antibacterianos/farmacología , Proteínas Bacterianas/genética , Ceftriaxona/farmacología , Ciprofloxacina/farmacología , Gonorrea/tratamiento farmacológico , Neisseria gonorrhoeae/efectos de los fármacos , Neisseria gonorrhoeae/aislamiento & purificación , Adulto , ADN Bacteriano/genética , Gonorrea/diagnóstico , Gonorrea/microbiología , Humanos , Masculino , Pruebas de Sensibilidad Microbiana , Neisseria gonorrhoeae/genética , Fenotipo , Reacción en Cadena de la Polimerasa , Suiza
3.
Clin Chem Lab Med ; 58(12): 2131-2140, 2020 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-32866113

RESUMEN

Objectives The sensitivity of molecular and serological methods for COVID-19 testing in an epidemiological setting is not well described. The aim of the study was to determine the frequency of negative RT-PCR results at first clinical presentation as well as negative serological results after a follow-up of at least 3 weeks. Methods Among all patients seen for suspected COVID-19 in Liechtenstein (n=1921), we included initially RT-PCR positive index patients (n=85) as well as initially RT-PCR negative (n=66) for follow-up with SARS-CoV-2 antibody testing. Antibodies were detected with seven different commercially available immunoassays. Frequencies of negative RT-PCR and serology results in individuals with COVID-19 were determined and compared to those observed in a validation cohort of Swiss patients (n=211). Results Among COVID-19 patients in Liechtenstein, false-negative RT-PCR at initial presentation was seen in 18% (12/66), whereas negative serology in COVID-19 patients was 4% (3/85). The validation cohort showed similar frequencies: 2/66 (3%) for negative serology, and 16/155 (10%) for false negative RT-PCR. COVID-19 patients with negative follow-up serology tended to have a longer disease duration (p=0.05) and more clinical symptoms than other patients with COVID-19 (p<0.05). The antibody titer from quantitative immunoassays was positively associated with the number of disease symptoms and disease duration (p<0.001). Conclusions RT-PCR at initial presentation in patients with suspected COVID-19 can miss infected patients. Antibody titers of SARS-CoV-2 assays are linked to the number of disease symptoms and the duration of disease. One in 25 patients with RT-PCR-positive COVID-19 does not develop antibodies detectable with frequently employed and commercially available immunoassays.


Asunto(s)
Betacoronavirus/genética , Betacoronavirus/inmunología , Reacción en Cadena en Tiempo Real de la Polimerasa , Pruebas Serológicas , Adulto , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Persona de Mediana Edad , SARS-CoV-2 , Factores de Tiempo , Adulto Joven
4.
Dis Markers ; 2021: 8810196, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33532006

RESUMEN

Several tests based on chemiluminescence immunoassay techniques have become available to test for SARS-CoV-2 antibodies. There is currently insufficient data on serology assay performance beyond 35 days after symptoms onset. We aimed to evaluate SARS-CoV-2 antibody tests on three widely used platforms. A chemiluminescent microparticle immunoassay (CMIA; Abbott Diagnostics, USA), a luminescence immunoassay (LIA; Diasorin, Italy), and an electrochemiluminescence immunoassay (ECLIA; Roche Diagnostics, Switzerland) were investigated. In a multigroup study, sensitivity was assessed in a group of participants with confirmed SARS-CoV-2 (n = 145), whereas specificity was determined in two groups of participants without evidence of COVID-19 (i.e., healthy blood donors, n = 191, and healthcare workers, n = 1002). Receiver operating characteristic (ROC) curves, multilevel likelihood ratios (LR), and positive (PPV) and negative (NPV) predictive values were characterized. Finally, analytical specificity was characterized in samples with evidence of the Epstein-Barr virus (EBV) (n = 9), cytomegalovirus (CMV) (n = 7), and endemic common-cold coronavirus infections (n = 12) taken prior to the current SARS-CoV-2 pandemic. The diagnostic accuracy was comparable in all three assays (AUC 0.98). Using the manufacturers' cut-offs, the sensitivities were 90%, 95% confidence interval [84,94] (LIA), 93% [88,96] (CMIA), and 96% [91,98] (ECLIA). The specificities were 99.5% [98.9,99.8] (CMIA), 99.7% [99.3,99.9] (LIA), and 99.9% [99.5,99.98] (ECLIA). The LR at half of the manufacturers' cut-offs were 60 (CMIA), 82 (LIA), and 575 (ECLIA) for positive and 0.043 (CMIA) and 0.035 (LIA, ECLIA) for negative results. ECLIA had higher PPV at low pretest probabilities than CMIA and LIA. No interference with EBV or CMV infection was observed, whereas endemic coronavirus in some cases provided signals in LIA and/or CMIA. Although the diagnostic accuracy of the three investigated assays is comparable, their performance in low-prevalence settings is different. Introducing gray zones at half of the manufacturers' cut-offs is suggested, especially for orthogonal testing approaches that use a second assay for confirmation.


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/diagnóstico , Mediciones Luminiscentes/métodos , SARS-CoV-2/inmunología , Adulto , Prueba de COVID-19 , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
5.
Eur J Pediatr ; 169(3): 319-25, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19649782

RESUMEN

Rotavirus gastroenteritis (RV GE) is a leading cause of diarrhoea in young children. The purpose of this epidemiological surveillance was to measure the disease burden of RV GE among children <5 years of age in two regions of Switzerland, Geneva and Lucerne. One hospital and four paediatricians participated per region. The surveillance lasted from December 2006 to June 2007. The population denominator for calculation of the RV GE incidence rate was the average of the overall study population <5 years of age under surveillance during the surveillance period. At the study sites, 513 children with GE were presented. Stool sample was collected and examined in 341 cases, of which 130 were RV positive (38.1%). Informed consent to participate in the study was obtained for 113 RV positive subjects. The overall RV GE incidence rate was 0.97% in Lucerne [lower incidence interval (LCI), 0.71%; upper incidence interval (UCI), 1.2%] compared with 0.65 and in Geneva (LCI, 0.50%; UCI, 0.81%). Disease severity assessments using the Vescari score showed that the RV GE episodes were more severe in Lucerne than in Geneva (14.05 +/- 3.05 vs 12.85 +/- 2.87), which was confirmed by a higher hospitalisation rate in Lucerne at the study visit (82.9% vs 23.6%). More children had fever in Geneva than in Lucerne (42.9% vs 26.8%), and more children were hospitalised during the follow-up period in Geneva than in Lucerne (14.5% vs 2.5%). Genotyping of RV positive stool samples revealed that both G1 and P8 were the most prevalent types in both regions. There was a statistically significant difference in the distribution frequency of G1 between the two regions (p = 0.039). Assessment of health economic data confirmed the economic burden of RV GE episodes. In conclusion, RV GE episodes are a health burden as well as an economic burden also for the children in a developed country such as Switzerland.


Asunto(s)
Costo de Enfermedad , Gastroenteritis/epidemiología , Infecciones por Rotavirus/epidemiología , Preescolar , Gastroenteritis/economía , Genotipo , Humanos , Lactante , Recién Nacido , Rotavirus/genética , Infecciones por Rotavirus/economía , Suiza/epidemiología
6.
Front Cell Infect Microbiol ; 10: 596371, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33392106

RESUMEN

Helicobacter pylori antibiotic resistance is increasing worldwide, emphasizing the urgent need for more rapid resistance detection prior to the administration of H. pylori eradication regimens. Macrolides and fluoroquinolones are widely used to treat H. pylori. In this study, we aimed to compare the diagnostic performance of A) 23SrDNA qPCR (with melting curve analysis) and an in-house developed gyrA qPCR followed by Sanger sequencing with a commercial IVD-marked hybridization probe assay (for 23SrDNA and gyrA) using 142 gastric biopsies (skipping culturing) and B) the same two qPCR for 23SrDNA and gyrA (including Sanger sequencing) with whole-genome sequencing (WGS) and phenotypic characterization of clarithromycin and levofloxacin resistance using 76 cultured isolates. The sensitivity of both qPCRs was 100% compared to that of the commercial IVD-marked hybridization probe assay for the detection of H. pylori in gastric biopsies (without resistance testing). The specificity of the qPCR gyrA followed by Sanger sequencing was 100%, indicating that the best sequence identity was always H. pylori. The results show good agreement between molecular tests, especially between qPCR (inclusive Sanger sequencing) and WGS. Discrepancies (concerning mutated or wild type of positive H. pylori gastric biopsies) were observed between Sanger sequencing of the gyrA gene and the corresponding commercial hybridization probe assay, mostly because the high sequence diversity of the gyrA gene even at positions adjacent to the relevant codons of 87 and 91 interfered with obtaining correct results from the hybridization probe assay. Interestingly, we found several mixed sequences, indicating mixed populations in the gastric biopsies (direct detection without culturing). There was a high percentage of both levofloxacin and clarithromycin resistance in gastric biopsies (both between 22% and 29%, direct detection in gastric biopsies). Therefore, we recommend analyzing both targets in parallel. We confirmed that phenotypic resistance is highly correlated with the associated mutations. We concluded that the two qPCR followed by Sanger sequencing of the gyrA gene is a fast, cost-effective and comprehensive method for resistance testing of H. pylori directly in gastric biopsies.


Asunto(s)
Infecciones por Helicobacter , Helicobacter pylori , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Claritromicina/farmacología , Farmacorresistencia Bacteriana/genética , Infecciones por Helicobacter/diagnóstico , Infecciones por Helicobacter/tratamiento farmacológico , Helicobacter pylori/genética , Humanos , Levofloxacino/farmacología , Pruebas de Sensibilidad Microbiana
7.
Diagnostics (Basel) ; 10(8)2020 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-32823852

RESUMEN

While lateral flow test formats can be utilized with whole blood and low sample volumes, their diagnostic characteristics are inferior to immunoassays based on chemiluminescence immunoassay (CLIA) or enzyme-linked immunosorbent assay (ELISA) technology. CLIAs and ELISAs can be automated to a high degree but commonly require larger serum or plasma volumes for sample processing. We addressed the suitability of EDTA-anticoagulated whole blood as an alternative sample material for antibody testing against SARS-CoV-2 by electro-CLIA (ECLIA; Roche, Rotkreuz, Switzerland) and ELISA (IgG and IgA; Euroimmun, Germany). Simultaneously drawn venous serum and EDTA-anticoagulated whole blood samples from 223 individuals were included. Correction of the whole blood results for hematocrit led to a good agreement with the serum results for weakly to moderately positive antibody signals. In receiver-operating characteristic curve analysis, all three assays displayed comparable diagnostic accuracy (area under the curve (AUC)) using corrected whole blood and serum (AUCs: 0.97 for ECLIA and IgG ELISA; 0.84 for IgA ELISA). In conclusion, our results suggest that the investigated assays can reliably detect antibodies against SARS-CoV-2 in hemolyzed whole blood anticoagulated with EDTA. Correction of these results for hematocrit is suggested. This study demonstrates that the automated processing of whole blood for identification of SARS-CoV-2 antibodies with common ECLIA and ELISA methods is accurate and feasible.

8.
Biomed Res Int ; 2020: 9878453, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33224987

RESUMEN

Knowledge of the sensitivities of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody tests beyond 35 days after the clinical onset of COVID-19 is insufficient. We aimed to describe positivity rate of SARS-CoV-2 assays employing three different measurement principles over a prolonged period. Two hundred sixty-eight samples from 180 symptomatic patients with COVID-19 and a reverse transcription polymerase chain reaction (RT-PCR) test followed by serological investigation of SARS-CoV-2 antibodies were included. We conducted three chemiluminescence (including electrochemiluminescence assay (ECLIA)), four enzyme-linked immunosorbent assay (ELISA), and one lateral flow immunoassay (LFIA) test formats. Positivity rates, as well as positive (PPVs) and negative predictive values (NPVs), were calculated for each week after the first clinical presentation for COVID-19. Furthermore, combinations of tests were assessed within an orthogonal testing approach employing two independent assays and predictive values were calculated. Heat maps were constructed to graphically illustrate operational test characteristics. During a follow-up period of more than 9 weeks, chemiluminescence assays and one ELISA IgG test showed stable positivity rates after the third week. With the exception of ECLIA, the PPVs of the other chemiluminescence assays were ≥95% for COVID-19 only after the second week. ELISA and LFIA had somewhat lower PPVs. IgM exhibited insufficient predictive characteristics. An orthogonal testing approach provided PPVs ≥ 95% for patients with a moderate pretest probability (e.g., symptomatic patients), even for tests with a low single test performance. After the second week, NPVs of all but IgM assays were ≥95% for patients with low to moderate pretest probability. The confirmation of negative results using an orthogonal algorithm with another assay provided lower NPVs than the single assays. When interpreting results from SARS-CoV-2 tests, the pretest probability, time of blood draw, and assay characteristics must be carefully considered. An orthogonal testing approach increases the accuracy of positive, but not negative, predictions.


Asunto(s)
Anticuerpos Antivirales/inmunología , Betacoronavirus/inmunología , Infecciones por Coronavirus/inmunología , Neumonía Viral/inmunología , Anticuerpos Antivirales/sangre , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Humanos , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/sangre , Neumonía Viral/diagnóstico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2 , Sensibilidad y Especificidad , Pruebas Serológicas/métodos
9.
FEMS Microbiol Ecol ; 61(2): 384-97, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17651138

RESUMEN

District heating systems (DHS) are extreme aqueous environments characterized by high temperatures, high pH (9.5-10.0), and low nutrient availability. Culture-independent and culture-dependent techniques showed that DHS may nevertheless harbour geno- and phenotypically diverse bacterial biofilm communities. Approximately 50% of the cells in biofilms growing on mild steel coupons in rotortorque reactors connected to the return line (40 degrees C) of a Danish DHS were detectable by FISH analysis and thus were probably metabolically active. A bacterial 16S rRNA gene clone library generated from the biofilms was dominated by proteobacterial phylotypes (closely related to known aerobic species) and by phylotypes affiliated to the anaerobic class Clostridia. Anoxic enrichment cultures derived from biofilms primarily contained 16S rRNA gene and dsrAB (encoding major subunits of dissimilatory sulfite reductase) phylotypes affiliated to the latter class. Alkalitolerant and neutrophilic anaerobic bacteria were isolated from the DHS, including novel Gram-positive and deltaproteobacterial sulfate-reducers and sulfite-reducers constituting novel Gram-positive lineages. In total, 39 distinct 16S rRNA gene phylotypes representing ten classes were identified. The detection of several alkalitolerant, sulfide-producing, and, thus, potentially biocorrosive species underlines the need to maintain a high water quality in the DHS in order to prevent the proliferation of these species.


Asunto(s)
Bacterias Anaerobias/clasificación , Biopelículas/clasificación , Calefacción , Proteobacteria/clasificación , Acero/química , Microbiología del Agua , Bacterias Anaerobias/metabolismo , Bacterias Anaerobias/fisiología , Clonación Molecular , Recuento de Colonia Microbiana , Corrosión , Filtración , Biblioteca de Genes , Concentración de Iones de Hidrógeno , Hibridación Fluorescente in Situ , Datos de Secuencia Molecular , Filogenia , Proteobacteria/metabolismo , Proteobacteria/fisiología , ARN Ribosómico 16S/química , ARN Ribosómico 16S/clasificación , Sulfatos/metabolismo
10.
Appl Environ Microbiol ; 69(6): 3213-22, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12788718

RESUMEN

Partial nitrification of ammonium to nitrite under oxic conditions (nitritation) is a critical process for the effective use of alternative nitrogen removal technologies from wastewater. Here we investigated the conditions which promote establishment of a suitable microbial community for performing nitritation when starting from regular sewage sludge. Reactors were operated in duplicate under different conditions (pH, temperature, and dilution rate) and were fed with 50 mM ammonium either as synthetic medium or as sludge digester supernatant. In all cases, stable nitritation could be achieved within 10 to 20 days after inoculation. Quantitative in situ hybridization analysis with group-specific fluorescent rRNA-targeted oligonucleotides (FISH) in the different reactors showed that nitrite-oxidizing bacteria of the genus Nitrospira were only active directly after inoculation with sewage sludge (up to 4 days and detectable up to 10 days). As demonstrated by quantitative FISH and restriction fragment length polymorphism (RFLP) analyses of the amoA gene (encoding the active-site subunit of the ammonium monooxygenase), the community of ammonia-oxidizing bacteria changed within the first 15 to 20 days from a more diverse set of populations consisting of members of the Nitrosomonas communis and Nitrosomonas oligotropha sublineages and the Nitrosomonas europaea-Nitrosomonas eutropha subgroup in the inoculated sludge to a smaller subset in the reactors. Reactors operated at 30 degrees C and pH 7.5 contained reproducibly homogeneous communities dominated by one amoA RFLP type from the N. europaea-N. eutropha group. Duplicate reactors at pH 7.0 developed into diverse communities and showed transient population changes even within the ammonia oxidizer community. Reactors at pH 7.5 and 25 degrees C formed communities that were indistinguishable by the applied FISH probes but differing in amoA RFLP types. Communities in reactors fed with sludge digester supernatant exhibited a higher diversity and were constantly reinoculated with ammonium oxidizers from the supernatant. Therefore, such systems could be maintained at a higher dilution rate (0.75 day(-1) compared to 0.2 day(-1) for the synthetic wastewater reactors). Despite similar reactor performance with respect to chemical parameters, the underlying community structures were different, which may have an influence on stability during perturbations.


Asunto(s)
Amoníaco/metabolismo , Bacterias/clasificación , Reactores Biológicos , Ecosistema , Nitritos/metabolismo , Aguas del Alcantarillado/microbiología , Bacterias/genética , Bacterias/crecimiento & desarrollo , Bacterias/metabolismo , Medios de Cultivo , Concentración de Iones de Hidrógeno , Hibridación Fluorescente in Situ , Nitrosomonas/clasificación , Nitrosomonas/genética , Nitrosomonas/crecimiento & desarrollo , Nitrosomonas/metabolismo , Oxidación-Reducción , Oxidorreductasas/genética , Polimorfismo de Longitud del Fragmento de Restricción , Temperatura , Eliminación de Residuos Líquidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA