RESUMEN
This review discusses recent advancements in the field of valvular heart disease. Topics covered include recognition of the impact of atrial fibrillation on development and assessment of valvular disease, strategies for global prevention of rheumatic heart disease, understanding and management of secondary mitral regurgitation, the updated classification of bicuspid aortic valve disease, recognition of heightened cardiovascular risk associated with moderate aortic stenosis, and a growing armamentarium of transcatheter therapies.
Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Enfermedades de las Válvulas Cardíacas/terapia , Insuficiencia de la Válvula Mitral/terapia , Estenosis de la Válvula Aórtica/terapia , Enfermedad de la Válvula Aórtica Bicúspide/complicacionesRESUMEN
BACKGROUND AND AIMS: Incidence and types of secondary tricuspid regurgitation (TR) are not well defined in atrial fibrillation (AFib) and sinus rhythm (SR). Atrial secondary TR (A-STR) is associated with pre-existing AFib; however, close to 50% of patients with A-STR do not have AFib. The aim of this study was to assess incidence, types, and outcomes of ≥ moderate TR in AFib vs. SR. METHODS: Adults with and without new-onset AFib without structural heart disease or ≥ moderate TR at baseline were followed for the development of ≥ moderate TR. Tricuspid regurgitation types were pacemaker, left-sided valve disease, left ventricular (LV) dysfunction, pulmonary hypertension (PH), isolated ventricular, and A-STR. RESULTS: Among 1359 patients with AFib and 20 438 in SR, 109 and 378 patients developed ≥ moderate TR, respectively. The individual types of TR occurred more frequently in AFib related to the higher pacemaker implantation rates (1.12 vs. 0.19 per 100 person-years, P < .001), larger right atrial size (median 78 vs. 53â mL, P < .001), and higher pulmonary pressures (median 30 vs. 28â mmHg, P < .001). The most common TR types irrespective of rhythm were LV dysfunction-TR and A-STR. Among patients in SR, those with A-STR were older, predominantly women with more diastolic abnormalities and higher pulmonary pressures. All types of secondary TR were associated with all-cause mortality, highest in PH-TR and LV dysfunction-TR. CONCLUSIONS: New-onset AFib vs. SR conferred a higher risk of the individual TR types related to sequelae of AFib and higher pacemaker implantation rates, although the distribution of TR types was similar. Secondary TR was universally associated with increased mortality.
Asunto(s)
Fibrilación Atrial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/fisiopatología , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Femenino , Masculino , Anciano , Incidencia , Persona de Mediana Edad , Marcapaso ArtificialRESUMEN
BACKGROUND: Improvement in left atrial pressure (LAP) during transcatheter edge-to-edge repair (TEER) is associated with improved outcomes. We sought to investigate the predictors of optimal hemodynamic response to TEER. METHODS: We identified patients who underwent TEER at Mayo Clinic between May 2014 and February 2022. Patients with missing LAP data, an aborted procedure, and those undergoing a concomitant tricuspid TEER were excluded. We performed a logistic regression analysis to identify predictors of optimal hemodynamic response to TEER (defined as LAP ≤ 15 mmHg). RESULTS: A total of 473 patients were included (Mean age 78.5 ± 9.4 years, 67.2% males). Overall, 195 (41.2%) achieved an optimal hemodynamic response after TEER. Patients who did not achieve an optimal response had higher baseline LAP (20.0 [17-25] vs. 15.0 [12-18] mmHg, p < 0.001), higher prevalence of AF (68.3% vs. 55.9%, p = 0.006), functional MR (47.5% vs. 35.9%, p = 0.009), annular calcification (41% vs. 29.2%, p = 0.02), lower left ventricular EF (55% vs. 58%, p = 0.02), and more frequent postprocedural severe MR (11.9% vs. 5.1%, p = 0.02) and elevated mitral gradient >5 mmHg (30.6% vs. 14.4%, p < 0.001). In the multivariate logistic regression analysis, AF (OR = 0.58; 95% CI = 0.35-0.96; p = 0.03), baseline LAP (OR = 0.80; 95% CI = 0.75-0.84; p < 0.001) and postprocedural mitral gradient <5 mmHg (OR = 0.35; 95% CI = 0.19-0.65; p < 0.001), were independent predictors of achieving an optimal hemodynamic response. In the multivariate model, residual MR was not independently associated with optimal hemodynamic response. CONCLUSIONS: Optimal hemodynamic response is achieved in 4 in 10 patients undergoing TEER. AF, higher baseline LAP, and higher postprocedural mitral gradient were negative predictors of optimal hemodynamic response after TEER.
Asunto(s)
Calcinosis , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Resultado del Tratamiento , Hemodinámica , Ventrículos Cardíacos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversosRESUMEN
BACKGROUND: Obesity has been associated with an increased risk of vascular complication during percutaneous coronary intervention, but there are no data on the risk of vascular complication during percutaneous transfemoral transcatheter aortic valve insertion (TAVI). OBJECTIVES: We hypothesized there would be a similar increased risk associated with TAVI. METHODS: We reviewed the records of 1176 patients who received percutaneous transfemoral transcatheter aortic valve insertion from September 2015 to September 2020. All patients received 1) preoperative computed tomoraphy angiography assessment of the abdomen and pelvis to delineate iliofemoral artery anatomy, 2) ultrasound-guided percutaneous femoral arterial access, and 3) pre-closure of the delivery sheath femoral access site. Vascular complication was recorded based on definitions set forth by Valve Academic Research Consortium 3. RESULTS: The median age of patients was 81 years, and 60% were men. The median body mass index (BMI) was 29 kg/m2 (range, 11-67), and 91 (8%) patients had a value ≥40 kg/m2 (i.e., morbid obesity). Delivery sheath size was 14-French in 859 (73%) patients, 16-French in 311 (26%), and 18-French in 6 (1%). Vascular complication occurred in 53 (5%) patients, including 39 (7%) among the first half of procedures and 14 (2%) among the second half (p < 0.001). When stratified by obesity status (BMI < or ≥30 kg/m2 , p < 0.001), the complication rate was 4% in nonobese patients and 5% in obese patients. Multivariable analysis showed no overall association between risk of vascular complication and BMI categories (p = 0.583)BMI continuous values (p = 0.529), or sheath size (p = 0.217). CONCLUSIONS: Obesity is not associated with a vascular complication during percutaneous transfemoral transcatheter aortic valve insertion. The operation should not be denied in obese patients.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Obesidad/complicaciones , Obesidad/epidemiología , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugíaRESUMEN
BACKGROUND: Transcatheter tricuspid valve edge-to-edge repair (TTEER) is associated with improvement in outcomes for symptomatic patients with severe tricuspid regurgitation (TR). However, reliable predictors for clinical success are not yet fully defined. This study aims to describe right heart catheterization (RHC) findings in patients referred for TTEER and identify hemodynamic characteristics of patients who experience immediate symptomatic improvement following successful TR intervention. METHODS: Patients who underwent TTEER and had a separate RHC within the preceding 6 months were included. Hemodynamic tracings from the RHC and TTEER procedures were reviewed and recorded. Clinical success was defined as a successful device implant with at least 1-grade of TR reduction and improvement in NYHA class by 1 or more grades on 30-day echocardiogram and clinical follow-up. RESULTS: Thirteen patients underwent an RHC within 6 months of TTEER procedure (median age 76 years [IQR: 73-80]). All patients were on a stable dose of loop diuretics. Baseline right atrial pressure was severely elevated (mean 19 mmHg [IQR: 9-24 mmHg]) with prominent CV waves. Median pulmonary capillary wedge pressure (PCWP) was 20 mmHg (IQR: 14-22) and 70% of patients had a mean PCWP > 15 mmHg at rest. Median PCWP CV-wave was 34 mmHg (IQR: 23-42). Higher PCWP CV-wave height (40 mmHg [IQR 33-43] versus 18 mmHg [IQR 17-31]) was associated with lower likelihood of clinical success (OR 0.83, 95% CI: 0.35-0.97, p = 0.04). CONCLUSIONS: Inclusion of invasive hemodynamics as part of pre-TTEER evaluation may allow for improved TR phenotyping and patient selection. Patients with a large left atrial CV wave on resting RHC were less likely to experience immediate symptomatic improvement despite procedural success with TTEER.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Anciano , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Cateterismo CardíacoRESUMEN
BACKGROUND: Elevated transmitral gradient post transcatheter mitral valve edge-to-edge repair (TEER) has been associated with worse outcomes. Whether an elevated baseline transmitral diastolic mean gradient (MG) ≥5 mmHg is associated with hemodynamic outcomes after TEER is unknown. METHODS: A total of 164 consecutive patients undergoing TEER at Mayo Clinic between June 2014 and May 2018 were analyzed in this retrospective study. Baseline demographics, as well as clinical, echocardiographic, and procedural data were obtained. Data on direct left atrial pressure (LAP) before and after TEER were recorded. Logistic regression models were constructed to evaluate the association between preprocedure transmitral diastolic mean gradient (pre-MG) and (1) improvement in LAP following TEER, (2) postprocedure transmitral diastolic mean gradient (post-MG). A decrease in LAP post TEER was considered an improvement in hemodynamic response. Pre-MG was categorized as: ≥5 and <5 mmHg. RESULTS: Median age of the cohort was 81.5 years (Q1: 76.3, Q3: 87) and 34% were female. At baseline, median transmitral diastolic MG was 4 mmHg (Q1: 3, Q3: 5) and median LAP was 19 mmHg (Q1:16, Q3: 23.5). In a multivariable model, adjusted for age and sex, patients with pre-MG ≥ 5 mmHg were less likely to see an improvement in LAP post TEER (adjusted odds ratio [aOR]: 0.22, 95% confidence interval [CI]: 0.09, 0.55; p = 0.001) and more likely to have elevated post-MG (aOR; 7.08, 95% CI: 2.93, 17.13; p < 0.001). CONCLUSION: Higher pre-MG (≥5 mmHg) was associated with a lower reduction in LAP and higher residual transmitral gradient following TEER suggesting other potential contributors to increased LAP besides mitral regurgitation as a cause of elevated baseline MG.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Presión Atrial , Estudios Retrospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugíaRESUMEN
Transcatheter tricuspid valve interventions (TTVIs) comprise a variety of catheter-based interventional techniques for treatment of tricuspid regurgitation (TR) in patients at high surgical risk and those with failed previous surgeries. Several TTVI devices with different mechanisms of action are either currently used or in preclinical evaluation. Echocardiography is the first-line modality for evaluation of tricuspid valve disease that provides information on tricuspid valve morphology, mechanism of TR, and hemodynamics. Cardiac CT and MRI have several advantages for a comprehensive preprocedure evaluation. CT and MRI provide complementary information to that of echocardiography on the mechanism and cause of TR. MRI can quantify the severity of TR using indirect or direct techniques that involve two-dimensional or four-dimensional flow sequences. MRI and CT can also accurately quantify right ventricular volumes and function, which is crucial for timing of intervention. CT provides comprehensive three-dimensional information on the morphology of the valve, annulus, subvalvular apparatus, and adjacent structures. CT is the procedure of choice for evaluation of several device-specific measurements, including tricuspid annulus dimensions, annulus-to-right coronary artery distance, leaflet morphology, coaptation gaps, caval dimensions, and cavoatrial-to-hepatic vein distance. CT allows evaluation of the vascular access as well as optimal procedure fluoroscopic angles and catheter trajectory. Postprocedure CT and MRI are useful in detection of complications such as paravalvular leak, pseudoaneurysm, thrombus, pannus, infective endocarditis, and device migration. © RSNA, 2023 Quiz questions for this article are available in the supplemental material.
Asunto(s)
Aneurisma Falso , Enfermedades de las Válvulas Cardíacas , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Imagen por Resonancia Magnética , EcocardiografíaRESUMEN
BACKGROUND: Transcatheter mitral valve replacement (TMVR) has emerged as a feasible alternative to redo surgical mitral valve replacement (SMVR) in patients with degenerated mitral prostheses, with limited comparative data. METHODS: We compared mid-term outcomes in patients with degenerated mitral valve prostheses treated with TMVR or redo SMVR. The primary endpoint was survival at 5 years of follow-up. RESULTS: From 2014 to 2020, 215 patients presented with degenerated mitral valve prostheses. Of whom 86 (40%) were treated with TMVR (75[87%] valve-in-valve and 11[13%] valve-in-ring), while 129 patients (60%) underwent SMVR. The TMVR cohort was older (p < 0.0001), more symptomatic (p = 0.0003) and had more chronic lung disease (p = 0.02), worse renal function (p = 0.02) and higher right ventricular systolic pressures (p < 0.0001). Thirty-day mortality was lower with TMVR versus SMVR (2.4% vs. 10.2%, OR4.69 [95% CI 1.25-30.5], p = 0.04) with probability of mortality at 1, 2, and 5 years being 14.7% versus 17.5%, 24.5% versus 20.7%, and 49.9% versus 34.0%, respectively. Mode of prosthesis degeneration, baseline hemodynamics, and valve selection did not appreciably impact outcomes. CONCLUSIONS: TMVR for degenerated mitral prostheses is associated with better early survival compared to SMVR despite a greater burden of comorbidities. In contrast, 5 year survival rates appear more favorable with SMVR, which may reflect the lower baseline risk of this population. Clinical, hemodynamic, and echocardiographic follow-up support the mid-term durability of TMVR for degenerated mitral prostheses. Further dedicated studies, however, are required to optimize outcomes in this challenging patient cohort and to navigate the choice of approach for each individual patient.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del TratamientoRESUMEN
OBJECTIVES: To compare all-cause mortality in patients with mitral annulus calcification (MAC) and severe mitral valve dysfunction (MVD) who received standard mitral intervention versus no intervention. BACKGROUND: Patients with MAC often have high surgical risk due to advanced age, comorbidities, and technical challenges related to calcium. The impact of a mitral intervention on outcomes of patients with MAC and severe MVD is not well known. METHODS: Retrospective review of patients with MAC by transthoracic echocardiography (TTE) in 2015 at a single institution. Patients with severe mitral stenosis (MS) or regurgitation (MR) were analyzed and stratified into two groups: surgical or transcatheter intervention performed <1 year after the index TTE, and no or later intervention. The primary endpoint was all-cause mortality. RESULTS: Of 5502 patients with MAC, 357 had severe MVD (MS = 27%, MR = 73%). Of those, 108 underwent mitral intervention (surgery = 87; transcatheter = 21). They were younger (73 ± 11 vs. 76 ± 11 years, p < 0.01) and less frequently had cardiovascular diseases compared with no-intervention. Frequency in women was similar (45% vs. 50%, p = 0.44). During median follow-up of 3.2 years, the intervention group had higher estimated survival than those without intervention (80% vs. 72% at 1 year and 55% vs. 35% at 4 year, p < 0.01). Adjusted for age, eGFR, LVEF < 50%, and pulmonary hypertension, mitral intervention was an independent predictor of lower mortality (hazard ratio = 0.66, 95% confidence interval 0.43-0.99, p = 0.046). CONCLUSION: Patients with MAC and severe MVD who underwent mitral intervention <1 year from index TTE had lower mortality than those without intervention. Mitral intervention was independently associated with lower mortality.
Asunto(s)
Calcinosis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Femenino , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/terapia , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Mitral transcatheter edge-to-edge repair (MTEER) is an established therapeutic approach for mitral regurgitation (MR). Functional mitral regurgitation originating from atrial myopathy (A-FMR) has been described. OBJECTIVES: We sought to assess the clinical, echocardiographic and hemodynamic considerations in A-FMR patients undergoing MTEER. METHODS: From 2014 to 2020, patients undergoing MTEER for degenerative MR (DMR), functional MR (FMR), and mixed MR were assessed. A-FMR was defined by the presence of MR > moderate in severity; left ventricular (LV) ejection fraction (LVEF) ≥ 50%; and severe left atrial (LA) enlargement in the absence of LV dysfunction, leaflet pathology, or LV tethering. The diagnosis of A-FMR (vs. ventricular-FMR [V-FMR]) was confirmed by three independent echocardiographers. Baseline characteristics, procedural outcomes as well as clinical and echocardiographic follow-up are reported. Device success was defined as final MR grade ≤ moderate; MR reduction ≥1 grade; and final transmitral gradient <5 mmHg. RESULTS: 306 patients underwent MTEER, including DMR (62%), FMR (19%), and mixed MR (19%). FMR cases included 37 (63.8%) V-FMR and 21 (36.2%) A-FMR. Tricuspid regurgitation (≥ moderate) was higher in A-FMR (80.1%) compared to V-FMR (54%) and DMR (42%). Device success did not significantly differ between A-FMR and V-FMR (57% vs. 73%, p = 0.34) or DMR (57% vs. 64%, p = 1.0). The A-FMR cohort was less likely to achieve ≥3 grades of MR reduction compared to V-FMR (19% vs. 54%, p = 0.01) and DMR (19% vs. 49.7%, p = 0.01). Patients with V-FMR and DMR demonstrated significant reductions in mean left atrial pressure (LAP) and peak LA V-wave, though A-FMR did not (LAP -0.24 ± 4.9, p = 0.83; peak V-wave -1.76 ± 9.1, p = 0.39). In follow-up, echocardiographic and clinical outcomes were similar. CONCLUSIONS: In patients undergoing MTEER, A-FMR represents one-third of FMR cases. A-FMR demonstrates similar procedural success but blunted acute hemodynamic responses compared with DMR and V-FMR following MTEER. Dedicated studies specifically considering A-FMR are needed to discern the optimal therapeutic approaches.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
OBJECTIVES: The aim of this study was to determine the safety of eliminating the pre-discharge transthoracic echocardiogram (TTE) on 30-day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TTE is utilized before, during, and after TAVR. Post-procedural, pre-discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR. METHODS: Patients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre-discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post-TAVR. RESULTS: A total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre-discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre-discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre-discharge TTE group and none in the group without pre-discharge TTE at 30-day follow-up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre-discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71). CONCLUSIONS: Elimination of the pre-discharge TTE is safe and associated with comparable 30-day outcomes to routine pre-discharge TTE. These findings have implication for TAVR practice cost-efficiency and health care utilization.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Alta del Paciente , Estudios Prospectivos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
OBJECTIVES: We aimed to investigate the invasive hemodynamic changes with transcatheter mitral valve replacement (TMVR) in patients with severe mitral stenosis due to severe mitral annular calcification. BACKGROUND: The hemodynamic response to TMVR in patients with mitral stenosis related to degenerative mitral annular calcification has not been fully elucidated. METHODS: We conducted retrospective review of patients who underwent successful transseptal TMVR with balloon-expandable valves for symptomatic severe mitral stenosis due to mitral annular calcification at our institution between January 2014 and February 2020. Invasive hemodynamic measurements were obtained both before valve implantation (predeployment) and after (postdeployment). RESULTS: Eighteen patients (age 72 ± 10 years, 44% female) were included for the analysis. There was a significant reduction in mean left atrial pressure (23.7 ± 5.6 mmHg versus 20.6 ± 4.8 mmHg; p = .01), left atrial v-wave (mean 39.3 ± 10.2 mmHg versus 32.9 ± 9.9 mmHg; p = .01), and an increase in systemic mean blood pressure (72.6 mmHg ±11.2 versus 79.5 ± 9.9 mmHg; p = .02) postdeployment compared to predeployment. Patients who had symptom improvement at 30-day follow-up tended to have greater reduction in mean left atrial pressure (4.4 ± 4.4 mmHg versus 0.5 ± 5.2 mmHg; p = .16) and v-wave (8.6 ± 9.0 mmHg versus 0.7 ± 8.4 mmHg; p = .10) compared to those who did not experience improvement of symptoms. CONCLUSIONS: Transseptal TMVR for severe mitral stenosis due to mitral annular calcification is associated with reductions in mean left atrial pressure and left atrial v-wave, and an increase in systemic arterial pressure.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
OBJECTIVES: To determine the incidence, characteristics, and outcomes of patients with hemolysis after transcatheter mitral valve replacement (TMVR). BACKGROUND: Hemolysis is an increasingly recognized complication of TMVR. Clinical outcomes and optimal management for patients with hemolysis after TMVR are unclear. METHODS: Patients that underwent mitral valve-in-valve (MViV), valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) at a single center were retrospectively assessed. RESULTS: A total of 101 patients had TMVR, including 69 with MViV, 14 with MViR, and 18 with ViMAC. ViMAC patients had an increased frequency of mild or greater paravalvular leak (PVL) (ViMAC, 72.2%; MViR, 14.3%; MViV, 13.0%; p < .001). Hemolysis occurred in eight patients and was more common after ViMAC (ViMAC, 33.3%; MViR, 7.1%; MViV, 1.5%; p < .001). This required transfusion in five (ViMAC, 4; MViV, 1) and was associated with acute kidney injury in five with ViMAC. Among the ViMAC patients, four had transcatheter re-intervention to treat hemolysis with resolution of anemia in three and mild residual anemia in one with persistent mild PVL. The two ViMAC patients without re-intervention had persistent anemia and died within 6 months. Both MViV and MViR patients with hemolysis did not have PVL but had turbulent flow from left ventricular outflow tract narrowing and their hemolysis was self-limited. CONCLUSIONS: Hemolysis occurs with greater frequency and increased clinical severity after ViMAC as compared to MViV or MViR and is likely related to increased incidence of PVL. These findings demonstrate the need to investigate novel strategies that can reduce the burden of hemolysis with ViMAC.
Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemólisis , Humanos , Incidencia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
OBJECTIVE/BACKGROUND: Small balloon expandable valves have higher echocardiographic transvalvular gradients and rates of prosthesis-patient mismatch (PPM) compared to larger valves. However, the impact of these echocardiographic findings on clinical outcomes is unknown. We sought to determine the clinical outcomes of 20 mm SAPIEN 3 (S3 BEV) compared to larger S3 BEV in relation to echocardiographic hemodynamics. METHODS: Using the STS/ACC transcatheter valve registry, we performed a propensity-matched comparison of patients undergoing treatment of native aortic valve stenosis using transfemoral, balloon-expandable implantation of 20 mm and ≥ 23 mm S3 BEVs. Baseline and procedure characteristics, echocardiographic variables and survival were analyzed. Multivariable logistic regression was used to identify predictors of 1-year mortality. RESULTS: After propensity matching of the 20 mm and ≥ 23 mm SAPIEN 3 valves, 3,931 pairs with comparable baseline characteristics were identified. Small valves were associated with significantly higher echocardiographic gradients at discharge (15.7 ± 7.1 mmHg vs. 11.7 ± 5.5 mmHg, p < 0.0001) and severe PPM rates (21.5% vs. 9.7%, p < 0.0001). There was no significant difference in 1-year all-cause mortality (20 mm: 13.0% vs. ≥23 mm: 12.7%, p = 0.72) or other major adverse event rates and outcomes between the two cohorts. Based on a multivariable analysis, elevated discharge mean gradient (>20 mmHg), severe PPM and the use of 20 mm versus ≥23 mm were not independent predictors of 1-year mortality. CONCLUSION: SAPIEN 3 20 mm valves were associated with higher echocardiographic gradients, and severe PPM rates compared to larger valves but these factors were not associated with significant differences in 1-year all-cause mortality or rehospitalization.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
OBJECTIVES: The purpose of this study was to explore the feasibility and safety of robotic PCI performed using an off-siteremote-control system in an animal model. BACKGROUND: Access to primary percutaneous coronary intervention (PCI) remains a challenge in acute myocardial infarction management. The combination of telemedicine and robotic PCI allow the potential delivery of primary PCI to remote locations without the delay of transfer. METHODS: This single-center prospective pilot preclinical feasibility study compared robotic PCI with remote PCI on swine across three stages (adjacent room, different floor of the same building, two different buildings). Latency up to 1,000 ms was introduced into the operating environment to simulate decreased network quality (blinded to operator). The primary outcome measures were technical success and acute safety. The secondary outcome measures included lesion wiring time, procedural time and qualitative scoring of the PCI experience by the operator. RESULTS: Across 52 experiments in 15 animals, technical success was 100%. No procedural complications occurred during the study. No significant difference in lesion treatment time was detected between stages (p = .11) and between time per target vessel when latency up to 1,000 ms was introduced (p = .58). Injected delay >250 ms had the greatest impact on procedure perceived lag. Longer procedure time was associated with lower procedure impact score, regardless of injected latency. CONCLUSIONS: Remote robotic PCI was feasible and safe in an animal model. Procedural duration was acceptable and unaffected by network latency. Future studies are needed to determine the safety and feasibility of remote PCI in humans.
Asunto(s)
Intervención Coronaria Percutánea , Procedimientos Quirúrgicos Robotizados , Animales , Estudios de Factibilidad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Porcinos , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Surgical intervention in patients with native mitral disease due to severe mitral annular calcification (MAC) carries significant risk. Transcatheter mitral valve replacement (TMVR) using balloon-expandable aortic transcatheter heart valve (THV) in MAC had emerged as alternative treatment. OBJECTIVES: We aim to study the temporal change in clinical outcomes of the procedure at a single center. METHODS: We retrospectively studied 23 patients who underwent TMVR in MAC at Mayo Clinic from January, 14, 2014 to March, 15, 2019. Cases were divided into early (n = 11) and late (n = 12) experience. The primary end point was 30-day all-cause mortality. The secondary end points were immediate technical success, 30-day procedural success, and 1-year all-cause mortality. RESULTS: Mean age of patients was 75.2 ± 8.9 years and 17 (74.0%) were female. Median STS score for 30-day mortality was 8 (Interquartile range 4.3-13.4) for the entire population. Immediate technical success was achieved in 21 out of 23 patients (two failures in the early experience were related to tamponade and procedural death). Thirty-day procedural success was higher in the late experience (10 out of 12 patients) compared to early experience (5 out of 11 patients, p = .06). Four deaths in the first 30-days were observed in the early experience while all patients survived to hospital discharge in the late experience (p = .01). CONCLUSIONS: Procedural success and 30-day survival of transcatheter mitral valve replacement in severe mitral annular calcification procedure using balloon-expandable aortic prosthesis had improved over the years. This is likely attributed to significant advancement in procedural planning, valve design, and techniques.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Change in left atrial pressure (LAP) has been shown to be associated with symptom improvement post-MitraClip; however, the association between acute procedural changes in transmitral diastolic mean gradient (MG) compared to LAP and symptom improvement is not well established. METHODS: 164 consecutive patients undergoing MitraClip at Mayo Clinic between June 2014 and May 2018 were included. Preclip and postclip MG and LAP were recorded. Baseline demographics, clinical, and echocardiographic outcomes, including 30-day New York Heart Association (NYHA) functional status were obtained from patient charts. RESULTS: Median age was 81.5 years (IQR: 76.3, 87), 34% were female and 94.5% had NYHA class III and IV functional status at baseline. At baseline, median MG was 4 mmHg (IQR: 3, 5) and LAP was 19 mmHg (IQR: 16, 23.5). Following MitraClip deployment, the median MG was 4 mmHg (IQR: 3, 6) and the median LAP was 17 mmHg (IQR: 14, 21), 69.5% of patients had less than moderate MR. There was no statistically significant association between change in MG and NYHA functional class at 30 days (OR = 0.95, 95% CI: 0.76-1.20). However, a reduction in LAP following MitraClip deployment was significantly associated with improvement in NYHA functional status at 30 days following adjustments for age and sex (aOR 3.36, 95% CI: 1.34-8.65). There was no significant correlation between change in mean LAP and change in MG (p = .98). CONCLUSION: Unlike change in left atrial pressure, change in MG post-MitraClip was not associated with patient reported outcomes at 30 days and did not correlate with change in left atrial pressure. Long-term follow up is needed to evaluate the impact of LA pressure on symptoms.
Asunto(s)
Presión Atrial , Insuficiencia de la Válvula Mitral , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Femenino , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Medición de Resultados Informados por el Paciente , Resultado del TratamientoRESUMEN
BACKGROUND: The predictors and clinical significance of increased Doppler-derived mean diastolic gradient (MG) following transcatheter edge-to-edge mitral valve repair (MVTEER) remain controversial. OBJECTIVE: We sought to examine baseline correlates of Doppler-derived increased MG post-MVTEER and its impact on intermediate-term outcomes. METHODS: Patients undergoing MVTEER were analyzed retrospectively. Post-MVTEER increased MG was defined as >5 mmHg or aborted clip implantation due to increased MG intraprocedurally. Baseline MG and 3D-guided mitral valve area (MVA) by planimetry were retrospectively available in 233 and 109 patients. RESULTS: 243 patients were included; 62 (26%) had MG > 5 mmHg post-MVTEER or aborted clip insertion, including 7 (11%) that had aborted clip implantation. Mortality occurred in 63 (26%) during a median follow up of 516 days (IQR 211, 1021). Increased post-MVTEER MG occurred more frequently in females (44% vs. 16%, p < 0.001), those with baseline MVA <4.0 cm2 (71% vs. 16%), baseline MG ≥4 mmHg (61% vs. 20%), or multiple clips implanted (33% vs. 21%, p = 0.04). Increased post-MVTEER MG was associated with increased subsequent mortality compared to those with normal gradient (HR 1.91 95% CI 1.15-3.18 p = 0.016) as was aborted clip insertion compared to all others (HR 5.23 95% CI 2.06-13.28 p < 0.001). CONCLUSIONS: Smaller baseline MVA and increased baseline MG are associated with increased MG post-MVTEER and patients with a Doppler-derived post-MVTEER MG >5 mmHg suffered excess subsequent mortality. In high risk patients considered for MVTEER, identification of those at risk of iatrogenic mitral stenosis with MVTEER is important as they may be optimally treated with alternate surgical or transcatheter therapies.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Femenino , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
OBJECTIVES: We sought to determine hemodynamic effects of aortic paravalvular leak (PVL) and predictors of clinical outcomes after aortic PVL closure. BACKGROUND: The significance of hemodynamic alterations in PVL and relation to severity, procedural success of percutaneous closure and clinical outcomes have not been defined. METHODS: Patients undergoing percutaneous PVL closure between July 21, 2004 and September 10, 2018 were included. PVL severity was assessed by echocardiography and aortic angiography. Hemodynamics were assessed by intra-arterial pressure tracings before and after PVL closure. The primary outcome was a composite of mortality, redo aortic valve replacement (AVR) and redo PVL closure. RESULTS: One hundred and seventeen patients (mean age 70.3 ± 14.9 years, 79% surgical and 21% transcatheter prostheses) underwent PVL closure with 94% technical success. PVL was moderate or greater in 106 (91%) at baseline and 11 (11%) post-procedure. Diastolic BP for those with moderate or greater PVL was lower than for those with less PVL (50.3 ± 11.7 vs. 56.5 ± 12.4 mmHg, p < .001). Pulse pressure was similar between these groups (69.9 ± 20.3 vs. 67.4 ± 21.2 mmHg, p = .39). 35 patients (34%) had 40 events during a mean follow-up of 1.6 ± 1.9 years (23 deaths, 12 redo AVR, and five redo PVL closures). In a multivariate model, final diastolic BP <47 mmHg (HR 3.27 [1.45-7.36], p = .007) was a significant predictor of the composite endpoint. CONCLUSIONS: Diastolic BP was significantly associated with aortic PVL severity and clinical outcomes after PVL closure. In contrast, pulse pressure did not correlate with PVL severity or outcomes. These findings have implications for clinical management of patients with aortic PVL.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Presión Sanguínea , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
OBJECTIVES: The aim of this study was to assess the 30 day incidence of paravalvular leak (PVL) and need for aortic valve reintervention of a fourth generation balloon expandable transcatheter valve with enhanced skirt (4G-BEV) (SAPIEN 3 Ultra) compared with a third generation balloon expandable transcatheter valve (3G-BEV) (SAPIEN 3). BACKGROUND: The incidence of PVL has steadily declined with iterative improvements in transcatheter aortic valve replacement (TAVR) technology and implantation strategies. METHODS: Patients who underwent TAVR at Mayo Clinic from 7/2018 to 7/2019 were included in a prospective institutional registry. 4G-BEV has been utilized since 2/2019, and, after this date, 3G-BEV and 4G-BEV were simultaneously used. 4G-BEV had three sizes (20, 23, and 26 mm) while 3G-BEV included four sizes (20, 23, 26, and 29 mm). Both cohorts were evaluated at 30 days post-TAVR with a transthoracic echocardiogram to assess for PVL. RESULTS: A total of 260 consecutive patients were included. Of these, 101 patients received a 4G-BEV and 159 patients received a 3G-BEV. There were more females (p = .0005) and a lower aortic valve calcium score (p = .02) in the 4G-BEV cohort at baseline. Age, STS risk score, NYHA Class, and aortic valve mean gradient did not differ between groups. 4G-BEV was associated with a lower incidence of mild PVL (10.8 vs. 36.5%; p < .0001) and moderate PVL (0 vs. 5.8%) compared to the 3G-BEV at 30 days. There was no association between PVL and valve size in either cohort. CONCLUSIONS: Utilization of 4G-BEV is associated with reduced PVL at 30 days post-TAVR compared with 3G-BEV.