Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 45(1): 124-131, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34806769

RESUMEN

BACKGROUND: When compared to patients with normal renal function, patients with chronic kidney disease develop higher in-hospital complications post implantable cardioverter-defibrillator (ICD) therapy. However, real world data on in-hospital complications post ICD therapy in patients with end stage renal disease (ESRD) is limited. In this study, we aim to explore the procedure-related complications of ICD therapy in patients with ESRD. METHODS: Using the nationwide inpatient sample (NIS) database, we conducted a retrospective analysis on ESRD patients who underwent inpatient ICD placement from 2010 to 2016. Using 1:2 propensity score matching, we compared ESRD patients to those with normal renal function. Outcomes of interest were postoperative hemorrhage and hematoma formation, blood transfusion, pericardial complications, mechanical complications requiring lead revision, vascular injury, in-hospital mortality, and length of stay. RESULTS: Our sample included 40,075 cases with subsequent propensity score matching between ESRD and normal renal function. Comparatively, patients with ESRD had higher odds of postoperative hemorrhage (Odds ratio [OR] = 1.67, 95% confidence interval [CI] 1.4-1.99, p = < .0001), blood transfusion (OR, 3.88; CI 3.29-4.56; p = < .0001), mechanical complications requiring lead revision (OR, 1.24; CI 1.01-1.51; p = .035), vascular injury (OR, 2.02; CI 1.27-3.24; p = .0027), in-hospital mortality (OR, 4.56; CI 3.08-6.76; p = < .0001), and longer hospitalization (11 vs. 7 days, p = < .0001), but without significant difference in pericardial complications (OR, 1.9; CI 0.92-1.54; p = < .18). CONCLUSION: In this large contemporary cohort, patients with ESRD undergoing inpatient ICD therapy are at higher risk of developing postprocedural complications including hemorrhage and hematoma, blood transfusion, mechanical complications requiring lead revision, and in hospital mortality, without increased risk of pericardial complications.


Asunto(s)
Desfibriladores Implantables , Fallo Renal Crónico/complicaciones , Complicaciones Posoperatorias/epidemiología , Anciano , Transfusión de Componentes Sanguíneos/estadística & datos numéricos , Bases de Datos Factuales , Femenino , Hematoma/epidemiología , Hemorragia/epidemiología , Mortalidad Hospitalaria , Humanos , Fallo Renal Crónico/mortalidad , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Estados Unidos/epidemiología
2.
Cardiol Cardiovasc Med ; 7(2): 69-78, 2023 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-37168252

RESUMEN

Background: Patients with PR intervals >240ms have atrio-ventricular (AV) dyssynchrony, which can increase risk of atrial fibrillation and all-cause mortality. When requiring pacing, long AV delays (AVDs) have been programmed to avoid ventricular dyssychrony. His bundle pacing (HBP) may provide improved AV synchrony in patients with prolonged PR. Methods: 10 patients with sinus node dysfunction and prolonged PR who received HBP were studied. Real-time echocardiographic was performed with 3 pacemaker modes (RV septal, non-selective HBP, and selective HBP) using the following pacemaker settings: control (no ventricular pacing), pacing with AVD of 180ms, 150ms, 120ms, 100ms, and 70ms. Echocardiographic Doppler measurements: EA/RR, >40% = AV synchrony; E/e', <8 = normal left atrial pressure; pulmonic-to-aortic pre-ejection time difference, <40ms = interventricular synchrony; septal-to-lateral wall activation time difference, <56ms = intraventricular synchrony; and LVOT VTI. Unpaired T test was used to evaluate for significance. Exclusion criteria: persistent atrial fibrillation, second-degree AV block. Results: Compared to control programming, HBP showed a 31.5% increase in EA/RR time, a decrease in E/e' of 26.9%, and an increase in the LVOT VTI of 21.3%. Compared to RV septal pacing, there was a similar increase in LVOT VTI. These findings met statistical significance and were considered optimal based on Doppler echocardiography findings primarily at AVDs of 150ms and 120ms. Comparisons between selective and non-selective pacing were not significantly different. Conclusion: Compared to controls and RV septal pacing, physiologic His bundle pacing was shown to increase markers of AV synchrony and LV stroke volume while maintaining ventricular synchrony.

3.
J Cardiovasc Pharmacol ; 55(5): 450-5, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20509178

RESUMEN

Current guidelines for use of implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden death in patients with coronary disease and nonischemic dilated cardiomyopathy are based primarily on ejection fraction (EF) <30%-35%. The origin of this is based on EF as the common variable in several randomized clinical trials evaluating the ability of ICDs to reduce mortality. However, although low EF identifies one patient population at relatively increased risk for sudden death, there are a number of limitations to use of EF as the primary indication for ICD. Patients with low EF are not uniform with regard to other prognostic markers, and not all are at high risk for sudden death. Conversely, although patients with EF >35% as a group are at lower risk for sudden death, these patients are not uniform with regard to other prognostic variables. A variety of tests, including measures of reduced repolarization reserve and measures of altered sympathetic/parasympathetic balance, have identified patients with EF >35% at relatively high risk for sudden death. One explanation for this "disconnect" is that there is no evidence of any direct mechanistic link between low EF and mechanisms responsible for ventricular tachyarrhythmias.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Guías de Práctica Clínica como Asunto , Función Ventricular Izquierda/fisiología , Pruebas de Función Cardíaca , Humanos , Medición de Riesgo
4.
J Cardiovasc Electrophysiol ; 18(2): 192-5, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17239139

RESUMEN

BACKGROUND: Dual-coil implantable defibrillator (ICD) leads with true bipolar pacing and sensing (quadripolar leads) have been introduced to provide improved sensing characteristics without sacrificing defibrillation efficacy. Electrode configuration has been shown to have little effect on the amplitude or slew rate of the intracardiac electrogram, but does have an effect on the duration of the sensed electrogram. Closer spacing of the electrodes and smaller surface area of the anode may, therefore, result in a different latency of sensing relative to the onset of the QRS complex. METHODS: We tested the difference in ventricular sensing latency between integrated bipolar and true bipolar electrode configurations in 40 patients undergoing ICD implantation for standard indications (Medtronic Sprint Quattro lead in 26 and St. Jude Riata in 16). In addition, we compared R wave amplitude, pacing threshold, impedance, and slew rate. RESULTS: Sensing latency was significantly longer in the true bipolar configuration (Medtronic Sprint Quattro 45.2 +/- 14.7 msec in the true bipolar configuration, vs 37.4 +/- 18.2 msec in the integrated bipolar configuration, and St. Jude Riata, 43.5 +/- 9.8 msec true bipolar, vs 33.8 +/- 10.1 msec integrated bipolar, P < 0.01). There was no difference in R wave amplitude or slew rate. Pacing threshold and impedance were also greater in the true bipolar configuration than in the integrated bipolar configuration. CONCLUSION: The true bipolar configuration has a longer sensing latency than the integrated bipolar configuration. In some patients, this may require a longer programmed AV delay to avoid ventricular pseudofusion.


Asunto(s)
Desfibriladores Implantables , Arritmias Cardíacas/terapia , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis
5.
Chest ; 132(2): 433-9, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17573498

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to improve cardiac function and reduce Cheyne-Stokes respiration but has not been evaluated in patients with obstructive sleep apnea (OSA). In this pilot study, we investigated the impact of both CRT and CRT plus increased rate pacing in heart failure (ie, congestive heart failure [CHF]) patients with OSA. We hypothesized that through increased cardiac output CRT/pacing would reduce obstructive events and daytime symptoms of sleepiness. METHODS: Full polysomnograms were performed on CHF patients who were scheduled for CRT, and those patients with an apnea-hypopnea index (AHI) of > 5 events per hour were approached about study enrollment. Patients had a pre-CRT implant baseline echocardiogram and an echocardiogram a mean (+/- SEM) duration of 6.6 +/- 1.4 months post-CRT implant; polysomnography; and responded to the Minnesota Living with Heart Failure questionnaire, the Epworth sleepiness scale, and the Functional Outcomes of Sleep Questionnaire. An additional third polysomnography was performed combining CRT with a pacing rate of 15 beats/min above the baseline sleeping heart rate within 1 week of the second polysomnography. Assessments for the change in cardiac output during the polysomnography were performed using circulation time to pulse oximeter as a surrogate. RESULTS: Twenty-four patients were screened, and 13 patients (mean age, 68.6 years; body mass index, 28.7 kg/m(2)) had evidence of OSA. The mean AHI decreased from 40.9 +/- 6.4 to 29.5 +/- 5.9 events per hour with CRT (p = 0.04). The mean baseline ejection fraction was 22 +/- 1.7% and increased post-CRT to 33.6 +/- 2.0% (p < 0.05). The reduction in AHI with CRT closely correlated with a decrease in circulation time (r = 0.89; p < 0.001) with CRT. Increased rate pacing made no additional impact on the AHI or circulation time. CRT had a limited impact on sleep architecture or daytime symptom scores. CONCLUSIONS: CRT improved cardiac function and reduced the AHI. Reduced circulatory delay likely stabilized ventilatory control systems and may represent a new therapeutic target in OSA.


Asunto(s)
Estimulación Cardíaca Artificial , Insuficiencia Cardíaca/terapia , Apnea Obstructiva del Sueño/fisiopatología , Volumen Sistólico/fisiología , Anciano , Ecocardiografía , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Microcirculación/fisiología , Oximetría , Proyectos Piloto , Polisomnografía , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Apnea Obstructiva del Sueño/sangre , Apnea Obstructiva del Sueño/complicaciones , Encuestas y Cuestionarios
6.
Expert Rev Cardiovasc Ther ; 15(6): 429-440, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28489502

RESUMEN

INTRODUCTION: There have been many evolutionary milestones in cardiac implantable electronic device (CIED) therapy over the past few decades. These advancements have created new  challenges. Right ventricular pacing was the original (late 1950s) breakthrough, however the risk of pacing induced dyssynchrony has become evident. Biventricular pacing provided a viable way to mitigate dyssynchrony, but only benefits certain patients (primarily left bundle branch block and QRS duration ≥150 ms with depressed left ventricular (LV) function). Areas covered: Recent advances have made His Bundle pacing an option that may provide physiological pacing for a wider patient population. Traditional CIED systems utilize transvenous endocardial leads. Unfortunately, leads have been CIEDs' weakest link. Lead-related vascular occlusion, infection and malfunction have spurred the need for percutaneous lead extraction, and development of subcutaneous ICDs and leadless pacing. These options are important for individuals with limited vascular access and those at risk for blood borne infection. Subcutaneous ICDs have been proposed as optimal for younger patients. This recommendation is controversial. Expert commentary: We review recent advances including His bundle pacing, percutaneous lead extraction, leadless pacing and subcutaneous ICDs as well as their potential use in combination. Additional technological evolution promises to make the future of CIEDs exciting.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Desfibriladores Implantables , Cardioversión Eléctrica , Bloqueo de Rama/fisiopatología , Terapia de Resincronización Cardíaca , Ventrículos Cardíacos/fisiopatología , Humanos , Función Ventricular Izquierda
7.
Circulation ; 106(21): 2694-9, 2002 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-12438295

RESUMEN

BACKGROUND: Beta-blockers are known to reduce total mortality and sudden death in survivors of recent myocardial infarction. The effects of these agents in patients at high risk for sudden death with remote infarction are not clear. METHODS AND RESULTS: We analyzed the effect of beta-blockers on outcomes in 2096 patients with coronary artery disease, ejection fraction < or =40%, and spontaneous nonsustained ventricular tachycardia enrolled in the Multicenter UnSustained Tachycardia Trial (MUSTT). Forty-five percent of 702 patients with inducible sustained ventricular tachyarrhythmia and 35% of 1394 patients without inducible tachycardia were discharged from hospital receiving beta-blockers. Patients treated with beta-blockers were younger and had higher ejection fractions, higher rates of recent angina, and more recent infarction. beta-Blockers were associated with decreased total mortality for the entire study population (5-year mortality 50% with beta-blockers versus 66% without beta-blockers; adjusted P=0.0001). The mortality benefit associated with beta-blockers was present in patients with and without inducible tachycardia, except those treated with implantable defibrillators. There was no significant effect of beta-blocker therapy on the rate of arrhythmic death or cardiac arrest (adjusted P=0.2344). CONCLUSIONS: beta-Blocking agents have beneficial effects on survival of patients having characteristics of those enrolled in the MUSTT trial. These effects do not appear to be due to a specific antiarrhythmic effect of beta-blockers. The beneficial effects of beta-blockers were demonstrable in all patients except those treated with implantable defibrillators.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Taquicardia Ventricular/tratamiento farmacológico , Anciano , Canadá , Enfermedad de la Arteria Coronaria/complicaciones , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Electrocardiografía/efectos de los fármacos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Volumen Sistólico , Tasa de Supervivencia , Taquicardia Ventricular/complicaciones , Resultado del Tratamiento , Estados Unidos
8.
Drugs ; 65(6): 787-97, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15819591

RESUMEN

beta-Adrenoceptor antagonists (beta-blockers) provide multiple benefits to patients with coronary artery disease. The 2001 American Heart Association and American College of Cardiology (AHA/ACC) guidelines for secondary prevention of myocardial infarction (MI) recommend initiating beta-adrenoceptor blockade in all post-MI patients and continuing therapy indefinitely. Atenolol and metoprolol have been shown to decrease vascular mortality in the acute-MI period. In the post-MI period timolol provided a 39% reduction in mortality in the Norwegian Multicenter Study group and propranolol was associated with a 26% reduction in mortality in BHAT (Beta-blocker Heart Attack Trial). beta-Adrenoceptor antagonist therapy results in reduction of myocardial oxygen demand and is therefore also effective for the treatment of angina pectoris. In CAST (Cardiac Arrhythmia Suppression Trial) beta-adrenoceptor antagonist therapy was associated with a significant reduction in arrhythmic death or cardiac arrest. In the post-MI amiodarone trials EMIAT (European Myocardial Infarct Amiodarone Trial) and CAMIAT (Canadian Amiodarone Myocardial Infarction Trial) there was a mortality benefit and decreased arrhythmic death in patients who received both amiodarone and beta-adrenoceptor antagonist therapy, compared with patients receiving amiodarone therapy alone. In the post-MI defibrillator (implantable cardioverter defibrillator [ICD]) trials, AVID (Antiarrhythmic Versus Implantable Defibrillator) and MUSTT (Multicenter Unsustained Tachycardia Trial), beta-adrenoceptor antagonist therapy was independently associated with improved overall survival. The exception was the ICD patients in MUSTT, and the benefit was attenuated in the amiodarone and ICD patients in AVID.AHA/ACC guidelines recommend the use of beta-adrenoceptor antagonists in all patients with symptomatic left ventricular dysfunction, based on several large, controlled heart failure trials. Extended-release metoprolol succinate reduced all-cause mortality by 34% in MERIT-HF (Metoprolol Controlled-Release/Extended-Release Randomized Intervention Trial in Heart Failure). Bisoprolol was associated with a 34% mortality benefit in CIBIS-II (Cardiac Insufficiency Bisoprolol Study II) and carvedilol was associated with a 35% mortality reduction in the COPERNICUS (Carvedilol Prospective Randomized Cumulative Survival) trial. beta-Adrenoceptor antagonists reduce perioperative mortality in patients undergoing cardiac as well as non-cardiac surgery; however, they remain underutilised. Contraindications to beta-adrenoceptor antagonist therapy include severe bradycardia, high-grade atrioventricular block, marked sinus node dysfunction and acute exacerbations of heart failure. Many of the perceived adverse effects of beta-adrenoceptor antagonists have not been substantiated by large clinical trials.beta-Adrenoceptor antagonists differ with regard to receptor selectivity, receptor affinity, lipophilicity and intrinsic sympathomimetic activity. Beneficial properties of beta-adrenoceptor antagonists may not always be extrapolated as a class effect, and patient selection and drug preparations should follow trial guidelines. The beneficial effects of beta-adrenoceptor antagonists are clearly proven in cardiac patients and those at risk for cardiac disease. They are indicated for heart failure and proven beneficial in patients undergoing cardiac and non-cardiac surgery. These benefits appear to be consistent across most patient subgroups. beta-Adrenoceptor antagonists are generally well tolerated, yet significant morbidity and mortality result from their continued underutilisation.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/metabolismo , Receptores Adrenérgicos beta/metabolismo , Antagonistas Adrenérgicos beta/farmacología , Humanos
10.
Congest Heart Fail ; 9(2): 91-9, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12671340

RESUMEN

Arrhythmias continue to contribute significantly to morbidity and mortality in heart failure. Implantable defibrillators have assumed an increasingly important role in preventing sudden death and are recommended for patients who have been resuscitated from cardiac arrest, have unexplained syncope, or exhibit inducible ventricular tachycardia in the setting of prior myocardial infarction. The extension of survival conferred by implantable defibrillators is likely to be limited in patients with advanced heart failure. Ongoing trials will help define the use of these devices in heart failure populations, in whom atrial fibrillation is common and rate control and anticoagulation are of major importance. Among pharmaceutical options, amiodarone and dofetilide are the major agents for maintenance of sinus rhythm. The complexity of coexistent heart failure and arrhythmia management warrants close collaboration between heart failure and arrhythmia specialists.


Asunto(s)
Arritmias Cardíacas/terapia , Insuficiencia Cardíaca/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Manejo de la Enfermedad , Insuficiencia Cardíaca/epidemiología , Humanos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Estados Unidos/epidemiología , Disfunción Ventricular Izquierda/epidemiología , Disfunción Ventricular Izquierda/terapia
11.
J Interv Card Electrophysiol ; 9(2): 203-6, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14574032

RESUMEN

Over the past decade, four randomized, controlled trials have evaluated therapies for prevention of sudden cardiac death in patients with coronary disease. Three of the four trials have shown significant reductions in mortality with implanted defibrillators. Two studies failed to demonstrate any benefit from pharmacologic antiarrhythmic therapy. The results of these studies in similar patient populations have erased any doubt regarding the ability of implanted defibrillators to reduce the risk of sudden death in patients with coronary disease. Our major challenge at this time is understanding how best to utilize this therapy in order to bring the benefit to the maximum number of patients while minimizing expense.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Prevención Primaria , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables , Paro Cardíaco/mortalidad , Paro Cardíaco/fisiopatología , Paro Cardíaco/terapia , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Volumen Sistólico/fisiología , Estados Unidos/epidemiología
12.
Cardiol Rev ; 10(1): 8-14, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-11790264

RESUMEN

Arrhythmias often complicate the management of heart failure and contribute to mortality and morbidity. Implantable cardioverter defibrillators are the best protection from death caused by ventricular arrhythmias, but their benefit will probably be less in heart failure populations than has been observed in trials that have not focused on heart failure populations. Implantable cardioverter defibrillators are first-line therapy for high-risk patients who have been resuscitated from sustained ventricular tachycardia or ventricular fibrillation, who have inducible ventricular tachycardia in the setting of previous myocardial infarction, or who have unexplained syncope. Amiodarone is the major pharmacologic option for treatment of symptomatic arrhythmias. In selecting therapy, the severity of heart failure and cause of heart failure are important considerations. Atrial fibrillation occurs with increasing frequency as the severity of heart failure increases. Anticoagulation and rate control are important. Attempted maintenance of sinus rhythm with amiodarone or dofetilide is a reasonable consideration for selected patients, although the benefit of treatment strategies that seek to maintain sinus rhythm has not been demonstrated. Ongoing trials will provide further guidance for arrhythmia management.


Asunto(s)
Fibrilación Atrial/terapia , Insuficiencia Cardíaca/terapia , Fibrilación Ventricular/terapia , Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/etiología , Fibrilación Atrial/mortalidad , Muerte Súbita Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Humanos , Fenetilaminas/uso terapéutico , Sulfonamidas/uso terapéutico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/mortalidad
14.
J Cardiopulm Rehabil Prev ; 30(6): 401-8, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20562712

RESUMEN

PURPOSE: In patients with heart failure, reduced cardiac ejection fraction has been associated with impaired cognition. Improving cardiac function may have beneficial effects on cognition; however, no controlled intervention studies have examined this possibility. Cardiac resynchronization therapy (CRT) is one intervention that has been shown to increase cardiac function. The goals of the current study were to (1) evaluate neuropsychological performance before and 3 months after crt and (2) examine follow-up neuropsychological performance of patients classified on the basis of extent of improved left ventricular ejection fraction (LVEF). METHODS: Twenty-seven patients with moderate to severe heart failure completed a neuropsychological assessment, 6-minute walk test, and transthoracic echocardiography before and 3 months after CRT. Patients were classified on the basis of improvement in LVEF. Results of a multivariate analysis of variance revealed a significant effect of improvement in LVEF on change in cognition (Wilks Λ, P = .031). RESULTS: Patients with improved LVEF demonstrated significant increases on measures of executive functioning (F = 8.57, P = .007) and visuospatial function (F = 7.52, P = .011) and less decline on global cognition (F = 5.73, P = .024) than those without LVEF improvement. CONCLUSIONS: Findings provide preliminary evidence that improved LVEF in response to CRT is associated with enhanced cognitive outcomes within 3 months of CRT. Patients with improved LVEF showed better outcomes on measures of executive functioning, global cognition, and visuospatial functioning. Future, controlled, large-scale trials will be necessary to determine whether there is an underlying causal relationship linking increase in LVEF and cognition.


Asunto(s)
Estimulación Cardíaca Artificial , Trastornos del Conocimiento/prevención & control , Cognición , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda , Análisis de Varianza , Trastornos del Conocimiento/etiología , Prueba de Esfuerzo , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Estudios Prospectivos , Psicometría , Factores de Riesgo , Estadística como Asunto , Volumen Sistólico , Encuestas y Cuestionarios , Factores de Tiempo
17.
Clin Interv Aging ; 3(3): 553-60, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18982925

RESUMEN

The aim of the study was to examine changes in health-related quality of life among older adults undergoing cardiac resynchronization therapy (CRT), a pacemaker based intervention for heart failure. Twenty-one patients (mean age = 68; SD = 8) completed measures of cardiovascular health and quality of life prior to and 3-months post-CRT. Following the intervention, patients reported improvements in their perception of their physical functioning (t = 2.8, p < 0.01) and feelings of vitality (t = 2.9, p < 0.01) on the MOS SF-36 Health Survey. Patients improved on objective clinical measures of exercise capacity, cardiac ejection fraction, and ventricular dyssynchrony. Younger patients reported greater improvements in physical functioning and decreases in pain. Higher baseline body mass index was associated with less improvement in physical functioning. Finally, patients with nonischemic heart failure reported greater improvements on multiple subscales of the SF-36 than patients with ischemic heart failure. This preliminary study documented improvements in health-related quality of life following CRT. The findings highlight that specific patient characteristics may be associated with quality of life changes. Future studies will benefit from including quality of life measures that assess multiple health-related domains.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Insuficiencia Cardíaca/terapia , Calidad de Vida , Anciano , Anciano de 80 o más Años , Ecocardiografía , Electrocardiografía , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/psicología , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
18.
Pacing Clin Electrophysiol ; 25(12): 1715-23, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12520672

RESUMEN

The aim of this study was to describe the indications for upgrade of pacemakers (PMs) or single chamber (VVIR) ICDs to dual chamber (DDDR) ICDs, surgical approach, hardware hybridization, and clinical outcome. Patients with preexisting PMs or VVIR ICDs may develop indications for ICD therapy or dual chamber pacing, respectively, that can be served by DDDR ICDs that incorporate preexisting transvenous leads. Fifty-seven patients underwent upgrade from PMs (29/57) or VVIR ICDs (28/57) to pectoral DDDR ICDs. Preexisting transvenous atrial and/or ventricular leads suitable for continued use were incorporated into new DDDR ICDs in 88.5% and 100% of PM and VVIR ICD upgrades, respectively. Acceptable DFTs were achieved in 56 (98.2%) of 57 patients. Appropriate VT/VF therapies were registered among 33.3% of patients during follow-up. No shocks due to lead noise were observed in any patient with hybridized transvenous leads. Atrial far-field R wave (FFRW) oversensing occurred in 24% of DDDR ICD systems incorporating a preexisting atrial lead. FFRW was overcome by programming reduced atrial sensitivity without interfering with the normal ICD system performance in all instances. Upgrade of PMs and VVIR ICDs to pectoral DDDR ICDs is safe and technically feasible in most patients. Preexisting transvenous leads can be successfully incorporated into new DDDR ICDs, simplifying the surgical procedure, minimizing transvenous hardware, and eliminating the possibility of hazardous pacemaker-ICD interactions.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Tórax , Resultado del Tratamiento
19.
Card Electrophysiol Rev ; 6(4): 466-71, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12438830

RESUMEN

Management of the patient without inducible arrhythmias is dictated by the clinical setting in which the arrhythmias occur. Decisions must be based on whether the patient is being treated for symptomatic arrhythmias, or is undergoing evaluation of risk for potentially lethal arrhythmias. The management is influenced by the anatomic substrate, as well as the clinical presentation. As with all diagnostic tests, the significance of the electrophysiology study depends on the clinical context, and this type of test reflects but one mechanism for tachycardia. Finally, it is critical to remember that the results of published clinical trials can be used to guide management decisions, only when the same stimulation protocol utilized in the trials is employed, and the patient has the same characteristics as those enrolled in the trial.


Asunto(s)
Antiarrítmicos/uso terapéutico , Enfermedad Coronaria/diagnóstico , Técnicas Electrofisiológicas Cardíacas/métodos , Paro Cardíaco/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamiento farmacológico , Enfermedad Coronaria/mortalidad , Enfermedad Coronaria/terapia , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía Ambulatoria , Femenino , Paro Cardíaco/tratamiento farmacológico , Paro Cardíaco/prevención & control , Humanos , Masculino , Medición de Riesgo , Sensibilidad y Especificidad , Análisis de Supervivencia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/tratamiento farmacológico , Taquicardia Supraventricular/mortalidad , Taquicardia Ventricular/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA