Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Cardiothorac Vasc Anesth ; 38(7): 1467-1476, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38627172

RESUMEN

OBJECTIVE: To assess the intraoperative use of 3-dimensional transesophageal echocardiography (3D TEE) in cardiac surgical centers, the authors created a survey aimed at evaluating the availability of equipment and the use of 3D TEE for specific surgical and interventional procedures and single-image modalities. The respondents were asked to identify the perceived impact on patient management and current limitations to its routine use. DESIGN: A multiple choice 25-question online survey submitted to the members of the European Association of Cardiothoracic Anesthesia and Intensive Care (EACTAIC) on December 6, 2021, and closed on January 31, 2022. SETTING: An online survey. PARTICIPANTS: Registered EACTAIC members in 2021. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 239 respondents from 44 different countries took part in the survey (27% of the total 903 EACTAIC members). Most respondents (59%) were TEE-certified by the National Board of Echocardiography, European Association of Cardiovascular Imaging (EACVI/EACTAIC), or had a national certificate. Of the respondents, 68% had no formal 3D TEE training. Eight percent of respondents had no 3D machines, whereas 40% had one for each operating room, and 33% had only one for the entire operating room block. 3D TEE was performed most frequently in more than 67% of cases for mitral valve surgery, and in more than 54% of cases for mitral and tricuspid clips, aortic valve, tricuspid valve, and aortic surgery. CONCLUSION: Current guidelines suggest integrating 3D TEE into all comprehensive examinations. The authors' survey reported that intraoperative 3D TEE was used in the majority of mitral valve surgery and only one-half of the other valve surgeries and transcatheter procedures. Its use may be explained by the availability of 3D machines, trained personnel, and limited time to perform TEE in the operating room. Educational initiatives for training in 3D TEE may further increase its routine use.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Humanos , Ecocardiografía Transesofágica/métodos , Ecocardiografía Tridimensional/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Encuestas y Cuestionarios , Europa (Continente) , Anestesia en Procedimientos Quirúrgicos Cardíacos/métodos , Cuidados Críticos/métodos , Sociedades Médicas , Monitoreo Intraoperatorio/métodos
3.
Ann Thorac Surg ; 117(4): 669-689, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38284956

RESUMEN

Enhanced Recovery After Surgery (ERAS) programs have been shown to lessen surgical insult, promote recovery, and improve postoperative clinical outcomes across a number of specialty operations. A core tenet of ERAS involves the provision of protocolized evidence-based perioperative interventions. Given both the growing enthusiasm for applying ERAS principles to cardiac surgery and the broad scope of relevant interventions, an international, multidisciplinary expert panel was assembled to derive a list of potential program elements, review the literature, and provide a statement regarding clinical practice for each topic area. This article summarizes those consensus statements and their accompanying evidence. These results provide the foundation for best practice for the management of the adult patient undergoing cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Recuperación Mejorada Después de la Cirugía , Cirujanos , Cirugía Torácica , Humanos , Atención Perioperativa/métodos , Procedimientos Quirúrgicos Cardíacos/métodos
4.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38099912

RESUMEN

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Valor Predictivo de las Pruebas , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Anciano , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Tiempo , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Estudios de Factibilidad , Medición de Riesgo , Diseño de Prótesis , Ecocardiografía Tridimensional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA