Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Card Fail ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38851449

RESUMEN

BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (P = 0.89), nor was the pulmonary artery pulsatility index (PAPi) (P = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

2.
J Cardiovasc Electrophysiol ; 34(2): 412-417, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36583963

RESUMEN

AIMS: Leadless pacing has emerged as an alternative to conventional transvenous pacemakers to mitigate the risks of pocket- and lead-related complications but its use remains controversial in young adults mostly because experience in this patient population is limited. We sought to examine the feasibility and safety of implanting leadless single chamber pacemakers in young adults. METHODS: This multicenter, retrospective, observational study sought to evaluate the safety, efficacy, and electrical performance of the Micra VR Transcatheter Pacemaker System (Medtronic) in patients between 18 and 40 years who underwent implantation of a leadless pacemaker for any indication at the university medical centers of Bordeaux, Clermont-Ferrand, Toulouse, and Tours (France), between 2015 and 2021. The primary safety endpoint was freedom from system-related or procedure-related major complications at 6 months. The primary efficacy endpoint was the combination of a low (≤2 V) and stable (increase within 1.5 V) pacing capture threshold at 6 months. RESULTS: Leadless pacemaker implantation was successful in all 35 patients. At 6 months, safety endpoint was met for 35 (100%) and efficacy endpoint for 34 (97%) patients. During a follow-up of 26 ± 15 months (range: 6-60 months), Safety endpoint remained 100% and efficacy endpoint was 94%. Leadless pacemaker retrieval was not required in any patient. Approximately one-third of patients (n = 13, 37%) had >40% ventricular pacing burdens at 1 year, including all 10 patients with a complete AV block but also 3 patients with normal AV conduction during implantation. One patient reported symptoms of pacemaker syndrome which was confirmed using Holter recording and successfully treated using reprogramming. CONCLUSION: In this observational study, leadless pacemakers demonstrated favorable short- and intermediate-term safety and effectiveness in young adults.


Asunto(s)
Marcapaso Artificial , Humanos , Adulto Joven , Estudios Retrospectivos , Resultado del Tratamiento , Diseño de Equipo , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
3.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-34974497

RESUMEN

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Oxigenación por Membrana Extracorpórea/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Resultado del Tratamiento
4.
Nutr J ; 21(1): 2, 2022 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-34991613

RESUMEN

BACKGROUND: Chronic heart failure (CHF) is one of the most common causes of mortality in industrialized countries despite regular therapeutic advances. Numerous factors influence mortality in CHF patients, including nutritional status. It is known that malnutrition is a risk factor for mortality, whereas obesity may play a protective role, a phenomenon dubbed the "obesity paradox". However, the effect of the obesity-malnutrition association on mortality has not been previously studied for CHF. Our aim was to study the effect of nutritional status on overall mortality in CHF patients. METHODS: This retrospective, multicenter study was based on a French nationwide database (PMSI). We included all CHF patients aged ≥18 years admitted to all public and private hospitals between 2012 and 2016 and performed a survival analysis over 1 to 4 years of follow-up. RESULTS: Malnutrition led to a significant decrease in life expectancy in CHF patients when compared with normal nutritional status (aHR=1.16 [1.14-1.18] at one year and aHR=1.04 [1.004-1.08] at four years), obese, and obese-malnutrition groups. In contrast, obesity led to a significant increase in life expectancy compared with normal nutritional status (aHR=0.75 [0.73-0.78] at one year and aHR=0.85 [0.81-0.90] at four years), malnutrition, and obese-malnutrition groups. The mortality rate was similar in patients presenting both malnutrition and obesity and patients with normal nutritional status. CONCLUSIONS: Our results indicate that the protective effect on mortality observed in obese CHF patients seems to be linked to fat massincrease. Furthermore, malnourished obese and normal nutritional status patients had similar mortality rates. Further studies should be conducted to confirm our results and to explore the physiopathological mechanisms behind these effects.


Asunto(s)
Insuficiencia Cardíaca , Desnutrición , Adolescente , Adulto , Humanos , Estado Nutricional , Obesidad/epidemiología , Estudios Retrospectivos , Factores de Riesgo
5.
J Card Surg ; 37(11): 3477-3484, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36124420

RESUMEN

INTRODUCTION: With the expansion of the indication for transcatheter aortic valve implantation (TAVR), the value of access to on-site emergency heart surgery at performing centers needs to be assessed. AIMS: To evaluate postoperative mortality after surgical rescue post-TAVR, in a population at high surgical risk. METHODS: Retrospective analysis of a cohort of patients included in the France-TAVI registry who had undergone TAVR with the latest generation valves between January 2017 and February 2020. RESULTS: Among the 968 patients undergoing TAVR, 6 patients (0.62%) were identified as candidates for surgery: 3 in the peri-operative context and 3 during hospitalization. Four subjects were managed in a salvage situation, two due to tamponade, one due to aortic dissection, and one due to aortic annulus rupture. One patient died of a delayed aortic annulus rupture and one patient presented a right coronary occlusion which was medically treated. All patients who underwent emergency surgery were discharged alive from the hospital. CONCLUSIONS: In TAVR patients initially contraindicated for surgery, emergency bailout surgery could be performed successfully with all patients discharged alive. Access to on-site heart surgery represents a life-saving resource for TAVR centers.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
6.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-32998542

RESUMEN

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Asunto(s)
Desfibriladores Implantables/tendencias , Tetralogía de Fallot/epidemiología , Tetralogía de Fallot/terapia , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Sistema de Registros
7.
J Cardiovasc Electrophysiol ; 32(5): 1376-1384, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33625762

RESUMEN

INTRODUCTION: The evolution of atrioventricular conduction disorders after transcatheter aortic valve implantation (TAVI) remains poorly understood. We sought to identify factors associated with late (occurring ≥7 days after the procedure) high-grade atrioventricular blocks after TAVI, based on specific pacemaker memory data. METHODS AND RESULTS: STIM-TAVI (NCT03338582) was a prospective, multicentre, observational study that enrolled all patients (from November 2015 to January 2017) implanted with a specific dual chamber pacemaker after TAVI, with the SafeR algorithm activated, allowing continuous monitoring of atrioventricular conduction. The primary endpoint was the occurrence of centrally adjudicated late high-grade atrioventricular blocks during the year after TAVI. Among 197 patients, 138 (70.1%) had ≥1 late high-grade atrioventricular block. Whereas oversizing (p = .005), high-grade atrioventricular block during TAVI (p < .001), and early (within 6 days) high-grade atrioventricular block (p < .001) were associated with occurrence of late high-grade atrioventricular block, self-expanding prothesis (p = .88), prior right bundle branch block (p = .45), low implantation (p = .06), and new or wider left bundle branch block and lengthening of PR interval (p = .24) were not. In multivariable analysis, only post-TAVI early high-grade atrioventricular block remained associated with late high-grade atrioventricular blocks (Days 0-1: odds ratio [OR], 3.25; 95% confidence interval [CI], 1.57-6.74; p = .001; Days 2-6: OR, 4.13; 95% CI, 2.06-8.31; p < .001), whereas other conventionally used predictors were not. CONCLUSION: One-third of pacemaker-implanted patients do not experience late high-grade atrioventricular block. Our findings suggest that post-TAVI early high-grade atrioventricular block is the main factor associated with occurrence of late high-grade atrioventricular blocks.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Humanos , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 32(9): 2522-2527, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34270153

RESUMEN

BACKGROUND: Temporary transvenous pacing in critically ill patients requiring prolonged cardiac pacing is associated with a high risk of complications. We sought to evaluate the safety and efficacy of self-contained intracardiac leadless pacemaker (LPM) implantation in this population. METHODS AND RESULTS: Consecutive patients implanted with a Micra LPM during the hospitalization in an intensive care unit were retrospectively included. Inclusion criteria were: more than or equal to 1 supracaval central venous line, or a ventilation tube, or intravenous antibiotic therapy for ongoing sepsis or bacteremia. Patients with a history of the previous implantation of a pacemaker were excluded. Out of 1016 patients implanted with an LPM, 99 met the inclusion criteria. Mean age was 75 years and Charlson comorbidity index 7. LPM implantation was successfully performed in 98% of cases, with a perioperative complication rate of 5%, mainly cardiac injuries. In-hospital mortality rate was 6%. No late (>30 days) device-related complication occurred, especially no infection. CONCLUSIONS: LPM appears as an acceptable alternative to conventional temporary transvenous pacing in selected critically ill patients requiring prolonged cardiac pacing, especially regarding the risk of infection.


Asunto(s)
Enfermedad Crítica , Marcapaso Artificial , Anciano , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Diseño de Equipo , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
9.
Europace ; 23(1): 73-81, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33257972

RESUMEN

AIMS: We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. METHODS AND RESULTS: Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37-97) days. Median daily wear time of WCD was 23.4 (22.2-23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95-0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). CONCLUSION: Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.


Asunto(s)
Desfibriladores Implantables , Dispositivos Electrónicos Vestibles , Anciano , Estudios de Cohortes , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores , Cardioversión Eléctrica , Femenino , Francia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 31(6): 1493-1506, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32333433

RESUMEN

BACKGROUND: Morphology algorithms are currently recommended as a standalone discriminator in single-chamber implantable cardioverter defibrillators (ICDs). However, these proprietary algorithms differ in both design and nominal programming. OBJECTIVE: To compare three different algorithms with nominal versus advanced programming in their ability to discriminate between ventricular (VT) and supraventricular tachycardia (SVT). METHODS: In nine European centers, VT and SVTs were collected from Abbott, Boston Scientific, and Medtronic dual- and triple-chamber ICDs via their respective remote monitoring portals. Percentage morphology matches were recorded for selected episodes which were classified as VT or SVT by means of atrioventricular comparison. The sensitivity and related specificity of each manufacturer discriminator was determined at various values of template match percentage from receiving operating characteristics (ROC) curve analysis. RESULTS: A total of 534 episodes were retained for the analysis. In ROC analyses, Abbott Far Field MD (area under the curve [AUC]: 0.91; P < .001) and Boston Scientific RhythmID (AUC: 0.95; P < .001) show higher AUC than Medtronic Wavelet (AUC: 0.81; P < .001) when tested for their ability to discriminate VT from SVT. At nominal % match threshold all devices provided high sensitivity in VT identification, (91%, 100%, and 90%, respectively, for Abbott, Boston Scientific, and Medtronic) but contrasted specificities in SVT discrimination (85%, 41%, and 62%, respectively). Abbott and Medtronic's nominal thresholds were similar to the optimal thresholds. Optimization of the % match threshold improved the Boston Scientific specificity to 79% without compromising the sensitivity. CONCLUSION: Proprietary morphology discriminators show important differences in their ability to discriminate SVT. How much this impact the overall discrimination process remains to be investigated.


Asunto(s)
Algoritmos , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Procesamiento de Señales Asistido por Computador , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Telemetría/instrumentación , Potenciales de Acción , Diagnóstico Diferencial , Diseño de Equipo , Europa (Continente) , Frecuencia Cardíaca , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/terapia , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia
11.
Pacing Clin Electrophysiol ; 43(3): 332-340, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32039491

RESUMEN

BACKGROUND: Loss of biventricular stimulation can result in nonresponse to cardiac resynchronization therapy (CRT). Problems associated with the left ventricular (LV) lead and LV sensing can be challenging to detect and their incidence is unclear. The purpose of this study was to investigate mechanisms of loss of biventricular pacing due to LV lead- and LV sensing-associated problems. METHODS: In this bicentric study, CRT patients were surveilled using a novel remote monitoring algorithm from Biotronik (Germany) that registers LV electrograms (EGMs) during intermittent loss of resynchronization. The episodes were analyzed to assess the mechanisms of resynchronization interruptions. RESULTS: We analyzed 582 EGMs from 61 patients. During a median follow-up of 6 months, 59% of the patients had such episodes. The majority of the episodes (61%) were related to inappropriate inhibition of LV pacing, mostly due to upper rate lock-in caused by LV sensing (58%). In contrast, 8% of episodes showed intermittent loss of LV capture, which was identified thanks to LV sensing. The remaining 31% of episodes were due to physiological reasons for resynchronization interruptions (eg, supraventricular tachycardia [18%], premature beats [8%], and others [5%]). Patients with CRT interruption episodes had lower resynchronization rates (median: 98.5% vs 100%, P = .044). CONCLUSIONS: Inadequate programming (active LV sensing with T-wave protection) is the main cause of impaired resynchronization in devices with LV sensing. In general, we recommend the deactivation of the LV T-wave protection function.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Disfunción Ventricular Izquierda/terapia , Anciano , Algoritmos , Electrocardiografía , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio , Disfunción Ventricular Izquierda/fisiopatología
12.
Pacing Clin Electrophysiol ; 43(11): 1309-1317, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32627211

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead dysfunction has been reported after left ventricular assist device (LVAD) implantation in limited single-center studies. We aimed at describing and characterizing the incidence of ICD lead parameters dysfunction after LVAD implantation. METHODS: Among the 652 patients enrolled in the ASSIST-ICD study, only patients with an ICD prior to LVAD were included (n = 401). ICD lead parameters dysfunction following LVAD implantation is defined as follows: (a) >50% decrease in sensing threshold, (b) pacing lead impedance increase/decrease by >100Ω, and (c) >50% increase in pacing threshold. RESULTS: One hundred twenty-two patients with an ICD prior to LVAD had available ICD interrogation reports prior and after LVAD. A total of 67 (55%) patients exhibited at least one significant lead dysfunction: 17 (15%) exhibited >50% decrease in right ventricular (RV) sensing, 51 (42%) had >100 Ω increase/decrease in RV pacing impedance, and 24 (20%) experienced >50% increase in RV pacing threshold. A total of 52 patients experienced ventricular arrhythmia during follow-up and all were successfully detected and treated by the device. All lead dysfunction could be managed conservatively. CONCLUSION: More than 50% of LVAD-recipients may experience >1 significant change in lead parameters but none had severe clinical consequences.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Corazón Auxiliar , Anciano , Francia , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis
13.
J Electrocardiol ; 63: 6-11, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33011474

RESUMEN

OBJECTIVES: To determine the prognostic value of a low T/R ratio, defined as the amplitude ratio between the T waves and the R waves, in patients (pts) with a spontaneous type-1 Brugada pattern (SBT1). BACKGROUND: Abnormalities of myocardial repolarization may play a key role in the initiation of ventricular fibrillation (VF) in Brugada syndrome (BrS). Recent studies have shown that the height of the T waves and the T/R ratio are inversely proportional to sudden cardiac arrest (SCA) risk in early repolarization syndrome and hypertrophic cardiomyopathy. METHODS: In an international retrospective study, we reviewed 115 pts. (105 males, 91.3%). 45 had VF and/or SCA (38.7 ±â€¯11.5 years old, all males), while 70 (49.3 ±â€¯12.0 years, 10 women) remained free of ventricular arrhythmia. 6 ECG markers plus the T/R ratio in leads V5 & II were studied. RESULTS: The T/R ratio among leads II & V5 was significantly lower in the VF/SCA group (0.24 [0.14; 0.38]vs. 0.34 [0.24; 0.45]; p = 0.006). 44.4% of pts. in the VF/SCA group had a lowest T/R ratio among leads II & V5 ≤ 0.17 compared to 11.4% in the non-VF/SCA group (p < 0.001). In multivariate analysis, a lowest T/R ratio among leads II & V5 ≤ 0.17 was independently associated with VF/SCA (OR 6.10, 95% CI 1.92-19.40; p = 0.002). Type 1 Brugada pattern in the peripheral leads (OR 10.78) and early repolarization (OR 3.60) were other independent markers of VF/SCA. CONCLUSION: A low T/R ratio among leads II & V5 is an independent marker for VF/SCA risk in patients with type-1 Brugada pattern.


Asunto(s)
Síndrome de Brugada , Adulto , Síndrome de Brugada/diagnóstico , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Fibrilación Ventricular/diagnóstico
14.
Am Heart J ; 214: 69-76, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31174053

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Asunto(s)
Infecciones Relacionadas con Catéteres/etiología , Corazón Auxiliar/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Infecciones Relacionadas con Catéteres/mortalidad , Desfibriladores Implantables/estadística & datos numéricos , Remoción de Dispositivos/estadística & datos numéricos , Femenino , Francia/epidemiología , Ventrículos Cardíacos , Corazón Auxiliar/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Estudios Retrospectivos , Factores de Riesgo
15.
Europace ; 21(9): 1400-1409, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31177270

RESUMEN

AIMS: There is currently no reliable tool to quantify the risks of ventricular fibrillation or sudden cardiac arrest (VF/SCA) in patients with spontaneous Brugada type 1 pattern (BrT1). Previous studies showed that electrocardiographic (ECG) markers of depolarization or repolarization disorders might indicate elevated risk. We aimed to design a VF/SCA risk prediction model based on ECG analyses for adult patients with spontaneous BrT1. METHODS AND RESULTS: This retrospective multicentre international study analysed ECG data from 115 patients (mean age 45.1 ± 12.8 years, 105 males) with spontaneous BrT1. Of these, 45 patients had experienced VF/SCA and 70 patients did not experience VF/SCA. Among 10 ECG markers, a univariate analysis showed significant associations between VF/SCA and maximum corrected Tpeak-Tend intervals ≥100 ms in precordial leads (LMaxTpec) (P < 0.001), BrT1 in a peripheral lead (pT1) (P = 0.004), early repolarization in inferolateral leads (ER) (P < 0.001), and QRS duration ≥120 ms in lead V2 (P = 0.002). The Cox multivariate analysis revealed four predictors of VF/SCA: the LMaxTpec [hazard ratio (HR) 8.3, 95% confidence interval (CI) 2.4-28.5; P < 0.001], LMaxTpec + ER (HR 14.9, 95% CI 4.2-53.1; P < 0.001), LMaxTpec + pT1 (HR 17.2, 95% CI 4.1-72; P < 0.001), and LMaxTpec + pT1 + ER (HR 23.5, 95% CI 6-93; P < 0.001). Our multidimensional penalized spline model predicted the 1-year risk of VF/SCA, based on age and these markers. CONCLUSION: LMaxTpec and its association with pT1 and/or ER indicated elevated VF/SCA risk in adult patients with spontaneous BrT1. We successfully developed a simple risk prediction model based on age and these ECG markers.


Asunto(s)
Síndrome de Brugada/fisiopatología , Muerte Súbita Cardíaca/epidemiología , Electrocardiografía , Fibrilación Ventricular/epidemiología , Adulto , Factores de Edad , Síndrome de Brugada/complicaciones , Muerte Súbita Cardíaca/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Fibrilación Ventricular/etiología
16.
Circ J ; 82(3): 783-790, 2018 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-29199266

RESUMEN

BACKGROUND: Spontaneous reanalyzed coronary thrombus (SRCT) has been reported in autopsy series, but little is known about SRCT, and it is potentially under-diagnosed in clinical practice.Methods and Results:SRCT identified on OCT were included in a French multicenter series, the Lotus Root French Registry. A total of 34 SRCT were identified on OCT in 33 patients (23 male; median age, 56 years; IQR, 52-65 years); 23/33 patients (70%) presented with angina pectoris and/or dyspnea. Three angiographic aspects were distinguished retrospectively: braided, pseudo-dissected, and hazy. Stenosis severity on quantitative coronary analysis varied between 11% and 100% (median, 45%), whereas the reduction in lumen area on OCT varied between 20% and 92% (median, 68%). A typical "lotus root" aspect was confirmed on OCT, consisting of multiple circular concave-edged channels of varying size, numbering between 3 and 12 depending on the slice, separated by smooth-edged septa of high luminosity without posterior attenuation. OCT also served to guide treatment, with stenting in 91% of cases. During the 17-month follow-up 91% of patients had excellent evolution. One death and 3 ACS events occurred. CONCLUSIONS: In this large SRCT cohort, angiography had limited diagnostic value whereas OCT could be used to define disease characteristics and guide treatment of lesions inducing angina pectoris and/or silent myocardial ischemia. OCT-guided management was associated with good prognosis.


Asunto(s)
Trombosis Coronaria/diagnóstico , Trombosis Coronaria/terapia , Tomografía de Coherencia Óptica/métodos , Anciano , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/terapia , Angiografía Coronaria/normas , Trombosis Coronaria/diagnóstico por imagen , Manejo de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/terapia , Pronóstico , Sistema de Registros , Tomografía de Coherencia Óptica/normas
17.
Int J Clin Pharmacol Ther ; 56(8): 347-357, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29792395

RESUMEN

OBJECTIVE: The aim of this study was to assess the adherence of general practitioners (GPs) to guidelines in patients with heart failure with reduced ejection fraction (HFrEF) and to describe GPs' prescribing behavior regarding patients with heart failure with preserved ejection fraction (HFpEF). MATERIALS AND METHODS: Cross-sectional study as part of the ETIC trial. Five classes of drugs were described: angiotensin-converting enzyme inhibitors (ACEIs) or angiotensin receptor blockers (ARBs); ß-blockers (BBs); mineralocorticoid receptor antagonists (MRAs); diuretics (thiazide or loop diuretics); and digoxin. RESULTS: 178 patients were studied: their mean age was 73.5 years (± 10.6). Of the 128 patients with HFpEF, 81.3% received ACEIs or ARBs, 63.3% received BBs, 13.3% received MRAs, 75.8% received diuretics, and 12.5% received digoxin. Of the 50 patients with HFrEF, 84% received ACEIs or ARBs, 74% received BBs, 20% received MRAs, 76% received diuretics, and 2% received digoxin. 25% of the patients were given a drug in accordance with the recommendations for drug class but not a drug authorized for the HFrEF indication. Among the patients with HFrEF who were treated in accordance with the recommendations, target doses were achieved in 1/3 given ACEIs/ARBs, 1/4 given BBs, and 1/2 given MRAs. Only 6% of the patients had a perfect Global Adherence Indicator-3 (GAI-3) with all target doses achieved. CONCLUSION: Several drugs were prescribed even though they were not recommended, and few patients were treated optimally. It seems to be necessary to develop a pragmatic tool to help GPs and cardiologists in optimizing treatment.
.


Asunto(s)
Insuficiencia Cardíaca/terapia , Atención Primaria de Salud , Anciano , Anciano de 80 o más Años , Cardiólogos , Fármacos Cardiovasculares/uso terapéutico , Estudios Transversales , Utilización de Medicamentos , Femenino , Médicos Generales , Adhesión a Directriz , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Resultado del Tratamiento
18.
J Cardiovasc Magn Reson ; 19(1): 2, 2017 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-28063459

RESUMEN

BACKGROUND: Left ventricular (LV) remodeling following acute myocardial infarction (MI) is difficult to predict at an individual level although a possible interfering role of vascular function has yet to be considered to date. This study aimed to determine the extent to which this LV remodeling is influenced by the concomitant evolution of vascular function and LV loading conditions, as assessed by phase-contrast Cardiovascular Magnetic Resonance (CMR) of the ascending aorta. METHODS: CMR was performed in 121 patients, 2-4 days after reperfusion of a first ST-segment elevation myocardial infarction and 6 months thereafter. LV remodeling was: (i) assessed by the 6-month increase in end-diastolic volume (EDV) and/or ejection fraction (EF) and (ii) correlated with the indexed aortic stroke volume (mL.m-2), determined by a CMR phase-contrast sequence, along with derived functional vascular parameters (total peripheral vascular resistance (TPVR), total arterial compliance index, effective arterial elastance). RESULTS: At 6 months, most patients were under angiotensin enzyme converting inhibitors (86%) and beta-blockers (84%) and, on average, all functional vascular parameters were improved whereas blood pressure levels were not. An increase in EDV only (EDV+/EF-) was documented in 17% of patients at 6 months, in EF only (EDV-/EF+) in 31%, in both EDV and EF (EDV+/EF+) in 12% and neither EDV nor EF (EDV-/EF-) in 40%. The increase in EF was mainly and independently linked to a concomitant decline in TPVR (6-month change in mmHg.min.m2.L-1, EDV-/EF-: +1 ± 8, EDV+/EF-: +3 ± 9, EDV-/EF+: -7 ± 6, EDV+/EF+: -15 ± 20, p < 0.001) while the absence of any EF improvement was associated with high persisting rates of abnormally high TPVR at 6 months (EDV-/EF-: 31%, EDV+/EF-: 38%, EDV-/EF+: 5%, EDV+/EF+: 13%, p = 0.007). By contrast, the 6-month increase in EDV was mainly dependent on cardiac as opposed to vascular parameters and particularly on the presence of microvascular obstruction at baseline (EDV-/EF-: 37%, EDV+/EF-: 76%, EDV-/EF+: 38%, EDV+/EF+: 73%, p = 0.003). CONCLUSION: LV remodeling following reperfused MI is strongly influenced by the variable decrease in systemic vascular resistance under standard care vasodilating medication. The CMR monitoring of vascular resistance may help to tailor these medications for improving vascular resistance and consequently, LV ejection fraction. TRIAL REGISTRATION: NCT01109225 on ClinicalTrials.gov site (April, 2010).


Asunto(s)
Aorta/diagnóstico por imagen , Hemodinámica , Imagen por Resonancia Cinemagnética , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/terapia , Función Ventricular Izquierda , Remodelación Ventricular , Antagonistas Adrenérgicos beta/uso terapéutico , Anciano , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Aorta/efectos de los fármacos , Aorta/fisiopatología , Femenino , Hemodinámica/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/fisiopatología , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Resistencia Vascular , Vasodilatación , Vasodilatadores/uso terapéutico , Función Ventricular Izquierda/efectos de los fármacos , Remodelación Ventricular/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA