Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pancreatology ; 24(4): 624-629, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38580492

RESUMEN

Postoperative pancreatic fistula (POPF) is a major cause of morbidity and mortality after pancreatoduodenectomy (PD), and previous research has focused on patient-related risk factors and comparisons between anastomotic techniques. However, it is recognized that surgeon experience is an important factor in POPF outcomes, and that there is a significant learning curve for the pancreatic anastomosis. The aim of this study was to review the current literature on training models for the pancreatic anastomosis, and to explore areas for future research. It is concluded that research is needed to understand the mechanical properties of the human pancreas in an effort to develop a synthetic model that closely mimics its mechanical properties. Virtual reality (VR) is an attractive alternative to synthetic models for surgical training, and further work is needed to develop a VR pancreatic anastomosis training module that provides both high fidelity and haptic feedback.


Asunto(s)
Anastomosis Quirúrgica , Páncreas , Humanos , Páncreas/cirugía , Pancreaticoduodenectomía/educación , Fístula Pancreática/etiología , Fístula Pancreática/prevención & control , Realidad Virtual , Modelos Anatómicos
2.
Artículo en Inglés | MEDLINE | ID: mdl-39118448

RESUMEN

PURPOSE: To perform a systematic review and meta-analysis of the existing literature on meniscal centralisation procedures, analysing its impact on meniscal extrusion, joint biomechanics and clinical and radiological outcome measures. METHODS: The Cochrane Controlled Register of Trials, PubMed (MEDLINE) and Embase were used to perform a systematic review using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. Biomechanical studies on healthy animal or human cadaveric knee joints that assessed meniscal extrusion or tibiofemoral contact mechanics (contact area and pressure) following centralization for meniscal pathologies were included. For clinical studies, those that prospectively or retrospectively assessed patient-reported outcome measures (PROMs), postoperative knee motion, complications and radiological extrusion following centralization for meniscal pathologies were included. RESULTS: Fifteen studies were included in the analysis, comprising eight biomechanical, six clinical and one both. There were 92 knee specimens for biomechanical testing, of which 40 were human cadaveric and 52 porcine models. Biomechanical data revealed centralization to be commonly performed for posterior meniscal root tears and significantly reduced extrusion and contact pressure whilst improving contact area following a tear (p < 0.00001). Centralization restored extrusion to that of the native knee at all flexion angles described (0-90°, p = 0.25) and, compared to the torn state, brought tibiofemoral contact mechanics 3.2-5.0 times closer to the native state. Clinical data showed that 158 patients underwent centralization for extrusion. It improved postoperative Knee Injury and Osteoarthritis Outcome score (KOOS) (p = 0.006) and Lysholm scores (p < 0.00001) at 25.0 months, maintained extrusion reduction at 17.1 months (p < 0.00001) and preserved knee motion. CONCLUSION: Centralisation for various meniscal injuries associated with extrusion can reduce meniscal extrusion and improve joint biomechanics, along with clinical and radiological outcomes. Existing evidence is still scarce and exhibits a notable amount of methodological heterogeneity. LEVEL OF EVIDENCE: Systematic review of Level IV evidence.

3.
BMC Musculoskelet Disord ; 23(1): 228, 2022 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-35260135

RESUMEN

BACKGROUND: Articular cartilage is known to be a viscoelastic material, however little research has explored the impact of cartilage water content and bone density on its viscoelasticity. This study aimed to isolate subchondral bone density and hydration of articular cartilage and analyse their effects on the viscoelastic properties of articular cartilage. METHODS: Dynamic mechanical analysis was used to test samples at frequencies of 1, 8, 12, 29, 49, 71, and 88 Hz. Synthetic bone material with densities of 663.7 kg/m3 and 156.8 kg/m3 were used to mimic the bone mineral density (BMD). Dehydration occurred in a stepwise manner at relative humidity (RH) levels of 100%, 30%, and 1%. These relative humidity levels led to water contents of approximately 76%, 8.5%, and ≈ 0% by mass, respectively. RESULTS: Samples from eight bovine femoral heads were tested under a sinusoidal load. Storage stiffness was lower on the lower substrate density. Storage stiffness, though, increased as cartilage samples were dehydrated from a water content of 76% to 8.5%; decreasing again as the water content was further reduced. Loss stiffness was lower on a lower density substrate and decreased as the water content decreased. CONCLUSIONS: In conclusions, a decrease in hydration decreases the loss stiffness, but a non-linear relationship between hydration and storage stiffness may exist. Additionally, higher BMD values led to greater storage and loss stiffnesses.


Asunto(s)
Densidad Ósea , Cartílago Articular , Animales , Fenómenos Biomecánicos , Cartílago Articular/química , Cartílago Articular/diagnóstico por imagen , Bovinos , Elasticidad , Cabeza Femoral , Humanos
4.
Urban For Urban Green ; 68: 127457, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35002595

RESUMEN

The COVID-19 pandemic has produced alterations in the behaviour and psychological health of people, who have had to learn living under uncertain circumstances escaping their control. This situation has been aggravated in those countries applying strict home confinement rules to try bending their epidemic curve. This is the case of Spain, where the stringent lockdown period was extended over three months. This study aimed at proving a research hypothesis whereby living close to Green Infrastructure (GI) during the confinement period was beneficial for mental health. To this end, La Palma (Canary Islands) and Zaragoza (Peninsular Spain) were taken as case studies, since both locations distributed a questionnaire to address citizenry's self-reported mental health under strict lockdown conditions. A spatial statistical analysis of the responses collected by these questionnaires revealed that variables such as stress, anger, medication use, alcohol consumption or visits to the doctor significantly decreased if citizens were close to GI, whereas people having very high expectations of enjoying the city after the confinement were positively correlated to proximity of green areas. Although these outcomes are limited by the inferential capacity of correlation analysis, they point out to a sense of relief derived from having visual contact with vegetated landscapes and feeling stimulated about using them for recreation, aesthetical or sporting purposes. The joint consideration of these psychological gains with the social and environmental benefits provided by GI emphasizes the importance of approaching urban regeneration through the design and implementation of interconnected green spaces.

5.
Perfusion ; 36(3): 253-260, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32693675

RESUMEN

Strut chordae, on their own, are not typically thought to aid mitral valve competence. The aim of this study is to assess whether strut chordae aid mitral valve competence during acute annular dilation. Twelve porcine hearts were dissected and tested using an in vitro simulator, with the mitral annulus tested in either a 'normal' or a dilated configuration. The normal configuration included a diameter of 30 mm, a posterior leaflet 'radius' of 15 mm and a commissural corner 'radius' of 7.5 mm; the dilated annular template instead used dimensions of 50 mm, 25 mm and 12.5 mm, respectively. Each mitral valve underwent ten repeat tests with a target systolic pressure of 100 mmHg. No significant difference in the pressure was detected between the dilated and regular annuli for the mitral valves tested (95 ± 3 mmHg cf. 95 ± 2 mmHg). However, the volume of regurgitation for a dilated annulus was 28 ml greater than for a valve with a normal annulus. Following severing of strut chordae, there was a significant reduction in the systolic pressure withstood before regurgitation by mitral valves with dilated annuli (60 ± 29 mmHg cf. 95 ± 2 mmHg for normal annular dimensions; p < 0.05). In conclusion, strut chordae tendineae may play a role in aiding mitral valve competence during pathophysiology.


Asunto(s)
Insuficiencia de la Válvula Mitral , Válvula Mitral , Animales , Presión Sanguínea , Cuerdas Tendinosas , Dilatación , Porcinos
6.
J Anat ; 237(2): 209-224, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32242929

RESUMEN

The mitral valve is a complex anatomical structure whose physiological functioning relies on the biomechanical properties and structural integrity of its components. Their compromise can lead to mitral valve dysfunction, associated with morbidity and mortality. Therefore, a review on the morphometry of the mitral valve is crucial, more specifically on the importance of valve dimensions and shape for its function. This review initially provides a brief background on the anatomy and physiology of the mitral valve, followed by an analysis of the morphological information available. A characterisation of mathematical descriptions of several parts of the valve is performed and the impact of different dimensions and shape changes in disease is then outlined. Finally, a section regarding future directions and recommendations for the use of morphometric information in clinical analysis of the mitral valve is presented.


Asunto(s)
Válvula Mitral/anatomía & histología , Modelos Anatómicos , Fenómenos Biomecánicos/fisiología , Humanos , Válvula Mitral/fisiología
7.
BMC Musculoskelet Disord ; 20(1): 575, 2019 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-31785617

RESUMEN

BACKGROUND: Despite it being known that subchondral bone affects the viscoelasticity of cartilage, there has been little research into the mechanical properties of osteochondral tissue as a whole system. This study aims to unearth new knowledge concerning the dynamic behaviour of human subchondral bone and how energy is transferred through the cartilage-bone interface. METHODS: Dynamic mechanical analysis was used to determine the frequency-dependent (1-90 Hz) viscoelastic properties of the osteochondral unit (cartilage-bone system) as well as isolated cartilage and bone specimens extracted from human femoral heads obtained from patients undergoing total hip replacement surgery, with a mean age of 78 years (N = 5, n = 22). Bone mineral density (BMD) was also determined for samples using micro-computed tomography as a marker of tissue health. RESULTS: Cartilage storage and loss moduli along with bone storage modulus were found to increase logarithmically (p < 0.05) with frequency. The mean cartilage storage modulus was 34.4 ± 3.35 MPa and loss modulus was 6.17 ± 0.48 MPa (mean ± standard deviation). In contrast, bone loss modulus decreased logarithmically between 1 and 90 Hz (p < 0.05). The storage stiffness of the cartilage-bone-core was found to be frequency-dependent with a mean value of 1016 ± 54.0 N.mm- 1, while the loss stiffness was determined to be frequency-independent at 78.84 ± 2.48 N.mm- 1. Notably, a statistically significant (p < 0.05) linear correlation was found between the total energy dissipated from the isolated cartilage specimens, and the BMD of the isolated bone specimens at all frequencies except at 90 Hz (p = 0.09). CONCLUSIONS: The viscoelastic properties of the cartilage-bone core were significantly different to the tissues in isolation (p < 0.05). Results from this study demonstrate that the functionality of these tissues arises because they operate as a unit. This is evidenced through the link between cartilage energy dissipated and bone BMD. The results may provide insights into the functionality of the osteochondral unit, which may offer further understanding of disease progression, such as osteoarthritis (OA). Furthermore, the results emphasise the importance of studying human tissue, as bovine models do not always display the same trends.


Asunto(s)
Densidad Ósea/fisiología , Cartílago Articular/patología , Cartílago Articular/fisiología , Elasticidad/fisiología , Cuello Femoral/patología , Cuello Femoral/fisiología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos/fisiología , Femenino , Humanos , Masculino , Viscosidad
8.
Perfusion ; 34(3): 225-230, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30394849

RESUMEN

OBJECT: Mitral regurgitation (MR) is a condition in which the mitral valve does not prevent the reversal of blood flow from the left ventricle into the left atrium. This study aimed at numerically developing a model to mimic MR and poor leaflet coaptation and also comparing the performance of a normal mitral valve to that of the MR conditions at different gap junctions of 1, 3 and 5 mm between the anterior and posterior leaflets. RESULTS: The results revealed no blood flow to the left ventricle when a gap between the leaflets was 0 mm. However, MR increased this blood flow, with increases in the velocity and pressure within the atrium. However, the pressure within the aorta did not vary meaningfully (ranging from 22 kPa for a 'healthy' model to 25 kPa for severe MR). CONCLUSIONS: The findings from this study have implications not only for understanding the changes in pressure and velocity as a result of MR in the ventricle, atrium or aorta, but also for the development of a computational model suitable for clinical translation when diagnosing and determining treatment for MR.


Asunto(s)
Ventrículos Cardíacos/fisiopatología , Insuficiencia de la Válvula Mitral/fisiopatología , Válvula Mitral/fisiopatología , Velocidad del Flujo Sanguíneo , Presión Sanguínea , Simulación por Computador , Ventrículos Cardíacos/patología , Hemodinámica , Humanos , Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/patología , Modelos Cardiovasculares , Sístole
9.
J Environ Manage ; 242: 351-361, 2019 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-31054399

RESUMEN

Geographic Information Systems have been widely accepted to manage and manipulate spatial data associated with the hydrologic response of a watershed. Due to climate change and drought impacts, there is a need to conserve freshwater resources, which can be accomplished by introducing the concept of stormwater harvesting. Apart from hotspot identification and site screening, several economic, social, cultural, environmental aspects need to be considered before finalizing the suitable site for stormwater harvesting. The shortlisted sites are commonly ranked by considering various parameters, i.e. water demand, availability of stormwater and distance to end-use locations, which relate to economic aspects. In the present study, socio-environmental considerations are also constituted by adopting a web-GIS based approach. The geospatial datasets and metadata associated with the study area are organized as a repository in the open source database server (PostgreSQL/PostGIS), which is further assessed and analyzed by using GeoServer. This technique publishes the geospatial datasets to the public domain websites that can be accessed and visualized around the clock and across the world. This will help stakeholders gather and store responses from water planners and inhabitants, while minimizing the time and cost associated with field visits for collecting individual responses. In this respect, a questionnaire is prepared that includes queries associated with site selection and the responses are gathered from various institutions, water professionals, stakeholders and residents. Once the responses are collected, the Analytic Hierarchy Process has been implemented to compute the relative weights of each criterion with respect to the responses collected. The weights thus obtained assisted the planners in deciding the suitable stormwater harvesting site for Dehradun city in India. In context to responses gathered the sites 'B' and 'D' are given the maximum weightage to be the suitable sites in the study region. Also, the socio-environmental criteria such as 'community acceptance', 'recreational activities' and 'need for water reuse' have gathered the maximum weightage from the responses for the specific sites. Hence, the proposed methodology demonstrated how water professionals, civilians, planners, stakeholders and public can be included as participants in water-related decision making processes.


Asunto(s)
Sistemas de Información Geográfica , Lluvia , Ciudades , Hidrología , India
10.
BMC Musculoskelet Disord ; 19(1): 384, 2018 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-30355307

RESUMEN

BACKGROUND: Changes in bone mineral density have been implicated with the onset of osteoarthritis, but its role in inducing failure of articular cartilage mechanically is unclear. This study aimed to determine the effect of substrate density, as the underlying bone, on the surface damage of cartilage-off-bone, at frequencies associated with gait, and above. METHODS: Bovine articular cartilage samples were tested off-bone to assess induced damage with an indenter under a compressive sinusoidal load range of 5-50 N at frequencies of 1, 10 and 50 Hz, corresponding to normal and above normal gait respectively, for up to 10,000 cycles. Cartilage samples were tested on four underlying substrates with densities of 0.1556, 0.3222, 0.5667 and 0.6000 g/cm3. India ink was applied to identify damage as cracks, measured across their length using ImageJ software. Linear regression was performed to identify if statistical significance existed between substrate density, and surface damage of articular cartilage-off-bone, at all three frequencies investigated (p < 0.05). RESULTS: Surface damage significantly increased (p < 0.05) with substrate density at 10 Hz of applied frequency. Crack length at this frequency reached the maximum of 10.95 ± 9.12 mm (mean ± standard deviation), across all four substrates tested. Frequencies applied at 1 and 50 Hz failed to show a significant increase (p > 0.05) in surface damage with an increase in substrate density, at which the maximum mean crack length were 3.01 ± 3.41 mm and 5.65 ± 6.54 mm, respectively. Crack formation at all frequencies tended to form at the periphery of the cartilage specimen, with multiple straight-line cracking observed at 10 Hz, in comparison to single straight-line configurations produced at 1 and 50 Hz. CONCLUSIONS: The effect of substrate density on the surface damage of articular cartilage-off-bone is multi-factorial, with an above-normal gait frequency. At 1 Hz cartilage damage is not associated with substrate density, however at 10 Hz, it is. This study has implications on the effects of the factors that contribute to the onset of osteoarthritis.


Asunto(s)
Densidad Ósea/fisiología , Cartílago Articular/fisiología , Cabeza Humeral/fisiología , Animales , Cartílago Articular/anatomía & histología , Bovinos , Cabeza Humeral/anatomía & histología , Estrés Mecánico , Propiedades de Superficie
11.
BMC Musculoskelet Disord ; 17(1): 419, 2016 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-27716169

RESUMEN

BACKGROUND: The purpose of this study was to compare the frequency-dependent viscoelastic properties of human and bovine cartilage. METHODS: Full-depth cartilage specimens were extracted from bovine and human femoral heads. Using dynamic mechanical analysis, the viscoelastic properties of eight bovine and six human specimens were measured over the frequency range 1 Hz to 88 Hz. Significant differences between bovine and human cartilage viscoelastic properties were assessed using a Mann-Whitney test (p < 0.05). RESULTS: Throughout the range of frequencies tested and for both species, the storage modulus was greater than the loss modulus and both were frequency-dependent. The storage and loss moduli of all human and bovine cartilage specimens presented a logarithmic relationship with respect to frequency. The mean human storage modulus ranged from 31.9 MPa to 43.3 MPa, while the mean bovine storage modulus ranged from 54.0 MPa to 80.5 MPa; bovine storage moduli were 1.7 to 1.9 times greater than the human modulus. Similarly, the loss modulus of bovine cartilage was 2.0 to 2.1 times greater than human. The mean human loss modulus ranged from 5.3 MPa to 8.5 MPa while bovine moduli ranged from 10.6 MPa to 18.1 MPa. CONCLUSION: Frequency-dependent viscoelastic trends of bovine articular cartilage were consistent with those of human articular cartilage; this includes a similar frequency dependency and high-frequency plateau. Bovine cartilage was, however, 'stiffer' than human by a factor of approximately 2. With these provisos, bovine articular cartilage may be a suitable dynamic model for human articular cartilage.


Asunto(s)
Cartílago Articular/química , Elasticidad , Viscosidad , Anciano , Anciano de 80 o más Años , Animales , Fenómenos Biomecánicos , Bovinos , Femenino , Cabeza Femoral , Humanos , Modelos Biológicos , Estrés Fisiológico
12.
Perfusion ; 31(8): 683-690, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27484972

RESUMEN

A computational fluid dynamics model of a bicuspid aortic valve has been developed using idealised three-dimensional geometry. The aim was to compare how the orifice area and leaflet orientation affect the hemodynamics of a pure bicuspid valve. By applying physiologic material properties and boundary conditions, blood flow shear stresses were predicted during peak systole. A reduced orifice area altered blood velocity, the pressure drop across the valve and the wall shear stress through the valve. Bicuspid models predicted impaired blood flow similar to a stenotic valve, but the flow patterns were specific to leaflet orientation. Flow patterns developed in bicuspid aortic valves, such as helical flow, were sensitive to cusp orientation. In conclusion, the reduced opening area of a bicuspid aortic valve amplifies any impaired hemodynamics, but cusp orientation determines subsequent flow patterns which may determine the specific regions downstream from the valve most at risk of clinical complications.

13.
BMC Musculoskelet Disord ; 15: 205, 2014 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-24929249

RESUMEN

BACKGROUND: The knee is an incongruent joint predisposed to developing osteoarthritis, with certain regions being more at risk of cartilage degeneration even in non-osteoarthrosed joints.At present it is unknown if knee regions prone to cartilage degeneration have similar storage and/or loss stiffness, and frequency-dependent trends, to other knee joint cartilage. The aim of this study was to determine the range of frequency-dependent, viscoelastic stiffness of articular cartilage across the bovine knee joint. Such changes were determined at frequencies associated with normal and rapid heel-strike rise times. METHODS: Cartilage on bone, obtained from bovine knee joints, was tested using dynamic mechanical analysis (DMA). DMA was performed at a range of frequencies between 1 and 88 Hz (i.e. relevant to normal and rapid heel-strike rise times). Viscoelastic stiffness of cartilage from the tibial plateau, femoral condyles and patellar groove were compared. RESULTS: For all samples the storage stiffness increased, but the loss stiffness remained constant, with frequency. They were also dependent on cartilage thickness. Both the loss stiffness and the storage stiffness decreased with cartilage thickness. Femoral condyles had the thinnest cartilage but had the highest storage and loss stiffness. Tibial plateau cartilage not covered by the meniscus had the thickest cartilage and lowest storage and loss stiffness. CONCLUSION: Differences in regional thickness of knee joint cartilage correspond to altered frequency-dependent, viscoelastic stiffness.


Asunto(s)
Cartílago Articular/fisiología , Articulación de la Rodilla/fisiología , Animales , Fenómenos Biomecánicos , Cartílago Articular/ultraestructura , Bovinos , Elasticidad , Marcha , Técnicas In Vitro , Meniscos Tibiales/fisiología , Viscosidad , Soporte de Peso
14.
Biomech Model Mechanobiol ; 23(4): 1197-1207, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38483696

RESUMEN

Understanding the viscoelastic behavior of pediatric brain tissue is critical to interpret how external mechanical forces affect head injury in children. However, knowledge of the viscoelastic properties of pediatric brain tissue is limited, and this reduces the biofidelity of developed numeric simulations of the pediatric head in analysis of brain injury. Thus, it is essential to characterize the viscoelastic behavior of pediatric brain tissue in various loading conditions and to identify constitutive models. In this study, the pediatric porcine brain tissue was investigated in compression with determine the viscoelasticity under small and large strain, respectively. A range of frequencies between 0.1 and 40 Hz was applied to determine frequency-dependent viscoelastic behavior via dynamic mechanical analysis, while brain samples were divided into three strain rate groups of 0.01/s, 1/s and 10/s for compression up to 0.3 strain level and stress relaxation to obtain time-dependent viscoelastic properties. At frequencies above 20 Hz, the storage modulus did not increase, while the loss modulus increased continuously. With strain rate increasing from 0.01/s to 10/s, the mean stress at 0.1, 0.2 and 0.3 strain increased to approximate 6.8, 5.6 and 4.4 times, respectively. The brain compressive response was sensitive to strain rate and frequency. The characterization of brain tissue will be valuable for development of head protection systems and prediction of brain injury.


Asunto(s)
Encéfalo , Fuerza Compresiva , Elasticidad , Estrés Mecánico , Animales , Viscosidad , Encéfalo/fisiología , Factores de Tiempo , Porcinos , Sus scrofa , Módulo de Elasticidad
15.
R Soc Open Sci ; 11(6): 240383, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39100168

RESUMEN

This study aims to develop an automated framework for the characterization of materials which are both hyper-elastic and viscoelastic. This has been evaluated using human articular cartilage (AC). AC (26 tissue samples from 5 femoral heads) underwent dynamic mechanical analysis with a frequency sweep from 1 to 90 Hz. The conversion from a frequency- to time-domain hyper-viscoelastic material model was approximated using a modular framework design where finite element analysis was automated, and a genetic algorithm and interior point technique were employed to solve and optimize the material approximations. Three orders of approximation for the Prony series were evaluated at N = 1, 3 and 5 for 20 and 50 iterations of a genetic cycle. This was repeated for 30 simulations of six combinations of the above all with randomly generated initialization points. There was a difference between N = 1 and N = 3/5 of approximately ~5% in terms of the error estimated. During unloading the opposite was seen with a 10% error difference between N = 5 and 1. A reduction of ~1% parameter error was found when the number of generations increased from 20 to 50. In conclusion, the framework has proved effective in characterizing human AC.

16.
Biomed Eng Online ; 12: 122, 2013 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-24267976

RESUMEN

BACKGROUND: The aim of this study was to propose a method to estimate the maximum pressure in the left ventricle (MPLV) for a healthy subject, based on cardiac outputs measured by echo-Doppler (non-invasive) and catheterization (invasive) techniques at rest and during exercise. METHODS: Blood flow through aortic valve was measured by Doppler flow echocardiography. Aortic valve geometry was calculated by echocardiographic imaging. A Fluid-structure Interaction (FSI) simulation was performed, using an Arbitrary Lagrangian-Eulerian (ALE) mesh. Boundary conditions were defined as pressure loads on ventricular and aortic sides during ejection phase. The FSI simulation was used to determine a numerical relationship between the cardiac output to aortic diastolic and left ventricular pressures. This relationship enabled the prediction of pressure loads from cardiac outputs measured by invasive and non-invasive clinical methods. RESULTS: Ventricular systolic pressure peak was calculated from cardiac output of Doppler, Fick oximetric and Thermodilution methods leading to a 22%, 18% and 24% increment throughout exercise, respectively. The mean gradients obtained from curves of ventricular systolic pressure based on Doppler, Fick oximetric and Thermodilution methods were 0.48, 0.41 and 0.56 mmHg/heart rate, respectively. Predicted Fick-MPLV differed by 4.7%, Thermodilution-MPLV by 30% and Doppler-MPLV by 12%, when compared to clinical reports. CONCLUSIONS: Preliminary results from one subject show results that are in the range of literature values. The method needs to be validated by further testing, including independent measurements of intraventricular pressure. Since flow depends on the pressure loads, measuring more accurate intraventricular pressures helps to understand the cardiac flow dynamics for better clinical diagnosis. Furthermore, the method is non-invasive, safe, cheap and more practical. As clinical Fick-measured values have been known to be more accurate, our Fick-based prediction could be the most applicable.


Asunto(s)
Hemodinámica , Modelos Biológicos , Presión Ventricular , Adulto , Gasto Cardíaco/fisiología , Ejercicio Físico/fisiología , Humanos , Masculino , Oximetría , Descanso/fisiología
17.
Proc Inst Mech Eng H ; 237(7): 879-889, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37345411

RESUMEN

The purpose of this study was to create a preliminary set of experimentally validated Finite Element Analysis (FEA) models, in order to predict the dynamic mechanical behaviour of human articular cartilage (AC). Current models consider static loading with limited independent experimental validation, while the models for this study assess dynamic loading of AC, with direct comparison and validation to physical testing. Three different FEA models of AC were constructed, which considered both linear elastic and hyperelastic models; Neo-Hookean and Ogden. Models were validated using the data collected from compression testing of human femoral heads across 0-1.7 MPa (quasi-static tests and dynamic mechanical analysis). The linear elastic model was inadequate, with a 10-fold over prediction of the displacement dynamic amplitude. The Neo-Hookean model accurately predicted the dynamic amplitude but failed to predict the initial compression of the cartilage, with a 10 times overprediction. The Ogden model provided the best results, with both the initial compression lying within one standard deviation of that observed in the validation data set, and the dynamic amplitude of the same order of magnitude. In conclusion, this study has found that the fast dynamic response of human AC is best represented by a third order Ogden model.


Asunto(s)
Cartílago Articular , Humanos , Cartílago Articular/fisiología , Estrés Mecánico , Presión , Análisis de Elementos Finitos , Modelos Biológicos , Elasticidad , Fenómenos Biomecánicos
18.
Med Eng Phys ; 121: 104067, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37985031

RESUMEN

Mitral valve function depends on its complex geometry and tissue health, with alterations in shape and tissue response affecting the long-term restorarion of function. Previous computational frameworks for biomechanical assessment are mostly based on patient-specific geometries; however, these are not flexible enough to yield a variety of models and assess mitral closure for individually tuned morphological parameters or material property representations. This study details the finite element approach implemented in our previously developed toolbox to assess mitral valve biomechanics and showcases its flexibility through the generation and biomechanical evaluation of different models. A healthy valve geometry was generated and its computational predictions for biomechanics validated against data in the literature. Moreover, two mitral valve models including geometric alterations associated with disease were generated and analysed. The healthy mitral valve model yielded biomechanical predictions in terms of valve closure dynamics, leaflet stresses and papillary muscle and chordae forces comparable to previous computational and experimental studies. Mitral valve function was compromised in geometries representing disease, expressed by the presence of regurgitating areas, elevated stress on the leaflets and unbalanced subvalvular apparatus forces. This showcases the flexibility of the toolbox concerning the generation of a range of mitral valve models with varying geometric definitions and material properties and the evaluation of their biomechanics.


Asunto(s)
Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Válvula Mitral/fisiología , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Músculos Papilares/fisiología , Modelos Cardiovasculares
19.
Front Public Health ; 11: 1215574, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37457260

RESUMEN

Recurrent outbreaks of zoonotic infectious diseases highlight the importance of considering the interconnections between human, animal, and environmental health in disease prevention and control. This has given rise to the concept of One Health, which recognizes the interconnectedness of between human and animal health within their ecosystems. As a contribution to the One Health approach, this study aims to develop an indicator system to model the facilitation of the spread of zoonotic diseases. Initially, a literature review was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement to identify relevant indicators related to One Health. The selected indicators focused on demographics, socioeconomic aspects, interactions between animal and human populations and water bodies, as well as environmental conditions related to air quality and climate. These indicators were characterized using values obtained from the literature or calculated through distance analysis, geoprocessing tasks, and other methods. Subsequently, Multi-Criteria Decision-Making (MCDM) techniques, specifically the Entropy and Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) methods, were utilized to combine the indicators and create a composite metric for assessing the spread of zoonotic diseases. The final indicators selected were then tested against recorded zoonoses in the Valencian Community (Spain) for 2021, and a strong positive correlation was identified. Therefore, the proposed indicator system can be valuable in guiding the development of planning strategies that align with the One Health principles. Based on the results achieved, such strategies may prioritize the preservation of natural landscape features to mitigate habitat encroachment, protect land and water resources, and attenuate extreme atmospheric conditions.


Asunto(s)
Ecosistema , Salud Única , Animales , Humanos , Zoonosis/prevención & control , Brotes de Enfermedades , Atención a la Salud
20.
Proc Inst Mech Eng H ; 226(5): 389-96, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22720392

RESUMEN

This study investigates the rupture rate and morphology of articular cartilage by altering the bathing environments of healthy and degenerate bovine cartilage. Soaking tissues in either distilled water or 1.5 M NaCI saline was performed in order to render the tissues into a swollen or dehydrated state, respectively. Creep compression was applied using an 8 mm flat-ended polished indenter that contained a central pore of 450 microm in diameter, providing a consistent region for rupture to occur across all 105 tested specimens. Rupture rates were determined by varying the nominal compressive stress and the loading time. Similar rupture rates were observed with the swollen healthy and degenerate specimens, loaded with either 6 or 7MPa of nominal compressive stress over 11 and 13 min. The observed rupture rates for the dehydrated specimens loaded with 7 MPa over 60 and 90s were 20% versus 40% and 20% versus 60% for healthy and degenerate tissues, respectively. At 8 MPa of nominal compressive stress over 60 and 90s the observed rupture rates were 20% versus 60% and 40% versus 80% for healthy and degenerate tissues, respectively; with all dehydrated degenerate tissues exhibiting a greater tendency to rupture (Barnard's exact test, p < 0.05). Rupture morphologies were only different in the swollen degenerate tissues (p < 0.05). The mechanisms by which dehydration and swelling induce initial surface rupture of mildly degenerate articular cartilage differ. Dehydration increases the likelihood that the surface will rupture, however, swelling alters the observed rupture morphology.


Asunto(s)
Cartílago Articular/lesiones , Estrés Mecánico , Agua/metabolismo , Animales , Fenómenos Biomecánicos , Cartílago Articular/metabolismo , Cartílago Articular/patología , Bovinos , Rótula , Rotura/patología , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA