Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Vet Res ; 14(1): 72, 2018 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-29510691

RESUMEN

BACKGROUND: Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during anaesthesia would be beneficial for both the anaesthesia management and its outcome. New techniques for the monitoring of CO are aimed at finding methods which are non invasive, accurate and with good trending ability, which can be used in a clinical setting. The aim of this study was to compare the Pressure Recording Analytical Method (PRAM) with the pulmonary artery thermodilution (TD) for the measurement of cardiac output in 6 anaesthetized critically ill dogs. RESULTS: Fifty-four pairs of CO measurements were obtained with a median (range) of 3.33 L/min (0.81-7.21) for PRAM-CO and 3.48 L/min (1.41-6.56) for TD-CO. The Bland-Altman analysis showed a mean bias of 0.17 L/min with limits of agreement (LoA) of - 0.46 to 0.81 L/min. The percentage error resulted 18.2%. The 4-quadrant plot analysis showed an acceptable concordance (93%) between the 2 methods. The polar plot showed a good trending ability with the mean angular bias of 3.9° and radial LoA ± 12.1°. CONCLUSIONS: The PRAM resulted in good precision, acceptable concordance and good trending ability for the measure of CO in the anaesthetized dog, representing a promising alternative to thermodilution for the measurement of CO. Among all the pulse contour methods available on the market it is the only one that does not require any calibration or adjustment of the measurement. Further studies are required to verify the ability of this method to accurately measure cardiac output even during unstable hemodynamic conditions.


Asunto(s)
Gasto Cardíaco/fisiología , Perros/fisiología , Monitoreo Fisiológico/veterinaria , Anestesia General/métodos , Anestesia General/veterinaria , Animales , Presión Sanguínea/fisiología , Perros/cirugía , Femenino , Monitoreo Fisiológico/métodos , Pulso Arterial/veterinaria , Sepsis/fisiopatología , Sepsis/cirugía , Sepsis/veterinaria , Termodilución/veterinaria
2.
Front Vet Sci ; 10: 1135124, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37342619

RESUMEN

Dexmedetomidine is an alpha-2 adrenergic agonist, which use had an exponential increase in human and veterinary medicine in the last 10 years. The aim of this mini review is to summarize the various uses of dexmedetomidine underlining its new applications and capabilities in the small animals' clinical activity. While this drug was born as sedative in veterinary medicine, some studies demonstrated to be effective as an analgesic both in single administration and in continuous infusion. Recent studies have also shown the role of dexmedetomidine as an adjuvant during locoregional anesthesia, increasing the duration of the sensitive block and consequently decreasing the demand for systemic analgesics. The various analgesic properties make dexmedetomidine an interesting drug for opioid-free analgesia. Some studies highlighted a potential neuroprotective, cardioprotective and vasculoprotective role of dexmedetomidine, thus conferring it a place in critical care medicine, such as trauma and septic patients. Dexmedetomidine has demonstrated to be a multitasking molecule and it is ready to face new challenges.

3.
J Equine Vet Sci ; 79: 94-99, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31405509

RESUMEN

There has been increasing interest in blood gas analysis in donkeys. "Point-of-care (POC) testing" is a diagnostic testing performed on or immediately next to the patient. This study assesses the agreement between two POC blood gas analyzers in donkeys. Arterial and venous blood samples were collected from 17 donkeys and analyzed using a fully automated blood gas analyzer (ABL 700 Series Radiometer, Denmark) (RAD) and two POC blood gas analyzers (i-STAT System; VetStat, Idexx). The parameters revealed by all three devices were submitted to a canonical discriminant analysis, to evaluate which parameters differentiated the POC analyzers from the RAD. On the basis of the discriminant analysis, we evaluated the best POC for each parameter registered, in comparison with RAD. The results also changed depending on the type of blood (venous or arterial blood). The agreement between i-STAT and RAD was good for venous samples, but was poor for arterial samples. A poor agreement was found between VetStat and RAD for both venous and arterial samples. The increment of the number of subjects might lead to a better understanding of the potential role of the POCs in clinical setting. Finally, increasing the study population is recommended to set reference values.


Asunto(s)
Equidae , Sistemas de Atención de Punto , Animales , Análisis de los Gases de la Sangre/veterinaria , Pruebas en el Punto de Atención , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA