Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38781099

RESUMEN

AIMS: Cardioneuroablation (CNA) is a catheter-based intervention for recurrent vasovagal syncope (VVS) that consists in the modulation of the parasympathetic cardiac autonomic nervous system. This survey aims to provide a comprehensive overview of current CNA utilization in Europe. METHODS AND RESULTS: A total of 202 participants from 40 different countries replied to the survey. Half of the respondents have performed a CNA during the last 12 months, reflecting that it is considered a treatment option of a subset of patients. Seventy-one per cent of respondents adopt an approach targeting ganglionated plexuses (GPs) systematically in both the right atrium (RA) and left atrium (LA). The second most common strategy (16%) involves LA GP ablation only after no response following RA ablation. The procedural endpoint is frequently an increase in heart rate. Ganglionated plexus localization predominantly relies on an anatomical approach (90%) and electrogram analysis (59%). Less utilized methods include pre-procedural imaging (20%), high-frequency stimulation (17%), and spectral analysis (10%). Post-CNA, anticoagulation or antiplatelet therapy is prescribed, with only 11% of the respondents discharging patients without such medication. Cardioneuroablation is perceived as effective (80% of respondents) and safe (71% estimated <1% rate of procedure-related complications). Half view CNA emerging as a first-line therapy in the near future. CONCLUSION: This survey offers a snapshot of the current implementation of CNA in Europe. The results show high expectations for the future of CNA, but important heterogeneity exists regarding indications, procedural workflow, and endpoints of CNA. Ongoing efforts are essential to standardize procedural protocols and peri-procedural patient management.


Asunto(s)
Ablación por Catéter , Síncope Vasovagal , Humanos , Síncope Vasovagal/fisiopatología , Síncope Vasovagal/cirugía , Síncope Vasovagal/diagnóstico , Europa (Continente) , Ablación por Catéter/métodos , Flujo de Trabajo , Frecuencia Cardíaca , Resultado del Tratamiento , Encuestas de Atención de la Salud , Pautas de la Práctica en Medicina/tendencias , Técnicas Electrofisiológicas Cardíacas , Encuestas y Cuestionarios , Ganglios Autónomos/cirugía , Ganglios Autónomos/fisiopatología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Recurrencia
2.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38375690

RESUMEN

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) detects myocardial scarring, a risk factor for ventricular arrhythmias (VAs) in hypertrophic cardiomyopathy (HCM). The LGE-CMR distinguishes core, borderzone (BZ) fibrosis, and BZ channels, crucial components of re-entry circuits. We studied how scar architecture affects inducibility and electrophysiological traits of VA in HCM. METHODS AND RESULTS: We correlated scar composition with programmed ventricular stimulation-inducible VA features using LGE intensity maps. Thirty consecutive patients were enrolled. Thirteen (43%) were non-inducible, 6 (20%) had inducible non-sustained, and 11 (37%) had inducible sustained mono (MMVT)- or polymorphic VT/VF (PVT/VF). Of 17 induced VA, 13 (76%) were MMVT that either ended spontaneously, persisted as sustained monomorphic, or degenerated into PVT/VF. Twenty-seven patients (90%) had LGE. Of these, 17 (57%) had non-sustained or sustained inducible VA. Scar mass significantly increased (P = 0.002) from non-inducible to inducible non-sustained and sustained VA patients in both the BZ and core components. Borderzone channels were found in 23%, 67%, and 91% of non-inducible, inducible non-sustained, and inducible sustained VA patients (P = 0.003). All 13 patients induced with MMVT or monomorphic-initiated PVT/VF had LGE. The origin of 10/13 of these VTs matched scar location, with 8/10 of these LGE regions showing BZ channels. During follow-up (20 months, interquartile range: 7-37), one patient with BZ channels and inducible PVT had an ICD shock for VF. CONCLUSION: Scar architecture determines inducibility and electrophysiological traits of VA in HCM. Larger studies should explore the role of complex LGE patterns in refining risk assessment in HCM patients.


Asunto(s)
Cardiomiopatía Hipertrófica , Canal de Sodio Activado por Voltaje NAV1.5/deficiencia , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Cicatriz/complicaciones , Cicatriz/patología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Medios de Contraste , Gadolinio/farmacología , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones
3.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38652090

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Tomografía Computarizada Multidetector , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Atrios Cardíacos/cirugía , Atrios Cardíacos/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento , Recurrencia , Frecuencia Cardíaca , Potenciales de Acción
4.
Am Heart J ; 255: 94-105, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36272451

RESUMEN

BACKGROUND: Several electrocardiogram (ECG) criteria have been proposed to predict the location of the culprit occlusion in specific subsets of patients presenting with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to develop, through an independent validation of currently available criteria, a comprehensive and easy-to-use ECG algorithm, and to test its diagnostic performance in real-world clinical practice. METHODS: We analyzed ECG and angiographic data from 419 consecutive STEMI patients submitted to primary percutaneous coronary intervention over a one-year period, dividing the overall population into derivation (314 patients) and validation (105 patients) cohorts. In the derivation cohort, we tested >60 previously published ECG criteria, using the decision-tree analysis to develop the algorithm that would best predict the infarct-related artery (IRA) and its occlusion level. We further assessed the new algorithm diagnostic performance in the validation cohort. RESULTS: In the derivation cohort, the algorithm correctly predicted the IRA in 88% of cases and both the IRA and its occlusion level (proximal vs mid-distal) in 71% of cases. When applied to the validation cohort, the algorithm resulted in 88% and 67% diagnostic accuracies, respectively. In a real-world comparative test, the algorithm performed significantly better than expert physicians in identifying the site of the culprit occlusion (P = .026 vs best cardiologist and P < .001 vs best emergency medicine doctor). CONCLUSIONS: Derived from an extensive literature review, this comprehensive and easy-to-use ECG algorithm can accurately predict the IRA and its occlusion level in all-comers STEMI patients.


Asunto(s)
Oclusión Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico , Angiografía Coronaria , Infarto del Miocardio/diagnóstico , Electrocardiografía/métodos , Infarto del Miocardio con Elevación del ST/diagnóstico
5.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38011712

RESUMEN

AIMS: Epicardial adipose tissue might promote atrial fibrillation (AF) in several ways, including infiltrating the underlying atrial myocardium. However, the role of this potential mechanism has been poorly investigated. The aim of this study is to evaluate the presence of left atrial (LA) infiltrated adipose tissue (inFAT) by analysing multi-detector computer tomography (MDCT)-derived three-dimensional (3D) fat infiltration maps and to compare the extent of LA inFAT between patients without AF history, with paroxysmal, and with persistent AF. METHODS AND RESULTS: Sixty consecutive patients with AF diagnosis (30 persistent and 30 paroxysmal) were enrolled and compared with 20 age-matched control; MDCT-derived images were post-processed to obtain 3D LA inFAT maps for all patients. Volume (mL) and mean signal intensities [(Hounsfield Units (HU)] of inFAT (HU -194; -5), dense inFAT (HU -194; -50), and fat-myocardial admixture (HU -50; -5) were automatically computed by the software. inFAT volume was significantly different across the three groups (P = 0.009), with post-hoc pairwise comparisons showing a significant increase in inFAT volume in persistent AF compared to controls (P = 0.006). Dense inFAT retained a significant difference also after correcting for body mass index (P = 0.028). In addition, more negative inFAT radiodensity values were found in AF patients. Regional distribution analysis showed a significantly higher regional distribution of LA inFAT at left and right superior pulmonary vein antra in AF patients. CONCLUSION: Persistent forms of AF are associated with greater degree of LA intramyocardial adipose infiltration, independently of body mass index. Compared to controls, AF patients present higher LA inFAT volume at left and right superior pulmonary vein antra.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Atrios Cardíacos/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía , Ablación por Catéter/métodos
6.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37125968

RESUMEN

AIMS: Pulmonary vein (PV) antrum isolation proved to be effective for treating persistent atrial fibrillation (PeAF). We sought to investigate the results of a personalized approach aimed at adapting the ablation index (AI) to the local left atrial wall thickness (LAWT) in a cohort of consecutive patients with PeAF. METHODS AND RESULTS: Consecutive patients referred for PeAF first ablation were prospectively enrolled. The LAWT three-dimensional maps were obtained from pre-procedure multidetector computed tomography and integrated into the navigation system. Ablation index was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the PV antrum. A total of 121 patients (69.4% male, age 64.5 ± 9.5 years) were included. Procedure time was 57 min (IQR 50-67), fluoroscopy time was 43 s (IQR 20-71), and radiofrequency (RF) time was 16.5 min (IQR 14.3-18.4). The median AI tailored to the local LAWT was 387 (IQR 360-410) for the anterior wall and 335 (IQR 300-375) for the posterior wall. First-pass PV antrum isolation was obtained in 103 (85%) of the right PVs and 103 (85%) of the left PVs. Median LAWT values were higher for PVs without first-pass isolation as compared to the whole cohort (P = 0.02 for left PVs and P = 0.03 for right PVs). Recurrence-free survival was 79% at 12 month follow-up. CONCLUSION: In this prospective study, LAWT-guided PV antrum isolation for PeAF was effective and efficient, requiring low procedure, fluoroscopy, and RF time. A randomized trial comparing the LAWT-guided ablation with the standard of practice is in progress (ClinicalTrials.gov, NCT05396534).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Resultado del Tratamiento
7.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37724686

RESUMEN

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Asunto(s)
Cardiomiopatía Hipertrófica , Desfibriladores Implantables , Humanos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/terapia , Bradicardia , Progresión de la Enfermedad , Adenosina Trifosfato
8.
J Perinat Med ; 51(4): 550-558, 2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-36420537

RESUMEN

OBJECTIVES: Shone's complex (SC) is characterized by sequential obstructions of left ventricular (LV) inflow and outflow. It can be associated with poor long-term prognosis when compared to Simple-Aortic Coarctation (S-CoA). We aimed to assess whether the degree of ventricular disproportion and 2D-speckle-tracking echocardiography (2D-STE) could improve the accuracy of prenatal prediction of SC. METHODS: 75 consecutive fetuses were retrospectively enrolled from January 2010 to June 2021. Fetuses were divided into 4 groups (Group 1: SC; Group 2: S-CoA; Group 3: False Positive-Coarctation of the Aorta [FP-CoA]; group 4: controls). Comparisons for echocardiographic measures and myocardial deformation indices were performed. A receiver operating characteristic (ROC) analysis was performed on the MV/TV (mitral valve/tricuspid valve ratio) and LV GLS (global longitudinal strain) values to identify cut-offs to separate group 1 and 2 fetuses. RESULTS: SC fetuses showed a significant reduction in MV/TV when compared to S-CoA and FP-CoA fetuses (p<0.001). LV GLS in SC fetuses was significantly reduced compared to S-CoA fetuses (-13.3 ± 2.1% vs. -17.0 ± 2.2%, p=0.001). A cut-off value of 0.59 for MV/TV and -15.35% for LV GLS yielded a sensitivity of 76 and 82% and a specificity of 71 and 83% respectively in separating SC vs. S-CoA fetuses. CONCLUSIONS: SC fetuses showed a more severe degree of ventricular disproportion and a lower LV GLS compared to S-CoA, FP-CoA and control fetuses. MV/TV and GLS are both predictors of SC. These findings may improve the quality of prenatal parental counselling.


Asunto(s)
Coartación Aórtica , Embarazo , Femenino , Humanos , Estudios Retrospectivos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/complicaciones , Ecocardiografía , Curva ROC , Feto , Función Ventricular Izquierda
9.
Europace ; 24(6): 938-947, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-34849726

RESUMEN

AIMS: To non-invasively characterize, by means of late gadolinium enhancement cardiac magnetic resonance (LGE-CMR), scar differences, and potential variables associated with ventricular tachycardia (VT) occurrence in chronic post-myocardial infarction (MI) patients. METHODS AND RESULTS: A case-control study was designed through retrospective LGE-CMR data analysis of chronic post-MI patients (i) consecutively referred for VT substrate ablation after a first VT episode (n = 66) and (ii) from a control group (n = 84) with no arrhythmia evidence. The myocardium was characterized differentiating core, border zone (BZ), and BZ channels (BZCs) using the ADAS 3D post-processing imaging platform. Clinical and scar characteristics, including a novel parameter, the BZC mass, were compared between both groups. One hundred and fifty post-MI patients were included. Four multivariable Cox proportional hazards regression models were created for total scar mass, BZ mass, core mass, and BZC mass, adjusting them by age, sex, and left ventricular ejection fraction (LVEF). A cut-off of 5.15 g of BZC mass identified the cases with 92.4% sensitivity and 86.9% specificity [area under the ROC curve (AUC) 0.93 (0.89-0.97); P < 0.001], with a significant increase in the AUC compared to other scar parameters (P < 0.001 for all pairwise comparisons). Adding BZC mass to LVEF allowed to reclassify 33.3% of the cases and 39.3% of the controls [net reclassification improvement = 0.73 (0.71-0.74)]. CONCLUSIONS: The mass of BZC is the strongest independent variable associated with the occurrence of sustained monomorphic ventricular tachycardia in post-MI patients after adjustment for age, sex, and LVEF. Border zone channel mass measurement could permit a more accurate VT risk stratification than LVEF in chronic post-MI patients.


Asunto(s)
Infarto del Miocardio , Taquicardia Ventricular , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/etiología , Estudios de Casos y Controles , Cicatriz , Medios de Contraste , Gadolinio , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Estudios Retrospectivos , Volumen Sistólico , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/etiología , Función Ventricular Izquierda
10.
Artif Organs ; 46(8): 1608-1615, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35292988

RESUMEN

BACKGROUND: Ventricular arrhythmias (VAs) are observed in 25%-50% of continuous-flow left ventricular assist device (CF-LVAD) recipients, but their role on mortality is debated. METHODS: Sixty-nine consecutive patients with a CF-LVAD were retrospectively analyzed. Study endpoints were death and occurrence of first episode of VAs post CF-LVAD implantation. Early VAs were defined as VAs in the first month after CF-LVAD implantation. RESULTS: During a median follow-up of 29.0 months, 19 patients (27.5%) died and 18 patients (26.1%) experienced VAs. Three patients experienced early VAs, and one of them died. Patients with cardiac resynchronization therapy (CRT-D) showed a trend toward more VAs (p = 0.076), compared to patients without CRT-D; no significant difference in mortality was found between patients with and without CRT-D (p = 0.63). Patients with biventricular (BiV) pacing ≥98% experienced more frequently VAs (p = 0.046), with no difference in mortality (p = 0.56), compared to patients experiencing BiV pacing <98%. There was no difference in mortality among patients with or without VAs after CF-LVAD [5 patients (27.8%) vs. 14 patients (27.5%), p = 0.18)], and patients with or without previous history of VAs (p = 0.95). Also, there was no difference in mortality among patients with a different timing of implant of implantable cardioverter-defibrillator (ICD), before and after CF-LVAD (p = 0.11). CONCLUSIONS: VAs in CF-LVAD are a common clinical problem, but they do not impact mortality. Timing of ICD implantation does not have a significant impact on patients' survival. Patients with BiV pacing ≥98% experienced more frequently VAs.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Corazón Auxiliar , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
11.
J Cardiovasc Electrophysiol ; 32(5): 1337-1345, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33682256

RESUMEN

BACKGROUND: Ventricular arrhythmias (VAs) are rare in pediatric patients, especially in absence of structural heart disease (SHD). Few data are available regarding the invasive VAs treatment with catheter ablation (CA) in pediatric patients and predictors of outcomes have not been fully investigated. OBJECTIVE: To describe the clinical presentation, procedural characteristics, and outcomes in pediatric patients undergoing CA for VAs. METHODS: Eighty-one consecutive pediatric patients (58 male [72%], 15.5 ± 2.2 years) treated by CA for ventricular tachycardia (VT) or premature ventricular beats (PVBs) were retrospectively evaluated. Study endpoints were VAs recurrence and mortality for any cause. RESULTS: Ninety-five procedures were performed in 81 patients, 52 (55%) PVBs and 43 (45%) VT ablations. During a follow-up of 35.0 months (interquartile range = 13.0-71.0), 14 patients (14.7%) had a VA recurrence: 11 (33.3%) patients treated with CA for VT and 3 (6.2%) patients treated for PVBs (p < .001). One patient (1%) died 26 months after the procedure during an electrical storm. Patients with SHD had higher VAs recurrence rate, as compared with idiopathic VAs (pairwise log-rank p < .001). Patients treated with CA for VT had higher VA recurrence rate, as compared with PVB patients (pairwise log-rank p = .002). At Cox multivariate analysis only SHD was an independent predictor of VAs recurrence (hazard ratio = 5.56, 95% confidence interval = 2.68-11.54, p < .001). CONCLUSION: CA of VAs is effective and safe in a pediatric population. CA of idiopathic and fascicular VAs are associated with lower recurrence rate, than VAs in the setting of SHD.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Ablación por Catéter/efectos adversos , Niño , Humanos , Masculino , Recurrencia , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 32(12): 3179-3186, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34664762

RESUMEN

BACKGROUND: Myxomatous mitral valve prolapse (MVP) and mitral-annular disjunction (Barlow disease) are at-risk for ventricular arrhythmias (VA). Fibrosis involving the papillary muscles and/or the infero-basal left ventricular (LV) wall was reported at autopsy in sudden cardiac death (SCD) patients with MVP. OBJECTIVES: We investigated the electrophysiological substrate subtending VA in MVP patients with Barlow disease phenotype. METHODS: Twenty-three patients with VA were enrolled, including five with syncope and four with a history of SCD. Unipolar (Uni < 8.3 mV) and bipolar (Bi < 1.5 mV) low-voltage areas were analyzed with electro-anatomical mapping (EAM), and VA inducibility was evaluated with programmed ventricular stimulation (PES). Electrophysiological parameters were correlated with VA patterns, electrocardiogram (ECG) inferior negative T wave (nTW), and late gadolinium enhancement (LGE) assessed by cardiac magnetic resonance. RESULTS: Premature ventricular complex (PVC) burden was 12 061.9 ± 12 994.6/24 h with a papillary-muscle type (PM-PVC) in 18 patients (68%). Twelve-lead ECG showed nTW in 12 patients (43.5%). A large Uni less than 8.3 mV area (62.4 ± 45.5 cm2 ) was detected in the basal infero-lateral LV region in 12 (73%) patients, and in the papillary muscles (2.2 ± 2.9 cm2 ) in 5 (30%) of 15 patients undergoing EAM. A concomitant Bi less than 1.5 mV area (5.0 ± 1.0 cm2 ) was identified in two patients. A history of SCD, and the presence of nTW, and LGE were associated with a greater Uni less than 8.3 mV extension: (32.8 ± 3.1 cm2 vs. 9.2 ± 8.7 cm2 ), nTW (20.1 ± 11.0 vs. 4.1 ± 3.8 cm2 ), and LGE (19.2 ± 11.7 cm2 vs. 1.0 ± 2.0 cm2 , p = .013), respectively. All patients with PM-PVC had a Uni less than 8.3 mV area. Sustained VA (ventricular tachycardia 2 and VF 2) were induced by PES only in four patients (one with resuscitated SCD). CONCLUSIONS: Low unipolar low voltage areas can be identified with EAM in the basal inferolateral LV region and in the papillary muscles as a potential electrophysiological substrate for VA and SCD in patients with MVP and Barlow disease phenotype.


Asunto(s)
Prolapso de la Válvula Mitral , Complejos Prematuros Ventriculares , Medios de Contraste , Gadolinio , Humanos , Prolapso de la Válvula Mitral/complicaciones , Músculos Papilares
13.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
14.
Rev Cardiovasc Med ; 22(4): 1383-1392, 2021 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-34957778

RESUMEN

Ventricular arrhythmias still represent an important cause of morbidity and mortality, especially in patients with heart failure and reduced left ventricular ejection fraction. Amiodarone is a Class III Vaughan-Williams anti-arrhythmic drug widely used in ventricular arrhythmias for its efficacy and low pro-arrhythmogenic effect. On the other hand, a significant limitation in its use is represented by toxicity. In this review, the pharmacology of the drug is discussed to provide the mechanistic basis for its clinical use. Moreover, all the latest evidence on its role in different clinical settings is provided, including the prevention of sudden cardiac death, implanted cardioverter defibrillators, ischemic and non-ischemic cardiomyopathies. A special focus is placed on everyday clinical practice learning points, such as dosage, indications, and contraindications from the latest guidelines.


Asunto(s)
Amiodarona , Desfibriladores Implantables , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamiento farmacológico , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Humanos , Volumen Sistólico , Función Ventricular Izquierda
15.
Catheter Cardiovasc Interv ; 98(1): E163-E170, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33797142

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the impact of edge-to-edge PMVR on short and mid-term clinical outcomes in patients with CS and severe MR. BACKGROUND: Severe mitral regurgitation (MR) in the setting of cardiogenic shock (CS) is associated with three times higher risk of 1-year mortality. In refractory CS, edge-to-edge percutaneous mitral valve repair (PMVR) can be a potential therapeutic option. METHODS: We retrospectively included consecutive patients with refractory CS and concomitant severe MR treated with MitraClip® system. CS was defined according to the criteria used in the SHOCK trial and procedural success according to Mitral Valve Academic Research Consortium (MVARC) criteria. The 30-day and 6-month mortality were the primary and secondary endpoints respectively. RESULTS: Thirty-one patients (median age 73 years [interquartile range, IQR 66-78], 25.8% female), STS mortality score 37.9 [IQR 30.4-42.4]), with CS and concomitant severe MR treated with edge-to-edge PMVR were retrospectively enrolled. Procedural success was 87.1%. Thirty-day and 6-month survival rates were 78.4 and 45.2% respectively. Univariate Cox Regression Model analysis showed that procedural success was a predictor of both 30-day (HR = 0.12, 95% CI 0.03-0.55, p < .01) and 6-month survival (HR = 0.22, 95% CI 0.06-0.84, p = .027). CONCLUSIONS: Edge-to-edge PMVR in patients with CS and concomitant severe MR was associated with good procedural safety and success with acceptable short and mid-term survival rates. It could be considered a bailout option in this setting of patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
16.
Artif Organs ; 45(6): 569-576, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33277695

RESUMEN

Extracorporeal membrane oxygenation (ECMO) represents a therapeutic option for cardiopulmonary support in patients with high-risk pulmonary embolism (PE); however, no definite consensus exists on ECMO use in high-risk PE. Hence, we aim to provide insights into its real-world use pooling together all available published experiences. We performed a systematic review and pooled analysis of all published studies (up to April 17, 2020) investigating ECMO support in high-risk PE. All studies including at least four patients were collectively analyzed. Study outcomes were early all-cause death (primary endpoint) and relevant in-hospital adverse events. A total of 21 studies were included in the pooled analysis (n = 635 patients). In this population (mean age 47.8 ± 17.3 years, 44.5% females), ECMO was indicated for cardiac arrest in 62.3% and immediate ECMO support was pursued in 61.9% of patients. Adjunctive reperfusion therapies were implemented in 57.0% of patients. Pooled estimate rate of early all-cause mortality was 41.1% (95% CI 27.7%-54.5%). The most common in-hospital adverse event was major bleeding, with an estimated rate of 28.6% (95%CI 21.0%-36.3%). At meta-regression analyses, no significant impact of multiple covariates on the primary endpoint was found. In this systematic review of patients who received ECMO for high-risk PE, pooled all-cause mortality was 41.1%. Principal indication for ECMO was cardiac arrest, cannulation was chiefly performed at presentation, and major bleeding was the most common complication.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Embolia Pulmonar/terapia , Enfermedad Aguda , Humanos
17.
Echocardiography ; 37(12): 2071-2081, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33026122

RESUMEN

AIMS: Aortic stenosis (AS) grading by 2D-transthoracic echocardiography (2D-TTE) aortic valve area (AVA) calculation is limited by left ventricular outflow tract (LVOT) area underestimation. The combination of Doppler parameters with 3D LVOT area obtained by multidetector computed tomography (MDCT) can improve AS grading, reconciling discordant 2D-TTE findings. This study aimed to systematically evaluate the role of 3D-transesophageal echocardiography (3D-TEE) in AS grading using MDCT as reference standard. METHODS AND RESULTS: 288 patients (81 ± 6.3 years, 52.4% female) with symptomatic AS underwent 2D-TTE, 3D-TEE, and MDCT for transcatheter aortic valve implantation. Doppler parameters were combined with 3D LVOT areas measured by manual and semi-automated software 3D-TEE and by MDCT to calculate AVA, reassessing AS severity. Both 3D-TEE modalities demonstrated good correlation with MDCT, with excellent intra-observer and inter-observer variability. Compared to MDCT, 3D-TEE measurements significantly underestimated AVA (PANOVA  < .0001), although the difference was clinically acceptable. Compared to 2D-TTE, 3D-TEE manual and semi-automated software reclassified severe AS in 21.9% and 25.2% of cases, respectively (P < .0001), overcame grading parameters discordance in more than 40% of cases in patients with low-gradient AS (P < .0001) and reduced the proportion of low-flow states in nearly 75% of cases when combined to stroke volume index assessment (P < .0001). 3D-TEE imaging modalities showed a reduction in the proportion of patients with low-gradient and pathological AVA as defined by 2D-TTE, and improved AVA and mean pressure gradient agreement with current guidelines cutoff values. CONCLUSION: 3D-TEE AVA calculation is a reliable tool for AS grading with excellent reproducibility and good correlation with MDCT measurements.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía Tridimensional , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados
20.
Ann Cardiothorac Surg ; 13(1): 31-43, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38380136

RESUMEN

Atrial fibrillation (AF) is the most common arrhythmia in the adult population and catheter ablation has emerged as an important rhythm-control strategy and is the most common cardiac ablation procedure performed worldwide. The antiarrhythmic drugs have demonstrated moderate efficacy in long-term maintenance of sinus rhythm; moreover, they are often not tolerated and are associated with adverse events. Catheter ablation has proven to be effective in treating AF, although long-term outcomes have been significantly less favorable in persistent AF than in paroxysmal. The current guidelines recommend catheter ablation as class I indication for patients whom antiarrhythmic drugs have failed or are not tolerated, and as first-line rhythm-control therapy in selected patients with symptomatic AF. Advances in technology and innovative ablation protocols resulted in a remarkable improvement of the efficacy outcomes after pulmonary vein isolation. This review seeks to provide an updated report of the current practices and approaches, and to describe the latest advances in technology that aim to improve procedural safety, efficacy and to reduce procedural requirements in terms of duration and fluoroscopy exposure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA