Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Respir Res ; 25(1): 232, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38834976

RESUMEN

AIM: Acute respiratory distress syndrome or ARDS is an acute, severe form of respiratory failure characterised by poor oxygenation and bilateral pulmonary infiltrates. Advancements in signal processing and machine learning have led to promising solutions for classification, event detection and predictive models in the management of ARDS. METHOD: In this review, we provide systematic description of different studies in the application of Machine Learning (ML) and artificial intelligence for management, prediction, and classification of ARDS. We searched the following databases: Google Scholar, PubMed, and EBSCO from 2009 to 2023. A total of 243 studies was screened, in which, 52 studies were included for review and analysis. We integrated knowledge of previous work providing the state of art and overview of explainable decision models in machine learning and have identified areas for future research. RESULTS: Gradient boosting is the most common and successful method utilised in 12 (23.1%) of the studies. Due to limitation of data size available, neural network and its variation is used by only 8 (15.4%) studies. Whilst all studies used cross validating technique or separated database for validation, only 1 study validated the model with clinician input. Explainability methods were presented in 15 (28.8%) of studies with the most common method is feature importance which used 14 times. CONCLUSION: For databases of 5000 or fewer samples, extreme gradient boosting has the highest probability of success. A large, multi-region, multi centre database is required to reduce bias and take advantage of neural network method. A framework for validating with and explaining ML model to clinicians involved in the management of ARDS would be very helpful for development and deployment of the ML model.


Asunto(s)
Aprendizaje Automático , Síndrome de Dificultad Respiratoria , Humanos , Valor Predictivo de las Pruebas , Síndrome de Dificultad Respiratoria/clasificación , Síndrome de Dificultad Respiratoria/diagnóstico , Síndrome de Dificultad Respiratoria/terapia
2.
Crit Care Med ; 48(3): e200-e208, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31809278

RESUMEN

OBJECTIVES: Determine the intra-tidal regional gas and blood volume distributions at different levels of atelectasis in experimental lung injury. Test the hypotheses that pulmonary aeration and blood volume matching is reduced during inspiration in the setting of minimal tidal recruitment/derecruitment and that this mismatching is an important determinant of hypoxemia. DESIGN: Preclinical study. SETTING: Research laboratory. SUBJECTS: Seven anesthetized pigs 28.7 kg (SD, 2.1 kg). INTERVENTIONS: All animals received a saline-lavage surfactant depletion lung injury model. Positive end-expiratory pressure was varied between 0 and 20 cm H2O to induce different levels of atelectasis. MEASUREMENTS AND MAIN RESULTS: Dynamic dual-energy CT images of a juxtadiaphragmatic slice were obtained, gas and blood volume fractions within three gravitational regions calculated and normalized to lung tissue mass (normalized gas volume and normalized blood volume, respectively). Ventilatory conditions were grouped based upon the fractional atelectatic mass in expiration (< 20%, 20-40%, and ≥ 40%). Tidal recruitment/derecruitment with fractional atelectatic mass in expiration greater than or equal to 40% was less than 7% of lung mass. In this group, inspiration-related increase in normalized gas volume was greater in the nondependent (818 µL/g [95% CI, 729-908 µL/g]) than the dependent region (149 µL/g [120-178 µL/g]). Normalized blood volume decreased in inspiration in the nondependent region (29 µL/g [12-46 µL/g]) and increased in the dependent region (39 µL/g [30-48 µL/g]). Inspiration-related changes in normalized gas volume and normalized blood volume were negatively correlated in fractional atelectatic mass in expiration greater than or equal to 40% and 20-40% groups (r = 0.56 and 0.40), but not in fractional atelectatic mass in expiration less than 20% group (r = 0.01). Both the increase in normalized blood volume in the dependent region and fractional atelectatic mass in expiration negatively correlated with PaO2/FIO2 ratio (ρ = -0.77 and -0.93, respectively). CONCLUSIONS: In experimental atelectasis with minimal tidal recruitment/derecruitment, mechanical inspiratory breaths redistributed blood volume away from well-ventilated areas, worsening PaO2/FIO2.


Asunto(s)
Lesión Pulmonar/terapia , Respiración con Presión Positiva/efectos adversos , Atelectasia Pulmonar/terapia , Circulación Pulmonar/fisiología , Respiración Artificial/métodos , Algoritmos , Animales , Modelos Animales de Enfermedad , Mecánica Respiratoria , Porcinos , Volumen de Ventilación Pulmonar
3.
Br J Anaesth ; 124(3): 345-353, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31952649

RESUMEN

BACKGROUND: Bedside lung volume measurement could personalise ventilation and reduce driving pressure in patients with acute respiratory distress syndrome (ARDS). We investigated a modified gas-dilution method, the inspired sinewave technique (IST), to measure the effective lung volume (ELV) in pigs with uninjured lungs and in an ARDS model. METHODS: Anaesthetised mechanically ventilated pigs were studied before and after surfactant depletion by saline lavage. Changes in PEEP were used to change ELV. Paired measurements of absolute ELV were taken with IST (ELVIST) and compared with gold-standard measures (sulphur hexafluoride wash in/washout [ELVSF6] and computed tomography (CT) [ELVCT]). Measured volumes were used to calculate changes in ELV (ΔELV) between PEEP levels for each method (ΔELVIST, ΔELVSF6, and ΔELVCT). RESULTS: The coefficient of variation was <5% for repeated ELVIST measurements (n=13 pigs). There was a strong linear relationship between ELVIST and ELVSF6 in uninjured lungs (r2=0.97), and with both ELVSF6 and ELVCT in the ARDS model (r2=0.87 and 0.92, respectively). ELVIST had a mean bias of -12 to 13% (95% limits=±17 - 25%) compared with ELVSF6 and ELVCT. ΔELVIST was concordant with ΔELVSF6 and ΔELVCT in 98-100% of measurements, and had a mean bias of -73 to -77 ml (95% limits=±128 - 186 ml) compared with ΔELVSF6 and -1 ml (95% limits ±333 ml) compared with ΔELVCT. CONCLUSIONS: IST provides a repeatable measure of absolute ELV and shows minimal bias when tracking PEEP-induced changes in lung volume compared with CT in a saline-lavage model of ARDS.


Asunto(s)
Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Animales , Modelos Animales de Enfermedad , Mediciones del Volumen Pulmonar/métodos , Pruebas en el Punto de Atención , Reproducibilidad de los Resultados , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/etiología , Síndrome de Dificultad Respiratoria/fisiopatología , Solución Salina , Sus scrofa , Tomografía Computarizada por Rayos X
4.
Br J Anaesth ; 123(2): 126-134, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30954237

RESUMEN

BACKGROUND: Cardiac output (Q˙) monitoring can support the management of high-risk surgical patients, but the pulmonary artery catheterisation required by the current 'gold standard'-bolus thermodilution (Q˙T)-has the potential to cause life-threatening complications. We present a novel noninvasive and fully automated method that uses the inspired sinewave technique to continuously monitor cardiac output (Q˙IST). METHODS: Over successive breaths the inspired nitrous oxide (N2O) concentration was forced to oscillate sinusoidally with a fixed mean (4%), amplitude (3%), and period (60 s). Q˙IST was determined in a single-compartment tidal ventilation lung model that used the resulting amplitude/phase of the expired N2O sinewave. The agreement and trending ability of Q˙IST were compared with Q˙T during pharmacologically induced haemodynamic changes, before and after repeated lung lavages, in eight anaesthetised pigs. RESULTS: Before lung lavage, changes in Q˙IST and Q˙T from baseline had a mean bias of -0.52 L min-1 (95% confidence interval [CI], -0.41 to -0.63). The concordance between Q˙IST and Q˙T was 92.5% as assessed by four-quadrant analysis, and polar plot analysis revealed a mean angular bias of 5.98° (95% CI, -24.4°-36.3°). After lung lavage, concordance was slightly reduced (89.4%), and the mean angular bias widened to 21.8° (-4.2°, 47.6°). Impaired trending ability correlated with shunt fraction (r=0.79, P<0.05). CONCLUSIONS: The inspired sinewave technique provides continuous and noninvasive monitoring of cardiac output, with a 'marginal-good' trending ability compared with cardiac output based on thermodilution. However, the trending ability can be reduced with increasing shunt fraction, such as in acute lung injury.


Asunto(s)
Gasto Cardíaco , Monitoreo Fisiológico/métodos , Animales , Modelos Animales , Óxido Nitroso , Porcinos , Termodilución/métodos
5.
Exp Physiol ; 103(5): 738-747, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29460470

RESUMEN

NEW FINDINGS: What is the central question of this study? We present a new non-invasive medical technology, the inspired sine-wave technique, which involves inhalation of sinusoidally fluctuating concentrations of a tracer gas. The technique requires only passive patient cooperation and can monitor different cardiorespiratory variables, such as end-expired lung volume, ventilatory heterogeneity and pulmonary blood flow. What is the main finding and its importance? In this article, we demonstrate that the measurements of end-expired lung volume are repeatable and accurate, in comparison to whole-body plethysmography, and the technique is sensitive to the changes in ventilatory heterogeneity associated with advancing age. As such, it has the potential to provide clinically valuable information. ABSTRACT: The inspired sine-wave technique (IST) is a new method that can provide simple, non-invasive cardiopulmonary measurements. Over successive tidal breaths, the concentration of a tracer gas (i.e. nitrous oxide, N2 O) is sinusoidally modulated in inspired air. Using a single-compartment tidal-ventilation lung model, the resulting amplitude/phase of the expired sine wave allows estimation of end-expired lung volume (ELV), pulmonary blood flow and three indices for ventilatory heterogeneity (VH; ELV180 /FRCpleth , ELV180 /FRCpred and ELV60 /ELV180 ). This investigation aimed to determine the repeatability and agreement of ELV with FRCpleth and, as normal ageing results in well-established changes in pulmonary structure and function, whether the IST estimates of ELV and VH are age dependent. Forty-eight healthy never-smoker participants (20-86 years) underwent traditional pulmonary function testing (e.g. spirometry, body plethysmography) and the IST test, which consisted of 4 min of quiet breathing through a face mask while inspired N2 O concentrations were oscillated in a sine-wave pattern with a fixed mean (4%) and amplitude (3%) and a period of either 180 or 60 s. The ELV180 /FRCpleth and ELV180 /FRCpred were age dependent (average decreases of 0.58 and 0.48% year-1 ), suggesting an increase in VH with advancing age. The ELV showed a mean bias of -1.09 litres versus FRCpleth , but when normalized for the effects of age this bias reduced to -0.35 litres. The IST test has potential to provide clinically useful information necessitating further study (e.g. for mechanically ventilated or obstructive lung disease patients), but these findings suggest that the increases in VH with healthy ageing must be taken into account in clinical investigations.


Asunto(s)
Pulmón/fisiología , Volumen de Ventilación Pulmonar/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento/fisiología , Femenino , Humanos , Mediciones del Volumen Pulmonar/métodos , Masculino , Persona de Mediana Edad , Alveolos Pulmonares/fisiología , Flujo Sanguíneo Regional/fisiología , Respiración , Pruebas de Función Respiratoria/métodos , Espirometría , Adulto Joven
6.
Sci Rep ; 14(1): 4897, 2024 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-38418516

RESUMEN

The inspired sinewave technique (IST) is a non-invasive method to measure lung heterogeneity indices (including both uneven ventilation and perfusion or heterogeneity), which reveal multiple conditions of the lung and lung injury. To evaluate the reproducibility and predicted clinical outcomes of IST heterogeneity values, a comparison with a quantitative lung computed tomography (CT) scan is performed. Six anaesthetised pigs were studied after surfactant depletion by saline-lavage. Paired measurements of lung heterogeneity were then taken with both the IST and CT. Lung heterogeneity measured by the IST was calculated by (a) the ratio of tracer gas outputs measured at oscillation periods of 180 s and 60 s, and (b) by the standard deviation of the modelled log-normal distribution of ventilations and perfusions in the simulation lung. In the CT images, lungs were manually segmented and divided into different regions according to voxel density. A quantitative CT method to calculate the heterogeneity (the Cressoni method) was applied. The IST and CT show good Pearson correlation coefficients in lung heterogeneity measurements (ventilation: 0.71, and perfusion, 0.60, p < 0.001). Within individual animals, the coefficients of determination average ventilation (R2 = 0.53) and perfusion (R2 = 0.68) heterogeneity. Strong concordance rates of 98% in ventilation and 89% when the heterogeneity changes were reported in pairs measured by CT scanning and IST methods. This quantitative method to identify heterogeneity has the potential to replicate CT lung heterogeneity, and to aid individualised care in ARDS.


Asunto(s)
Pulmón , Síndrome de Dificultad Respiratoria , Porcinos , Animales , Reproducibilidad de los Resultados , Pulmón/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Modelos Animales , Tomografía Computarizada por Rayos X/métodos
7.
Intensive Care Med Exp ; 11(1): 60, 2023 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-37672140

RESUMEN

BACKGROUND: Within-breath oscillations in arterial oxygen tension (PaO2) can be detected using fast responding intra-arterial oxygen sensors in animal models. These PaO2 signals, which rise in inspiration and fall in expiration, may represent cyclical recruitment/derecruitment and, therefore, a potential clinical monitor to allow titration of ventilator settings in lung injury. However, in hypovolaemia models, these oscillations have the potential to become inverted, such that they decline, rather than rise, in inspiration. This inversion suggests multiple aetiologies may underlie these oscillations. A correct interpretation of the various PaO2 oscillation morphologies is essential to translate this signal into a monitoring tool for clinical practice. We present a pilot study to demonstrate the feasibility of a new analysis method to identify these morphologies. METHODS: Seven domestic pigs (average weight 31.1 kg) were studied under general anaesthesia with muscle relaxation and mechanical ventilation. Three underwent saline-lavage lung injury and four were uninjured. Variations in PEEP, tidal volume and presence/absence of lung injury were used to induce different morphologies of PaO2 oscillation. Functional principal component analysis and k-means clustering were employed to separate PaO2 oscillations into distinct morphologies, and the cardiorespiratory physiology associated with these PaO2 morphologies was compared. RESULTS: PaO2 oscillations from 73 ventilatory conditions were included. Five functional principal components were sufficient to explain ≥ 95% of the variance of the recorded PaO2 signals. From these, five unique morphologies of PaO2 oscillation were identified, ranging from those which increased in inspiration and decreased in expiration, through to those which decreased in inspiration and increased in expiration. This progression was associated with the estimates of the first functional principal component (P < 0.001, R2 = 0.88). Intermediate morphologies demonstrated waveforms with two peaks and troughs per breath. The progression towards inverted oscillations was associated with increased pulse pressure variation (P = 0.03). CONCLUSIONS: Functional principal component analysis and k-means clustering are appropriate to identify unique morphologies of PaO2 waveform associated with distinct cardiorespiratory physiology. We demonstrated novel intermediate morphologies of PaO2 waveform, which may represent a development of zone 2 physiologies within the lung. Future studies of PaO2 oscillations and modelling should aim to understand the aetiologies of these morphologies.

8.
EBioMedicine ; 76: 103868, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35172957

RESUMEN

BACKGROUND: The manufacturing of any standard mechanical ventilator cannot rapidly be upscaled to several thousand units per week, largely due to supply chain limitations. The aim of this study was to design, verify and perform a pre-clinical evaluation of a mechanical ventilator based on components not required for standard ventilators, and that met the specifications provided by the Medicines and Healthcare Products Regulatory Agency (MHRA) for rapidly-manufactured ventilator systems (RMVS). METHODS: The design utilises closed-loop negative feedback control, with real-time monitoring and alarms. Using a standard test lung, we determined the difference between delivered and target tidal volume (VT) at respiratory rates between 20 and 29 breaths per minute, and the ventilator's ability to deliver consistent VT during continuous operation for >14 days (RMVS specification). Additionally, four anaesthetised domestic pigs (3 male-1 female) were studied before and after lung injury to provide evidence of the ventilator's functionality, and ability to support spontaneous breathing. FINDINGS: Continuous operation lasted 23 days, when the greatest difference between delivered and target VT was 10% at inspiratory flow rates >825 mL/s. In the pre-clinical evaluation, the VT difference was -1 (-90 to 88) mL [mean (LoA)], and positive end-expiratory pressure (PEEP) difference was -2 (-8 to 4) cmH2O. VT delivery being triggered by pressures below PEEP demonstrated spontaneous ventilation support. INTERPRETATION: The mechanical ventilator presented meets the MHRA therapy standards for RMVS and, being based on largely available components, can be manufactured at scale. FUNDING: Work supported by Wellcome/EPSRC Centre for Medical Engineering,King's Together Fund and Oxford University.


Asunto(s)
Diseño de Equipo , Respiración Artificial/instrumentación , Animales , COVID-19/patología , COVID-19/prevención & control , COVID-19/virología , Femenino , Masculino , Frecuencia Respiratoria , SARS-CoV-2/aislamiento & purificación , Porcinos , Volumen de Ventilación Pulmonar
9.
Artículo en Inglés | MEDLINE | ID: mdl-33654391

RESUMEN

BACKGROUND: There is marked variability in the symptoms and outcomes of patients with chronic obstructive pulmonary disease (COPD) which are poorly predicted by spirometry/FEV1%pred. Furthermore, as spirometry requires the performance of potentially distressing respiratory manoeuvres which are to some extent user-effort dependent, there is need for non-invasive and simple-to-perform techniques to identify subtypes of COPD which are more closely related to clinically relevant outcomes. MATERIALS AND METHODS: The inspired sinewave test (IST) sinusoidally modulates the inspired concentration of a tracer gas (N2O) over successive tidal breaths. A single-compartment tidal-ventilation lung model processes the amplitude/phase of the expired N2O sinewave and estimates cardiopulmonary variables including: effective lung volume and indices of ventilatory heterogeneity (VH; ELV180/FRCpleth and ELV180/ELVpred). 83 COPD patients and 53 healthy controls performed the IST test, standard pulmonary function tests (Spirometry, body plethysmography and the single breath test of carbon monoxide uptake), and symptom severity questionnaires (COPD assessment test, CAT; mMRC dyspnoea-scale, mMRC-DS; Cough+Mucus score; C+M score). RESULTS: ELV180/FRCpleth and ELV180/ELVpred were significantly lower in patients with COPD vs healthy participants (0.34±0.11 vs 0.68±0.14 and 0.7±0.27 vs 0.98±0.15, respectively; P<0.05). Multivariable regression analysis demonstrated that ELV180/FRCpleth was a stronger and independent predictor of CAT, mMRC-DS and C+M score vs FEV1%pred. ELV180/ELVpred was a stronger and independent and better predictor of C+M score vs FEV1%pred. Phenotyping patients, based upon ELV180/ELVpred and FRC%pred, uncovered significant symptomatic differences between groups. CONCLUSION: The IST indices of VH were superior and independent predictors of symptom severity vs FEV1%pred and has potential as a non-invasive and simple-to-perform method to stratify patients into subgroups related to clinically relevant features of COPD.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Disnea , Volumen Espiratorio Forzado , Humanos , Pulmón , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Pruebas de Función Respiratoria , Espirometría
10.
Artículo en Inglés | MEDLINE | ID: mdl-34891243

RESUMEN

Patients undergoing mechanical lung ventilation are at risk of lung injury. A noninvasive bedside lung monitor may benefit these patients. The Inspired Sinewave Test (IST) can measure cardio-pulmonary parameters noninvasively. We propose a lung simulation to improve the measurement of pulmonary blood flow using IST. The new method was applied to 12 pigs' data before lung injury (control) and after lung injury (ARDS model). Results using the lung simulation shown improvements in correlation in both simulated data (R2 increased from 0.98 to 1) and pigs' data (R2 increased from <0.001 to 0.26). Paired blood flow measurements were performed by both the IST (noninvasive) and thermodilution (invasive). In the control group, the bias of the two methods was negligible (0.02L/min), and the limit of agreement was from -1.20 to 1.18 L/min. The bias was -0.68 L/min in the ARDS group and with a broader limit of agreement (-2.49 to 1.13 L/min).Clinical Relevance- the inspired sinewave test can be used to measure cardiac output noninvasively in mechanically ventilated subjects with and without acute respiratory distress syndrome.


Asunto(s)
Circulación Pulmonar , Síndrome de Dificultad Respiratoria , Animales , Humanos , Pulmón , Síndrome de Dificultad Respiratoria/diagnóstico , Pruebas de Función Respiratoria , Porcinos , Termodilución
11.
Intensive Care Med Exp ; 9(1): 3, 2021 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-33496887

RESUMEN

BACKGROUND: Bedside measurement of lung volume may provide guidance in the personalised setting of respiratory support, especially in patients with the acute respiratory distress syndrome at risk of ventilator-induced lung injury. We propose here a novel operator-independent technique, enabled by a fibre optic oxygen sensor, to quantify the lung volume available for gas exchange. We hypothesised that the continuous measurement of arterial partial pressure of oxygen (PaO2) decline during a breath-holding manoeuvre could be used to estimate lung volume in a single-compartment physiological model of the respiratory system. METHODS: Thirteen pigs with a saline lavage lung injury model and six control pigs were studied under general anaesthesia during mechanical ventilation. Lung volumes were measured by simultaneous PaO2 rate of decline (VPaO2) and whole-lung computed tomography scan (VCT) during apnoea at different positive end-expiratory and end-inspiratory pressures. RESULTS: A total of 146 volume measurements was completed (range 134 to 1869 mL). A linear correlation between VCT and VPaO2 was found both in control (slope = 0.9, R2 = 0.88) and in saline-lavaged pigs (slope = 0.64, R2 = 0.70). The bias from Bland-Altman analysis for the agreement between the VCT and VPaO2 was - 84 mL (limits of agreement ± 301 mL) in control and + 2 mL (LoA ± 406 mL) in saline-lavaged pigs. The concordance for changes in lung volume, quantified with polar plot analysis, was - 4º (LoA ± 19°) in control and - 9° (LoA ± 33°) in saline-lavaged pigs. CONCLUSION: Bedside measurement of PaO2 rate of decline during apnoea is a potential approach for estimation of lung volume changes associated with different levels of airway pressure.

12.
Physiol Meas ; 41(11)2020 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-33049721

RESUMEN

Acute respiratory distress syndrome (ARDS) is associated with a high rate of morbidity and mortality, as patients undergoing mechanical ventilation are at risk of ventilator-induced lung injuries.Objective: To measure the lung heterogeneity and deadspace volume to find safer ventilator strategies. The ventilator settings could then offer homogeneous ventilation and theoretically equalize and reduce tidal strain/stress in the lung parenchyma.Approach: The inspired sinewave test (IST) is a non-invasive lung measurement tool which does not require cooperation from the patient. The IST can measure the effective lung volume, pulmonary blood flow and deadspace volume. We developed a computational simulation of the cardiopulmonary system to allow lung heterogeneity to be quantified using data solely derived from the IST. Then, the method to quantify lung heterogeneity using two IST tracer gas frequencies (180 and 60 s) was introduced and used in lung simulations and animal models. Thirteen anaesthetized pigs were studied with the IST both before and after experimental lung injury (saline-lavage ARDS model). The deadspace volume was compared between the IST and the SF6washout method.Main results: The IST could measure lung heterogeneity using two tracer gas frequencies. Furthermore, the value of IST ventilation heterogeneity in ARDS lungs was higher than in control lungs at a positive end-expiratory pressure of 10 cmH2O (area under the curve = 0.85,p<0.001). Values for the deadspace volume measured by the IST have a strong relationship with the measured values of SF6(9 ml bias and limits of agreement from -79 to 57 ml in control animals).Significance: The IST technique has the potential for use in the identification of ventilation and perfusion heterogeneity during ventilator support.


Asunto(s)
Síndrome de Dificultad Respiratoria , Animales , Humanos , Pulmón , Mediciones del Volumen Pulmonar , Respiración con Presión Positiva , Respiración Artificial , Síndrome de Dificultad Respiratoria/diagnóstico , Síndrome de Dificultad Respiratoria/terapia , Pruebas de Función Respiratoria , Porcinos , Volumen de Ventilación Pulmonar
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 2438-2441, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-33018499

RESUMEN

We have created a lung simulation to quantify lung heterogeneity from the results of the inspired sinewave test (IST). The IST is a lung function test that is non-invasive, non-ionising and does not require patients' cooperation. A tidal lung simulation is developed to assess this test and also a method is proposed to calculate lung heterogeneity from IST results. A sensitivity analysis based on the Morris method and linear regression were applied to verify and to validate the simulation. Additionally, simulated emphysema and pulmonary embolism conditions were created using the simulation to assess the ability of the IST to identify these conditions. Experimental data from five pigs (pre-injured vs injured) were used for validation. This paper contributes to the development of the IST. Firstly, our sensitivity analysis reveals that the IST is highly accurate with an underestimation of about 5% of the simulated values. Sensitivity analysis suggested that both instability in tidal volume and extreme expiratory flow coefficients during the test cause random errors in the IST results. Secondly, the ratios of IST results obtained at two tracer gas oscillation frequencies can identify lung heterogeneity (ELV60/ELV180 and Qp60/Qp180). There was dissimilarity between simulated emphysema and pulmonary embolism (p < 0.0001). In the animal model, the control group had ELV60/ELV180 = 0.58 compared with 0.39 in injured animals (p < 0.0001).


Asunto(s)
Pulmón , Animales , Humanos , Pruebas de Función Respiratoria , Porcinos , Volumen de Ventilación Pulmonar
14.
ACS Nano ; 14(10): 12313-12340, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-32866368

RESUMEN

Personal protective equipment (PPE) is critical to protect healthcare workers (HCWs) from highly infectious diseases such as COVID-19. However, hospitals have been at risk of running out of the safe and effective PPE including personal protective clothing needed to treat patients with COVID-19, due to unprecedented global demand. In addition, there are only limited manufacturing facilities of such clothing available worldwide, due to a lack of available knowledge about relevant technologies, ineffective supply chains, and stringent regulatory requirements. Therefore, there remains a clear unmet need for coordinating the actions and efforts from scientists, engineers, manufacturers, suppliers, and regulatory bodies to develop and produce safe and effective protective clothing using the technologies that are locally available around the world. In this review, we discuss currently used PPE, their quality, and the associated regulatory standards. We survey the current state-of-the-art antimicrobial functional finishes on fabrics to protect the wearer against viruses and bacteria and provide an overview of protective medical fabric manufacturing techniques, their supply chains, and the environmental impacts of current single-use synthetic fiber-based protective clothing. Finally, we discuss future research directions, which include increasing efficiency, safety, and availability of personal protective clothing worldwide without conferring environmental problems.


Asunto(s)
Transmisión de Enfermedad Infecciosa/prevención & control , Personal de Salud , Equipo de Protección Personal/normas , Humanos , Equipo de Protección Personal/clasificación , Equipo de Protección Personal/virología , Guías de Práctica Clínica como Asunto , Textiles/normas
15.
Anesthesiology ; 111(2): 287-92, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19568159

RESUMEN

BACKGROUND: In a patient whose airway is likely to become obstructed upon loss of consciousness, anesthesia may be induced using an inhaled vapor. If the airway occludes during such an inhalational induction, the speed of patient awakening is related to the rate at which anesthetic gas redistributes away from lung and brain to other body compartments. To determine whether redistribution occurs more rapidly with a more blood-soluble or a less blood-soluble agent, the authors used subanesthetic concentrations of halothane and sevoflurane to simulate inhalational induction and airway obstruction in eight healthy human volunteers. METHODS: Inhalational induction was simulated using stepwise increases in inspired halothane or sevoflurane concentration, sufficient to reach an end-tidal concentration of approximately 0.1 minimal alveolar concentration. Airway occlusion was then simulated by initiating a 90-s period of rebreathing from a 1-l bag. During rebreathing, end-tidal halothane or sevoflurane concentration was measured continuously by mass spectrometry, and a time constant for the decline in concentration was calculated using a monoexponential model. RESULTS: At the onset of rebreathing, end-tidal concentrations of halothane and sevoflurane were 0.10 +/- 0.03 and 0.11 +/- 0.03 minimal alveolar concentration, respectively (mean +/- SD; P > 0.1, Student t test). During rebreathing, the time constants for the decline in end-tidal halothane and sevoflurane concentration were 22 +/- 9 and 62 +/- 16 s, respectively (P < 0.0001). CONCLUSIONS: During simulated airway occlusion in healthy volunteers, the end-tidal concentration of halothane falls more rapidly than that of sevoflurane. Halothane may therefore lead to more rapid awakening, compared with sevoflurane, should the airway obstruct during an inhalational induction of anesthesia.


Asunto(s)
Obstrucción de las Vías Aéreas/metabolismo , Anestesia por Inhalación , Anestésicos por Inhalación/farmacocinética , Halotano/farmacocinética , Éteres Metílicos/farmacocinética , Adulto , Anestésicos por Inhalación/administración & dosificación , Femenino , Halotano/administración & dosificación , Humanos , Masculino , Espectrometría de Masas , Éteres Metílicos/administración & dosificación , Alveolos Pulmonares/metabolismo , Mecánica Respiratoria/fisiología , Sevoflurano
16.
Anesth Analg ; 108(2): 631-4, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19151300

RESUMEN

BACKGROUND: Clonidine is an alpha(2) adrenoreceptor and imidazoline receptor agonist, which has analgesic, sedative, and minimum alveolar anesthetic concentration-sparing effects. It has been used orally, IV, and epidurally. In spinal surgery, there is a reluctance to use local anesthetic-based epidural analgesia postoperatively because of fears of masking important signs of nerve root or spinal cord injury. METHODS: We randomized 66 patients undergoing uncomplicated decompressive spinal surgery to receive an epidural infusion of either clonidine (Group C) or saline placebo (Group P) postoperatively. Morphine consumption by patient-controlled analgesia device was recorded for 36 h. RESULTS: Morphine consumption was significantly lower in Group C. The mean consumption at 36 h was 35 mg (95% confidence interval 21-50 mg) in Group C, compared with 61 mg (95% confidence interval 48-74 mg) in the control group. Nausea was significantly reduced in Group C (6.5%), when compared with placebo (38.2%). CONCLUSION: Low-dose epidural clonidine significantly reduced the demand for morphine and reduced postoperative nausea with few side effects.


Asunto(s)
Agonistas alfa-Adrenérgicos , Analgesia Epidural , Clonidina , Dolor Postoperatorio/tratamiento farmacológico , Columna Vertebral/cirugía , Agonistas alfa-Adrenérgicos/efectos adversos , Adulto , Anciano , Presión Sanguínea/efectos de los fármacos , Clonidina/efectos adversos , Método Doble Ciego , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Hipnóticos y Sedantes , Modelos Lineales , Masculino , Persona de Mediana Edad , Morfina/administración & dosificación , Morfina/uso terapéutico , Dimensión del Dolor/efectos de los fármacos , Proyectos Piloto , Náusea y Vómito Posoperatorios/epidemiología , Medicación Preanestésica , Retención Urinaria/inducido químicamente
17.
Intensive Care Med Exp ; 7(1): 59, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31676929

RESUMEN

BACKGROUND: Dynamic single-slice CT (dCT) is increasingly used to examine the intra-tidal, physiological variation in aeration and lung density in experimental lung injury. The ability of dCT to predict whole-lung values is unclear, especially for dual-energy CT (DECT) variables. Additionally, the effect of inspiration-related lung movement on CT variables has not yet been quantified. METHODS: Eight domestic pigs were studied under general anaesthesia, including four following saline-lavage surfactant depletion (lung injury model). DECT, dCT and whole-lung images were collected at 12 ventilatory settings. Whole-lung single energy scans images were collected during expiratory and inspiratory apnoeas at positive end-expiratory pressures from 0 to 20 cmH2O. Means and distributions of CT variables were calculated for both dCT and whole-lung images. The cranio-caudal displacement of the anatomical slice was measured from whole-lung images. RESULTS: Mean CT density and volume fractions of soft tissue, gas, iodinated blood, atelectasis, poor aeration, normal aeration and overdistension correlated between dCT and the whole lung (r2 0.75-0.94) with agreement between CT density distributions (r 0.89-0.97). Inspiration increased the matching between dCT and whole-lung values and was associated with a movement of 32% (SD 15%) of the imaged slice out of the scanner field-of-view. This effect introduced an artefactual increase in dCT mean CT density during inspiration, opposite to that caused by the underlying physiology. CONCLUSIONS: Overall, dCT closely approximates whole-lung aeration and density. This approximation is improved by inspiration where a decrease in CT density and atelectasis can be interpreted as physiological rather than artefactual.

18.
Respir Physiol Neurobiol ; 242: 12-18, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28323205

RESUMEN

Routine estimation of functional residual capacity (FRC) in ventilated patients has been a long held goal, with many methods previously proposed, but none have been used in routine clinical practice. This paper proposes three models for determining FRC using the nitrous oxide concentration from the entire expired breath in order to improve the precision of the estimate. Of the three models proposed, a dead space with two mixing compartments provided the best results, reducing the mean limits of agreement with the FRC measured by whole body plethysmography by up to 41%. This moves away from traditional lung models, which do not account for mixing within the dead space. Compared to literature values for FRC, the results are similar to those obtained using helium dilution and better than the LUFU device (Dräger Medical, Lubeck, Germany), with significantly better limits of agreement compared to plethysmography.


Asunto(s)
Capacidad Residual Funcional , Pulmón/fisiología , Modelos Biológicos , Espacio Muerto Respiratorio , Pruebas Respiratorias/instrumentación , Pruebas Respiratorias/métodos , Simulación por Computador , Femenino , Capacidad Residual Funcional/fisiología , Helio , Humanos , Análisis de los Mínimos Cuadrados , Pulmón/anatomía & histología , Masculino , Óxido Nitroso/análisis , Pletismografía Total , Análisis de Regresión , Respiración , Adulto Joven
19.
IEEE J Transl Eng Health Med ; 5: 2700209, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29282434

RESUMEN

The inspired sinewave technique is a noninvasive method to measure airway dead space, functional residual capacity, pulmonary blood flow, and lung inhomogeneity simultaneously. The purpose of this paper was to assess the repeatability and accuracy of the current device prototype in measuring functional residual capacity, and also participant comfort when using such a device. To assess within-session repeatability, six sinewave measurements were taken over two-hour period in 17 healthy volunteers. To assess day-to-day repeatability, measurements were taken over 16 days in 3 volunteers. To assess accuracy, sinewave measurements were compared to body plethysmography in 44 healthy volunteers. Finally, 18 volunteers who experienced the inspired sinewave device, body plethysmography and spirometry were asked to rate the comfort of each technique on a scale of 1-10. The repeatability coefficients for dead space, functional residual capacity, and blood flow were 48.7 ml, 0.48L, and 2.4L/min respectively. Bland-Altman analyses showed a mean BIAS(SD) of -0.68(0.42)L for functional residual capacity when compared with body plethysmography. 14 out of 18 volunteers rated the inspired sinewave device as their preferred technique. The repeatability and accuracy of functional residual capacity measurements were found to be as good as other techniques in the literature. The high level of comfort and the non-requirement of patient effort meant that, if further refined, the inspired sinewave technique could be an attractive solution for difficult patient groups such as very young children, elderly, and ventilated patients.

20.
Sci Rep ; 7(1): 7499, 2017 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-28878215

RESUMEN

Arterial oxygen partial pressure can increase during inspiration and decrease during expiration in the presence of a variable shunt fraction, such as with cyclical atelectasis, but it is generally presumed to remain constant within a respiratory cycle in the healthy lung. We measured arterial oxygen partial pressure continuously with a fast intra-vascular sensor in the carotid artery of anaesthetized, mechanically ventilated pigs, without lung injury. Here we demonstrate that arterial oxygen partial pressure shows respiratory oscillations in the uninjured pig lung, in the absence of cyclical atelectasis (as determined with dynamic computed tomography), with oscillation amplitudes that exceeded 50 mmHg, depending on the conditions of mechanical ventilation. These arterial oxygen partial pressure respiratory oscillations can be modelled from a single alveolar compartment and a constant oxygen uptake, without the requirement for an increased shunt fraction during expiration. Our results are likely to contribute to the interpretation of arterial oxygen respiratory oscillations observed during mechanical ventilation in the acute respiratory distress syndrome.


Asunto(s)
Arterias Carótidas/metabolismo , Pulmón/fisiología , Oxígeno/análisis , Animales , Presión Arterial , Pulmón/irrigación sanguínea , Respiración Artificial , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA