Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Más filtros

País/Región como asunto
País de afiliación
Intervalo de año de publicación
1.
BMC Bioinformatics ; 21(Suppl 2): 91, 2020 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-32164532

RESUMEN

BACKGROUND: Screening programs use mammography as primary diagnostic tool for detecting breast cancer at an early stage. The diagnosis of some lesions, such as microcalcifications, is still difficult today for radiologists. In this paper, we proposed an automatic binary model for discriminating tissue in digital mammograms, as support tool for the radiologists. In particular, we compared the contribution of different methods on the feature selection process in terms of the learning performances and selected features. RESULTS: For each ROI, we extracted textural features on Haar wavelet decompositions and also interest points and corners detected by using Speeded Up Robust Feature (SURF) and Minimum Eigenvalue Algorithm (MinEigenAlg). Then a Random Forest binary classifier is trained on a subset of a sub-set features selected by two different kinds of feature selection techniques, such as filter and embedded methods. We tested the proposed model on 260 ROIs extracted from digital mammograms of the BCDR public database. The best prediction performance for the normal/abnormal and benign/malignant problems reaches a median AUC value of 98.16% and 92.08%, and an accuracy of 97.31% and 88.46%, respectively. The experimental result was comparable with related work performance. CONCLUSIONS: The best performing result obtained with embedded method is more parsimonious than the filter one. The SURF and MinEigen algorithms provide a strong informative content useful for the characterization of microcalcification clusters.


Asunto(s)
Mama , Calcinosis/diagnóstico , Aprendizaje Automático , Algoritmos , Área Bajo la Curva , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico , Bases de Datos Factuales , Femenino , Humanos , Mamografía , Curva ROC
2.
AJR Am J Roentgenol ; 214(3): 707-714, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31939699

RESUMEN

OBJECTIVE. The objective of this study was to demonstrate the feasibility of dual-energy CT (DECT) for locoregional staging of breast cancer and differentiation of tumor histotypes. MATERIALS AND METHODS. From January 2016 to July 2017, a total of 31 patients (mean [± SD] age, 55.8 ± 14.8 years) with breast cancer diagnosed by needle biopsy who underwent preoperative contrast-enhanced DECT for staging purposes were selected from a retrospective review of institutional databases. Monochromatic images obtained at 40 and 70 keV were evaluated by two readers who determining the number of hypervascularized tumors present and the largest tumor diameter for each breast. The attenuation values and iodine concentration of tumors and normal breast tissue and the ratios of these findings in each tissue type were recorded. Cancers were classified as ductal carcinoma in situ, invasive ductal carcinoma, and invasive lobular carcinoma. The reference standard was the final pathologic finding after surgery. RESULTS. A total of 64 tumor lesions were found at histopathologic analysis versus 67 on DECT for 34 breasts (three bilateral cancers were included). Nonparametric statistics were used. The largest lesion diameter observed DECT was 33.2 ± 20.5 mm versus 31.8 ± 20.5 mm on pathologic analysis, and cancer distribution was correctly classified for 31 of 34 (91%) cases. ROC curves derived from lesion iodine concentration showed that the optimal thresholds for distinguishing infiltrating carcinomas (invasive lobular and ductal carcinomas) and from other lesions were 1.70 mg/mL (sensitivity, 94.9%; specificity, 93.0%; AUC value, 0.968). ROC curves derived from the ratio of the iodine concentration in lesions to that in normal breast parenchyma showed that 6.13 was the optimal threshold to distinguish invasive ductal carcinoma from other lesions (sensitivity, 87.0%; specificity, 81.1%; AUC value, 0.914). CONCLUSION. DECT is feasible and seems to be a reliable tool for locoregional staging of breast cancer.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja , Medios de Contraste , Estudios de Factibilidad , Femenino , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Retrospectivos
3.
Eur Radiol ; 29(4): 1799-1808, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30324386

RESUMEN

OBJECTIVE: The aim of this study is to present a 6-year prospective evaluation of second-look ultrasound (US) using volume navigation (V Nav) for MRI-detected additional breast lesions. METHODS: After IRB approvals in both institutions, 1930 consecutive prone MRI breast examinations in 1437 patients were prospectively evaluated. All patients with an MRI-detected additional lesion underwent second-look US, and if occult, contrast-enhanced MRI in supine position was performed for US and MRI co-registration. For patients with breast hypertrophy, MRI-guided biopsy was performed directly. Pathologic examination was the standard of reference. One-way ANOVA and chi-square tests were used. RESULTS: In 490 MRI examinations (25.4%, 490/1930), at least one additional breast lesion was detected for a total of 722 only MRI-detected lesions. Second-look US identified 549 additional lesions (23 ± 8 mm); 362 (65.9%, 362/549) proved benign at pathology and 187 (34.1%, 187/549) malignant. Second-look US with V Nav identified 151 additional lesions (17 ± 9 mm, p = n.s.); 67 (44.4%, 67/151) proved benign at pathology and 84 (55.6%, 84/151) malignant. MRI-guided biopsy was performed on 22 additional breast lesions (22 ± 8 mm, p = n.s.); pathology revealed 20 (90.9%, 20/22) benign lesions and 2 (9.1%, 2/22) malignant ones. Mass lesions were significantly higher in the second-look US group (p < 0.001). No significant difference in lesion dimension was found between the three groups (p = 0.729). CONCLUSIONS: Second-look US with V Nav can be effective in detecting a large number of additional breast lesions occult at second-look US and to biopsy a significant number of malignant lesions safely and irrespective of distance from skin or lesion position. KEY POINTS: • Second-look US with volume navigation is effective in detecting occult additional lesions. • Permits safe biopsies irrespective of position and depth • Reduces the need for MRI-guided biopsy.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Medios de Contraste , Femenino , Estudios de Seguimiento , Humanos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Imagen Multimodal/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
4.
Radiol Med ; 122(12): 918-927, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28770484

RESUMEN

PURPOSE: This article illustrates the feasibility of MR lymphangiography (MRL) for imaging lymphatic vessels in patients with lymphedema, its accuracy in distinguishing lymphatic vessels from veins, and its utility for planning Lymphaticovenous anastomosis (LVA) treatment. MATERIALS AND METHODS: We prospectively enrolled 30 patients (24 women, range 18-70, 17 cases of lower limb lymphedema, 6 cases of primary lymphedema). All the patients underwent MRL, using a 1.5T MR unit (Signa Twin Speed Hdxt; GE), after the subcutaneous injection of gadobenate dimeglumine (Gd-BOPTA) with a little dose of lidocaine into the interdigital webs of the dorsal foot or hand. Lymphatic vessels identified for the LVA at MRL were histologically confirmed after surgery. Enhancement of lymphatic vessels and veins at different times after injection of contrast medium and their diameters were measured. RESULTS: A total of 79 lymphatic vessels were clearly identified in 29 patients at MRL; their morphology was tortuous in 22 patients and rectilinear in 7, whereas, the adjacent veins were straight with focal bulging only at the level of venous valve; the enhancement kinetic of the two different structures were different (p < 0.05) but the mean diameter of affected lymphatic vessels was similar to the adjacent veins (p > 0.05). Thirty-four out of 38 specimens of presumed lymphatic vessels at MRL, collected during surgery, resulted positive at the immunoistochemical marker d2-40, with a significant association (Chi-square = 40.421, DF = 1, p < 0.05, contingency coefficent 0.644). One patient had an early complication 1 month after treatment. CONCLUSIONS: MRL is easy and safe to use and combines extensive information on the anatomy and functionality of lymphatic vessels and veins in a single process; therefore, it could be useful in LVA treatment planning and evaluating possible super-microsurgical treatment complications in patients with lymphedema.


Asunto(s)
Vasos Linfáticos/diagnóstico por imagen , Vasos Linfáticos/cirugía , Linfedema/diagnóstico por imagen , Linfedema/cirugía , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anastomosis Quirúrgica , Medios de Contraste , Estudios de Factibilidad , Humanos , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos , Estudios Prospectivos
6.
Plast Reconstr Surg ; 151(3): 384e-387e, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36730498

RESUMEN

SUMMARY: Skin-sparing mastectomy (SSM) is a surgical technique that preserves as much of the breast skin as possible. Double asymmetric circular incision (DACI) is a novel immediate breast reconstruction technique for immediate prepectoral implant placement using a titanium-coated polypropylene mesh. The aim of this technique is to optimize the cosmetic benefits of smaller incisions, preserve breast anatomy, avoid breast deformities, and reduce the negative psychological impact on the patient without increasing local recurrence risk. DACI SSM uses a double circular incision: the external drawing contains the nipple-areola complex, while the inner circular skin island is used to provide the skin for the new areola. The authors performed DACI SSM in patients with tumors located within 2 cm of the nipple-areola complex, or in patients with multicentric lesions involving areolar tissue. Forty-six patients underwent DACI SSM at the authors' institutions between February of 2014 and July of 2019. Two patients developed hematoma, and one patient developed seroma. No implant loss was observed. Skin flap necrosis rate was 0%. The BREAST-Q patient-reported outcomes measure was routinely used at the authors' institutions and recorded good aesthetic outcomes and high patient satisfaction. This new technique appears to be safe and easily reproducible in patients with small to medium-sized breasts and with little to moderate ptosis (up to Regnault classification grade II). CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Asunto(s)
Neoplasias de la Mama , Mamoplastia , Mastectomía Subcutánea , Herida Quirúrgica , Humanos , Femenino , Mastectomía/métodos , Neoplasias de la Mama/cirugía , Estudios Retrospectivos , Mamoplastia/métodos , Pezones/cirugía , Herida Quirúrgica/cirugía , Mastectomía Subcutánea/métodos
7.
Aesthet Surg J Open Forum ; 3(3): ojab016, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34131642

RESUMEN

BACKGROUND: Breast augmentation-mastopexy can yield an aesthetically attractive breast, but the 1-stage procedure is prone to unsatisfactory outcomes, including poor wound healing. OBJECTIVES: The authors evaluated whether postsurgical application of a polyurethane bra cup coated with oxygen-enriched olive oil (NovoX Cup; Moss SpA, Lesa, Novara, Italy) would decrease pain associated with augmentation-mastopexy and improve the quality of the surgical scar. METHODS: This retrospective study was conducted at a single center from January 2016 to June 2019. All patients underwent 1-stage augmentation-mastopexy with the inverted T incision. For 2 weeks postsurgically, wounds were dressed either with the oxygen-enriched olive oil bra or with Fitostimoline (Farmaceutici Damor SpA, Naples, Italy). Patients indicated their pain intensity on postoperative days 2, 3, and 10, and patients and independent observers scored scar quality on the Patient and Observer Scar Assessment Scale (POSAS) 6 and 12 months after the procedure. RESULTS: A total of 240 women (120 per study arm) completed the study. All the patients had satisfactory aesthetic results, and there were no tolerability concerns with either postoperative dressing. Compared with patients in the Fitostimoline group, patients who received the oxygen-enriched olive oil bra cup had significantly lower pain levels, and their surgical scars were given better scores on the POSAS. CONCLUSIONS: The results suggest that maintenance of the surgical wound in a film of oxygen-enriched olive oil for 2 weeks is a safe, effective modality for suppressing pain and promoting healing following augmentation-mastopexy.

8.
Plast Reconstr Surg ; 147(6): 1278-1286, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33973934

RESUMEN

BACKGROUND: Implant-based reconstruction is the most performed breast reconstruction, and both subpectoral and prepectoral approaches can lead to excellent results. Choosing the best procedure requires a thorough understanding of every single technique, and proper patient selection is critical to achieve surgical success, in particular when dealing with prepectoral breast reconstruction. METHODS: Between January of 2014 and December of 2018, patients undergoing mastectomy and eligible for immediate prepectoral breast reconstruction with tissue expander or definitive implant, were selected. The Prepectoral Breast Reconstruction Assessment score was applied to evaluate patient-related preoperative and intraoperative risk factors that could influence the success of prepectoral breast reconstruction. All patients were scored retrospectively, and the results obtained through this assessment tool were compared to the records of the surgical procedures actually performed. RESULTS: Three hundred fifty-two patients were included; 112 of them underwent direct-to-implant immediate reconstruction, and 240 underwent the two-stage procedure with temporary tissue expander. According to the Prepectoral Breast Reconstruction Assessment score, direct-to-implant reconstruction should have been performed 6.2 percent times less, leading to an increase of 1.4 percent in two-stage reconstruction and 4.8 percent in submuscular implant placement. CONCLUSIONS: To date, there is no validated system to guide surgeons in identifying the ideal patient for subcutaneous or retropectoral breast reconstruction and eventually whether she is a good candidate for direct-to-implant or two-stage reconstruction. The authors processed a simple risk-assessment score to objectively evaluate the patient's risk factors, to standardize the decision-making process, and to identify the safest and most reliable breast reconstructive procedure. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Asunto(s)
Implantación de Mama/métodos , Toma de Decisiones Clínicas , Mamoplastia/métodos , Selección de Paciente , Músculos Pectorales/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Mastectomía/métodos , Persona de Mediana Edad , Estudios Retrospectivos , Encuestas y Cuestionarios , Expansión de Tejido/métodos
9.
Clin Breast Cancer ; 20(3): e290-e294, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32144083

RESUMEN

BACKGROUND: The main goal of oncoplastic breast-conserving surgery (OBCS) is to obtain tumor-free resection margins after cancer excision with satisfactory cosmetic results. Positive tumor margins are associated with high rates of tumor recurrence requiring reoperation. The aim of this prospective clinical trial was to demonstrate the reliability of intraoperative ultrasound (IOUS) to obtain tumor-free resection margins in OBCS. PATIENTS AND METHODS: Between December 2016 and March 2018, data from 130 patients with by T1-2 breast cancer, either invasive or in situ, who underwent OBCS were prospectively collected. The oncoplastic surgeon performed IOUS in the operating theater to localize the lesion and mark its skin projection. Then specimens were examined to assess the presence of the lesion and margin adequacy. Definitive histologic reports were reviewed, with a focus on margin status. RESULTS: All patients experienced oncoplastic approaches, and lesions were always found on the specimen at the histologic report. In 126 cases (97%), margins were considered adequate. In 17 cases (13%), IOUS showed positive margins, and resection was contextually enlarged. In 12 of these (9%), the pathologic report confirmed the need for enlarged resection. This study shows that IOUS-guided surgery can obtain a high percentage of tumor-free resection margins in OBCS without scheduling conflicts between radiology, nuclear, and surgery departments. Full cooperation between radiologists and oncoplastic surgeons is required to achieve high-standard oncologic and reconstructive outcomes. CONCLUSION: IOUS represent an additional tool for the breast surgeon to improve margin-free management of neoplastic lesions, preventing reoperations in patients undergoing oncoplastic surgery.


Asunto(s)
Neoplasias de la Mama/cirugía , Cuidados Intraoperatorios/métodos , Mamoplastia/métodos , Mastectomía Segmentaria/métodos , Recurrencia Local de Neoplasia/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Mama/diagnóstico por imagen , Mama/patología , Mama/cirugía , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Estética , Estudios de Factibilidad , Femenino , Humanos , Márgenes de Escisión , Persona de Mediana Edad , Recurrencia Local de Neoplasia/prevención & control , Satisfacción del Paciente , Estudios Prospectivos , Reoperación/estadística & datos numéricos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Ultrasonografía Mamaria
10.
Cancers (Basel) ; 12(9)2020 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-32825583

RESUMEN

BACKGROUND: To assess the feasibility, image quality and diagnostic value of contrast-enhanced breast magnetic resonance imaging (MRI) performed in a supine compared to a prone position. METHODS: One hundred and fifty-one patients who had undergone a breast MRI in both the standard prone and supine position were evaluated retrospectively. Two 1.5 T MR scanners were used with the same image resolution, sequences and contrast medium in all examinations. The image quality and the number and dimensions of lesions were assessed by two expert radiologists in an independent and randomized fashion. Two different classification systems were used. Histopathology was the standard of reference. RESULTS: Two hundred and forty MRIs from 120 patients were compared. The analysis revealed 134 MRIs with monofocal (U), 68 with multifocal (M) and 38 with multicentric (C) lesions. There was no difference between the image quality and number of lesions in the prone and supine examinations. A significant difference in the lesion extension was observed between the prone and supine position. No significant differences emerged in the classification of the lesions detected in the prone compared to the supine position. CONCLUSIONS: It is possible to perform breast MRI in a supine position with the same image quality, resolution and diagnostic value as in a prone position. In the prone position, the lesion dimensions are overestimated with a higher wash-in peak than in the supine position.

11.
Medicine (Baltimore) ; 99(30): e21095, 2020 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-32791685

RESUMEN

RATIONALE: Anaplastic large T-cell lymphoma (BI-ALCL) is a rare primitive lymphoma described in women with breast implant prostheses, which has been arousing interest in recent years due to its potentially high social impact. The difficult diagnosis associated with the high and increasing number of prosthetic implants worldwide has led to hypothesize an underestimation of the real impact of the disease among prosthesis-bearing women. The aim of this work is to search for specific radiological signs of disease linked to the chronic inflammatory pathogenetic mechanism. PATIENT CONCERNS: This work describes a case of BI-ALCL in an American woman with no personal or family history of cancer, who underwent breast augmentation for esthetic purposes at our Institute. After about 10 years of relative well-being, the patient returned to our Institute with clear evidence of breast asymmetry due to the increase in volume of the right breast which had progressively become larger over a period of 6 months. There was no evidence of palpable axillary lymph nodes or other noteworthy signs. DIAGNOSIS: The ultrasound and magnetic resonance (MR) tests indicated the presence of seroma with amorphous material in the exudate which was confirmed by indirect signs, visible in right breast mammography. Due to suspected cold seroma, an ultrasound-guided needle aspiration was performed for the cytological analysis of the effusion which highlighted the presence of a number of large-sized atypical cells with an irregular nucleus with CD30 immunoreactivity, leucocyte common antigen (CD45) compatible with the BI-ALCL diagnosis. INTERVENTIONS: In our case, a capsulectomy was performed because the disease was limited inside the capsule and periprosthetic seroma. The final histological examination confirmed the stage. LESSONS: The patient is being monitored and shows no signs of recurrence of disease >24 months after surgery. CONCLUSION: A diagnosis of BI-ALCL can be reached using new radiological indicators, such as fibrin, which is clearly visible by MR in the form of nonvascularized debris of amorphous material hypointense in all sequences, free flowing or adhered to the external surface of the prosthesis.


Asunto(s)
Implantes de Mama/efectos adversos , Linfoma Anaplásico de Células Grandes/diagnóstico por imagen , Biopsia con Aguja , Diagnóstico Diferencial , Femenino , Humanos , Inmunohistoquímica , Linfoma Anaplásico de Células Grandes/etiología , Linfoma Anaplásico de Células Grandes/patología , Imagen por Resonancia Magnética , Mamografía , Persona de Mediana Edad , Seroma/diagnóstico por imagen , Ultrasonografía Mamaria
12.
Diagnostics (Basel) ; 10(5)2020 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-32397505

RESUMEN

The typification of breast lumps with fine-needle biopsies is often affected by inconclusive results that extend diagnostic time. Many breast centers have progressively substituted cytology with micro-histology. The aim of this study is to assess the performance of a 13G-needle biopsy using cable-free vacuum-assisted breast biopsy (VABB) technology. Two of our operators carried out 200 micro-histological biopsies using the Elite 13G-needle VABB and 1314 14-16G-needle core biopsies (CBs) on BI-RADS 3, 4, and 5 lesions. Thirty-one of the procedures were repeated following CB, eighteen following cytological biopsy, and three after undergoing both procedures. The VABB Elite procedure showed high diagnostic performance with an accuracy of 94.00%, a sensitivity of 92.30%, and a specificity of 100%, while the diagnostic underestimation was 11.00%, all significantly comparable to of the CB procedure. The VABB Elite 13G system has been shown to be a simple, rapid, reliable, and well-tolerated biopsy procedure, without any significant complications and with a diagnostic performance comparable to traditional CB procedures. The histological class change in an extremely high number of samples would suggest the use of this procedure as a second-line biopsy for suspect cases or those with indeterminate cyto-histological results.

13.
AJR Am J Roentgenol ; 192(6): 1608-17, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19457825

RESUMEN

OBJECTIVE: The purpose of our study was to use the total choline-containing compound (tCho) peak integral as a marker of malignancy in breast MR spectroscopy (MRS). SUBJECTS AND METHODS: Forty-eight single-voxel water- and fat-suppressed 1.5-T MRS measurements were performed in 42 patients, obtaining both absolute tCho peak integral and tCho peak integral normalized for the volume of interest (VOI). Our reference standard was histology for lesions with BI-RADS category 4 and 5 and histology or at least a 2-year follow-up for findings with BI-RADS 2 and 3 and normal glands. Receiver operating characteristic (ROC) analysis, Mann-Whitney U test, and Spearman's rank correlation were used. RESULTS: Three of 48 measurements (6%) failed. Of the remaining 45 spectra, 18 nonmalignant tissues showed no tCho peak, eight nonmalignant tissues showed a tCho peak integral from 0.99 to 9.03 arbitrary units (AU), and 19 malignant lesions showed a tCho peak integral from 1.26 to 19.80 AU. The diameter of nonmalignant tissues was 16.9 +/- 7.4 mm; that of malignant lesions was 15.3 +/- 6.9 mm (p = 0.308). At ROC analysis, the optimal threshold was 1.90 AU for absolute tCho peak, with 0.895 (17/19) sensitivity, 0.923 (24/26) specificity, and an AUC (area under the curve) of 0.917 (95% CI, 0.822-1.000); the optimal threshold was 0.85 AU/mL for the normalized tCho peak integral with 0.842 (16/19) sensitivity, 0.885 (23/26) specificity, and an AUC of 0.941 (0.879-1.000) (p = 0.470). A negative correlation (p = 0.011) was found between the VOI and the normalized tCho peak integral of malignant tissues. CONCLUSION: Breast MRS using tCho peak integral reaches a high level of diagnostic performance.


Asunto(s)
Biomarcadores de Tumor/análisis , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/metabolismo , Colina/análisis , Espectroscopía de Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Persona de Mediana Edad , Protones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Gland Surg ; 8(Suppl 3): S188-S207, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31559186

RESUMEN

Anterior mediastinal masses include a wide spectrum of malignant and benign pathologies with a large percentage represented by thymic lesions. Distinguishing these masses on diagnostic imaging is fundamental to guide the proper management for each patient. This review illustrates possibilities and limits of different imaging modalities to diagnose a lesion of the anterior mediastinum with particular attention to thymic disease.

15.
Semin Ultrasound CT MR ; 40(1): 36-50, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30686366

RESUMEN

Underreporting of occupational lung diseases is a widespread problem in clinical practice. In Europe there is not a common regulation even for the recognition of occupational cancers. Furthermore epidemiologic data on occupational interstitial lung diseases, in general, is limited by no standardized diagnostic criteria, varied physician awareness and training, limitations inherent to the various data sources, and the long latency period. Therefore, to optimize the management of the patient with occupational pathology, the collaboration and skills of the multidisciplinary at the service of the patient, play a fundamental role. In particular, radiologists should give substance to a clinical suspicion on an anamnestic basis and at the same time should recognize patterns of illness that can lead to the emergence of stories of misunderstood exposures. This article aims to provide an overview of the main occupational lung diseases with attention to diagnostic possibilities of the different imaging techniques. The issue of the radiological error is investigated, providing tools to minimize it in the daily practice.


Asunto(s)
Errores Diagnósticos/prevención & control , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Profesionales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Humanos , Pulmón/diagnóstico por imagen , Radiografía
16.
J BUON ; 24(5): 1889-1897, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31786852

RESUMEN

PURPOSE: The onset characteristics of the anaplastic large cell lymphoma (BI-ALCL) are non-specific and the diagnosis is often difficult and based on clinical suspicion and cytological sampling. The presence of non-pathognomonic radiological signs may delay the diagnosis of BI-ALCL, influencing patient prognosis. This could have an important social impact, considering that the incidence of BI-ALCL correlates with the number of prosthetic implants, which is in constant increase worldwide. The aim of this study was to verify if fibrin can represent a potential early radiological sign of the disease. METHODS: In this study, we present two cases of our series and review the previous studies already described in literature, searching for any early radiological sign of the disease and reporting a diagnostic work-up process for an early diagnosis. RESULTS: Signs clearly recognizable only of magnetic resonance were the following: thickening and hyperemia of the fibrous capsule with seroma and amorphous material (fibrin) present in 8 out of 10 cases (80%) detected on magnetic resonance images (certain or doubtful). CONCLUSION: The presence of fibrin in the periprosthetic effusion, well detectable by magnetic resonance imaging, could represent an early pathognomonic sign of the disease.


Asunto(s)
Biomarcadores de Tumor/análisis , Implantación de Mama/efectos adversos , Implantación de Mama/instrumentación , Implantes de Mama/efectos adversos , Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Fibrina/análisis , Linfoma Anaplásico de Células Grandes/diagnóstico por imagen , Imagen por Resonancia Magnética , Adulto , Neoplasias de la Mama/química , Neoplasias de la Mama/cirugía , Femenino , Humanos , Linfoma Anaplásico de Células Grandes/química , Linfoma Anaplásico de Células Grandes/cirugía , Persona de Mediana Edad , Valor Predictivo de las Pruebas
17.
J Clin Med ; 8(6)2019 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-31234363

RESUMEN

Contrast-Enhanced Spectral Mammography (CESM) is a novelty instrumentation for diagnosing of breast cancer, but it can still be considered operator dependent. In this paper, we proposed a fully automatic system as a diagnostic support tool for the clinicians. For each Region Of Interest (ROI), a features set was extracted from low-energy and recombined images by using different techniques. A Random Forest classifier was trained on a selected subset of significant features by a sequential feature selection algorithm. The proposed Computer-Automated Diagnosis system is tested on 48 ROIs extracted from 53 patients referred to Istituto Tumori "Giovanni Paolo II" of Bari (Italy) from the breast cancer screening phase between March 2017 and June 2018. The present method resulted highly performing in the prediction of benign/malignant ROIs with median values of sensitivity and specificity of 87 . 5 % and 91 . 7 % , respectively. The performance was high compared to the state-of-the-art, even with a moderate/marked level of parenchymal background. Our classification model outperformed the human reader, by increasing the specificity over 8 % . Therefore, our system could represent a valid support tool for radiologists for interpreting CESM images, both reducing the false positive rate and limiting biopsies and surgeries.

18.
Invest Radiol ; 43(4): 236-42, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18340247

RESUMEN

RATIONALE AND OBJECTIVE: Gadobenate dimeglumine (Gd-BOPTA), a high-relaxivity contrast agent, has been recently proposed for dynamic MR imaging of the breast. The objective of this study was to optimize the diagnostic performance of Gd-BOPTA-enhanced dynamic breast MR imaging by using adjusted initial enhancement thresholds. METHODS: Thirty-four patients with 36 breast lesions (malignant/benign = 28/8) underwent dynamic breast MRI with 0.1 mmol/kg Gd-BOPTA and 120-second time resolution. A score system based on shape (round/oval/lobular = 0; linear/dendritic/stellate = 1), margins (defined = 0; undefined = 1), pattern (homogeneous = 0; inhomogeneous = 1; rim = 2), kinetics (continuous = 0; plateau = 1; washout = 2), and initial enhancement was used. Initial enhancement was determined with standard (<50% = 0; 50%-100% = 1; >100% = 2) and adjusted (<100% = 0; 100%-240% = 1; >240% = 2) thresholds. Scores of 0 to 3 indicated benign lesions and scores of 4 to 8 malignant lesions. Diagnostic performance was assessed in terms of sensitivity, specificity, positive and negative predictive values, and overall accuracy. RESULTS: The initial enhancement was >100% for 26 malignant and 7 benign lesions and >240% for 16 and 1 lesions, respectively. The overall score was 5.89 +/- 1.34 with standard thresholds and 5.50 +/- 1.53 with adjusted thresholds (P = 0.003) for cancers, 4.00 +/- 1.93 and 3.25 +/- 1.75 (P = 0.028) for benign lesions, respectively. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 96%, 13%, 79%, 50%, and 78%, respectively, with standard thresholds and 96%, 75%, 93%, 86%, and 92%, respectively, with adjusted thresholds. A ductal carcinoma in situ was false negative whereas a fat necrosis and a papilloma were false positive with both thresholds. Three fibroadenomas, 1 adenosis, and 1 fibrosis were false positive with standard thresholds but true negatives with adjusted thresholds. CONCLUSIONS: Lesion characterization with Gd-BOPTA requires higher thresholds for initial enhancement than those used with conventional Gd-chelates, leading to improved specificity, predictive values, and accuracy.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética/métodos , Meglumina/análogos & derivados , Compuestos Organometálicos , Adulto , Anciano , Ensayos Clínicos Fase II como Asunto , Medios de Contraste , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad , Estadísticas no Paramétricas
19.
J Plast Reconstr Aesthet Surg ; 71(9): 1282-1285, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29983366

RESUMEN

INTRODUCTION: To verify the diagnostic value of contrast-enhanced breast and axillary MRI in patients with tissue expander labeled as "MR-unsafe" and to confirm its safety. PATIENTS AND METHODS: Breast MRI examinations performed in patients with tissue expander in the period from August 2010 to December 2017 were reviewed after IRB approval. In the case of breast lesion or lymph node, breast MRI exams after definitive prosthetic replacement were used for comparison. Breast MRI was performed using 1.5 T equipment with a dedicated coil. The protocol included axial STIR sequence and axial dynamic sequence with fat suppression (1 pre-contrast and 4 post-contrast phases). Two radiologists experienced in breast imaging reviewed images using six parameters for image quality evaluation. t-Test for dependent samples, Wilcoxon and Sign test were used. RESULTS: Twenty-three patients (49 ±â€¯9 years, range 34-68 years) with tissue expander who underwent contrast-enhanced MRI were reviewed. Thirteen breast lesions (12.92 ±â€¯4.84 mm) and eleven lymph nodes (11.00 ±â€¯4.29 mm) were found. In breast MRI examinations used for comparison no significant difference was observed in breast lesions (12.69 ±â€¯4.71 mm, P = 0.707) or lymph node dimensions (10.58 ±â€¯3.00 mm, P = 0.538). No significant difference was observed in lesion classification. A significantly lower visibility was observed for vascular maps (P < 0.001). None of the patients reported sensations of heating or skin burns. None of the patients revealed any clinical effects or signs of pathology after MRI examination. CONCLUSION: When necessary, after adequate information and preparation, contrast-enhanced breast MRI can be performed in patients with tissue expanders maintaining its diagnostic value and safety.


Asunto(s)
Axila/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Dispositivos de Expansión Tisular , Adulto , Anciano , Mama/cirugía , Neoplasias de la Mama/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
20.
Biomed Res Int ; 2018: 3896946, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30420960

RESUMEN

Contrast enhanced magnetic resonance imaging (CE-MRI) has acquired a central role in the field of diagnosis and evaluation of breast cancer due to its high sensitivity; on the other hand, MRI has shown a variable specificity because of the wide overlap between the imaging features of benign and malignant lesions. Therefore, when an additional breast lesion is identified at CE-MRI, a second look with targeted US is generally performed because it provides additional information to further characterise the target lesion and makes it possible to perform US-guided biopsies which are costless and more comfortable for patients compared with MRI-guided ones. Nevertheless, there is not always a correspondence between CE-MR findings and targeted US due to several factors including different operator's experience and position of patients. A new technique has recently been developed in order to overcome these limitations: US with MR coregistration, which can synchronise a sonography image and the MR image with multiplanar reconstruction (MPR) of the same section in real time. The aim of our study is to review the literature concerning the second look performed with this emerging and promising technique, showing both advantages and limitations in comparison with conventional targeted US.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Imagen por Resonancia Magnética , Ultrasonografía Mamaria , Femenino , Humanos , Persona de Mediana Edad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA