RESUMEN
BACKGROUND: When using biological variation (BV) data, BV estimates need to be robust and representative. High-endurance athletes represent a population under special physiological conditions, which could influence BV estimates. Our study aimed to estimate BV in athletes for metabolism and growth-related biomarkers involved in the Athlete Biological Passport (ABP), by 2 different statistical models. METHODS: Thirty triathletes were sampled monthly for 11 months. The samples were analyzed for human growth hormone (hGH), insulin-like growth factor-1 (IGF-1), insulin-like growth factor binding protein 3 (IGFBP-3), insulin, and N-terminal propeptide of type III procollagen (P-III-NP) by immunoassay. Bayesian and ANOVA methods were applied to estimate within-subject (CVI) and between-subject BV. RESULTS: CVI estimates ranged from 7.8% for IGFBP-3 to 27.0% for insulin, when derived by the Bayesian method. The 2 models gave similar results, except for P-III-NP. Data were heterogeneously distributed for P-III-NP for the overall population and in females for IGF-1 and IGFBP-3. BV components were not estimated for hGH due to lack of steady state. The index of individuality was below 0.6 for all measurands, except for insulin. CONCLUSIONS: In an athlete population, to apply a common CVI for insulin would be appropriate, but for IGF-1 and IGFBP-3 gender-specific estimates should be applied. P-III-NP data were heterogeneously distributed and using a mean CVI may not be representative for the population. The high degree of individuality for IGF-1, IGFBP-3, and P-III-NP makes them good candidates to be interpreted through reference change values and the ABP.
Asunto(s)
Atletas , Biomarcadores , Hormona de Crecimiento Humana , Proteína 3 de Unión a Factor de Crecimiento Similar a la Insulina , Factor I del Crecimiento Similar a la Insulina , Insulina , Humanos , Factor I del Crecimiento Similar a la Insulina/análisis , Factor I del Crecimiento Similar a la Insulina/metabolismo , Biomarcadores/sangre , Masculino , Proteína 3 de Unión a Factor de Crecimiento Similar a la Insulina/sangre , Femenino , Adulto , Insulina/sangre , Hormona de Crecimiento Humana/sangre , Teorema de Bayes , Procolágeno/sangre , Fragmentos de Péptidos/sangreRESUMEN
BACKGROUND: Reference change values (RCV) are used to indicate a change in analyte concentration that is unlikely to be due to random variation in the patient or the measurement. Current theory describes RCV relative to a first measurement result (X1). We investigate an alternative view predicting the starting point for RCV calculations from X1 and its location in the reference interval. METHODS: Data for serum sodium, calcium, and total protein from the European Biological Variation study and from routine clinical collections were analyzed for the effect of the position of X1 within the reference interval on the following result from the same patient. A model to describe the effect was determined, and an equation to predict the RCV for a sample in a population was developed. RESULTS: For all data sets, the midpoints of the RCVs were dependent on the position of X1 in the population. Values for X1 below the population mean were more likely to be followed by a higher result, and X1 results above the mean were more likely to be followed by lower results. A model using population mean, reference interval dispersion, and result diagnostic variation provided a good fit with the data sets, and the derived equation predicted the changes seen. CONCLUSIONS: We have demonstrated that the position of X1 within the reference interval creates an asymmetrical RCV. This can be described as a regression to the population mean. Adding this concept to the theory of RCVs will be an important consideration in many cases.
Asunto(s)
Sodio , Humanos , Valores de Referencia , Sodio/sangre , Calcio/sangreRESUMEN
OBJECTIVES: To deliver biological variation (BV) data for serum hepcidin, soluble transferrin receptor (sTfR), erythropoietin (EPO) and interleukin 6 (IL-6) in a population of well-characterized high-endurance athletes, and to evaluate the potential influence of exercise and health-related factors on the BV. METHODS: Thirty triathletes (15 females) were sampled monthly (11 months). All samples were analyzed in duplicate and BV estimates were delivered by Bayesian and ANOVA methods. A linear mixed model was applied to study the effect of factors related to exercise, health, and sampling intervals on the BV estimates. RESULTS: Within-subject BV estimates (CVI) were for hepcidin 51.9â¯% (95â¯% credibility interval 46.9-58.1), sTfR 10.3â¯% (8.8-12) and EPO 27.3â¯% (24.8-30.3). The mean concentrations were significantly different between sex, but CVI estimates were similar and not influenced by exercise, health-related factors, or sampling intervals. The data were homogeneously distributed for EPO but not for hepcidin or sTfR. IL-6 results were mostly below the limit of detection. Factors related to exercise, health, and sampling intervals did not influence the BV estimates. CONCLUSIONS: This study provides, for the first time, BV data for EPO, derived from a cohort of well-characterized endurance athletes and indicates that EPO is a good candidate for athlete follow-up. The application of the Bayesian method to deliver BV data illustrates that for hepcidin and sTfR, BV data are heterogeneously distributed and using a mean BV estimate may not be appropriate when using BV data for laboratory and clinical applications.
Asunto(s)
Hepcidinas , Interleucina-6 , Femenino , Humanos , Teorema de Bayes , Receptores de Transferrina , Hierro , AtletasRESUMEN
OBJECTIVES: Personalized reference intervals (prRI) have been proposed as a diagnostic tool for assessing measurands with high individuality. Here, we evaluate clinical performance of prRI using carcinoembryonic antigen (CEA) for cancer detection and compare it with that of reference change values (RCV) and other criteria recommended by clinical guidelines (e.g. 25â¯% of change between consecutive CEA results (RV25) and the cut-off point of 5⯵g/L (CP5)). METHODS: Clinical and analytical data from 2,638 patients collected over 19 years were retrospectively evaluated. A total 15,485 CEA results were studied. For each patient, we calculated prRI and RCV using computer algorithms based on the combination of different strategies to assess the number of CEA results needed, consideration of one or two limits of reference interval and the intraindividual biological variation estimate (CVI) used: (a) publicly available (CVI-EU), (b) CVI calculated using an indirect method (CVI-NOO) and (c) within-person BV (CVP). For each new result identified falling outside the prRI, exceeding the RCV interval, RV25 or CP5, we searched for records identifying the presence of tumour at 3 and 12 months after the test. The sensitivity, specificity and predictive power of each strategy were calculated. RESULTS: PrRI approaches derived using CVI-EU, and both limits of reference interval achieve the best sensitivity (87.5â¯%) and NPV (99.3â¯%) at 3 and 12 months of all evaluated criteria. Only 3 results per patients are enough to calculate prRIs that reach this diagnostic performance. CONCLUSIONS: PrRI approaches could be an effective tool to rule out new oncological findings during the active surveillance of patients.
RESUMEN
Analytical performance specifications (APS) are typically established through one of three models: (i) outcome studies, (ii) biological variation (BV), or (iii) state-of-the-art. Presently, The APS can, for most measurands that have a stable concentration, be based on BV. BV based APS, defined for imprecision, bias, total allowable error and allowable measurement uncertainty, are applied to many different processes in the laboratory. When calculating APS, it is important to consider the different APS formulae, for what setting they are to be applied and if they are suitable for the intended purpose. In this opinion paper, we elucidate the background, limitations, strengths, and potential intended applications of the different BV based APS formulas. When using BV data to set APS, it is important to consider that all formulae are contingent on accurate and relevant BV estimates. During the last decade, efficient procedures have been established to obtain reliable BV estimates that are presented in the EFLM biological variation database. The database publishes detailed BV data for numerous measurands, global BV estimates derived from meta-analysis of quality-assured studies of similar study design and automatic calculation of BV based APS.
Asunto(s)
Variación Biológica Poblacional , HumanosRESUMEN
There is a need for standards for generation and reporting of Biological Variation (BV) reference data. The absence of standards affects the quality and transportability of BV data, compromising important clinical applications. To address this issue, international expert groups under the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) have developed an online resource (https://tinyurl.com/bvmindmap) in the form of an interactive mind map that serves as a guideline for researchers planning, performing and reporting BV studies. The mind map addresses study design, data analysis, and reporting criteria, providing embedded links to relevant references and resources. It also incorporates a checklist approach, identifying a Minimum Data Set (MDS) to enable the transportability of BV data and incorporates the Biological Variation Data Critical Appraisal Checklist (BIVAC) to assess study quality. The mind map is open to access and is disseminated through the EFLM BV Database website, promoting accessibility and compliance to a reporting standard, thereby providing a tool to be used to ensure data quality, consistency, and comparability of BV data. Thus, comparable to the STARD initiative for diagnostic accuracy studies, the mind map introduces a Standard for Reporting Biological Variation Data Studies (STARBIV), which can enhance the reporting quality of BV studies, foster user confidence, provide better decision support, and be used as a tool for critical appraisal. Ongoing refinement is expected to adapt to emerging methodologies, ensuring a positive trajectory toward improving the validity and applicability of BV data in clinical practice.
RESUMEN
OBJECTIVES: An insulin resistant state is characteristic of patients with type 2 diabetes, polycystic ovary syndrome, and metabolic syndrome. Identification of insulin resistance (IR) is most readily achievable using formulae combining plasma insulin and glucose results. In this study, we have used data from the European Biological Variation Study (EuBIVAS) to examine the biological variability (BV) of IR using the Homeostasis Model Assessment for Insulin Resistance (HOMA-IR) and the Quantitative Insulin sensitivity Check Index (QUICKI). METHODS: Ninety EuBIVAS non-diabetic subjects (52F, 38M) from five countries had fasting HOMA-IR and QUICKI calculated from plasma glucose and insulin samples collected concurrently on 10 weekly occasions. The within-subject (CVI) and between-subject (CVG) BV estimates with 95â¯% CIs were obtained by CV-ANOVA after analysis of trends, variance homogeneity and outlier removal. RESULTS: The CVI of HOMA-IR was 26.7â¯% (95â¯% CI 25.5-28.3), driven largely by variability in plasma insulin and the CVI for QUICKI was 4.1â¯% (95â¯% CI 3.9-4.3), reflecting this formula's logarithmic transformation of glucose and insulin values. No differences in values or BV components were observed between subgroups of men or women below and above 50 years. CONCLUSIONS: The EuBIVAS, by utilising a rigorous experimental protocol, has produced robust BV estimates for two of the most commonly used markers of insulin resistance in non-diabetic subjects. This has shown that HOMA-IR, in particular, is highly variable in the same individual which limits the value of single measurements.
RESUMEN
BACKGROUND: Hematological parameters have many applications in athletes, from monitoring health to uncovering blood doping. This study aimed to deliver biological variation (BV) estimates for 9 hematological parameters by a Biological Variation Data Critical Appraisal Checklist (BIVAC) design in a population of recreational endurance athletes and to assess the effect of self-reported exercise and health-related variables on BV. METHODS: Samples were drawn from 30 triathletes monthly for 11 months and measured in duplicate for hematological measurands on an Advia 2120 analyzer (Siemens Healthineers). After outlier and homogeneity analysis, within-subject (CVI) and between-subject (CVG) BV estimates were delivered (CV-ANOVA and log-ANOVA, respectively) and a linear mixed model was applied to analyze the effect of exercise and other related variables on the BV estimates. RESULTS: CVI estimates ranged from 1.3% (95%CI, 1.2-1.4) for mean corpuscular volume to 23.8% (95%CI, 21.6-26.3) for reticulocytes. Sex differences were observed for platelets and OFF-score. The CVI estimates were higher than those reported for the general population based on meta-analysis of eligible studies in the European Biological Variation Database, but 95%CI overlapped, except for reticulocytes, 23.9% (95%CI, 21.6-26.5) and 9.7% (95%CI, 6.4-11.0), respectively. Factors related to exercise and athletes' state of health did not appear to influence the BV estimates. CONCLUSIONS: This is the first BIVAC-compliant study delivering BV estimates that can be applied to athlete populations performing high-level aerobic exercise. CVI estimates of most parameters were similar to the general population and were not influenced by exercise or athletes' state of health.
Asunto(s)
Variación Biológica Poblacional , Lista de Verificación , Humanos , Masculino , FemeninoRESUMEN
Among medical specialties, laboratory medicine is the largest producer of structured data and must play a crucial role for the efficient and safe implementation of big data and artificial intelligence in healthcare. The area of personalized therapies and precision medicine has now arrived, with huge data sets not only used for experimental and research approaches, but also in the "real world". Analysis of real world data requires development of legal, procedural and technical infrastructure. The integration of all clinical data sets for any given patient is important and necessary in order to develop a patient-centered treatment approach. Data-driven research comes with its own challenges and solutions. The Findability, Accessibility, Interoperability, and Reusability (FAIR) Guiding Principles provide guidelines to make data findable, accessible, interoperable and reusable to the research community. Federated learning, standards and ontologies are useful to improve robustness of artificial intelligence algorithms working on big data and to increase trust in these algorithms. When dealing with big data, the univariate statistical approach changes to multivariate statistical methods significantly shifting the potential of big data. Combining multiple omics gives previously unsuspected information and provides understanding of scientific questions, an approach which is also called the systems biology approach. Big data and artificial intelligence also offer opportunities for laboratories and the In Vitro Diagnostic industry to optimize the productivity of the laboratory, the quality of laboratory results and ultimately patient outcomes, through tools such as predictive maintenance and "moving average" based on the aggregate of patient results.
Asunto(s)
Inteligencia Artificial , Macrodatos , Humanos , Algoritmos , Atención a la Salud , Medicina de Precisión/métodosRESUMEN
Biological variation (BV) data have many applications in laboratory medicine. However, these depend on the availability of relevant and robust BV data fit for purpose. BV data can be obtained through different study designs, both by experimental studies and studies utilizing previously analysed routine results derived from laboratory databases. The different BV applications include using BV data for setting analytical performance specifications, to calculate reference change values, to define the index of individuality and to establish personalized reference intervals. In this review, major achievements in the area of BV from last decade will be presented and discussed. These range from new models and approaches to derive BV data, the delivery of high-quality BV data by the highly powered European Biological Variation Study (EuBIVAS), the Biological Variation Data Critical Appraisal Checklist (BIVAC) and other standards for deriving and reporting BV data, the EFLM Biological Variation Database and new applications of BV data including personalized reference intervals and measurement uncertainty.
Asunto(s)
Lista de Verificación , Humanos , Valores de Referencia , Estándares de ReferenciaRESUMEN
OBJECTIVES: Retrospective studies frequently assume analytes long-term stability at ultra-low temperatures. However, these storage conditions, common among biobanks and research, may increase the preanalytical variability, adding a potential uncertainty to the measurements. This study is aimed to evaluate long-term storage stability of different analytes at <-70 °C and to assess its impact on the reference change value formula. METHODS: Twenty-one analytes commonly measured in clinical laboratories were quantified in 60 serum samples. Samples were immediately aliquoted and frozen at <-70 °C, and reanalyzed after 11 ± 3.9 years of storage. A change in concentration after storage was considered relevant if the percent deviation from the baseline measurement was significant and higher than the analytical performance specifications. RESULTS: Preanalytical variability (CVP) due to storage, determined by the percentage deviation, showed a noticeable dispersion. Changes were relevant for alanine aminotransferase, creatinine, glucose, magnesium, potassium, sodium, total bilirubin and urate. No significant differences were found in aspartate aminotransferase, calcium, carcinoembryonic antigen, cholesterol, C-reactive protein, direct bilirubin, free thryroxine, gamma-glutamyltransferase, lactate dehydrogenase, prostate-specific antigen, triglycerides, thyrotropin, and urea. As nonnegligible, CVP must remain included in reference change value formula, which was modified to consider whether one or two samples were frozen. CONCLUSIONS: After long-term storage at ultra-low temperatures, there was a significant variation in some analytes that should be considered. We propose that reference change value formula should include the CVP when analyzing samples stored in these conditions.
Asunto(s)
Bilirrubina , Recolección de Muestras de Sangre , Humanos , Masculino , Estudios Retrospectivos , Temperatura , Factores de TiempoRESUMEN
OBJECTIVES: Thyroid biomarkers are fundamental for the diagnosis of thyroid disorders and for the monitoring and treatment of patients with these diseases. The knowledge of biological variation (BV) is important to define analytical performance specifications (APS) and reference change values (RCV). The aim of this study was to deliver BV estimates for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3), thyroglobulin (TG), and calcitonin (CT). METHODS: Analyses were performed on serum samples obtained from the European Biological Variation Study population (91 healthy individuals from six European laboratories; 21-69 years) on the Roche Cobas e801 at the San Raffaele Hospital (Milan, Italy). All samples from each individual were evaluated in duplicate within a single run. The BV estimates with 95% CIs were obtained by CV-ANOVA, after analysis of variance homogeneity and outliers. RESULTS: The within-subject (CV I ) BV estimates were for TSH 17.7%, FT3 5.0%, FT4 4.8%, TG 10.3, and CT 13.0%, all significantly lower than those reported in the literature. No significant differences were observed for BV estimates between men and women. CONCLUSIONS: The availability of updated, in the case of CT not previously published, BV estimates for thyroid markers based on the large scale EuBIVAS study allows for refined APS and associated RCV applicable in the diagnosis and management of thyroid and related diseases.
Asunto(s)
Glándula Tiroides , Triyodotironina , Variación Biológica Poblacional , Biomarcadores , Femenino , Voluntarios Sanos , Humanos , Masculino , Valores de Referencia , Tirotropina , TiroxinaRESUMEN
OBJECTIVES: Testing for thyroid disease constitutes a high proportion of the workloads of clinical laboratories worldwide. The setting of analytical performance specifications (APS) for testing methods and aiding clinical interpretation of test results requires biological variation (BV) data. A critical review of published BV studies of thyroid disease related measurands has therefore been undertaken and meta-analysis applied to deliver robust BV estimates. METHODS: A systematic literature search was conducted for BV studies of thyroid related analytes. BV data from studies compliant with the Biological Variation Data Critical Appraisal Checklist (BIVAC) were subjected to meta-analysis. Global estimates of within subject variation (CVI) enabled determination of APS (imprecision and bias), indices of individuality, and indicative estimates of reference change values. RESULTS: The systematic review identified 17 relevant BV studies. Only one study (EuBIVAS) achieved a BIVAC grade of A. Methodological and statistical issues were the reason for B and C scores. The meta-analysis derived CVI generally delivered lower APS for imprecision than the mean CVA of the studies included in this systematic review. CONCLUSIONS: Systematic review and meta-analysis of studies of BV of thyroid disease biomarkers have enabled delivery of well characterized estimates of BV for some, but not all measurands. The newly derived APS for imprecision for both free thyroxine and triiodothyronine may be considered challenging. The high degree of individuality identified for thyroid related measurands reinforces the importance of RCVs. Generation of BV data applicable to multiple scenarios may require definition using "big data" instead of the demanding experimental approach.
Asunto(s)
Lista de Verificación , Glándula Tiroides , Biomarcadores , Pruebas Hematológicas , Humanos , Valores de ReferenciaRESUMEN
OBJECTIVES: Within- and between-subject biological variation (BV) estimates have many applications in laboratory medicine. However, robust high-quality BV estimates are lacking for many populations, such as athletes. This study aimed to deliver BV estimates of 29 routine laboratory measurands derived from a Biological Variation Data Critical Appraisal Checklist compliant design in a population of high-endurance athletes. METHODS: Eleven samples per subject were drawn from 30 triathletes monthly, during a whole sport season. Serum samples were measured in duplicate for proteins, liver enzymes, lipids and kidney-related measurands on an Advia2400 (Siemens Healthineers). After outlier and homogeneity analysis, within-subject (CVI) and between-subject (CVG) biological variation estimates were delivered (CV-ANOVA and log-ANOVA, respectively) and a linear mixed model was applied to analyze the effect of exercise and health related variables. RESULTS: Most CVI estimates were similar or only slightly higher in athletes compared to those reported for the general population, whereas two- to three-fold increases were observed for amylase, ALT, AST and ALP. No effect of exercise and health related variables were observed on the CVI estimates. For seven measurands, data were not homogeneously distributed and BV estimates were therefore not reported. CONCLUSIONS: The observation of higher CVI estimates in athletes than what has been reported for the general population may be related to physiological stress over time caused by the continuous practice of exercise. The BV estimates derived from this study could be applied to athlete populations from disciplines in which they exercise under similar conditions of intensity and duration.
Asunto(s)
Atletas , Proteínas , Amilasas , Variación Biológica Poblacional , HumanosRESUMEN
OBJECTIVES: Reliable biological variation (BV) data are required for the clinical use of tumor markers in the diagnosis and monitoring of treatment effects in cancer. The European Biological Variation Study (EuBIVAS) was established by the EFLM Biological Variation Working Group to deliver BV data for clinically important measurands. In this study, EuBIVAS-based BV estimates are provided for cancer antigen (CA) 125, CA 15-3, CA 19-9, carcinoembryonic antigen, cytokeratin-19 fragment, alpha-fetoprotein and human epididymis protein 4. METHODS: Subjects from five European countries were enrolled in the study, and weekly samples were collected from 91 healthy individuals (53 females and 38 males; 21-69 years old) for 10 consecutive weeks. All samples were analyzed in duplicate within a single run. After excluding outliers and homogeneity analysis, the BVs of tumor markers were determined by CV-ANOVA on trend-corrected data, when relevant (Røraas method). RESULTS: Marked individuality was found for all tumor markers. CYFRA 21-1 was the measurand with the highest index of individuality (II) at 0.67, whereas CA 19-9 had the lowest II at 0.07. The CV I s of HE4, CYFRA 21-1, CA 19-9, CA 125 and CA 15-3 of pre- and postmenopausal females were significantly different from each other. CONCLUSIONS: This study provides updated BV estimates for several tumor markers, and the findings indicate that marked individuality is characteristic. The use of reference change values should be considered when monitoring treatment of patients by means of tumor markers.
Asunto(s)
Biomarcadores de Tumor , Queratina-19 , Adulto , Anciano , Antígenos de Neoplasias , Variación Biológica Poblacional , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto JovenRESUMEN
Biological variation (BV) data have many important applications in laboratory medicine. Concerns about quality of published BV data led the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) 1st Strategic Conference to indicate need for new studies to generate BV estimates of required quality. In response, the EFLM Working Group on BV delivered the multicenter European Biological Variation Study (EuBIVAS). This review summarises the EuBIVAS and its outcomes. Serum/plasma samples were taken from 91 ostensibly healthy individuals for 10 consecutive weeks at 6 European centres. Analysis was performed by Siemens ADVIA 2400 (clinical chemistry), Cobas Roche 8000, c702 and e801 (proteins and tumor markers/hormones respectively), ACL Top 750 (coagulation parameters), and IDS iSYS or DiaSorin Liaison (bone biomarkers). A strict preanalytical and analytical protocol was applied. To determine BV estimates with 95% CI, CV-ANOVA after analysis of outliers, homogeneity and trend analysis or a Bayesian model was applied. EuBIVAS has so far delivered BV estimates for 80 different measurands. Estimates for 10 measurands (non-HDL cholesterol, S100-ß protein, neuron-specific enolase, soluble transferrin receptor, intact fibroblast growth-factor-23, uncarboxylated-unphosphorylated matrix-Gla protein, human epididymis protein-4, free, conjugated and %free prostate-specific antigen), prior to EuBIVAS, have not been available. BV data for creatinine and troponin I were obtained using two analytical methods in each case. The EuBIVAS has delivered high-quality BV data for a wide range of measurands. The BV estimates are for many measurands lower than those previously reported, having an impact on the derived analytical performance specifications and reference change values.
Asunto(s)
Química Clínica , Informe de Investigación , Teorema de Bayes , Creatinina , Humanos , Masculino , Estudios Multicéntricos como Asunto , Antígeno Prostático EspecíficoRESUMEN
OBJECTIVES: The estimates of biological variation (BV) have traditionally been determined using direct methods, which present limitations. In response to this issue, two papers have been published addressing these limitations by employing indirect methods. Here, we present a new procedure, based on indirect methods that analyses data collected within a multicenter pilot study. Using this method, we obtain CVI estimates and calculate confidence intervals (CI), using the EFLM-BVD CVI estimates as gold standard for comparison. METHODS: Data were collected over a 18-month period for 7 measurands, from 3 Spanish hospitals; inclusion criteria: patients 18-75 years with more than two determinations. For each measurand, four different strategies were carried out based on the coefficient of variation ratio (rCoeV) and based on the use of the bootstrap method (OS1, RS2 and RS3). RS2 and RS3 use symmetry reference change value (RCV) to clean database. RESULTS: RS2 and RS3 had the best correlation for the CVI estimates with respect to EFLM-BVD. RS2 used the symmetric RCV value without eliminating outliers, while RS3 combined RCV and outliers. When using the rCoeV and OS1 strategies, an overestimation of the CVI value was obtained. CONCLUSIONS: Our study presents a new strategy for obtaining robust CVI estimates using an indirect method together with the value of symmetric RCV to select the target population. The CVI estimates obtained show a good correlation with those published in the EFLM-BVD database. Furthermore, our strategy can resolve some of the limitations encountered when using direct methods such as calculating confidence intervals.
Asunto(s)
Minería de Datos , Bases de Datos Factuales , Humanos , Proyectos Piloto , Valores de ReferenciaRESUMEN
OBJECTIVES: Kidney markers are some of the most frequently used laboratory tests in patient care, and correct clinical decision making depends upon knowledge and correct application of biological variation (BV) data. The aim of this study was to review available BV data and to provide updated BV estimates for the following kidney markers in serum and plasma; albumin, creatinine, cystatin C, chloride, potassium, sodium and urea. CONTENT: Relevant studies were identified from a historical BV database as well as by systematic literature searches. Retrieved publications were appraised by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Meta-analyses of BIVAC compliant studies with similar design were performed to deliver global estimates of within-subject (CVI) and between-subject (CVG) BV estimates. Out of the 61 identified papers, three received a BIVAC grade A, four grade B, 48 grade C, five grade D grade and one was not appraised as it did not report numerical BV estimates. Most studies were identified for creatinine (n=48). BV estimates derived from the meta-analysis were in general lower than previously reported estimates for all analytes except urea. For some measurands, BV estimates may be influenced by age or states of health, but further data are required. SUMMARY: This review provides updated global BV estimates for kidney related measurands. For all measurands except for urea, these estimates were lower than previously reported. OUTLOOK: For the measurands analyzed in this review, there are sufficient well-designed studies available to publish a trustworthy estimate of BV. However, for a number of newly appearing kidney markers no suitable data is available and additional studies are required.
Asunto(s)
Riñón , Urea , Biomarcadores , Creatinina , HumanosRESUMEN
OBJECTIVES: Biological variation data (BV) can be used for different applications, but this depends on the availability of robust and relevant BV data. In this study, we aimed to summarize and appraise BV studies for tumor markers, to examine the influence of study population characteristics and concentrations on BV estimates and to discuss the applicability of BV data for tumor markers in clinical practice. METHODS: Studies reporting BV data for tumor markers related to gastrointestinal, prostate, breast, ovarian, haematological, lung, and dermatological cancers were identified by a systematic literature search. Relevant studies were evaluated by the Biological Variation Data Critical Appraisal Checklist (BIVAC) and meta-analyses were performed for BIVAC compliant studies to deliver global estimates of within-subject (CVI) and between-subject (CVG) BV with 95% CI. RESULTS: The systematic review identified 49 studies delivering results for 22 tumor markers; four papers received BIVAC grade A, 3 B, 27 C and 15 D. Out of these, 29 CVI and 29 CVG estimates met the criteria to be included in the meta-analysis. Robust data are lacking to conclude on the relationship between BV and different disease states and tumor marker concentrations. CONCLUSIONS: This review identifies a lack of high-quality BV studies for many tumor markers and a need for delivery of BIVAC compliant studies, including in different disease states and tumor marker concentrations. As of yet, the state-of-the-art may still be the most appropriate model to establish analytical performance specifications for the majority of tumor markers.
Asunto(s)
Biomarcadores de Tumor , Lista de Verificación , Humanos , MasculinoRESUMEN
OBJECTIVES: Trace elements (TrEL) are nutritionally essential components in maintaining health and preventing diseases. There is a lack of reliable biological variation (BV) data for TrELs, required for the diagnosis and monitoring of TrEL disturbances. In this study, we aimed to provide updated within- and between-subject BV estimates for zinc (Zn), copper (Cu) and selenium (Se). METHODS: Weekly serum samples were drawn from 68 healthy subjects (36 females and 32 males) for 10 weeks and stored at -80 °C prior to analysis. Serum Zn, Cu and Se levels were measured using inductively-coupled plasma mass spectrometry (ICP-MS). Outlier and variance homogeneity analyses were performed followed by CV-ANOVA (Røraas method) to determine BV and analytical variation estimates with 95% CI and the associated reference change values (RCV) for all subjects, males and females. RESULTS: Significant differences in mean concentrations between males and females were observed, with absolute and relative (%) differences for Zn at 0.5 µmol/L (3.5%), Cu 2.0 µmol/L (14.1%) and Se 0.06 µmol/L (6.0%). The within-subject BV (CVI [95% CI]) estimates were 8.8% (8.2-9.3), 7.8% (7.3-8.3) and 7.7% (7.2-8.2) for Zn, Cu and Se, respectively. Within-subject biological variation (CVI) estimates derived for male and female subgroups were similar for all three TrELs. Marked individuality was observed for Cu and Se. CONCLUSIONS: The data of this study provides updated BV estimates for serum Zn, Cu and Se derived from a stringent protocol and state of the art methodologies. Furthermore, Cu and Se display marked individuality, highlighting that population based reference limits should not be used in the monitoring of patients.