1.
Eur Radiol ; 32(7): 4537-4546, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35190891

RESUMEN

OBJECTIVES: Visualization of the bone distribution is an important prerequisite for MRI-guided high-intensity focused ultrasound (MRI-HIFU) treatment planning of bone metastases. In this context, we evaluated MRI-based synthetic CT (sCT) imaging for the visualization of cortical bone. METHODS: MR and CT images of nine patients with pelvic and femoral metastases were retrospectively analyzed in this study. The metastatic lesions were osteolytic, osteoblastic or mixed. sCT were generated from pre-treatment or treatment MR images using a UNet-like neural network. sCT was qualitatively and quantitatively compared to CT in the bone (pelvis or femur) containing the metastasis and in a region of interest placed on the metastasis itself, through mean absolute difference (MAD), mean difference (MD), Dice similarity coefficient (DSC), and root mean square surface distance (RMSD). RESULTS: The dataset consisted of 3 osteolytic, 4 osteoblastic and 2 mixed metastases. For most patients, the general morphology of the bone was well represented in the sCT images and osteolytic, osteoblastic and mixed lesions could be discriminated. Despite an average timespan between MR and CT acquisitions of 61 days, in bone, the average (± standard deviation) MAD was 116 ± 26 HU, MD - 14 ± 66 HU, DSC 0.85 ± 0.05, and RMSD 2.05 ± 0.48 mm and, in the lesion, MAD was 132 ± 62 HU, MD - 31 ± 106 HU, DSC 0.75 ± 0.2, and RMSD 2.73 ± 2.28 mm. CONCLUSIONS: Synthetic CT images adequately depicted the cancellous and cortical bone distribution in the different lesion types, which shows its potential for MRI-HIFU treatment planning. KEY POINTS: • Synthetic computed tomography was able to depict bone distribution in metastatic lesions. • Synthetic computed tomography images intrinsically aligned with treatment MR images may have the potential to facilitate MR-HIFU treatment planning of bone metastases, by combining visualization of soft tissues and cancellous and cortical bone.


Asunto(s)
Neoplasias Óseas , Imagen por Resonancia Magnética , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/terapia , Estudios de Factibilidad , Fémur/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Pelvis , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
2.
Magn Reson Med ; 86(5): 2647-2655, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34061390

RESUMEN

PURPOSE: To demonstrate that interleaved MR thermometry can monitor temperature in water and fat with adequate temporal resolution. This is relevant for high intensity focused uUltrasounds (HIFU) treatment of bone lesions, which are often found near aqueous tissues, as muscle, or embedded in adipose tissues, as subcutaneous fat and bone marrow. METHODS: Proton resonance frequency shift (PRFS)-based thermometry scans and T1 -based 2D variable flip angle (2D-VFA) thermometry scans were acquired alternatingly over time. Temperature in water was monitored using PRFS thermometry, and in fat by 2D-VFA thermometry with slice profile effect correction. The feasibility of interleaved water/fat temperature monitoring was studied ex vivo in porcine bone during MR-HIFU sonication. Precision and stability of measurements in vivo were evaluated in a healthy volunteer under non-heating conditions. RESULTS: The method allowed observing temperature change over time in muscle and fat, including bone marrow, during MR-HIFU sonication, with a temporal resolution of 6.1 s. In vivo, the apparent temperature change was stable on the time scale of the experiment: In 7 min the systematic drift was <0.042°C/min in muscle (PRFS after drift correction) and <0.096°C/min in bone marrow (2D-VFA). The SD of the temperature change averaged over time was 0.98°C (PRFS) and 2.7°C (2D-VFA). CONCLUSIONS: Interleaved MR thermometry allows temperature measurements in water and fat with a temporal resolution high enough for monitoring HIFU ablation. Specifically, combined fat and water thermometry provides uninterrupted information on temperature changes in tissue close to the bone cortex.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Termometría , Animales , Humanos , Imagen por Resonancia Magnética , Porcinos , Temperatura , Agua
3.
NMR Biomed ; 34(8): e4542, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34031938

RESUMEN

PURPOSE: To perform dynamic T1 mapping using a 2D variable flip angle (VFA) method, a correction for the slice profile effect is needed. In this work we investigated the impact of flip angle selection and excitation RF pulse profile on the performance of slice profile correction when applied to T1 mapping over a range of T1 values. METHODS: A correction of the slice profile effect is proposed, based on Bloch simulation of steady-state signals. With this correction, Monte Carlo simulations were performed to assess the accuracy and precision of 2D VFA T1 mapping in the presence of noise, for RF pulses with time-bandwidth products of 2, 3 and 10 and with flip angle pairs in the range [1°-90°]. To evaluate its performance over a wide range of T1 , maximum errors were calculated for six T1 values between 50 ms and 1250 ms. The method was demonstrated using in vitro and in vivo experiments. RESULTS: Without corrections, 2D VFA severely underestimates T1 . Slice profile errors were effectively reduced with the correction based on simulations, both in vitro and in vivo. The precision and accuracy of the method depend on the nominal T1 values, the FA pair, and the RF pulse shape. FA pairs leading to <5% errors in T1 can be identified for the common RF shapes, for T1 values between 50 ms and 1250 ms. CONCLUSIONS: 2D VFA T1 mapping with Bloch-simulation-based correction can deliver T1 estimates that are accurate and precise to within 5% over a wide T1 range.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Humanos , Fantasmas de Imagen , Ondas de Radio , Reproducibilidad de los Resultados
4.
Magn Reson Med ; 83(3): 962-973, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31544289

RESUMEN

PURPOSE: To demonstrate that proton resonance frequency shift MR thermometry (PRFS-MRT) acquisition with nonselective free induction decay (FID), combined with coil sensitivity profiles, allows spatially resolved B0 drift-corrected thermometry. METHODS: Phantom experiments were performed at 1.5T and 3T. Acquisition of PRFS-MRT and FID were performed during MR-guided high-intensity focused ultrasound heating. The phase of the FIDs was used to estimate the change in angular frequency δωdrift per coil element. Two correction methods were investigated: (1) using the average δωdrift over all coil elements (0th-order) and (2) using coil sensitivity profiles for spatially resolved correction. Optical probes were used for independent temperature verification. In-vivo feasibility of the methods was evaluated in the leg of 1 healthy volunteer at 1.5T. RESULTS: In 30 minutes, B0 drift led to an apparent temperature change of up to -18°C and -98°C at 1.5T and 3T, respectively. In the sonicated area, both corrections had a median error of 0.19°C at 1.5T and -0.54°C at 3T. At 1.5T, the measured median error with respect to the optical probe was -1.28°C with the 0th-order correction and improved to 0.43°C with the spatially resolved correction. In vivo, without correction the spatiotemporal median of the apparent temperature was at -4.3°C and interquartile range (IQR) of 9.31°C. The 0th-order correction had a median of 0.75°C and IQR of 0.96°C. The spatially resolved method had the lowest median at 0.33°C and IQR of 0.80°C. CONCLUSION: FID phase information from individual receive coil elements allows spatially resolved B0 drift correction in PRFS-based MRT.


Asunto(s)
Pierna/diagnóstico por imagen , Espectroscopía de Resonancia Magnética , Algoritmos , Voluntarios Sanos , Ultrasonido Enfocado de Alta Intensidad de Ablación , Calor , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Protones , Reproducibilidad de los Resultados , Termografía , Termometría
5.
J Magn Reson Imaging ; 47(3): 692-701, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28646608

RESUMEN

PURPOSE: To demonstrate that fluid filling of the digestive tract improves the performance of respiratory motion-compensated proton resonance frequency shift (PRFS)-based magnetic resonance (MR) thermometry in the pancreas. MATERIALS AND METHODS: In seven volunteers (without heating), we evaluated PRFS thermometry in the pancreas with and without filling of the surrounding digestive tract. All data acquisition was performed at 1.5T, then all datasets were analyzed and compared with three different PRFS respiratory motion-compensated thermometry methods: gating, multibaseline, and referenceless. The temperature precision of the different methods was evaluated by assessing temperature standard deviation over time, while a simulation experiment was used to study the accuracy of the methods. RESULTS: Without fluid intake, errors in temperature precision in the pancreas up to 10°C were observed for all evaluated methods. After liquid intake, temperature precision improved to median values between 1.8 and 2.9°C. The simulations showed that gating had the lowest accuracy, with errors up to 7°C. Multibaseline and referenceless thermometry performed better, with a median error in the pancreas between -3 and +3°C after fluid intake, for all volunteers. CONCLUSION: Preparation of the digestive tract near the pancreas by filling it with fluid improved MR thermometry precision and accuracy for all common respiratory motion-compensated methods evaluated. These improvements are attributed to reducing field inhomogeneity in the pancreas. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:692-701.


Asunto(s)
Jugos de Frutas y Vegetales , Tracto Gastrointestinal , Imagen por Resonancia Magnética/métodos , Páncreas/diagnóstico por imagen , Termometría/métodos , Adulto , Humanos , Masculino , Valores de Referencia
6.
Trials ; 23(1): 1061, 2022 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-36582001

RESUMEN

BACKGROUND: Cancer-induced bone pain (CIBP), caused by bone metastases, is a common complication of cancer and strongly impairs quality of life (QoL). External beam radiotherapy (EBRT) is the current standard of care for treatment of CIBP. However, approximately 45% of patients have no adequate pain response after EBRT. Magnetic resonance image-guided high-intensity focused ultrasound (MR-HIFU) may improve pain palliation in this patient population. The main objective of this trial was to compare MR-HIFU, EBRT, and MR-HIFU + EBRT for the palliative treatment of bone metastases. METHODS/DESIGN: The FURTHER trial is an international multicenter, three-armed randomized controlled trial. A total of 216 patients with painful bone metastases will be randomized in a 1:1:1 ratio to receive EBRT only, MR-HIFU only, or combined treatment with EBRT followed by MR-HIFU. During a follow-up period of 6 months, patients will be contacted at eight time points to retrieve information about their level of pain, QoL, and the occurrence of (serious) adverse events. The primary outcome of the trial is pain response at 14 days after start of treatment. Secondary outcomes include pain response at 14 days after trial enrolment, pain scores (daily until the 21st day and at 4, 6, 12 and 24 weeks), toxicity, adverse events, QoL, and survival. Cost-effectiveness and cost-utility analysis will be conducted. DISCUSSION: The FURTHER trial aims to evaluate the effectiveness and cost-effectiveness of MR-HIFU-alone or in combination with EBRT-compared to EBRT to relieve CIBP. The trial will be performed in six hospitals in four European countries, all of which are partners in the FURTHER consortium. TRIAL REGISTRATION: The FURTHER trial is registered under the Netherlands Trials Register number NL71303.041.19 and ClinicalTrials.gov registration number NCT04307914. Date of trial registration is 13-01-2020.


Asunto(s)
Neoplasias Óseas , Dolor en Cáncer , Humanos , Cuidados Paliativos/métodos , Calidad de Vida , Manejo del Dolor/métodos , Dolor , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/radioterapia , Dolor en Cáncer/radioterapia , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
7.
Clin Transl Radiat Oncol ; 27: 57-63, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33532631

RESUMEN

BACKGROUND: Cancer induced bone pain (CIBP) strongly interferes with patient's quality of life. Currently, the standard of care includes external beam radiotherapy (EBRT), resulting in pain relief in approximately 60% of patients. Magnetic Resonance guided High Intensity Focused Ultrasound (MR-HIFU) is a promising treatment modality for CIBP. METHODS: A single arm, R-IDEAL stage I/IIa study was conducted. Patients presenting at the department of radiation oncology with symptomatic bone metastases in the appendicular skeleton, as well as in the sacrum and sternum were eligible for inclusion. All participants underwent EBRT, followed by MR-HIFU within 4 days. Safety and feasibility were assessed, and pain scores were monitored for 4 weeks after completing the combined treatment. RESULTS: Six patients were enrolled. Median age was 67 years, median lesion diameter was 56,5 mm. In all patients it was logistically possible to plan and perform the MR-HIFU treatment within 4 days after EBRT. All patients tolerated the combined procedure well. Pain response was reported by 5 out of 6 patients at 7 days after completion of the combined treatment, and stabilized on 60% at 4 weeks follow up. No treatment related serious adverse events occurred. CONCLUSION: This is the first study to combine EBRT with MR-HIFU. Our results show that combined EBRT and MR-HIFU in first-line treatment of CIBP is safe and feasible, and is well tolerated by patients. Superiority over standard EBRT, in terms of (time to) pain relief and quality of life need to be evaluated in comparative (randomized) study.

8.
Eur Radiol Exp ; 3(1): 14, 2019 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-30923930

RESUMEN

The visualisation of the celiac plexus using respiratory- and cardiac-triggered three-dimensional (3D) sheath inked rapid acquisition with refocused echoes imaging (SHINKEI) was evaluated. After ethical approval and written informed consent, eight volunteers (age 27 ± 5 years, mean ± standard deviation) were scanned at 1.5 and 3 T. Displacement of the celiac ganglia due to aortic pulsatility was studied on axial single-slice breath-hold balanced turbo field-echo cine sequences in five volunteers and found to be 3.0 ± 0.5 mm (left) and 3.1 ± 0.4 mm (right). Respiratory- and cardiac-triggered 3D SHINKEI images were compared to respiratory- and cardiac-triggered fat-suppressed 3D T2-weighted turbo spin-echo and respiratory-triggered 3D SHINKEI in all volunteers. Visibility of the celiac ganglia was rated by three radiologists as visible or non-visible. On 3D SHINKEI with double-triggering at 1.5 T, the left and right ganglia were seen by all observers in 7/8 and 8/8 volunteers, respectively. At 3 T, this was the case for 6/8 and 7/8 volunteers, respectively. The nerve-to-muscle signal ratio increased from 1.9 ± 0.5 on fat-suppressed 3D T2-weighted turbo spin-echo to 4.7 ± 0.8 with 3D SHINKEI. Anatomical validation was performed in a human cadaver. An expert in anatomy confirmed that the hyperintense structure visible on ex vivo 3D SHINKEI scans was the celiac plexus. In conclusion, double-triggering allowed visualisation of the celiac plexus using 3D SHINKEI at both 1.5 T and 3 T.


Asunto(s)
Cavidad Abdominal/diagnóstico por imagen , Plexo Celíaco/diagnóstico por imagen , Corazón/fisiología , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Respiración , Adulto , Humanos , Neuroimagen , Factores de Tiempo , Adulto Joven