1.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37208301

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Asunto(s)
Monitoreo Fisiológico , Telemetría , Humanos
2.
Heart Rhythm ; 20(9): e92-e144, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37211145

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Asunto(s)
Desfibriladores Implantables , Tecnología de Sensores Remotos , Humanos
3.
J Arrhythm ; 39(3): 250-302, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37324757

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.

4.
HeartRhythm Case Rep ; 10(5): 378, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38799596
9.
Cardiol Rev ; 25(1): 36-42, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27922469

RESUMEN

Many patients with implantable cardioverter-defibrillators (ICD) want to participate in sports and many need or wish to operate a personal motor vehicle. Healthcare providers need to advise patients regarding restrictions related to these activities in the context of the clinical indication for the ICD. Ethical considerations need to be considered when advising ICD patients of restrictions to reduce risk of injury to themselves and to others when participating in either sports or driving. Shared decision-making is necessary to have ICD patients understand and comply with recommended restrictions. Guidelines have been developed based on available studies; however, studies assessing the need for ICD patients to restrict these activities are observational and often out of date. More recent studies challenge driving and sports restrictions that are recommended by the guidelines. Recommendations to ICD patients must be individualized yet be compliant with the guidelines, and need to adapt to changes in a patients' condition.


Asunto(s)
Conducción de Automóvil , Desfibriladores Implantables/ética , Deportes/ética , Toma de Decisiones , Humanos
10.
Cardiol Rev ; 24(6): 282-287, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27548691

RESUMEN

The use of implantable cardioverter defibrillators (ICD) has favorably impacted the prevention and treatment of sudden cardiac death (SCD) associated with ventricular arrhythmias. However, there are situations where an ICD cannot be immediately implanted, even though the patient is at high risk for SCD. The wearable cardioverter defibrillator (WCD) is a unique technology that can bridge this gap for patients. The WCD has been demonstrated to terminate ventricular tachycardia/fibrillation if worn and used correctly. With proper training, it is relatively easy to put on, maintain, and use. Most patients are compliant and are able to consistently wear the device. The WCD negates the infection risk or procedural complications associated with insertion and possible extraction of leads, as with an ICD. In terms of primary prevention of ventricular tachycardia/fibrillation in patients with a left ventricular ejection fraction ≤35%, prospective, randomized studies evaluating the survival of patients utilizing the WCD will need to be performed before evidenced-based criteria for its use can be established. On the basis of current data, WCD use for those awaiting heart transplant, for those with ICD indications status post-ICD explant, and for high-risk SCD patients with possible reversible cardiomyopathy appears to be a reasonable approach on the basis of current data.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores , Humanos , Cooperación del Paciente , Selección de Paciente
12.
Heart Rhythm ; 5(8): 1134-41, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18675224

RESUMEN

BACKGROUND: Atrial fibrillation catheter ablation is frequently guided by identification of fractionated electrograms, which are thought to be critical for maintenance of the arrhythmia. Objective automated means for identifying fractionation independent of physician interpretation have not been standardized or validated. OBJECTIVE: The purpose of this study was to standardize and validate an automated algorithm to rapidly identify fractionated electrograms for high-density atrial fibrillation fractionation mapping. METHODS: Left and right atrial fractionation maps were generated by EnSite NavX 6.0 software, using standardized ablation catheters in eight patients with atrial fibrillation. Two blinded electrophysiologists interpreted all electrograms as either fractionated or not fractionated. A stepwise approach was used to optimize automated settings to accurately identify fractionation. High-density fractionation maps were generated with a 20-pole mapping catheter in eight other patients. Two blinded electrophysiologists interpreted all electrograms as near field or far field. The algorithm was refined to optimize settings to exclude far-field signals and retain near-field signals. The sampling segment length was adjusted to optimize recording time to ensure reproducibility. RESULTS: Using 1,514 points, the automated software achieved sensitivity of 0.75 and specificity of 0.80 for identification of fractionated electrograms. Using 725 points collected via multipole catheters with optimal automated settings, 94% of near-field fractionated electrograms were accurately identified. A 6-second sampling length was needed for reproducible fractionation measurements. CONCLUSION: Standardized settings of EnSite NavX 6.0 software with 6-second data collection per point can rapidly and accurately generate high-density fractionation maps independent of physician electrogram interpretation. This may allow for an automated, standardized approach to atrial fibrillation fractionated ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Endocardio/patología , Algoritmos , Fibrilación Atrial/fisiopatología , Mapeo del Potencial de Superficie Corporal/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad