Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Curr Cardiol Rep ; 26(5): 359-372, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38619711

RESUMEN

PURPOSE OF REVIEW: Acute coronary syndromes (ACS) are a major global health concern. Percutaneous coronary intervention (PCI) with new-generation drug-eluting stents (DES) has been endorsed as safe and effective in the management of culprit and non-culprit lesions of ACS. However, permanent metallic implants may have drawbacks, including the need for prolonged dual antiplatelet therapy (DAPT) and the risk of long-term stent-related complications. An alternative approach using drug-coated balloons (DCBs) is gaining growing interest, having the potential of delivering therapy directly to vulnerable plaques, avoiding the need for permanent metallic implants, and potentially allowing for better long-term medical treatment. Despite limited evidence, DCB is being explored in several patients' subgroups. This review aims to discuss the existing evidence regarding DCB in ACS management. RECENT FINDINGS: DCB appears to be a promising strategy in the management of ACS, showing comparable angiographic and clinical results as compared to new-generation DES in relatively small clinical trials or large prospective registries. The advantage of avoiding permanent implants is particularly appealing in this setting, where DCB has the potential of delivering anti-atherogenic local therapy directly to vulnerable plaques still amenable to atherogenic regression. This review seeks to underline the theoretical background of DCB use and reports the available evidence in its support in the specific setting of ACS. In the context of ACS, the use of DCB is highly attractive, offering a dedicated anti-atherogenic local therapy, capable of addressing a broad range of vulnerable plaques and patients.


Asunto(s)
Síndrome Coronario Agudo , Angioplastia Coronaria con Balón , Stents Liberadores de Fármacos , Humanos , Síndrome Coronario Agudo/terapia , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Materiales Biocompatibles Revestidos , Inhibidores de Agregación Plaquetaria/uso terapéutico
2.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37694603

RESUMEN

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
3.
Catheter Cardiovasc Interv ; 99(3): 736-745, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34761492

RESUMEN

BACKGROUND: Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) disagree in about 20% of intermediate coronary lesions. As the physiological pattern of coronary artery disease has a significant influence on FFR-iFR discordance, we sought to assess it may impact on the diagnostic accuracy of quantitative flow reserve (QFR). METHODS: One hundred and ninety-four patients with 224 intermediate coronary lesions were investigated with iFR, FFR, and QFR. The physiological pattern of disease was assessed with iFR Scout pullback and QFR virtual pullback in all the cases. RESULTS: A predominantly physiologically focal pattern was observed in 81 (36.2%) lesions, whereas a predominantly physiologically diffuse was observed in 143 (63.8%) cases. QFR demonstrated a significant correlation (r = 0.581, p < 0.001) and a substantial agreement with iFR, both in diffuse (AUC = 0.798) and in focal (AUC = 0.812) pattern of disease. Discordance between QFR and iFR was observed in 51 (22.8%) lesions, consisting of iFR+/QFR- (64.7%) and iFR-/QFR+ (35.3%). Notably, the physiological pattern of disease was the only variable significantly associated with iFR/QFR discordance. QFR virtual pullback demonstrated an excellent agreement (83.9%) with iFR Scout pullback in classifying the physiological pattern of disease. CONCLUSIONS: QFR has a good diagnostic accuracy in assessing myocardial ischemia independently of the pattern of coronary disease. However, the physiological pattern of disease has an influence on the QFR/iFR discordance, which occurs in ~20% of the cases. The QFR virtual pullback correctly defined the physiological pattern of disease in the majority of the cases using the iFR pullback as reference.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Cateterismo Cardíaco , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
4.
Nat Rev Cardiol ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38710772

RESUMEN

This Perspective article is a form of 'pastiche', inspired by the 1993 review by Lincoff and Topol entitled 'Illusion of reperfusion', and explores how their concept continues to apply to percutaneous revascularization in patients with coronary artery disease and ischaemia. Just as Lincoff and Topol argued that reperfusion of acute myocardial infarction was facing unresolved obstacles that hampered clinical success in 1993, we propose that challenging issues are similarly jeopardizing the potential benefits of stent-based angioplasty today. By analysing the appropriateness and efficacy of percutaneous coronary intervention (PCI), we emphasize the limitations of relying solely on visual angiographic guidance, which frequently leads to inappropriate stenting and overtreatment in up to one-third of patients and the associated increased risk of periprocedural myocardial infarction. The lack of optimal revascularization observed in half of patients undergoing PCI confers risks such as suboptimal physiology after PCI, residual angina and long-term stent-related events, leaving an estimated 76% of patients with an 'illusion of revascularization'. These outcomes highlight the need to refine our diagnostic tools by integrating physiological assessments with targeted intracoronary imaging and emerging strategies, such as co-registration systems and angiography-based computational methods enhanced by artificial intelligence, to achieve optimal revascularization outcomes.

5.
Heart ; 110(8): 603-612, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38040448

RESUMEN

OBJECTIVES: This study aimed to evaluate the prognostic value of coronary microvascular dysfunction (CMD) at long term after transcatheter aortic valve implantation (TAVI) and to explore its relationship with extravalvular cardiac damage (EVCD). Moreover, we sought to test the correlation between angiography-derived index of microcirculatory resistance (IMRangio) and invasive IMR in patients with aortic stenosis (AS). METHODS: This was a retrospective analysis of the Verona Valvular Heart Disease Registry (Italy) including 250 patients (83 (80-86) years, 53% female) with severe AS who underwent TAVI between 2019 and 2021. IMRangio was calculated offline using a computational flow model applied to coronary angiography obtained during the TAVI workup. CMD was defined as IMRangio ≥30 units.The primary endpoint was the composite of cardiovascular death and rehospitalisation for heart failure (HF). Advanced EVCD was defined as pulmonary circulation impairment, severe tricuspid regurgitation or right ventricular dysfunction.The correlation between IMR and IMRangio was prospectively assessed in 31 patients undergoing TAVI. RESULTS: The primary endpoint occurred in 28 (11.2%) patients at a median follow-up of 22 (IQR 12-30) months. Patients with CMD met the primary endpoint more frequently than those without CMD (22.9% vs 2.8%, p<0.0001). Patients with CMD were more frequently characterised by advanced EVCD (33 (31.4%) vs 27 (18.6%), p=0.024). CMD was an independent predictor of adverse outcomes (adjusted HR 6.672 (2.251 to 19.778), p=0.001) and provided incremental prognostic value compared with conventional clinical and imaging variables. IMRangio demonstrated fair correlation with IMR. CONCLUSIONS: CMD is an independent predictor of cardiovascular mortality and HF after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Isquemia Miocárdica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Microcirculación , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
6.
Artículo en Inglés | MEDLINE | ID: mdl-38775442

RESUMEN

Coronary physiological assessment has garnered extensive application in managing patients with coronary artery disease, encompassing both acute and chronic scenarios. Beyond the historical purpose as tool to define the hemodynamic significance of a given artery lesion, coronary artery physiology allows for a complete investigation of epicardial and microvascular circulation. The longitudinal assessment of the distribution pattern of coronary disease based on pressure wire technology provides crucial information to define the best management and procedural planning. Moreover, post-percutaneous coronary intervention physiology reassessment showed a strong association with clinical outcomes and, more importantly, it can spot residual pressure gradients potentially amenable to further intervention and optimization. Growing evidence about the non-invasive angiography-based indices helps to overcome the limitations of the use of intracoronary physiology. This review aims to provide an overview of different utilizations of coronary physiology offering a historical perspective with a particular focus on current challenges and future potential applications.

7.
Clin Res Cardiol ; 113(7): 1017-1029, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38170246

RESUMEN

BACKGROUND: Cardiac allograft vasculopathy (CAV) is still the main drawback of heart transplantation (HTx) and percutaneous coronary intervention (PCI) is a palliative measure because of the high incidence of failure. OBJECTIVE: This study aimed to investigate the safety and efficacy of bioresorbable scaffolds (BRSs) as potential novel therapeutic tool for the treatment of coronary stenoses in CAV. METHODS: This is a multicenter, single-arm, prospective, open-label study (CART, NCT02377648), that included patients affected by advanced CAV treated with PCI and second-generation ABSORB BRS (Abbott Vascular). The primary endpoint was the incidence of 12-month angiographic in-segment scaffold restenosis (ISSR). Secondary endpoints were the incidence of major adverse cardiac events (MACEs) at 12- and 36-month follow-up and the incidence of ISSR at 36 months. A paired intracoronary imaging analysis at baseline and follow-up was also performed. RESULTS: Between 2015 and 2017 35 HTx patients were enrolled and treated for 44 coronary lesions with 51 BRSs. The primary endpoint occurred in 13.5% of the lesions (5/37), with a cumulative ISSR rate up to 3 years of 16.2% (6/37). Angiographic lumen loss was 0.40 ± 0.62 mm at 12 months and 0.53 ± 0.57 mm at 36 months. Overall survival rate was 91.4% and 74.3%, and MACEs incidence 14.2% and 31.4% at 12 and 36 months, respectively. At the paired intracoronary imaging analysis, a significant increase of the vessel external elastic membrane area in the treated segment and some progression of CAV proximally to the BRS were detected. CONCLUSIONS: BRS-based PCI for the treatment of CAV is feasible and safe, with an ISSR incidence similar to what reported in retrospective studies with drug-eluting stents.


Asunto(s)
Implantes Absorbibles , Angiografía Coronaria , Everolimus , Trasplante de Corazón , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Everolimus/administración & dosificación , Everolimus/farmacología , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Diseño de Prótesis , Andamios del Tejido , Stents Liberadores de Fármacos , Anciano , Estudios de Seguimiento , Enfermedad de la Arteria Coronaria/terapia , Aloinjertos , Inmunosupresores/uso terapéutico , Factores de Tiempo , Estenosis Coronaria , Vasos Coronarios/diagnóstico por imagen
8.
Artículo en Inglés | MEDLINE | ID: mdl-38664133

RESUMEN

Balloon angioplasty achieves luminal enlargement by fracturing the atherosclerotic intima at its point of least resistance, thereby creating a dissection plane and space with dehiscence of the intima from the media. This barotraumatic dissection triggers an inflammatory and proliferative reaction, resulting in a restenosis process at medium-term. In the era of plain old balloon angioplasty, quantitative angiographic studies at follow-up demonstrated that - the greater the acute luminal gain was after balloon angioplasty, the greater the late luminal loss was at follow-up. The interventional cardiologists coined the following motto "the more you gain, the more you lose". However, in the current era of drug coated balloon (DCB), it appears that this vexing conundrum could have been abrogated. A recently published DCB study in small de novo vessel has demonstrated that there was a slightly negative correlation between the volume of dissection assessed by optical coherence tomography and the angiographic late luminal loss (now gain) after Paclitaxel coated balloon treatment. In other words, the barotraumatic dissection does not necessarily herald a restenosis process in the era of DCB. This article revisits the mechanism of balloon angioplasty and explores how DCB with Paclitaxel may change the paradigm of balloon angioplasty as default treatment in CAD percutaneous treatment.

9.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982161

RESUMEN

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología , Diseño de Prótesis
10.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479968

RESUMEN

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología
11.
Artículo en Inglés | MEDLINE | ID: mdl-38749449

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

12.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38401656

RESUMEN

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Factores Sexuales , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Válvula Aórtica/cirugía
13.
Eur Heart J Case Rep ; 7(8): ytad309, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37539351

RESUMEN

Background: Physiology-guided coronary revascularization was shown to improve clinical outcomes in multiple patient subsets, whilst in those presenting with acute coronary syndromes, it seems to be associated with an excess of cardiovascular events. One of the major drawbacks in this setting is the potential deferral of non-flow-limiting but 'vulnerable' coronary plaques. Case summary: A 40-year-old patient presented with a myocardial infarction without ST-segment elevation (NSTEMI). At the invasive coronary angiography (ICA) a sub-occlusive stenosis on his left circumflex artery was detected and treated with percutaneous coronary intervention (PCI). The treatment of a concomitant intermediate eccentric focal stenosis on the right coronary artery (RCA) was deferred after a negative pressure wire-based physiological assessment. The patient was re-admitted 9 months later due to a recurrent NSTEMI, and a severe progression of the deferred RCA lesion was found at the ICA. In retrospect, an angiography-based assessment of physiological severity and plaque vulnerability of the non-culprit RCA stenosis by means of Murray's law-based QFR (µQFR) and radial wall strain (RWS) was performed. At baseline, µQFR value (0.90) corroborated the non-ischaemic findings of wire-based assessment. However, RWS analysis showed a marked hotspot (maximum RWS value 27.7%), indicating the presence of a vulnerable plaque. Discussion: Radial wall strain is a novel biomechanical deformation index derived from coronary angiography. Segments with high RWS are associated with lipid-rich plaques that are prone to progression and plaque rupture. Therefore, the identification of RWS hotspots might potentially improve the risk stratification of non-culprit lesions and empower secondary prevention strategies.

14.
Int J Cardiol ; 378: 11-19, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36796487

RESUMEN

BACKGROUND: Two-stent techniques for percutaneous coronary intervention (PCI) on left main (LM) bifurcation (LMB) lesions are associated with an increased risk of in-stent restenosis (ISR) at left circumflex artery (LCx) ostium but the underlying mechanisms are incompletely understood. This study sought to investigate the association between cyclic change of LM-LCx bending angle (BALM-LCx) and the risk of ostial LCx ISR following two-stent techniques. METHODS: In a retrospective cohort of patients undergoing two-stent PCI for LMB lesions, BALM-LCx and distal bifurcation angle (DBA) were computed with 3-dimensional angiographic reconstruction. The analysis was performed both at end-diastole and end-systole, and the angulation change throughout the cardiac cycle was defined as the cardiac motion-induced angulation change (∆CAngle). RESULTS: A total of 101 patients were included. The mean pre-procedural BALM-LCx was 66.8 ± 16.1° at end-diastole and 54.1 ± 13.3° at end-systole with a range of 13.0 ± 7.7°. Pre-procedural ∆CBALM-LCx > 16.4° was the most relevant predictor of ostial LCx ISR (adjusted OR 11.58, 95% CI 4.04-33.19; p < 0.001). Post-procedural ∆CBALM-LCx > 9.8° and stent-induced diastolic BALM-LCx change > 11.6° were also related with ostial LCx ISR. DBA was positively correlated with BALM-LCx and showed a weaker association of pre-procedural ∆CDBA > 14.5° with ostial LCx ISR (adjusted OR 6.87, 95% CI 2.57-18.37; p < 0.001). CONCLUSIONS: Three-dimensional angiographic bending angle is a feasible and reproducible novel method for LMB angulation measurement. A large pre-procedural cyclic change of BALM-LCx was associated with an increased risk of ostial LCx ISR following two-stent techniques.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Angiografía Coronaria/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Stents Liberadores de Fármacos/efectos adversos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Vasos Coronarios/patología , Stents/efectos adversos , Constricción Patológica
15.
Circ Cardiovasc Interv ; 16(10): e013185, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37712285

RESUMEN

BACKGROUND: Angiography-derived computational physiology is an appealing alternative to pressure-wire coronary physiology assessment. However, little is known about its reliability in the setting of severe aortic stenosis. This study sought to provide an integrated assessment of epicardial and microvascular coronary circulation by means of single-view angiography-derived physiology in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). METHODS: Pre-TAVI angiographic projections of 198 stenotic coronary arteries (123 patients) were analyzed by means of Murray's law-based quantitative flow ratio and angiography microvascular resistance. Wire-based reference measurements were available for comparison: fractional flow reserve (FFR) in all cases, instantaneous wave-free ratio in 148, and index of microvascular resistance in 42 arteries. RESULTS: No difference in terms of the number of ischemia-causing stenoses was detected between FFR ≤0.80 and Murray's law-based quantitative flow ratio ≤0.80 (19.7% versus 19.2%; P=0.899), while this was significantly higher when instantaneous wave-free ratio ≤0.89 (44.6%; P=0.001) was used. The accuracy of Murray's law-based quantitative flow ratio ≤0.80 in predicting pre-TAVI FFR ≤0.80 was significantly higher than the accuracy of instantaneous wave-free ratio ≤0.89 (93.4% versus 77.0%; P=0.001), driven by a higher positive predictive value (86.9% versus 50%). Similar findings were observed when considering post-TAVI FFR ≤0.80 as reference. In 82 cases with post-TAVI angiographic projections, Murray's law-based quantitative flow ratio values remained stable, with a low rate of reclassification of stenosis significance (9.9%), similar to FFR and instantaneous wave-free ratio. Angiography microvascular resistance demonstrated a significant correlation (Rho=0.458; P=0.002) with index of microvascular resistance, showing an area under the curve of 0.887 (95% CI, 0.752-0.964) in predicting index of microvascular resistance ≥25. CONCLUSIONS: Angiography-derived physiology provides a valid, reliable, and systematic assessment of the coronary circulation in a complex scenario, such as severe aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reserva del Flujo Fraccional Miocárdico/fisiología , Angiografía Coronaria , Reproducibilidad de los Resultados , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Vasos Coronarios/diagnóstico por imagen , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Índice de Severidad de la Enfermedad
16.
Int J Cardiovasc Imaging ; 39(1): 233-244, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36336756

RESUMEN

Coronary microvascular dysfunction (CMD) has been proposed as a key driver in the etiopathogenesis of Takotsubo syndrome (TTS), likely related to an "adrenergic storm" upon a susceptible microvascular circulation. The aim of our manuscript was to assess CMD in patients with TTS through the computation of the angiography-derived index of microcirculatory resistance (IMR) and its correlation with clinical presentation. Coronary angiograms of 41 consecutive TTS patients were retrospectively analyzed to derive angiography-based indices of CMD. Three indices (NH-IMRangio, AngioIMR and A-IMR) were calculated based on quantitative flow ratio. CMD was defined as an IMRangio value ≥ 25 units. The correlation between CMD and clinical presentation was then assessed. Median age was 76 years, 85.7% were women and mean left ventricular ejection fraction (LVEF) at first echocardiogram was 41.2%. Angiography-derived IMR was higher in left anterior descending artery (LAD) than circumflex and right coronary artery with either NH-IMRangio (53.9 ± 19.8 vs 35.8 ± 15.4 vs 40.8 ± 18.5, p-value < 0.001), AngioIMR (47.2 ± 17.3 vs 31.8 ± 12.2 vs 37.3 ± 13.7, p-value < 0.001) or A-IMR (52.7 ± 19 vs 36.1 ± 14.1 vs 41.8 ± 16.1, p-value < 0.001). All patients presented CMD with angiography-derived IMR ≥ 25 in at least one territory with each formula. Angiography-derived IMR in LAD territory was significantly higher in patients presenting with LVEF impairment (≤ 40%) than in those with preserved ventricular global function (NH-IMRangio: 59.3 ± 18.1 vs 46.3 ± 16.0 p-value = 0.030; AngioIMR: 52.9 ± 17.8 vs 41.4 ± 14.2, p-value = 0.037; A-IMR: 59.2 ± 18.6 vs 46.3 ± 17.0, p-value = 0.035). CMD assessed with angiography-derived IMR is a common finding in TTS and it is inversely correlated with LV function. The available formulas have a substantial superimposable diagnostic performance in assessing coronary microvascular function.


Asunto(s)
Isquemia Miocárdica , Cardiomiopatía de Takotsubo , Humanos , Femenino , Anciano , Masculino , Cardiomiopatía de Takotsubo/diagnóstico por imagen , Volumen Sistólico , Estudios Retrospectivos , Microcirculación , Función Ventricular Izquierda , Valor Predictivo de las Pruebas , Vasos Coronarios/diagnóstico por imagen , Angiografía Coronaria , Resistencia Vascular , Circulación Coronaria
17.
J Clin Med ; 12(14)2023 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-37510950

RESUMEN

(1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2) Methods: Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included. Patients who had a prior PPM (n = 10), valve-in-valve procedures (n = 8) or received >1 valve during the index procedure (n = 3) were excluded. Baseline clinical, electrocardiographic (ECG), echocardiographic and multislice computed tomography (MSCT) parameters were analyzed. Pre-TAVI MSCT analysis included membranous septum (MS) length, a semi-quantitative calcification analysis of the aortic valve leaflets, left ventricular outflow tract, and mitral annulus. Furthermore, the implantation depth (ID) was measured from the final aortography. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal MS and ID cutoff values to predict new PPM requirements, respectively; (3) Results: A total of 129 TAVI patients were included (age = 81.3 ± 5.3 years; 36% female; median EuroSCORE II 3.2 [2.0, 5.4]). Fifteen patients (11.6%) required PPM after 30 days. The patients requiring new PPM at 30 days were more likely to have a lower European System for Cardiac Operative Risk Evaluation II, increased prevalence of right bundle branch block (RBBB) at baseline ECG, have a higher mitral annular calcification severity and have a shorter MS on preprocedural MSCT analysis, and have a ID, as shown on the final aortogram. From the multivariate analysis, pre-TAVI RBBB, MS length, and ID were shown to be predictors of new PPM. An MS length of <2.85 mm (AUC = 0.85, 95%CI: (0.77, 0.93)) and ID of >3.99 mm (area under the curve (AUC) = 0.79, (95% confidence interval (CI): (0.68, 0.90)) were found to be the optimal cut-offs for predicting new PPM requirements; (4) Conclusions: Membranous septum length and implantation depth were found to be independent predictors of new PPM post-TAVI with the Evolut platform. Patient-specific implantation depth could be used to mitigate the requirement for new PPM.

18.
JACC Cardiovasc Interv ; 16(23): 2884-2896, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-37877914

RESUMEN

BACKGROUND: There are no data comparing sirolimus-coated balloons (SCBs [MagicTouch, Concept Medical]) to paclitaxel-coated balloons (PCBs [SeQuent Please Neo, B. Braun]) for the treatment of de novo small vessel disease (SVD). OBJECTIVES: This study sought to compare quantitative coronary angiographic outcomes at 6 months after treatment of de novo SVD with a PCB or SCB. METHODS: This prospective, multicenter, noninferiority trial randomized 121 patients (129 SVD lesions) to treatment with an SCB or PCB, with balloon sizing determined using optical coherence tomography. The primary endpoint was noninferiority for the 6-month angiographic net lumen gain. RESULTS: Angiographic follow-up was completed in 109 (90.1%) patients in the per-protocol analysis. The mean ± SD angiographic net gains were 0.25 ± 0.40 mm with SCBs vs 0.48 ± 0.37 mm with PCBs, resulting in SCBs failing to meet the 0.30 mm criterion for noninferiority (Pnoninferiority = 0.173), with an absolute difference of -0.23 mm (95% CI: -0.37 to -0.09) secondary to a smaller late loss (0.00 ± 0.32 mm vs 0.32 ± 0.47 mm; P < 0.001) and more frequent late lumen enlargement (53.7% vs 30.0%; OR: 2.60; 95% CI: 1.22-5.67; P = 0.014) with PCBs. Binary restenosis rates were 32.8% and 12.5% following treatment with SCBs and PCBs, respectively (OR: 3.41; 95% CI: 1.36-9.44; P = 0.012). The mean angiography-derived fractional flow ratio at follow-up was 0.86 ± 0.15 following treatment with SCBs and 0.91 ± 0.09 following PCBs (P = 0.026); a fractional flow ratio ≤0.80 occurred in 13 and 5 vessels after treatment with SCBs and PCBs, respectively. CONCLUSIONS: The SCB MagicTouch failed to demonstrate noninferiority for angiographic net lumen gain at 6 months compared to the PCB SeQuent Please Neo.


Asunto(s)
Angioplastia Coronaria con Balón , Paclitaxel , Sirolimus , Enfermedades Vasculares , Humanos , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Paclitaxel/uso terapéutico , Bifenilos Policlorados , Estudios Prospectivos , Sirolimus/uso terapéutico , Resultado del Tratamiento , Enfermedades Vasculares/terapia
19.
JACC Asia ; 3(5): 689-706, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38095005

RESUMEN

Coronary physiologic assessment is performed to measure coronary pressure, flow, and resistance or their surrogates to enable the selection of appropriate management strategy and its optimization for patients with coronary artery disease. The value of physiologic assessment is supported by a large body of evidence that has led to major recommendations in clinical practice guidelines. This expert consensus document aims to convey practical and balanced recommendations and future perspectives for coronary physiologic assessment for physicians and patients in the Asia-Pacific region based on updated information in the field that including both wire- and image-based physiologic assessment. This is Part 1 of the whole consensus document, which describes the general concept of coronary physiology, as well as practical information on the clinical application of physiologic indices and novel image-based physiologic assessment.

20.
AsiaIntervention ; 8(2): 86-109, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36798834

RESUMEN

Coronary revascularisation, either percutaneous or surgical, aims to improve coronary flow and relieve myocardial ischaemia. The decision-making process in patients with coronary artery disease (CAD) remains largely based on invasive coronary angiography (ICA), even though until recently ICA could not assess the functional significance of coronary artery stenoses. Invasive wire-based approaches for physiological evaluations were developed to properly assess the ischaemic relevance of epicardial CAD. Fractional flow reserve (FFR) and later, instantaneous wave-free ratio (iFR), were shown to improve clinical outcomes in several patient subsets when used for coronary revascularisation guidance or deferral and for procedural optimisation of percutaneous coronary intervention (PCI) results. Despite accumulating evidence and positive guideline recommendations, the adoption of invasive physiology has remained quite low, mainly due to technical and economic issues as well as to operator-resistance to change. Coronary image-based computational physiology has been recently developed, with promising results in terms of accuracy and a reduction in computational time, costs, radiation exposure and risks for the patient. Lastly, the integration of intracoronary imaging and physiology allows for individualised PCI treatment, aiming at complete relief of ischaemia through optimised morpho-functional immediate procedural results. Instead of a conventional state-of-the-art review, this A to Z dictionary attempts to provide a practical guide for the application of coronary physiology in the catheterisation laboratory, exploring several methods, their pitfalls, and useful tips and tricks.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA