Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 389(15): 1380-1389, 2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37634135

RESUMEN

BACKGROUND: The role of catheter ablation in patients with symptomatic atrial fibrillation and end-stage heart failure is unknown. METHODS: We conducted a single-center, open-label trial in Germany that involved patients with symptomatic atrial fibrillation and end-stage heart failure who were referred for heart transplantation evaluation. Patients were assigned to receive catheter ablation and guideline-directed medical therapy or medical therapy alone. The primary end point was a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation. RESULTS: A total of 97 patients were assigned to the ablation group and 97 to the medical-therapy group. The trial was stopped for efficacy by the data and safety monitoring board 1 year after randomization was completed. Catheter ablation was performed in 81 of 97 patients (84%) in the ablation group and in 16 of 97 patients (16%) in the medical-therapy group. After a median follow-up of 18.0 months (interquartile range, 14.6 to 22.6), a primary end-point event had occurred in 8 patients (8%) in the ablation group and in 29 patients (30%) in the medical-therapy group (hazard ratio, 0.24; 95% confidence interval [CI], 0.11 to 0.52; P<0.001). Death from any cause occurred in 6 patients (6%) in the ablation group and in 19 patients (20%) in the medical-therapy group (hazard ratio, 0.29; 95% CI, 0.12 to 0.72). Procedure-related complications occurred in 3 patients in the ablation group and in 1 patient in the medical-therapy group. CONCLUSIONS: Among patients with atrial fibrillation and end-stage heart failure, the combination of catheter ablation and guideline-directed medical therapy was associated with a lower likelihood of a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation than medical therapy alone. (Funded by Else Kröner-Fresenius-Stiftung; CASTLE-HTx ClinicalTrials.gov number, NCT04649801.).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Humanos , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Alemania , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Corazón Auxiliar , Derivación y Consulta , Resultado del Tratamiento
2.
Nature ; 629(8012): 505, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38745094
3.
Circulation ; 148(1): 35-46, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37199171

RESUMEN

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
4.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38516791

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. METHODS AND RESULTS: Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96). CONCLUSION: The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Flujo de Trabajo , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Recurrencia
5.
Acta Oncol ; 63: 448-455, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899392

RESUMEN

BACKGROUND: Robust optimization has been suggested as an approach to reduce the irradiated volume in lung Stereotactic Body Radiation Therapy (SBRT). We performed a retrospective planning study to investigate the potential benefits over Planning Target Volume (PTV)-based planning. MATERIAL AND METHODS: Thirty-nine patients had additional plans using robust optimization with 5-mm isocenter shifts of the Gross Tumor Volume (GTV) created in addition to the PTV-based plan used for treatment. The optimization included the mid-position phase and the extreme breathing phases of the 4D-CT planning scan. The plans were compared for tumor coverage, isodose volumes, and doses to Organs At Risk (OAR). Additionally, we evaluated both plans with respect to observed tumor motion using the peak tumor motion seen on the planning scan and cone-beam CTs. RESULTS: Statistically significant reductions in irradiated isodose volumes and doses to OAR were achieved with robust optimization, while preserving tumor dose. The reductions were largest for the low-dose volumes and reductions up to 188 ccm was observed. The robust evaluation based on observed peak tumor motion showed comparable target doses between the two planning methods. Accumulated mean GTV-dose was increased by a median of 4.46 Gy and a non-significant increase of 100 Monitor Units (MU) was seen in the robust optimized plans. INTERPRETATION: The robust plans required more time to prepare, and while it might not be a feasible planning strategy for all lung SBRT patients, we suggest it might be useful for selected patients.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Órganos en Riesgo , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral , Humanos , Radiocirugia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Órganos en Riesgo/efectos de la radiación , Tomografía Computarizada Cuatridimensional/métodos , Tomografía Computarizada de Haz Cónico , Masculino , Fotones/uso terapéutico , Femenino , Anciano
6.
Arch Gynecol Obstet ; 309(1): 329-337, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37597024

RESUMEN

OBJECTIVE: International guidelines recommend vaginal pessaries as a first-choice treatment of symptomatic pelvic organ prolapse (POP). Gynecologists rarely receive systematic training or just do not take the time to communicate with their patients. We hypothesized that we could identify key deficits and limitations of counseling before or during pessary therapy from questions directed to manufacturers with the aim to improve and promote health literacy of women with POP. METHODS: We approached five manufacturers to provide anonymized inquiries related to pessary use. After exclusion of duplicates and questions about obstetric pessaries, 174 data sets from 145 patients remained. RESULTS: In 19/145 patients (13.1%), a 2nd degree, and in 94/145 (64.8%), a 3rd-4th degree of POP was identified. Four patients had additional urinary incontinence. In 32/145 (22.1%), the severity of POP could not be identified. The age of patients ranged from 27 to 98 (mean = 63.7) years. Most inquiries were related to the selected pessary models or sizes (40/174; 22.9%), self-management (20/174; 11.5%), and technical aspects such as shelf life or appropriate cleaning (26/174; 14.9%). Pain or voiding dysfunction was present in 17/174 remarks (9.7%). Lifestyle questions related to the use of pessaries during sport, menstruation, or mechanical anticonception. The cube pessary was in the focus of interest followed by the sieve bowl, urethra, ring, and Gellhorn device. The list of questions was summarized as a checklist stratified according to priorities. CONCLUSION: The checklist should help improve counseling and self-management of patients to optimize the benefit/risk ratio of conservative treatment of pelvic floor diseases.


Asunto(s)
Prolapso de Órgano Pélvico , Médicos , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Pesarios , Lista de Verificación , Promoción de la Salud , Prolapso de Órgano Pélvico/terapia , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 101(3): 610-619, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36682074

RESUMEN

BACKGROUND: Left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). OAC treatment has been proven feasible in mild-to-moderate chronic kidney disease (CKD). In contrast, the optimal antithrombotic management of AF patients with end-stage renal disease (ESRD) is unknown and LAAC has not been proven in these patients in prospective randomized clinical trials. OBJECTIVES: The objective of this study is to evaluate safety and efficacy of LAAC in patients with ESRD. METHODS: Patients undergoing LAAC were collected in a German multicenter real-world observational registry. A composite endpoint consisting of the occurrence of ischemic stroke/transient ischemic attack, systemic embolism, and/or major clinical bleeding was assessed. Patients with ESRD were compared with propensity score-matched patients without severe CKD. ESRD was defined as a glomerular filtration rate < 15 ml/min/1.73 m2 or chronic hemodialysis treatment. RESULTS: A total of 604 patients were analyzed, including 57 with ESRD and 57 propensity-matched patients. Overall, 596 endocardial and 8 epicardial LAAC procedures were performed. Frequency of major complications was 7.0% (42/604 patients) in the overall cohort, 8.8% (5/57 patients) in patients with ESRD, and 10.5% (6/57 patients) in matched controls (p = 0.75). The estimated event-free survival of the combined endpoint after 500 days was 90.7 ± 4.5% in patients with ESRD and 90.2 ± 5.5% in matched controls (p = 0.33). CONCLUSIONS: LAAC had comparable procedural safety and clinical efficacy in patients with ESRD and patients without severe CKD.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Fallo Renal Crónico , Insuficiencia Renal Crónica , Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Apéndice Atrial/diagnóstico por imagen , Estudios Prospectivos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/terapia , Diálisis Renal/efectos adversos , Sistema de Registros , Anticoagulantes/efectos adversos
8.
Europace ; 25(4): 1392-1399, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36815300

RESUMEN

AIMS: Atrial fibrillation (AF) ablation protocols using energy delivery with very high power and short duration (vHPSD) have been introduced to improve lesion formation. This study reports procedural data of vHPSD ablation in AF patients and analyses characteristics of ablation-induced left atrial (LA) scar formation from cardiac magnetic resonance imaging (MRI). METHODS AND RESULTS: Sixty consecutive patients undergoing index pulmonary vein isolation following our institutional Q4U-AF workflow were prospectively enrolled. Ablation was conducted using a contact force sensing catheter allowing for vHPSD ablation using a temperature-controlled ablation mode. Thirty patients underwent cardiac late gadolinium enhancement MRI of the LA 3 months after ablation to assess LA scar. Mean procedural duration was 66.5 ± 14.8 min. Mean ablation time was 4.7 ± 0.9 min with a mean number of 69.9 ± 14.2 applications. First-pass isolation was achieved in 51 patients (85%) for the right pulmonary veins (RPVs), in 37 patients (61.7%) for the left pulmonary veins (LPVs), and in 34 patients (56.7%) for both pulmonary veins (PVs). Magnetic resonance imaging at 3 months post-ablation demonstrated a mean scar width of 14.4 ± 2.6 mm around RPVs and 11.9 ± 1.9 mm at LPVs (P > 0.05). Complete PV encirclement was observed in 76.7% for RPVs, in 76.7% for LPVs, and in 66.7% for both PV pairs. During a mean follow-up of 4.7 ± 1.4 months, arrhythmia recurrence was observed in 3.3% of the patients. CONCLUSION: Pulmonary vein isolation following a novel vHPSD workflow resulted in short procedure duration and high acute and mid-term efficacy. Magnetic resonance imaging demonstrated durable and transmural PV lesions with homogeneous and contiguous scar formation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/patología , Medios de Contraste , Cicatriz/diagnóstico por imagen , Cicatriz/etiología , Cicatriz/patología , Flujo de Trabajo , Gadolinio , Imagen por Resonancia Magnética/métodos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Espectroscopía de Resonancia Magnética , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Venas Pulmonares/patología , Resultado del Tratamiento , Recurrencia
9.
Europace ; 25(2): 600-609, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36504238

RESUMEN

AIMS: Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients' heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. METHODS AND RESULTS: Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (Ï°>0.8; P < 0.001*). CONCLUSION: The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Niño , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad , Masculino , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirugía , Estudios Retrospectivos , Reproducibilidad de los Resultados , Ablación por Catéter/métodos , Fascículo Atrioventricular Accesorio/diagnóstico , Fascículo Atrioventricular Accesorio/cirugía , Electrocardiografía/métodos , Algoritmos
10.
Pacing Clin Electrophysiol ; 46(12): 1586-1594, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37943015

RESUMEN

Pulsed field ablation (PFA) is a promising technology for the treatment of atrial fibrillation (AF). Due to its unique tissue selectivity, PFA potentially bears superior characteristics as compared to established thermal energy sources in AF ablation procedures. Cardiovascular magnetic resonance imaging (CMR) using late gadolinium enhancement (LGE) is an established tool in the analysis of myocardial fibrosis representing atrial cardiomyopathy as well as ablation-induced atrial scar formation following catheter ablation with thermal energy. Mechanisms of atrial lesion formation differ between thermal ablation and electroporation and its impact on results of CMR imaging are not fully understood until now. In this review article, the potential of CMR imaging for PFA lesion assessment and available data are discussed. Further, additional needs to adopt imaging approaches to the cellular mechanisms of electroporation are considered.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Atrios Cardíacos/patología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/cirugía , Ablación por Catéter/métodos
11.
Pacing Clin Electrophysiol ; 46(7): 714-716, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37247251

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) results in unique lesion formation, but there is lack of in-vivo validation in terms of scar formation following atrial fibrillation (AF) ablation. OBJECTIVE: We aimed to access atrial lesion formation based on late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) following PFA for pulmonary vein (PV) and posterior wall isolation (PWI). METHODS: AF ablation was performed in 10 patients using a 31 mm pentaspline PFA catheter. After pulmonary vein isolation (PVI; n = 8 PFA-applications/ PV; n = 4 in basket and n = 4 in flower configuration), another eight applications in flower configuration were conducted for concomitant PWI. Patients underwent LGE CMR 3 months after ablation aiming for quantification of left atrial (LA) scar. RESULTS: Acute procedural success was achieved in all patients. Mean procedure duration was 62 ± 7 min. and mean LA dwell time of the PFA catheter was 13 ± 2 min. Mean post ablation total LA scar burden was 8.1 ± 2.1% and mean scar width was 12.8 ± 2.1 mm. At the posterior LA, 22.6 ± 2.2% of the anatomical segment resulted in chronic scar tissue, concentrated at the PW. Postablation CMR found no evidence for PV stenosis or collateral damage of adjacent structures. At 7 months of follow-up, 9/10 patients (90%) were free from arrhythmia recurrence. CONCLUSION: PFA for AF resulted in durable and transmural atrial scar tissue at the PVs and PW. LGE CMR found a very homogeneous and contiguous lesion pattern with no signs for collateral damage.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Cicatriz/cirugía , Medios de Contraste , Venas Pulmonares/cirugía , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Atrios Cardíacos/patología , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
12.
Pacing Clin Electrophysiol ; 46(2): 161-168, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36588339

RESUMEN

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF,) but arrhythmia recurrence occurs in a relevant number of patients. Mechanisms of late occurring arrhythmias after ablation procedures are not fully understood. We analyzed electrophysiological mechanisms of early and late arrhythmia recurrences in patients who underwent radiofrequency-based catheter ablation of AF. METHODS AND RESULTS: Consecutive patients who underwent repeat ablation procedures after initial pulmonary vein isolation (PVI) for symptomatic arrhythmia recurrence were analyzed. A total of 110 consecutive patients who underwent catheter ablation for paroxysmal (79%) or persistent AF (21%) were included. Forty-seven patients suffered from early arrhythmia recurrence (group #1: 3-24 months), 29 patients from mid-term arrhythmia recurrences (group #2: 2-5 years), and 34 patients from late arrhythmia recurrences (group #3: > 5 years). Electrical PV reconnection was found in 98% in group #1, 72% in group #2 and 56% in group #3 (p < .001). Mode of arrhythmia recurrence was organized tachycardia in 25%, 28%, and 65% of patients in groups #1, #2, and #3 (p = .001), respectively. Patients with late arrhythmia recurrence had more pronounced left atrial low voltage as compared to patients with early arrhythmia recurrence based on two published scoring system. CONCLUSION: Electrical PV reconnection was found in the majority of patients with early AF recurrence after PVI. In patients with late arrhythmia recurrences this mechanism may play an inferior role, with many patients presenting without PV reconnection, but with LA structural alterations. Thus, early and late occurring arrhythmia recurrence after catheter ablation may be the same symptom of different diseases.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Recurrencia , Atrios Cardíacos , Resultado del Tratamiento , Ablación por Catéter/métodos
13.
Pacing Clin Electrophysiol ; 46(12): 1553-1564, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37885302

RESUMEN

BACKGROUND: Targeting individual sources identified during atrial fibrillation (AF) has been used as an ablation strategy with varying results. OBJECTIVE: Aim of this study was to evaluate the relationship between regions of interest (ROIs) from CARTOFINDER (CF) mapping and atrial cardiomyopathy from late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR). METHODS: Twenty consecutive patients underwent index catheter ablation for persistent AF (PERS AF). Pre-processed LGE CMR images were merged with the results from CF mapping to visualize harboring regions for focal and rotational activities. Atrial cardiomyopathy was classified based on the four Utah stages. RESULTS: Procedural success was achieved in all patients (n = 20, 100%). LGE CMR revealed an intermediate amount of 21.41% ± 6.32% for LA fibrosis. ROIs were identified in all patients (mean no ROIs per patient n = 416.45 ± 204.57). A tendency towards a positive correlation between the total amount of atrial cardiomyopathy and the total number of ROIs per patient (regression coefficient, ß = 10.86, p = .15) was observed. The degree of fibrosis and the presence of ROIs per segment showed no consistent spatial correlation (posterior: ß = 0.36, p-value (p) = .24; anterior: ß = -0.08, p = .54; lateral: ß = 0.31, p = 39; septal: ß = -0.12; p = .66; right PVs: ß = 0.34, p = .27; left PVs: ß = 0.07, p = .79; LAA: ß = -0.91, p = .12). 12 months AF-free survival was 70% (n = 14) after ablation. CONCLUSION: The presence of ROIs from CF mapping was not directly associated with the extent and location of fibrosis. Further studies evaluating the relationship between focal and rotational activity and atrial cardiomyopathy are mandatory.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Humanos , Ablación por Catéter/métodos , Medios de Contraste , Fibrosis , Gadolinio , Atrios Cardíacos , Imagen por Resonancia Magnética/métodos
14.
Nature ; 610(7930): 34, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36195663
15.
Heart Vessels ; 38(7): 984-991, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36786857

RESUMEN

A new automated vector-based mapping algorithm (AMA) for 3-dimensional (3D) mapping has been introduced. The aim of this study was to present our experience using AMA to recognize additional catheter ablation targets in patients with ventricular arrhythmias (VA). A total of 16 patients (ICM; ischemic cardiomyopathy, n = 6; NICM; non-ischemic cardiomyopathy n = 10) suffering from VA underwent catheter ablation. Following bipolar voltage mapping, AMA was utilized to reveal zones of decelerated conduction velocity vectors (CVV) and this information was superimposed onto the 3D reconstructions and compared with the presence of scar. Mapping time was 28.1 ± 10 min for the endocardial reconstruction of the left ventricle (LV) and 17 ± 5.4 min for the epicardium (n = 6 patients). The mean area of LV low voltage was 13.9 ± 15% (endocardial) and 11.9 ± 5.7% (epicardial). Decelerating CVV zones were revealed in all patients (mean conduction velocity threshold of 39.3 ± 13%). Sustained VA have been terminated through ablation and substrate modification was performed in all patients. Correlation between the presence of CVV deceleration zones and areas of abnormal low voltage from bipolar mapping was revealed in only 37.5% of patients, but there was good correlation between scar from unipolar voltage mapping and the presence of CCV deceleration zones (94%; p = 0.008). The novel AMA may improve the understanding of individual VA substrates due to the visualization of decelerated CVV zones and their correlation with abnormal low voltage predominantly from unipolar mapping.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Cicatriz/cirugía , Ventrículos Cardíacos , Arritmias Cardíacas , Ablación por Catéter/métodos
16.
J Cardiovasc Electrophysiol ; 33(12): 2517-2527, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36104929

RESUMEN

INTRODUCTION: Approaches applying higher energy levels for shorter periods (high power short duration, HPSD) to improve lesion formation for atrial fibrillation (AF) ablation have been introduced. This single-center study aimed to compare the efficacy, safety, and lesion formation using the novel DiamondTemp (DT) catheter or an ablation index (AI)-guided HPSD ablation protocol using a force-sensing catheter with surround-flow irrigation. METHODS: One hundred thirteen consecutive patients undergoing radiofrequency-guided catheter ablation (RFCA) for AF were included. Forty-five patients treated with the DT catheter (50 W, 9 s), were compared to 68 consecutive patients undergoing AI-guided ablation (AI anterior 550; AI posterior 400) adherent to a 50 W HPSD protocol. Procedural data and AF recurrence were evaluated. RESULTS: Acute procedural success was achieved in all patients (n = 113, 100%). DT-guided AF ablation was associated with a longer mean procedure duration (99.10 ± 28.30 min vs. 78.24 ± 25.55, p < .001) and more RF applications (75.24 ± 30.76 min vs. 61.27 ± 14.06, p = .019). RF duration (792.13 ± 311.23 s vs. 1035.54 ± 287.24 s, p < .001) and fluoroscopy dose (183.81 ± 178.13 vs. 295.80 ± 247.54 yGym2 , p = .013) were lower in the DT group. AI-guided HPSD was associated with a higher AF-free survival rate without reaching statistical significance (p = .088). Especially patients with PERS AF (p = .009) as well as patients with additional atrial arrhythmia substrate (p = .002) benefited from an AI-guided ablation strategy. CONCLUSION: Temperature- and AI- controlled HPSD RFCA using 50 W was safe and effective. AI-guided HPSD ablation seems to be associated with shorter procedure durations and fewer RF applications. Particularly in advanced AF, freedom from AF-recurrence may be improved using an AI-guided HPSD approach.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Ablación por Radiofrecuencia , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Venas Pulmonares/cirugía , Temperatura , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
17.
J Cardiovasc Electrophysiol ; 33(8): 1678-1686, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35615939

RESUMEN

INTRODUCTION: Focal Impulse and Rotor Modulation (FIRM) guided catheter ablation aiming at stable rotors has been investigated as a treatment option in patients with atrial fibrillation (AF). The objective of this study was to compare the safety and efficacy of FIRM-guided ablation with second-generation cryoballoon pulmonary vein isolation (CB2-PVI) in paroxysmal AF. METHODS: Consecutive patients (n = 22, mean age 60 ± 11 years, 59.1% of males) who were treated with a stand-alone FIRM-guided ablation were included in this retrospective single-center study. Procedural data and arrhythmia-free survival at 12 months were compared with n = 86 consecutive patients (mean age 62 ± 13 years, 62.4% of males) who received de-novo CB2-PVI. RESULTS: Median procedure duration was significantly longer in the FIRM group than in the CB2-PVI group (152 [IQR 120-176] minutes vs. 122 [110-145] minutes; p = .031). One patient (1.2%) in the CB2-PVI group and five patients (22.7%) in the FIRM group had vascular access complications. Atrial tachyarrhythmias recurred in 15 patients in the FIRM group and 11 in the CB2-PVI group. Kaplan-Meier estimation of single-procedure arrhythmia-free survival at 12 months was 25% (95% confidence interval [CI] 6%-44%) in the FIRM group and 87% (95% CI 78%-96%) in the CB2-PVI group (p < .001). Repeat ablations were performed in 14/20 (70.0%) patients in the FIRM group and in 12/85 (14.1%) in the CB2-PVI group (p < .001). CONCLUSION: De novo ablation of AF using FIRM-guided AF ablation results in shorter arrhythmia-free survival after 12 months compared to CB2-PVI and a need for repeat ablation in the majority of patients to achieve stable sinus rhythm.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
18.
J Cardiovasc Electrophysiol ; 33(9): 2003-2012, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35761754

RESUMEN

INTRODUCTION: Arrhythmia recurrence after pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) is common and often linked to pulmonary vein reconnection. In patients with arrhythmia recurrences despite durable PVI the optimal ablation approach is unclear. The purpose of the present study was to analyze efficacy of extended ablation maneuvers in these patients and predictors of procedural success. METHODS: Consecutive patients with durable PVI undergoing repeat ablation procedures were prospectively enrolled. Patients underwent substrate modification with creation of linear lesions and/or mechanism-specific atrial tachycardia (AT) ablation. Three dimensional-mapping images were analyzed for the presence of left atrial (LA) low-voltage areas according to published scoring systems. RESULTS: Seventy-four patients were analyzed. Mode of recurrence after durable PVI was AF in 27 patients (36.5%) and AT in 47 patients (63.5%). Linear lesion ablation was performed in 60 patients (81.1%). Twenty-four patients (32.4%) were treated for focal AT mechanisms. Mean follow-up was 565 ± 342 days. Estimated arrhythmia-free survival after 24 months was significantly higher in patients with AT than in patients with AF as mode of recurrence after durable PVI (42.9 ± 8.2% vs. 24.7 ± 8.5%, p = .023) and in patients without compared to patients with marked LA low-voltage areas (40.5 ± 9.2% vs. 22.8 ± 8.5%, p = .041). The mode of recurrence after durable PVI was the only independent predictor of further arrhythmia recurrence after repeat ablation. CONCLUSION: Arrhythmia-free survival following repeat ablation procedures in patients with durable PVI highly depends on mode of arrhythmia recurrence and the presence of LA low-voltage areas.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
19.
J Cardiovasc Electrophysiol ; 33(12): 2606-2613, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36218022

RESUMEN

INTRODUCTION: Atrioventricular (AV)-node ablation (AVNA) is a common therapy option for rate control strategy of permanent atrial fibrillation (AF). We hypothesized that isolation of the AV nodal isolation (AVNI) is associated with a more frequent preservation of an adequate escape rhythm compared to AVNA. METHODS: This retrospective study included 20 patients with therapy-refractory AF being treated with AVNI and 40 historical AVNA-controls. In AVNI the AV-node region was mapped using a 3D mapping system. Ablation was performed around the previously mapped HIS-cloud regions isolating the atrium from the AV-node. In the AVNI group, ablation was performed with irrigated tip ablation catheter in all cases. The two approaches were compared regarding rate of escape rhythm, delta QRS, and procedural data. RESULTS: The number of patients with adequate escape rhythm in AVNI was significantly superior to AVNA immediately postoperative (90% vs. 40%, p < 0.01) and during follow-up (77% vs. 36%, p < 0.05). The median change in QRS width was 0 ms in AVNI versus +26 ms in AVNA (p < 0.01). Thirty percent new bundle branch blocks in AVNA were observed compared to 0% in AVNI (p < 0.01). In the AVNI group, fluoroscopy time and total dose area product were significantly lower (p < 0.01). CONCLUSION: The present study suggests that AV-node isolation using 3D navigation mapping system is a feasible and effective alternative to conventional AVNA. The precise application of radiofrequency lesions preserves a stable AV-junctional rhythm.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Estudios Retrospectivos , Nodo Atrioventricular/cirugía , Ablación por Catéter/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía
20.
J Cardiovasc Electrophysiol ; 33(7): 1383-1390, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35502754

RESUMEN

AIMS: Cryoballoon-guided pulmonary vein isolation (CB-PVI) for symptomatic atrial fibrillation (AF) has become an established treatment option with encouraging results in terms of safety and efficacy. Data reporting on long-term data beyond a follow-up (FU) period of 5 years is scarce. This prospective study aimed to evaluate very long-term outcome after CB-PVI for AF. METHODS: Data from consecutive patients treated with CB-PVI for symptomatic and drug refractory AF between 2005 and 2012 were analyzed. Patients with a FU of ≥9 years after index CB-PVI were included. All patients were continuously followed-up in our outpatient clinic. Arrhythmia recurrence was defined as AF or atrial tachycardia (AT) lasting >30 s beyond a 3-month blanking period. RESULTS: A total of 385 patients (71% male) were included. Mean age was 58 ± 10 years and paroxysmal AF was present in 93% of patients. Mean FU duration was 124 ± 24 months. At the end of the observational period, 73% of all patients were in stable sinus rhythm after a mean of 2 ± 0.8 ablation procedures. Patients with AF/AT recurrence were older (60 ± 8 vs. 57 ± 10 years; p = .019), had a higher CHA2 DS2 -Vasc Score (2.47 ± 1.46 vs. 1.98 ± 1.50; p = .01) and presented with a larger left atrium (LA)-diameter (43 ± 5.6 vs. 40 ± 5.1 mm; p = .002). The LA-diameter was also a significant predictor for AF/AT recurrence after CB-PVI (odds ratio: 0.939, 95% confidence interval: [0.886, 0.992], p = .03). CONCLUSIONS: CB-PVI as index procedure for AF ablation resulted in favorable long-term outcome in symptomatic AF. CB-PVI might be recommended as interventional therapy in patients with lower LA remodeling.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA