J Interv Cardiol ; 2020: 4585124, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32410916

RESUMEN

OBJECTIVES: Patent ductus arteriosus (PDA) in elderly patients is an uncommon anomaly, and the duct itself is often calcified and fragile; therefore, transcatheter closure is more difficult. The aim is to analyse periprocedural and one-year follow-up results of transcatheter closure of PDA in such patients. Methods and results. Retrospective analysis of 33 elective patients aged ≥55 years (median 63; 56-85; 29 women), in whom PDA was closed percutaneously between 2002 and 2018 in two tertiary centres. All but three patients were symptomatic, with most in NYHA II (n = 14) and III (n = 11) class; pulmonary hypertension (n = 22), arterial hypertension (n = 22), duct calcifications (n = 17), atrial fibrillation (n = 15), significant mitral regurgitation (n = 5), and decompensated renal failure (n = 2) were observed. Different devices were applied depending on PDA morphology; nitinol wire mesh occluders with symmetrical articulating discs have been the most used in recent years (n = 11). Follow-up was conducted at an outpatient clinic (28/33 patients). The procedure was successful in all patients. There was one embolisation, followed by implantation of a larger device. No major complications were noted. A small residual shunt was present in echocardiography in one patient after one year. NYHA class improved in all but two patients (with multiple comorbidities). CONCLUSIONS: Transcatheter PDA closure in elderly patients is safe and efficient with a high complete closure rate and few complications. Amplatzer duct occluder type II is an attractive device in such patients.


Asunto(s)
Cateterismo Cardíaco/métodos , Conducto Arterioso Permeable/cirugía , Complicaciones Posoperatorias , Implantación de Prótesis , Dispositivo Oclusor Septal , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Estudios Retrospectivos , Resultado del Tratamiento
2.
Cardiol Young ; 27(4): 812-815, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27869054

RESUMEN

To date, there are no reported cases of the Amplatzer Duct Occluder II: Additional Sizes' use in percutaneous closure of an aortopulmonary window. We report a case of percutaneous closure of an aortopulmonary window in a 4.5-month-old, 6 kg child. Owing to the patient's low weight, high risk of damage to the pulmonary valve, as well as the possibility of aortic and pulmonary artery obstruction, classic implants were deemed unsuitable and a decision was made to use the Amplatzer Duct Occluder II: Additional Sizes. The implant performed very well - the soft waist filled the aortopulmonary connection and both retention discs were properly shaped and pressed against vessel walls. Echocardiogram performed 12 hours after the procedure confirmed a correct occluder position. Low-profile retention discs had no impact on pulmonary valve function, despite the defect's proximity to the valve. No obstruction of the aortic or pulmonary artery lumen was noted. The Amplatzer Duct Occluder II: Additional Size implant is a safe and useful device for percutaneous closure of an aortopulmonary window in a carefully selected group of patients.


Asunto(s)
Aorta/fisiopatología , Defecto del Tabique Aortopulmonar/diagnóstico por imagen , Defecto del Tabique Aortopulmonar/cirugía , Cateterismo Cardíaco/instrumentación , Dispositivo Oclusor Septal , Angiografía por Tomografía Computarizada , Ecocardiografía , Soplos Cardíacos/etiología , Humanos , Lactante , Masculino , Anamnesis , Diseño de Prótesis , Resultado del Tratamiento
4.
J Med Case Rep ; 18(1): 70, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38378619

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation has become an attractive method of dysfunctional right ventricle outflow tract treatment. CASE PRESENTATION: We describe a unique case of a 20-year-old Caucasian male patient with a complex cyanotic heart defect, namely pulmonary atresia, with congenitally corrected transposition of the great arteries and ventricular septal defect after Rastelli-like surgery at the age of 5 years with homograft use. At the age of 20 years, the patient needed percutaneous pulmonary valve implantation owing to homograft dysfunction. Despite unusual course of the coronary arteries, balloon testing in the landing zone of the right ventricle outflow tract excluded potential coronary artery compression. Then, after presentation, a Melody valve was implanted successfully in the pulmonary valve position. The 8-year follow-up was uneventful. CONCLUSION: This is likely the first description of a percutaneous pulmonary valve implantation in such anatomy. Such a procedure is feasible; however, it requires exceptional caution owing to the anomalous coronary arteries course, which can be the reason for their compression.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Estenosis de la Válvula Pulmonar , Válvula Pulmonar , Transposición de los Grandes Vasos , Humanos , Masculino , Preescolar , Adulto Joven , Adulto , Transposición Congénitamente Corregida de las Grandes Arterias , Transposición de los Grandes Vasos/complicaciones , Transposición de los Grandes Vasos/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/complicaciones , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/cirugía , Resultado del Tratamiento
5.
Front Cardiovasc Med ; 11: 1327996, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38545348

RESUMEN

We present a case of a 22-month-old boy with a hypokinetic and thin-walled aneurysm of the left ventricle apex. The lesion was diagnosed during routine echocardiography examination in the course of MIS-C, and its occurrence due to MIS-C is plausible. Cardiac magnetic resonance imaging revealed an akinetic aneurysm of the LV apex with a full-wall ischemic scar. Aortography confirmed a normal course of coronary arteries, with adequate perfusion of essential branches and no evidence of stenosis or aneurysms. The boy underwent consultation with the heart team and was deemed eligible for surgery. The aneurysm was excised up to the margin of healthy tissues, and both the surgery and the periprocedural period were uneventful. Determining the origin of the aneurysm is challenging. The most probable etiology appears to be a congenital lesion. Another consideration is an ischemic lesion that may have resulted from impaired coronary circulation during the complicated course of MIS-C. It is possible that this disturbance resolved spontaneously before aortography was performed. Additionally, a complication of pericarditis cannot be entirely ruled out.

6.
Int J Cardiol ; 401: 131820, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38307419

RESUMEN

BACKGROUND: Post-myocardial infarction ventricular septal rupture (VSR) is a rare and severe complication of myocardial infarction. To find early mortality (<30 days) risk factors of device VSR closure and to evaluate its medium-term outcome. METHODS: Multicenter retrospective analysis on all 46 consecutive patients with percutaneous (n = 43) or hybrid (n = 3) VSR closure in 2000-2020 with various nitinol wire mesh occluders. Medical records, hemodynamic data, procedure results, short- and mid-term follow-up were analyzed (4.8 ± 3.7 years, range: 0.1-15, available in 61.7% of patients). Of the patients, 34.8% underwent VSR closure in acute phase (<21 days after VSR occurrence), 17.4% underwent device closure due to significant residual shunt after previous VSR surgery. RESULTS: Success rate was 78.3%. More than moderate residual shunt, major complications, and early surgical reintervention affected 18.9%, 15.2% (including 2 intra-procedural deaths), and 21.7% of patients, respectively. Early mortality was 26.1% (13.9% in successful vs. 70% in unsuccessful closure; p < 0.001). Older age, need for intra-aortic balloon counterpulsation, severe complications, and procedural failure were identified as risk factors for early mortality. Among patients who survived the early period, the 5-year survival rate was 57.1%. NYHA class improved in 88.2% patients at the latest follow-up. CONCLUSIONS: Procedure of VSR device closure demonstrates an acceptable technical success rate; however, the incidence of severe complications and early mortality is notably high. Older patients in poor hemodynamic condition and those with unsuccessful occluder deployment are particularly at a higher risk of a fatal outcome. The prognosis after early survival is promising.


Asunto(s)
Infarto del Miocardio , Rotura Septal Ventricular , Humanos , Rotura Septal Ventricular/diagnóstico , Rotura Septal Ventricular/etiología , Rotura Septal Ventricular/cirugía , Estudios Retrospectivos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/cirugía , Infarto del Miocardio/complicaciones , Factores de Riesgo , Pronóstico , Resultado del Tratamiento
7.
Med Sci Monit ; 19: 618-24, 2013 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-23892911

RESUMEN

BACKGROUND: The complexity of ventricular septal defects in early infancy led to development of new mini-invasive techniques based on collaboration of cardiac surgeons with interventional cardiologists, called hybrid procedures. Hybrid therapies aim to combine the advantages of surgical and interventional techniques in an effort to reduce the invasiveness. The aim of this study was to present our approach with mVSD patients and initial results in the development of a mini-invasive hybrid procedure in the Gdansk Hybrid Heartlink Programme (GHHP) at the Department of Pediatric Cardiac Surgery, Pomeranian Centre of Traumatology in Gdansk, Poland. MATERIAL AND METHODS: The group of 11 children with mVSDs was enrolled in GHHP and 6 were finally qualified to hybrid trans-ventricular mVSD device closure. Mean age at time of hybrid procedure was 8.22 months (range: from 2.7 to 17.8 months, SD=5.1) and mean body weight was 6.3 kg (range: from 3.4 to 7.5 kg, SD=1.5). RESULTS: The implants of choice were Amplatzer VSD Occluder and Amplatzer Duct Occluder II (AGA Med. Corp, USA). The position of the implants was checked carefully before releasing the device with both transesophageal echocardiography and epicardial echocardiography. All patients survived and their general condition improved. No complications occurred. The closure of mVSD was complete in all children. CONCLUSIONS: Hybrid procedures of periventricular muscular VSD closure appear feasible and effective for patients with septal defects with morphology unsuitable for classic surgical or interventional procedures. The modern strategy of joint cardiac surgical and interventional techniques provides the benefits of close cooperation between cardiac surgeon and interventional cardiologist for selected patients in difficult clinical settings.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Defectos del Tabique Interventricular/cirugía , Miocardio/patología , Ecocardiografía Transesofágica , Femenino , Defectos del Tabique Interventricular/diagnóstico por imagen , Humanos , Lactante , Masculino , Polonia
8.
Kardiol Pol ; 81(3): 259-264, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36594530

RESUMEN

BACKGROUND: Transcatheter closure of atrial septal defect (ASD) has become the treatment of choice for most patients. About 5% of them suffer from transient headache episodes (THE) after the procedure, whose etiology is unclear. AIMS: To evaluate risk factors for THE occurrence after transcatheter closure of ASD in the pediatric population. METHODS: Eight hundred and forty patients, after transcatheter ASD closure with nitinol devices, from a single center, were included in retrospective analysis. THE was defined as occurring up to 24 hours after the procedure. A logistic regression model including age, weight, ASD diameter, device size, presence of nitinol coating on the device, fluoroscopy time, application of balloon calibration, device oversizing, and residual shunt after 24 hours was created to evaluate risk factors for THE occurrence. RESULTS: There were 40 patients with THE (4.8%), 70% female and 30% male. The median age was 13 (7.35-16) years. In patients with headache, balloon calibration (BC) was performed more frequently (82.5% vs. 43.3%; P <0.001). The balloon waist median (interquartile range [IQR]), 19 (16-22) mm vs. 15 mm (12-18) mm (P <0.001), and device size median (IQR), 18 (13.5-22) mm vs. 14 (11-17) mm (P <0.001) were larger, and residual shunt after 24 hours (12.5% vs. 4.9%; P = 0.03) and a year (7.5 vs. 1.0%; P <0.001) were more frequent. ASD size and the prevalence of double/multiple ASD were similar in both groups. Age, BC application, no nickel release protection, duration of fluoroscopy, and device oversizing were predictors of THE (P <0.001). CONCLUSIONS: BC during percutaneous ASD closure and the lack of a protective layer against nickel release on the device are risk factors for headache occurrence in the early postprocedural period.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Humanos , Niño , Masculino , Femenino , Adolescente , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios Retrospectivos , Defectos del Tabique Interatrial/cirugía , Defectos del Tabique Interatrial/etiología , Cefalea/etiología , Resultado del Tratamiento , Ecocardiografía Transesofágica , Dispositivo Oclusor Septal/efectos adversos
9.
Postepy Kardiol Interwencyjnej ; 18(2): 154-161, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36051839

RESUMEN

Introduction: Balloon aortic valvuloplasty (BAV) is a common treatment method of aortic valve (AV) stenosis in neonates. Long-term BAV effects are suboptimal, and their predictors are not well acknowledged. Aim: To identify predictors of suboptimal short- and long-term BAV results. Material and methods: The study group comprised forty-three neonates (8 females; weight 3.34 ±0.56 kg) who underwent BAV between 1998 and 2021. Seventeen patients (39.53%) had critical AV stenosis. AV was bicuspid in 22 patients, tricuspid in 12, unicuspid in 2, and undefined in 7 patients. The mean balloon/annulus ratio was 0.9 ±0.07. Catheterization, clinical, and follow-up data were analysed. Results: The peak-to-peak gradient decreased from 67.5 ±26.3 to 21.3 ±12.6 mm Hg. Twenty-eight patients (65.1%) had adequate early outcome. Aortic regurgitation (AR) occurred in 13 (30.2%) patients. No predictors of inadequate early outcome were found. Twenty-year survival was 90.7%. Eleven (35.5%) patients underwent reintervention at a median of 12 (1-215) months; BAV in 5 patients, surgical valvuloplasty in 2, Ross operation in 2, AV replacement in 1, and Norwood operation in 1 patient. Fifteen-year freedom from reintervention (FFR) was 48%. Adequate early outcome resulted in higher FFR (71% vs. 22%), and so did no significant AR (60% vs. 30%). Conclusions: BAV provides satisfying early results. AR remains a significant aftermath of BAV. Risk factors and procedural techniques improving the outcome of BAV are unclear. Further research is needed to improve FFR.

10.
J Cardiovasc Dev Dis ; 9(12)2022 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-36547454

RESUMEN

Patients with pulmonary arterial hypertension (PAH) become candidates for lung or lung and heart transplantation when the maximum specific therapy is no longer effective. The most difficult challenge is choosing one of the above options in the event of symptoms of right ventricular failure. Here, we present two female patients with PAH: (1) a 21-year-old patient with Eisenmenger syndrome, caused by a congenital defect-patent ductus arteriosus (PDA); and (2) a 39-year-old patient with idiopathic PAH and coexistent PDA. Their common denominator is PDA and the hybrid surgery performed: double lung transplantation with simultaneous PDA closure. The operation was performed after pharmacological bridging (conditioning) to transplantation that lasted for 33 and 70 days, respectively. In both cases, PDA closure effectiveness was 100%. Both patients survived the operation (100%); however, patient no. 1 died on the 2nd postoperative day due to multi-organ failure; while patient no. 2 was discharged home in full health. The authors did not find a similar description of the operation in the available literature and PubMed database. Hence, we propose this new treatment method for its effectiveness and applicability proven in our practice.

11.
J Arrhythm ; 37(4): 1101-1104, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34386138

RESUMEN

We report a 15-year-old male with hypoplastic left heart syndrome (HLHS) after Fontan operation with recurrent, drug-resistant atrial tachycardia. With the use of electro-anatomical mapping system (EnSite) an atrial flutter (AFl) with reentry activation around the tricuspid valve was diagnosed. Successful radiofrequency catheter ablation (RFCA) was performed.

12.
Kardiol Pol ; 79(3): 287-293, 2021 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-33599452

RESUMEN

BACKGROUND: Transcatheter patent ductus arteriosus (PDA) closure has become the first­choice method of treatment in the majority of patients. However, device selection poses a challenge. AIMS: This study aimed to analyze periprocedural and 1­year outcomes of PDA transcatheter closure performed with different devices throughout a 25­year time period in a single center. METHODS: All 1036 patients who underwent transcatheter PDA closure between 1993 and 2020 were included in retrospective analysis. Various devices were used: the Rashkind device (RD; n = 25), coils (n = 469), nitinol duct occluders type I (DO I; n = 300), type II (n = 32), type II additional sizes (ADO II AS; n = 209), as well as off­label devices: vascular plugs and atrial septal and muscular ventricular septal defect occluders (n = 17). Data on 24­hour and 1­year follow­up were available for 100% and 78.9% of the study patients, respectively. RESULTS: The procedure was successful in 98.6% of the study patients, with a major complication rate of 0.2%. Complete PDA closure after a year was observed in 81.8% of the patients treated with RD, 93.7% of those with coils, and 100% of those with duct occluders. There were no differences between Amplatzer DO I (n = 159) and its DO I copies manufactured in China (n = 141) with regard to success, efficacy, and complication rates. Recently, ADO II AS has replaced coils and become the preferred device to close small­to­moderate PDA. CONCLUSIONS: Transcatheter PDA closure with all types of nitinol duct occluders is safe and effective, with no residual shunting at 1­year follow­up. Due to higher efficacy, ADO II AS has replaced coils in the treatment of smaller PDA.


Asunto(s)
Conducto Arterioso Permeable , Dispositivo Oclusor Septal , Cateterismo Cardíaco , China , Conducto Arterioso Permeable/cirugía , Humanos , Lactante , Estudios Retrospectivos , Resultado del Tratamiento
13.
Kardiol Pol ; 67(12): 1371-3, 2009 Dec.
Artículo en Polaco | MEDLINE | ID: mdl-20054768

RESUMEN

We present 2 cases (4 and 17-year-old children) with aorta-vena azygos fistulae. In the fist child spontaneous closure was confirmed by clinical symptoms and aortography, in the second (with significant left-right shunt) successful closure with 10 x 8 mm Amplatzer Duct Occluder was obtained. These case reports show that the strategy of treatment of aorto-venous fistulae must be individualised.


Asunto(s)
Aorta/anomalías , Fístula Arteriovenosa/terapia , Vena Ácigos/anomalías , Adolescente , Aortografía , Fístula Arteriovenosa/diagnóstico por imagen , Vena Ácigos/diagnóstico por imagen , Cateterismo Cardíaco , Procedimientos Quirúrgicos Cardiovasculares , Humanos , Lactante , Masculino , Medicina de Precisión/métodos , Dispositivo Oclusor Septal
14.
Kardiol Pol ; 67(7): 762-4, 2009 Jul.
Artículo en Polaco | MEDLINE | ID: mdl-19649998

RESUMEN

Paravalvular leak (PVL) is a complication observed in patients after prosthetic valve replacement. The incidence of PVL is estimated as 2-3%. The cause of PVL may be paravalvular infection, suture continuity disruption, damage of tissues around the annulus or limitation of disc mobility by thrombus or vegetation. The preferable method of treatment of PVL is surgery. Recently, percutaneous closure of PVL became an alternative method. We present a case of successfully completed percutaneous closure of PVL with the use of Amplatzer occluder device in a patient with mitral PVL.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Anciano , Insuficiencia de la Válvula Aórtica/cirugía , Femenino , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Ultrasonografía
15.
Kardiol Pol ; 67(3): 348-52, 2009 Mar.
Artículo en Polaco | MEDLINE | ID: mdl-19378246

RESUMEN

Transcatheter implantation of pulmonary valve became a big step forward in the field of interventional cardiology. It is especially important in the patients with defects of the right ventricular outlet tract, because they were usually candidates for multiple surgical operations. We present first transcatheter replacement of pulmonary valve in 23-years-old man. The 'Melody' valve was implanted successfully. There were no complications and the patient was discharged in good condition.


Asunto(s)
Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Pulmonar/cirugía , Obstrucción del Flujo Ventricular Externo/terapia , Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/complicaciones , Defectos del Tabique Interventricular/cirugía , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Atención Perioperativa/métodos , Resultado del Tratamiento , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/terapia , Adulto Joven
16.
Kardiol Pol ; 67(10): 1155-61, 2009 Oct.
Artículo en Polaco | MEDLINE | ID: mdl-20017086

RESUMEN

AIM: To assess the early results of the pulmonary artery valve transcatheter implantation (PAVTI) in pts included into POL-PAVTI registry. Detailed medical and economic analyses were performed. METHODS: Pulmonary artery valve implantation was performed in 14 pts (9 men), aged 16-31 (mean 24.6 +/- 4.8) years, with pulmonary homograft dysfunction after total repair of tetralogy of Fallot (4 pts), pulmonary atresia (2 pts), pulmonary stenosis (1 pt), common arterial trunk type I (1 pt), Ross procedure (3 pts) and TGA - Rastelli operation (3 pts). Eleven pts underwent in the past 2-5 surgical or/and catheter interventions. Indication for PAVTI was based on clinical evaluation and echocardiographic studies. Assessment of morphological and functional features of the right ventricle (RV) and homograft with the use of cardiac magnetic resonance (CMR) was performed in 10 cases. Pulmonary stenosis (max. pulmonary gradient 32-119, mean 72 +/- 28 mmHg) was observed in 13 pts and/or significant pulmonary regurgitation in 10 pts. The procedure was performed in general anesthesia. The deployment of a valved stent in the pulmonary valve position was preceded by a metal stent implantation. Results were evaluated by echocardiography two days after the procedure and one month later. Four patients were evaluated 6 months after procedure. RESULTS: Time of the procedure varied 60-190 (mean 127 +/- 35) min, time of fluoroscopy ranged 12-31 (mean 21 +/- 11) min. PAVTI was successfully performed in all pts without serious complications. Patients were discharged from the hospital 48-293 (mean 120 +/- 71) h after procedure. Significant reduction of pulmonary gradient after the procedure assessed by echocardiography was observed on the second day (20-60, mean 38 +/- 12 mmHg, p < 0.0001) and one month (19-52, mean 34 +/- 9 mmHg, p < 0.0001). Mild pulmonary regurgitation was observed in 2 pts. In 5 pts evaluated 6 months after procedure haemodynamic parameters were unchanged; no late complications were observed. Average cost of the procedure including a price of the valve (82 000 PLN) was 98 000 PLN. CONCLUSIONS: Pulmonary artery valve transvascular implantation is an effective and safe method of non-surgical treatment for patients with homograft dysfunction. Cost-effectiveness is approvable.


Asunto(s)
Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Arteria Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adolescente , Adulto , Implantación de Prótesis Vascular/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Ecocardiografía Transesofágica , Estudios de Seguimiento , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Masculino , Polonia , Arteria Pulmonar/anomalías , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/cirugía , Adulto Joven
19.
J Cardiol ; 74(4): 381-387, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31023567

RESUMEN

BACKGROUND: We aimed to evaluate medium- and long-term outcomes of transcatheter closure (TC) of ruptured sinus of Valsalva aneurysm (RSVA), which is a rare and mostly congenital heart disease. METHODS: Retrospective analysis included 23 patients (14 males) aged 15-79 years (y; 39.9±18.5) selected for TC of RSVA between 2007 and 2017 in two tertiary centers in Poland and Ukraine. Fifteen patients were in New York Heart Association (NYHA) class III or IV before TC; 5 patients had acquired RSVA after previous cardiac surgery. We applied 22 duct, 3 muscular, and 1 atrial septal Amplatzer or Amplatzer-like occluders by the anterograde venous approach after arterio-venous loop creation in all but 1 patient. Mean follow-up conducted in outpatient clinic was 5.5±3.5 (1-11)y. RESULTS: The procedure was successful in 19/23 patients (82.6%). Four procedures were abandoned and the device percutaneously retrieved due to coronary artery compression (1 patient), transient increase of aortic regurgitation (AR; 1 patients) or embolization (2 patients). New onset of significant AR was noted in one of the latter patients after device removal. NYHA class improved in all treated patients but 2, in whom it remained stable (p<0.05), with 10 patients in class I. Three patients needed percutaneous re-intervention during follow-up because of significant residual shunt in 1 and late recurrent RSVA in 2 patients. The follow-up of the remaining patients was uneventful. Neither erosion, embolization, new AR, nor death were observed. CONCLUSIONS: The percutaneous closure of RSVA is a safe and effective method of treatment with good clinical outcome. However, although not described previously, recurrent shunts after TC of RSVA are possible and can be treated successfully with another transcatheter intervention.


Asunto(s)
Rotura de la Aorta/cirugía , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Seno Aórtico/cirugía , Adolescente , Adulto , Anciano , Cateterismo Cardíaco/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polonia/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Ucrania/epidemiología , Adulto Joven
SELECCIÓN DE REFERENCIAS