RESUMEN
BACKGROUND: Attachment theory represents a reference model for understanding better how pre-existing personality factors can influence the coping with some chronic conditions. The onset of a chronic disease can represent a "threat" to the relationships between the subject and parental figures according to the type of bond that already exists. The aim of our study was to explore attachment styles in a sample of hemodialysis patients, hypothesizing that a secure attachment bond can constitute a protective factor for the quality of life and mental health in this type of patients. DESIGN: We used a cross-sectional design. METHODS: Fifty hemodialysis patients were given the following tests: Attachment Style Questionnaire (ASQ) to assess attachment styles, Parental Bonding Instrument (PBI) to assess parental bonding, Short Form Health Survey-36 (SF-36) for perceived quality of life and Middlesex Hospital Questionnaire (MHQ) to detect key psychological symptoms and relevant traits. RESULTS: The results showed that secure attachment style correlated with good general health (r = 0.339; p < 0.05), good mental health (r = 0.547; p < 0.001) and mental component scale (r = 0.373; p < 0.05) of SF-36. Secure attachment was also significantly associated with mental health (B = 1.104; p = .002) of the SF-36. CONCLUSIONS: The results confirmed the positive role of a secure attachment style for adequate psychological health. Early identification of patients with dysfunctional attachment styles will make it possible to offer them targeted interventions to improve their ability to accept, adapt and manage the disease and to maintain adequate psychological well-being.
Asunto(s)
Trastornos Mentales , Salud Mental , Humanos , Estudios Transversales , Calidad de Vida , Padres , Enfermedad Crónica , Apego a ObjetosRESUMEN
A 74-years-old patient, without comorbidity, underwent malleable penile prosthesis (MPP) implantation in 2007. In 2015, after a perineal trauma, he experienced stress urinary incontinence, medial extrusion of the left prosthetic cylinder and an urethrocavernous fistula. The cylinder was removed and an artificial urinary sphincter (AUS) implanted, together with a three-component inflatable penile prosthesis (IPP). The left corpus cavernosum (CC) was significantly shorter than the right one due to fibrosis. After 8 months, partial lateral extrusion of the right prosthetic cylinder prompted a replacement with a shorter extensor. Six months after, a new diastasis of the ruptured area occurred due to a further CC shortening. The extensor was removed and the cylinder shortened, with a dermal graft applied to the area. Long-term patient satisfaction was high.