Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Stroke ; 53(11): 3429-3438, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35862225

RESUMEN

BACKGROUND: Whether bridging therapy (intravenous thrombolysis [IVT] followed by mechanical thrombectomy) is superior to IVT alone in minor stroke with large vessel occlusion is unknown. Perfusion imaging may identify subsets of large vessel occlusion-related minor stroke patients with distinct response to bridging therapy. METHODS: We conducted a multicenter international observational study of consecutive IVT-treated patients with minor stroke (National Institutes of Health Stroke Scale score ≤5) who had an anterior circulation large vessel occlusion and perfusion imaging performed before IVT, with a subset undergoing immediate thrombectomy. Propensity score with inverse probability of treatment weighting was used to account for baseline between-groups differences. The primary outcome was 3-month modified Rankin Scale score 0 to 1. We searched for an interaction between treatment group and mismatch volume (critical hypoperfusion-core volume). RESULTS: Overall, 569 patients were included (172 and 397 in the bridging therapy and IVT groups, respectively). After propensity-score weighting, the distribution of baseline variables was similar across the 2 groups. In the entire population, bridging was associated with lower odds of achieving modified Rankin Scale score 0 to 1: odds ratio, 0.73 [95% CI, 0.55-0.96]; P=0.03. However, mismatch volume modified the effect of bridging on clinical outcome (Pinteraction=0.04 for continuous mismatch volume); bridging was associated with worse outcome in patients with, but not in those without, mismatch volume <40 mL (odds ratio, [95% CI] for modified Rankin Scale score 0-1: 0.48 [0.33-0.71] versus 1.14 [0.76-1.71], respectively). Bridging was associated with higher incidence of symptomatic intracranial hemorrhage in the entire population, but this effect was present in the small mismatch subset only (Pinteraction=0.002). CONCLUSIONS: In our population of large vessel occlusion-related minor stroke patients, bridging therapy was associated with lower rates of good outcome as compared with IVT alone. However, mismatch volume was a strong modifier of the effect of bridging therapy over IVT alone, notably with worse outcome with bridging therapy in patients with mismatch volume ≤40 mL. Randomized trials should consider adding perfusion imaging for patient selection.


Asunto(s)
Arteriopatías Oclusivas , Isquemia Encefálica , Accidente Cerebrovascular , Humanos , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/terapia , Isquemia Encefálica/complicaciones , Resultado del Tratamiento , Accidente Cerebrovascular/terapia , Accidente Cerebrovascular/tratamiento farmacológico , Trombectomía/métodos , Imagen de Perfusión , Arteriopatías Oclusivas/complicaciones , Terapia Trombolítica/métodos , Fibrinolíticos/uso terapéutico
2.
Stroke ; 52(12): e769-e772, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34702062

RESUMEN

BACKGROUND AND PURPOSE: Determining the mechanism of large vessel occlusion related acute ischemic stroke is of major importance to initiate a tailored secondary prevention strategy. We investigated using the atherosclerosis, small vessel disease, cardiac source, other cause, dissection (ASCOD) classification the distribution of the causes of large vessel occlusion related acute ischemic stroke treated by mechanical thrombectomy. METHODS: This was a predefined substudy of the FRAME (French Acute Multimodal Imaging to Select Patient for Mechanical Thrombectomy). Each patient underwent a systematic etiological workup including brain and vascular imaging, electrocardiogram monitoring lasting at least 24 hours and routine blood tests. Stroke mechanisms were systematically evaluated using the atherosclerosis, small vessel disease, cardiac source, other cause, dissection grading system at 3 months. We defined single potential cause by one cause graded 1 in a single domain, possible cause as a cause graded 1 or 2 regardless of overlap, and no identified cause without grade 1 nor 2 causes. RESULTS: A total of 215 patients (mean age 70±14; 50% male) were included. A single potential cause was identified in 148 (69%). Cardio-embolism (53%) was the most frequent, followed by atherosclerosis (9%), dissection (5%) and other causes (1%). Atrial fibrillation accounted for 88% of C1. Overlap between grade 1 causes was uncommon (3%). Possible causes were identified in 168 patients (83%) and 16 (7%) had no cause identified after the initial evaluation. CONCLUSIONS: Cardio-embolism, especially atrial fibrillation, was the major cause of large vessel occlusion related acute ischemic stroke. This finding emphasizes the yield of paroxysmal atrial fibrillation detection in those patients. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03045146.


Asunto(s)
Disección Aórtica/complicaciones , Aterosclerosis/complicaciones , Fibrilación Atrial/complicaciones , Embolia/complicaciones , Accidente Cerebrovascular Isquémico/etiología , Anciano , Trastornos Cerebrovasculares/complicaciones , Femenino , Humanos , Accidente Cerebrovascular Isquémico/cirugía , Masculino , Persona de Mediana Edad , Fenotipo , Trombectomía
3.
Int J Stroke ; 18(1): 102-108, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35361018

RESUMEN

BACKGROUND AND AIMS: Cerebral small vessel disease (CSVD) is the main cause of intracerebral hemorrhage (ICH) in older individuals but has not been systematically studied in younger people. We aimed to evaluate the prevalence and characteristics of CSVD in young adults with symptomatic ICH. METHODS: We conducted a cohort study of consecutive adults aged 18-50 years with non-traumatic ICH. All patients were evaluated with brain and vascular imaging. Using validated imaging markers (cerebral microbleeds (CMBs), white matter hyperintensities and/or lacunes), patients were categorized as having CSVD-related ICH or non-CSVD-related ICH. Factors associated with CSVD were evaluated using multivariable analyses. CSVD subtypes were characterized using pre-specified criteria. RESULTS: Of 146 young adults with ICH (mean age = 37.7), CSVD was present in 41 patients (28.1%; 95% confidence interval (CI) = 21.0-36.1). In multivariable analysis, older age, male sex, and hypertension were independently associated with the presence of CSVD. Deep perforator arteriopathy (48.8%) and mixed CSVD (31.7%) were the most common CSVD subtypes. CONCLUSION: Our results suggest that CSVD is a frequent cause of ICH in young adults and provide new insights into the characterization of the disease. These findings may have important implications since the treatment and management differ from other causes of ICH.


Asunto(s)
Enfermedades de los Pequeños Vasos Cerebrales , Accidente Cerebrovascular , Humanos , Masculino , Adulto Joven , Anciano , Adulto , Estudios de Cohortes , Prevalencia , Accidente Cerebrovascular/complicaciones , Imagen por Resonancia Magnética/métodos , Hemorragia Cerebral/complicaciones , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/epidemiología , Enfermedades de los Pequeños Vasos Cerebrales/complicaciones , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Enfermedades de los Pequeños Vasos Cerebrales/epidemiología
4.
J Neuroimaging ; 32(5): 894-901, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35811446

RESUMEN

BACKGROUND AND PURPOSE: Carotid web (CaW) is a cause of recurrent ischemic stroke that remains underdiagnosed using Duplex ultrasound (DUS). Improved methods and description of its ultrasound's features could allow better detection of CaW. Ultrasound microflow imaging (MFI) is a blood flow imaging technique sensitive to slow flow that could increase CaW detection. This study aimed to describe ultrasound features of CaW using B-mode imaging and MFI. METHODS: In a retrospective monocentric study, patients with CaW on CT angiography who underwent DUS examination of carotid arteries were included. DUS was performed by two nonblinded experienced neurosonologists. The specificity of CaW ultrasound features was evaluated using a group of patients with carotid atherosclerotic plaque (AP). RESULTS: Twenty-four patients with CaW were included. Mean age (standard deviation) was 48 years (11). Seventeen (71%) were females. Fifteen (63%) CaWs were symptomatic. MFI was available for 22 patients. B-mode imaging demonstrated the characteristic CaW appearance in 19/24 (79%) patients as a protruding triangular iso-hypoechoic lesion on longitudinal view. CaW were detected on axial view in only 9/24 (38%) patients. MFI displayed slow blood flow above CaW during systole and allowed it delineation, appearing as a thin triangular endoluminal defect in 18/22 (82%) cases. Based on MFI and B-mode, 21/22 (95%) CaWs were visible, including three CaWs only with MFI. These ultrasound features were not found among 24 patients with AP. CONCLUSION: We report the ultrasound features from a series of 24 CaW. The use of MFI in addition to B-mode imaging improved the detection rate of CaW.


Asunto(s)
Estenosis Carotídea , Placa Aterosclerótica , Arterias Carótidas/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Niño , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Estudios Retrospectivos , Ultrasonografía , Ultrasonografía Doppler Dúplex
5.
Forensic Sci Int ; 247: 126-9, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25575014

RESUMEN

Hexagon Obti immunological blood test and flocked swab are widely used in forensic laboratories. Nevertheless, up to now, no compatibility tests have been published between sampling with the ethylene oxide treated flocked swab and the Hexagon Obti blood detection strip. In this study, we investigated this compatibility. Our work shows that sampling with ethylene oxide treated flocked swab reduces by a factor of at least 100 the detection threshold of blood using the Hexagon Obti immunological test.


Asunto(s)
Recolección de Muestras de Sangre/instrumentación , Manchas de Sangre , Óxido de Etileno , Nylons , Tiras Reactivas , Medicina Legal/instrumentación , Humanos , Pruebas Inmunológicas/instrumentación , Masculino , Antígeno Prostático Específico/aislamiento & purificación , Espectrometría Raman
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA