RESUMEN
BACKGROUND: The multicenter, international, randomized, blinded, sham-controlled RADIANCE-HTN SOLO trial (A Study of the ReCor Medical Paradise System in Clinical Hypertension) demonstrated a 6.3 mm Hg greater reduction in daytime ambulatory systolic blood pressure (BP) at 2 months by endovascular ultrasound renal denervation (RDN) compared with a sham procedure among patients not treated with antihypertensive medications. We report 6-month results after the addition of a recommended standardized stepped-care antihypertensive treatment to the randomized endovascular procedure under continued blinding to initial treatment. METHODS: Patients with a daytime ambulatory BP ≥135/85 mm Hg and <170/105 mm Hg after a 4-week discontinuation of up to 2 antihypertensive medications, and a suitable renal artery anatomy, were randomized to RDN (n=74) or sham (n=72). Patients were to remain off antihypertensive medications throughout the first 2 months of follow-up unless safety BP criteria were exceeded. Between 2 and 5 months, if monthly measured home BP was ≥135/85 mm Hg, a standardized stepped-care antihypertensive treatment was recommended consisting of the sequential addition of amlodipine (5 mg/d), a standard dose of an angiotensin-converting enzyme inhibitor/angiotensin receptor blocker, and hydrochlorothiazide (12.5 mg/d), followed by the sequential uptitration of hydrochlorothiazide (25 mg/d) and amlodipine (10 mg/d). Outcomes included the 6-month (1) change in daytime ambulatory systolic BP adjusted for medications and baseline systolic BP, (2) medication burden, and (3) safety. RESULTS: A total of 69/74 RDN patients and 71/72 sham patients completed the 6-month ambulatory BP measurement. At 6 months, 65.2% of patients in the RDN group were treated with the standardized stepped-care antihypertensive treatment versus 84.5% in the sham group (P=0.008), and the average number of antihypertensive medications and defined daily dose were less in the RDN group than in the sham group (0.9±0.9 versus 1.3±0.9, P=0.010 and 1.4±1.5 versus 2.0±1.8, P=0.018; respectively). Despite less intensive standardized stepped-care antihypertensive treatment, RDN reduced daytime ambulatory systolic BP to a greater extent than sham (-18.1±12.2 versus -15.6±13.2 mm Hg, respectively; difference adjusted for baseline BP and number of medications: -4.3 mm Hg, 95% confidence interval, -7.9 to -0.6, P=0.024). There were no major adverse events in either group through 6 months. CONCLUSIONS: The BP-lowering effect of endovascular ultrasound RDN was maintained at 6 months with less prescribed antihypertensive medications compared with a sham control. CLINICAL TRIAL REGISTRATION: URL: https://www. CLINICALTRIALS: gov. Unique identifier: NCT02649426.
RESUMEN
BACKGROUND: Ambulatory ECG monitoring is typically achieved using portable devices with limited number of surface leads, autonomy, and length of recording. Smart garments with multiple conductive textile electrodes provide great promise to perform continuous and comfortable ECG monitoring. METHODS: We evaluated the ECG signal quality measured on healthy subjects with a smart 12-lead ECG acquisition T-shirt or a 12-lead Holter recording. ECG signals were recorded during 3 min with both techniques in three resting positions (supine, seated, standing) and while walking. Three readers independently assessed ECG patterns and evaluated the denoising of the isoelectric line, the distinction of p waves, R peaks and RR intervals, and the possible appreciation of cardiac rhythm in at least 3 leads. RESULTS: Thirty healthy subjects (70% males, 29.5 ± 7.8 years) were enrolled in the study. For all three resting conditions, cardiac rhythm was appreciated in 100% of recordings with distinction of p waves, R peaks, and isoelectric line in >97% of recordings. Appreciation of cardiac rhythm was lower in the walking conditions with both techniques (53.3% vs. 46.7%, Holter vs. smart T-shirt, p = .60) mainly due to difficulties to distinguish p waves. These results were consistent across both genders. All ECG parameters (heart rate, PR, QRS and QTC intervals) were comparable between both techniques. No skin irritation was seen with the textile electrodes. CONCLUSIONS: A smart T-shirt with 13 textiles electrodes allows short-duration 12-lead ECG acquisition with quality levels comparable to Holter recordings. The novel device should now be evaluated for long-term non-invasive ECG monitoring.
Asunto(s)
Vestuario , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Procesamiento de Señales Asistido por Computador/instrumentación , Adulto , Femenino , Humanos , Masculino , Estudios Prospectivos , Valores de Referencia , Reproducibilidad de los ResultadosRESUMEN
Chest pain is one of the major causes for admission in the Emergency Room in most countries and one of the principal reasons for urgent consultation with a cardiologist or a general practitioner. After clinical examination and initial biological measurements, substantial patients require further explorations. CT scan allows the search for pulmonary embolism in the early stage of pulmonary arteries iodine contrast exploration. During the same exam at the systemic arterial phase, the search for aortic dissection or coronary artery disease is possible while exploring the later contrast in the aortic artery. This triple rule-out exam allows correct diagnosis in case of acute chest pain with suspected pulmonary embolism, aortic dissection and other acute aortic syndromes or acute coronary syndrome. But X-rays are substantially increased as well as iodine contrast agent quantity while exam quality is globally decreased. Artificial intelligence may play an important role in the development of this protocol.
RESUMEN
BACKGROUND: The long-term cardiovascular consequences of microgravity on large arteries are a threat for long-term space missions. We hypothesized that changes in arterial properties differ according to the arterial territory (upper or lower body), and arterial structure (elastic vs. muscular arteries), in response to 60-day head-down bed rest (HDBR). METHOD: Twenty healthy male volunteers were included and received a daily multivitamin supplementation in a double-blind fashion. At baseline, 29 and 52âdays during strict HDBR, then 12 and 30âdays after HDBR, aortic stiffness was measured using carotid-to-femoral pulse wave velocity (cf-PWV) and aortic MRI. Carotid, femoral, brachial and popliteal arteries were studied by ultrasound echo tracking, central blood pressure (BP) by tonometry and endothelial function by flow-mediated dilatation. RESULTS: Cf-PWV increased during HDBR (+0.8 and +1.1m/s, at D29 and D52, respectively, Pâ=â0.004), corresponding to an increase in vascular age up to +11âyears (Pâ=â0.003). Changes were similar to those observed on MRI (+0.8âm/s at D52, Pâ<â0.01) and were independent of BP and heart rate changes. After HDBR, cf-PWV showed a substantial recovery at R12 but still remained higher than baseline at R30 (+0.8âm/s, Pâ=â0.018), corresponding to +6.5âyears of vascular aging (Pâ=â0.018). Thoracic aorta diameter increased significantly (+6%, Pâ=â0.0008). During HDBR, femoral and popliteal arteries showed dimensional changes, leading to femoral inward hypotrophic remodeling (femoral diameter: -12%, Pâ<â0.05; wall cross-sectional area: -25%, Pâ=â0.014) and popliteal inward eutrophic remodeling (popliteal diameter: -25%, Pâ<â0.05; wall cross-sectional area: -3%, Pâ=â0.51). After HDBR, both arterial territories of the leg recovered. We did not observe any significant changes for carotid arteries nor for endothelial function during and after HDBR. Multivitamin supplementation did not affect vascular changes. HDBR was associated with an important increase in aortic stiffness, which did not completely recover 1 month after the end of HDBR. The thoracic aorta and the lower body muscular arteries underwent significant changes in dimensions whereas the common carotid arteries were preserved. CONCLUSION: These results should raise caution for those exposed to microgravity, real or simulated.
Asunto(s)
Reposo en Cama , Rigidez Vascular , Reposo en Cama/efectos adversos , Presión Sanguínea , Arterias Carótidas , Método Doble Ciego , Humanos , Masculino , Análisis de la Onda del PulsoRESUMEN
BACKGROUND: Atrial fibrillation affects approximately 4% of the world's population and is one of the major causes of stroke, heart failure, sudden death, and cardiovascular morbidity. It can be difficult to diagnose when asymptomatic or in the paroxysmal stage, and its natural history is not well understood. New wearables and connected devices offer an opportunity to improve on this situation. OBJECTIVE: We aimed to validate an algorithm for the automatic detection of atrial fibrillation from a single-lead electrocardiogram taken with a smartwatch. METHODS: Eligible patients were recruited from 4 sites in Paris, France. Electrocardiograms (12-lead reference and single lead) were captured simultaneously. The electrocardiograms were reviewed by independent, blinded board-certified cardiologists. The sensitivity and specificity of the algorithm to detect atrial fibrillation and normal sinus rhythm were calculated. The quality of single-lead electrocardiograms (visibility and polarity of waves, interval durations, heart rate) was assessed in comparison with the gold standard (12-lead electrocardiogram). RESULTS: A total of 262 patients (atrial fibrillation: n=100, age: mean 74.3 years, SD 12.3; normal sinus rhythm: n=113, age: 61.8 years, SD 14.3; other arrhythmia: n=45, 66.9 years, SD 15.2; unreadable electrocardiograms: n=4) were included in the final analysis; 6.9% (18/262) were classified as Noise by the algorithm. Excluding other arrhythmias and Noise, the sensitivity for atrial fibrillation detection was 0.963 (95% CI lower bound 0.894), and the specificity was 1.000 (95% CI lower bound 0.967). Visibility and polarity accuracies were similar (1-lead electrocardiogram: P waves: 96.9%, QRS complexes: 99.2%, T waves: 91.2%; 12-lead electrocardiogram: P waves: 100%, QRS complexes: 98.8%, T waves: 99.5%). P-wave visibility accuracy was 99% (99/100) for patients with atrial fibrillation and 95.7% (155/162) for patients with normal sinus rhythm, other arrhythmias, and unreadable electrocardiograms. The absolute values of the mean differences in PR duration and QRS width were <3 ms, and more than 97% were <40 ms. The mean difference between the heart rates from the 1-lead electrocardiogram calculated by the algorithm and those calculated by cardiologists was 0.55 bpm. CONCLUSIONS: The algorithm demonstrated great diagnostic performance for atrial fibrillation detection. The smartwatch's single-lead electrocardiogram also demonstrated good quality for physician use in daily routine care. TRIAL REGISTRATION: ClinicalTrials.gov NCT04351386; http://clinicaltrials.gov/ct2/show/NCT04351386.
RESUMEN
AIMS: Hypertension is a major contributor to cardiac diastolic dysfunction. Different therapeutics strategies have been proposed to control blood pressure (BP), but their independent impact on cardiac function remains undetermined. In patients with resistant hypertension, we compared the changes in cardiac parameters between two strategies based on sequential nephron blockade (NBD) with a combination of diuretics or sequential renin-angiotensin system blockade (RASB). METHODS AND RESULTS: After a 4-week period where all patients received Irbesartan 300 mg/day + hydrochlorothiazide 12.5 mg/day + amlodipine 5 mg/day, 140 resistant hypertension patients (54.8 ± 11.1 years, 76% men, mean duration with hypertension: 13.1 ± 10.5 years, no previous history of heart failure or current symptoms of congestive heart failure) were randomized 1:1 to the NBD regimen or to the RASB regimen at week 0 (W0, baseline). Treatment intensity was increased at week 4, 8, or 10 if home BP was ≥135/85 mmHg, by sequentially adding 25 mg spironolactone, 20-40 mg furosemide, and 5 mg amiloride (NBD group) or 5-10 mg ramipril and 5-10 mg bisoprolol (RASB group). No other antihypertensive drug was allowed during the study. BP, BNP levels, and echocardiographic parameters were assessed at weeks 0 and 12. The baseline characteristics, laboratory parameters, and plasma hormones (BNP, renin, and aldosterone) and cardiac echocardiographic parameters did not significantly differ between the NBD and the RASB groups. Over 12 weeks, BNP levels significantly decreased in NBD but increased in RASB (mean [CI 95%] change in log-transformed BNP levels: -43% [-67%; -23%] vs. +55% [46%; 62%] in NBD vs. RASB, respectively, P < 0.0001). Similarly, the proportion of patients presenting ≥2 echocardiographic criteria of diastolic dysfunction decreased between baseline and W12 from 31% to 3% in NBD but increased from 19% to 32% in RASB (P = 0.0048). As compared with RASB, NBD induced greater decrease in ambulatory systolic BP (P < 0.0001), pulse pressure (P < 0.0001), and systemic vascular resistance (P < 0.005). In multivariable linear regression analyses, NBD treatment was significantly associated with decreased BNP levels (adjusted ß: -46.41 ± 6.99, P < 0.0001) independent of age, gender, renal function, and changes in BPs or heart rate. CONCLUSIONS: In patients with resistant hypertension, nephron blockade with a combination of diuretics significantly improves cardiac markers of diastolic dysfunction independently of BP lowering.
Asunto(s)
Diuréticos , Hipertensión , Antihipertensivos/farmacología , Antihipertensivos/uso terapéutico , Presión Sanguínea , Femenino , Humanos , Hipertensión/tratamiento farmacológico , Masculino , NefronasRESUMEN
Resistant hypertension is defined as uncontrolled blood pressure (BP) despite three antihypertensive agents including a diuretic (thiazide diuretic if renal function is normal or loop diuretic in case of chronic kidney disease with eGFR<30mL/min), a renin-angiotensin system blocker (ARB or ACEI) and a calcium channel blocker, at optimal doses. Resistance must be confirmed by out-of-office measurements (ambulatory blood pressure monitoring or home blood pressure monitoring) and patients should be asked about treatment compliance and excessive salt or alcohol intake. If the diagnosis of resistant hypertension is confirmed, the patient should be referred to a hypertension specialist to screen for secondary causes of hypertension as they are frequent in this context. If essential resistant hypertension is confirmed, the mineralocorticoid receptor antagonist, spironolactone, should be added (25 to 50mg daily). In the event of a contraindication to spironolactone, or if adverse effects occur, a beta-blocker, an alpha-blocker, or a centrally acting antihypertensive drug should be prescribed.