J Neurosci ; 43(1): 2-13, 2023 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-36028313

RESUMEN

A question relevant to nicotine addiction is how nicotine and other nicotinic receptor membrane-permeant ligands, such as the anti-smoking drug varenicline (Chantix), distribute in brain. Ligands, like varenicline, with high pKa and high affinity for α4ß2-type nicotinic receptors (α4ß2Rs) are trapped in intracellular acidic vesicles containing α4ß2Rs in vitro Nicotine, with lower pKa and α4ß2R affinity, is not trapped. Here, we extend our results by imaging nicotinic PET ligands in vivo in male and female mouse brain and identifying the trapping brain organelle in vitro as Golgi satellites (GSats). Two PET 18F-labeled imaging ligands were chosen: [18F]2-FA85380 (2-FA) with varenicline-like pKa and affinity and [18F]Nifene with nicotine-like pKa and affinity. [18F]2-FA PET-imaging kinetics were very slow consistent with 2-FA trapping in α4ß2R-containing GSats. In contrast, [18F]Nifene kinetics were rapid, consistent with its binding to α4ß2Rs but no trapping. Specific [18F]2-FA and [18F]Nifene signals were eliminated in ß2 subunit knock-out (KO) mice or by acute nicotine (AN) injections demonstrating binding to sites on ß2-containing receptors. Chloroquine (CQ), which dissipates GSat pH gradients, reduced [18F]2-FA distributions while having little effect on [18F]Nifene distributions in vivo consistent with only [18F]2-FA trapping in GSats. These results are further supported by in vitro findings where dissipation of GSat pH gradients blocks 2-FA trapping in GSats without affecting Nifene. By combining in vitro and in vivo imaging, we mapped both the brain-wide and subcellular distributions of weak-base nicotinic receptor ligands. We conclude that ligands, such as varenicline, are trapped in neurons in α4ß2R-containing GSats, which results in very slow release long after nicotine is gone after smoking.SIGNIFICANCE STATEMENT Mechanisms of nicotine addiction remain poorly understood. An earlier study using in vitro methods found that the anti-smoking nicotinic ligand, varenicline (Chantix) was trapped in α4ß2R-containing acidic vesicles. Using a fluorescent-labeled high-affinity nicotinic ligand, this study provided evidence that these intracellular acidic vesicles were α4ß2R-containing Golgi satellites (GSats). In vivo PET imaging with F-18-labeled nicotinic ligands provided additional evidence that differences in PET ligand trapping in acidic vesicles were the cause of differences in PET ligand kinetics and subcellular distributions. These findings combining in vitro and in vivo imaging revealed new mechanistic insights into the kinetics of weak base PET imaging ligands and the subcellular mechanisms underlying nicotine addiction.


Asunto(s)
Receptores Nicotínicos , Tabaquismo , Ratones , Animales , Masculino , Femenino , Nicotina/farmacología , Vareniclina/metabolismo , Vareniclina/farmacología , Tabaquismo/metabolismo , Ligandos , Receptores Nicotínicos/metabolismo , Tomografía de Emisión de Positrones/métodos , Encéfalo/metabolismo
2.
J Labelled Comp Radiopharm ; 67(1): 31-36, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37927198

RESUMEN

The α4ß2 nicotinic acetylcholine receptor (nAChR) ligand 2-[18 F]fluoro-3-[2-((S)-3-pyrrolinyl)methoxy]pyridine ([18 F]nifene) has been synthesized in 10% decay-corrected radiochemical yield using the IBA Synthera® platform (IBA Cyclotron Solutions, Louvain-la-Neuve, Belgium) with an integrated fluidic processor (IFP). Boc-nitronifene served as the precursor, and 20% trifluoroacetic acid (TFA) was used to deprotect the Boc-group after radiolabeling. By omitting the solvent extraction step after radiolabeling, the process was simplified to a single step with no manual intervention. [18 F]Nifene was obtained in decay-corrected radiochemical yields of 10 ± 2% (n = 20) and radiochemical purity >99%. Typical specific radioactivities of 2700-4865 mCi/µmole (100-180 GBq/µmol) were measured at the end of synthesis; total synthesis times were about 1 h 40 min.


Asunto(s)
Piridinas , Receptores Nicotínicos , Pirroles , Radiofármacos , Ligandos
3.
Molecules ; 29(4)2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38398551

RESUMEN

Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac)2], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 (48V) generated with a compact medical cyclotron has been used to label VO(acac)2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac)2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac)2, [48V]VO(acac)2, and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [48V]VO(acac)2. Preliminary results of preclinical, small-animal PET studies are presented.


Asunto(s)
Hidroxibutiratos , Neoplasias , Pentanonas , Radioisótopos , Vanadio , Animales , Cromatografía Líquida de Alta Presión , Vanadio/química , Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones
4.
Int J Mol Sci ; 24(21)2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37958495

RESUMEN

Positron emission tomography (PET) radioligands that bind with high-affinity to α4ß2-type nicotinic receptors (α4ß2Rs) allow for in vivo investigations of the mechanisms underlying nicotine addiction and smoking cessation. Here, we investigate the use of an image-derived arterial input function and the cerebellum for kinetic analysis of radioligand binding in mice. Two radioligands were explored: 2-[18F]FA85380 (2-FA), displaying similar pKa and binding affinity to the smoking cessation drug varenicline (Chantix), and [18F]Nifene, displaying similar pKa and binding affinity to nicotine. Time-activity curves of the left ventricle of the heart displayed similar distribution across wild type mice, mice lacking the ß2-subunit for ligand binding, and acute nicotine-treated mice, whereas reference tissue binding displayed high variation between groups. Binding potential estimated from a two-tissue compartment model fit of the data with the image-derived input function were higher than estimates from reference tissue-based estimations. Rate constants of radioligand dissociation were very slow for 2-FA and very fast for Nifene. We conclude that using an image-derived input function for kinetic modeling of nicotinic PET ligands provides suitable results compared to reference tissue-based methods and that the chemical properties of 2-FA and Nifene are suitable to study receptor response to nicotine addiction and smoking cessation therapies.


Asunto(s)
Receptores Nicotínicos , Tabaquismo , Ratones , Animales , Nicotina/farmacología , Nicotina/metabolismo , Encéfalo/metabolismo , Tabaquismo/metabolismo , Cinética , Ligandos , Tomografía de Emisión de Positrones/métodos , Receptores Nicotínicos/genética , Receptores Nicotínicos/metabolismo
5.
Molecules ; 28(16)2023 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-37630292

RESUMEN

In the field of nuclear medicine, the ß+ -emitting 43Sc and ß- -emitting 47Sc are promising candidates in cancer diagnosis and targeted radionuclide therapy (TRT) due to their favorable decay schema and shared pharmacokinetics as a true theranostic pair. Additionally, scandium is a group-3 transition metal (like 177Lu) and exhibits affinity for DOTA-based chelators, which have been studied in depth, making the barrier to implementation lower for 43/47Sc than for other proposed true theranostics. Before 43/47Sc can see widespread pre-clinical evaluation, however, an accessible production methodology must be established and each isotope's radiolabeling and animal imaging capabilities studied with a widely utilized tracer. As such, a simple means of converting an 18 MeV biomedical cyclotron to support solid targets and produce 43Sc via the 42Ca(d,n)43Sc reaction has been devised, exhibiting reasonable yields. The NatTi(γ,p)47Sc reaction is also investigated along with the successful implementation of chemical separation and purification methods for 43/47Sc. The conjugation of 43/47Sc with PSMA-617 at specific activities of up to 8.94 MBq/nmol and the subsequent imaging of LNCaP-ENZaR tumor xenografts in mouse models with both 43/47Sc-PSMA-617 are also presented.


Asunto(s)
Medicina Nuclear , Neoplasias de la Próstata , Humanos , Animales , Ratones , Masculino , Escandio , Medicina de Precisión , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radioisótopos/uso terapéutico
6.
Eur J Nucl Med Mol Imaging ; 49(12): 4014-4024, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35792927

RESUMEN

PURPOSE: To identify the optimal threshold in 18F-fluoromisonidazole (FMISO) PET images to accurately locate tumor hypoxia by using electron paramagnetic resonance imaging (pO2 EPRI) as ground truth for hypoxia, defined by pO2 [Formula: see text] 10 mmHg. METHODS: Tumor hypoxia images in mouse models of SCCVII squamous cell carcinoma (n = 16) were acquired in a hybrid PET/EPRI imaging system 2 h post-injection of FMISO. T2-weighted MRI was used to delineate tumor and muscle tissue. Dynamic contrast enhanced (DCE) MRI parametric images of Ktrans and ve were generated to model tumor vascular properties. Images from PET/EPR/MRI were co-registered and resampled to isotropic 0.5 mm voxel resolution for analysis. PET images were converted to standardized uptake value (SUV) and tumor-to-muscle ratio (TMR) units. FMISO uptake thresholds were evaluated using receiver operating characteristic (ROC) curve analysis to find the optimal FMISO threshold and unit with maximum overall hypoxia similarity (OHS) with pO2 EPRI, where OHS = 1 shows perfect overlap and OHS = 0 shows no overlap. The means of dice similarity coefficient, normalized Hausdorff distance, and accuracy were used to define the OHS. Monotonic relationships between EPRI/PET/DCE-MRI were evaluated with the Spearman correlation coefficient ([Formula: see text]) to quantify association of vasculature on hypoxia imaged with both FMISO PET and pO2 EPRI. RESULTS: FMISO PET thresholds to define hypoxia with maximum OHS (both OHS = 0.728 [Formula: see text] 0.2) were SUV [Formula: see text] 1.4 [Formula: see text] SUVmean and SUV [Formula: see text] 0.6 [Formula: see text] SUVmax. Weak-to-moderate correlations (|[Formula: see text]|< 0.70) were observed between PET/EPRI hypoxia images with vascular permeability (Ktrans) or fractional extracellular-extravascular space (ve) from DCE-MRI. CONCLUSION: This is the first in vivo comparison of FMISO uptake with pO2 EPRI to identify the optimal FMISO threshold to define tumor hypoxia, which may successfully direct hypoxic tumor boosts in patients, thereby enhancing tumor control.


Asunto(s)
Carcinoma de Células Escamosas , Hipoxia Tumoral , Animales , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Hipoxia de la Célula , Espectroscopía de Resonancia por Spin del Electrón , Hipoxia/diagnóstico por imagen , Ratones , Misonidazol/análogos & derivados , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Tomografía Computarizada por Rayos X
7.
Angew Chem Int Ed Engl ; 59(35): 15161-15165, 2020 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-32415874

RESUMEN

Herein, we report the development of an 18 F-labeled, activity-based small-molecule probe targeting the cancer-associated serine hydrolase NCEH1. We undertook a focused medicinal chemistry campaign to simultaneously preserve potent and specific NCEH1 labeling in live cells and animals, while permitting facile 18 F radionuclide incorporation required for PET imaging. The resulting molecule, [18 F]JW199, labels active NCEH1 in live cells at nanomolar concentrations and greater than 1000-fold selectivity relative to other serine hydrolases. [18 F]JW199 displays rapid, NCEH1-dependent accumulation in mouse tissues. Finally, we demonstrate that [18 F]JW199 labels aggressive cancer tumor cells in vivo, which uncovered localized NCEH1 activity at the leading edge of triple-negative breast cancer tumors, suggesting roles for NCEH1 in tumor aggressiveness and metastasis.


Asunto(s)
Radioisótopos de Flúor/uso terapéutico , Tomografía de Emisión de Positrones/métodos , Esterol Esterasa/metabolismo , Animales , Femenino , Humanos , Ratones
8.
J Lipid Res ; 58(4): 752-762, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28167703

RESUMEN

Reverse cholesterol transport (RCT) is thought to be an atheroprotective function of HDL, and macrophage-specific RCT in mice is inversely associated with atherosclerosis. We developed a novel method using 3H-cholesterol nanoparticles to selectively trace macrophage-specific RCT in vivo in humans. Use of 3H-cholesterol nanoparticles was initially tested in mice to assess the distribution of tracer and response to interventions known to increase RCT. Thirty healthy subjects received 3H-cholesterol nanoparticles intravenously, followed by blood and stool sample collection. Tracer counts were assessed in plasma, nonHDL, HDL, and fecal fractions. Data were analyzed by using multicompartmental modeling. Administration of 3H-cholesterol nanoparticles preferentially labeled macrophages of the reticuloendothelial system in mice, and counts were increased in mice treated with a liver X receptor agonist or reconstituted HDL, as compared with controls. In humans, tracer disappeared from plasma rapidly after injection of nanoparticles, followed by reappearance in HDL and nonHDL fractions. Counts present as free cholesterol increased rapidly and linearly in the first 240 min after nadir; counts in cholesteryl ester increased steadily over time. Estimates of fractional transfer rates of key RCT steps were obtained. These results support the use of 3H-cholesterol nanoparticles as a feasible approach for the measurement of macrophage RCT in vivo in humans.


Asunto(s)
Aterosclerosis/sangre , HDL-Colesterol/sangre , Colesterol/sangre , Lipoproteínas HDL/metabolismo , Adolescente , Adulto , Anciano , Animales , Aterosclerosis/patología , Transporte Biológico/genética , Colesterol/química , Colesterol/genética , HDL-Colesterol/química , HDL-Colesterol/aislamiento & purificación , Heces/química , Femenino , Humanos , Lipoproteínas HDL/aislamiento & purificación , Hígado/metabolismo , Hígado/patología , Receptores X del Hígado/agonistas , Receptores X del Hígado/sangre , Macrófagos/metabolismo , Masculino , Ratones , Persona de Mediana Edad , Nanopartículas/administración & dosificación , Nanopartículas/química
9.
Phys Med Biol ; 68(1)2022 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-36571231

RESUMEN

Objective. In this work, the irradiation of natural titanium foils in the beam-stop of a compact medical cyclotron, an IBA CYCLONE 18/9, is simulated to assess the efficacy of using a beam-stop as a target holder, and using two different target geometries, in the production of vanadium-48, a positron-emitting radioisotope with potential utility as a cancer imaging agent in positron emission tomography.Approach. TOPAS, the TOol for PArticle Simulation, a Geant4-based Monte Carlo program, was used to model the cyclotron beam parameters, choose an appropriate physics list, and simulate the irradiation of targets made from foils of 12 or 12.5µm thickness. These simulation yields were compared to theoretical yields calculated using cross section data from the literature, as well as assayed yields from experimental irradiations.Main results.We found that most physics lists in TOPAS overestimate the cross section in the desired energy range (16-20 MeV) by at least 136%, with the exception of those using the Bertini Cascade Model. Compared to assayed yields, TOPAS provided a minimum of 0.4% error for cup-shaped targets and at least a 12% overestimation for sphere-shaped targets.Significance.These simulations provide a tool to help explain irregularities in radioisotope production yield and motivate modifications to increase target yield.


Asunto(s)
Ciclotrones , Tomografía Computarizada por Rayos X , Radioisótopos , Simulación por Computador , Tomografía de Emisión de Positrones , Método de Montecarlo
10.
Appl Radiat Isot ; 186: 110270, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35569262

RESUMEN

In this preliminary study, a procedure for synthesizing novel PET radiotracer vanadium-48-labeled-vanadyl acetylacetonate was developed, including radioisotope production via cyclotron, separation of 48V, chelation as 48VO(acac)2, and assessment through in vitro cellular studies. We employed the beam-stop setup in a cyclotron as the target holder to irradiate titanium foils in the reaction of natTi (p,n)48V. The radioisotope production rate was 4.84 ± 0.67 µCi/µA-h. Overall radiochemical yield was 12.86 ± 0.51% with gamma-ray spectroscopy showing no detectable contaminant peaks. HPLC of 48VO(acac)2 showed a retention time (1:48) corresponding closely to that (1:50) of commercial VO(acac)2, verifying the successful synthesis of 48VO(acac)2. In vitro cellular studies demonstrated radiotracer uptake and saturation around 0.48 nM. These studies pave the way for improving methodologies and in vivo experiments, including imaging studies, in future investigations.


Asunto(s)
Neoplasias , Humanos , Neoplasias/diagnóstico por imagen , Análisis Espectral
11.
Radiol Imaging Cancer ; 3(2): e200104, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33817651

RESUMEN

Purpose: To enhance the spatial accuracy of fluorine 18 (18F) misonidazole (MISO) PET imaging of hypoxia by using dynamic contrast-enhanced (DCE) MR images as a basis for modifying PET images and by using electron paramagnetic resonance (EPR) partial oxygen pressure (pO2) as the reference standard. Materials and Methods: Mice (n = 10) with leg-borne MCa4 mammary carcinomas underwent EPR imaging, T2-weighted and DCE MRI, and 18F-MISO PET/CT. Images were registered to the same space for analysis. The thresholds of hypoxia for PET and EPR images were tumor-to-muscle ratios greater than or equal to 2.2 mm Hg and less than or equal to 14 mm Hg, respectively. The Dice similarity coefficient (DSC) and Hausdorff distance (d H ) were used to quantify the three-dimensional overlap of hypoxia between pO2 EPR and 18F-MISO PET images. A training subset (n = 6) was used to calculate optimal DCE MRI weighting coefficients to relate EPR to the PET signal; the group average weights were then applied to all tumors (from six training mice and four test mice). The DSC and d H were calculated before and after DCE MRI-corrected PET images were obtained to quantify the improvement in overlap with EPR pO2 images for measuring tumor hypoxia. Results: The means and standard deviations of the DSC and d H between hypoxic regions in original PET and EPR images were 0.35 mm ± 0.23 and 5.70 mm ± 1.7, respectively, for images of all 10 mice. After implementing a preliminary DCE MRI correction to PET data, the DSC increased to 0.86 mm ± 0.18 and the d H decreased to 2.29 mm ± 0.70, showing significant improvement (P < .001) for images of all 10 mice. Specifically, for images of the four independent test mice, the DSC improved with correction from 0.19 ± 0.28 to 0.80 ± 0.29 (P = .02), and the d H improved from 6.40 mm ± 2.5 to 1.95 mm ± 0.63 (P = .01). Conclusion: Using EPR information as a reference standard, DCE MRI information can be used to correct 18F-MISO PET information to more accurately reflect areas of hypoxia.Keywords: Animal Studies, Molecular Imaging, Molecular Imaging-Cancer, PET/CT, MR-Dynamic Contrast Enhanced, MR-Imaging, PET/MR, Breast, Oncology, Tumor Mircoenvironment, Electron Paramagnetic ResonanceSupplemental material is available for this article.© RSNA, 2021.


Asunto(s)
Misonidazol , Hipoxia Tumoral , Animales , Espectroscopía de Resonancia por Spin del Electrón , Hipoxia/diagnóstico por imagen , Imagen por Resonancia Magnética , Ratones , Oxígeno , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones
12.
Eur J Nucl Med Mol Imaging ; 37(11): 2048-59, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20585774

RESUMEN

PURPOSE: The primary purpose of this study was to assess the biodistribution and radiation dose resulting from administration of (18)F-EF5, a lipophilic 2-nitroimidazole hypoxia marker in ten cancer patients. For three of these patients (with glioblastoma) unlabeled EF5 was additionally administered to allow the comparative assessment of (18)F-EF5 tumor uptake with EF5 binding, the latter measured in tumor biopsies by fluorescent anti-EF5 monoclonal antibodies. METHODS: (18)F-EF5 was synthesized by electrophilic addition of (18)F(2) gas, made by deuteron bombardment of a neon/fluorine mixture in a high-pressure gas target, to an allyl precursor in trifluoroacetic acid at 0° then purified and administered by intravenous bolus. Three whole-body images were collected for each of ten patients using an Allegro (Philips) scanner. Gamma counts were determined in blood, drawn during each image, and urine, pooled as a single sample. PET images were analyzed to determine radiotracer uptake in several tissues and the resulting radiation dose calculated using OLINDA software and standard phantom. For three patients, 21 mg/kg unlabeled EF5 was administered after the PET scans, and tissue samples obtained the next day at surgery to determine EF5 binding using immunohistochemistry techniques (IHC). RESULTS: EF5 distributes evenly throughout soft tissue within minutes of injection. Its concentration in blood over the typical time frame of the study (∼3.5 h) was nearly constant, consistent with a previously determined EF5 plasma half-life of ∼13 h. Elimination was primarily via urine and bile. Radiation exposure from labeled EF5 is similar to other (18)F-labeled imaging agents (e.g., FDG and FMISO). In a de novo glioblastoma multiforme patient, focal uptake of (18)F-EF5 was confirmed by IHC. CONCLUSION: These results confirm predictions of biodistribution and safety based on EF5's characteristics (high biological stability, high lipophilicity). EF5 is a novel hypoxia marker with unique pharmacological characteristics allowing both noninvasive and invasive measurements.


Asunto(s)
Neoplasias Encefálicas/metabolismo , Etanidazol/análogos & derivados , Radioisótopos de Flúor , Glioblastoma/metabolismo , Hidrocarburos Fluorados/metabolismo , Hidrocarburos Fluorados/farmacocinética , Transporte Biológico , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Hipoxia de la Célula , Etanidazol/metabolismo , Etanidazol/farmacocinética , Femenino , Glioblastoma/diagnóstico por imagen , Glioblastoma/patología , Humanos , Inmunohistoquímica , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Radiometría , Distribución Tisular , Imagen de Cuerpo Entero
13.
Nucl Med Commun ; 30(4): 314-8, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19242386

RESUMEN

OBJECTIVE: 11C-carfentanil is a radiopharmaceutical that selectively binds the mu-opiate receptor of the central nervous system. However, its dosimetry throughout the body and other organs has never been reported in the literature. The purpose of this study was to measure the radiation dosimetry of 11C-carfentanil in healthy human volunteers. The study was conducted within a regulatory framework that required its pharmacological safety to be assessed simultaneously. METHODS: The sample included two male and three female participants ranging in age from 28 to 49 years. Three to four scans were obtained over approximately 2 h starting immediately after the intravenous administration of 0.03 microg/kg of [C]carfentanil injected as a slow bolus (mean activity injected was 280+/-68 MBq). The fraction of the administered dose in 10 regions of interest was quantified from the attenuation-corrected counts obtained on the axial images. Monoexponential functions were fit to each time-activity curve using a nonlinear, least-squares regression algorithm. These curves were numerically integrated to yield the number of disintegrations per unit activity administered in source organs. Sex-specific radiation doses were then estimated with the medical internal radiation dose technique. RESULTS: A few participants reported mild pharmacological effects of the radiotracer, primarily mild drowsiness, which is an expected side effect. The dose-limiting organ was the bladder wall, which received a mean of 3.65E-02 mGy/MBq. The mean effective dose equivalent and effective dose for 11C-carfentanil were 5.38E-03 and 4.59E-03 mSv/MBq, respectively. CONCLUSION: The observed dosimetry values for 11C-carfentanil indicate that it is safe for imaging micro-opiate receptors in the central nervous system and periphery.


Asunto(s)
Analgésicos Opioides/administración & dosificación , Fentanilo/análogos & derivados , Radiofármacos/administración & dosificación , Receptores Opioides mu/efectos de los fármacos , Adulto , Analgésicos Opioides/efectos adversos , Electrocardiografía , Femenino , Fentanilo/administración & dosificación , Fentanilo/efectos adversos , Humanos , Procesamiento de Imagen Asistido por Computador , Marcaje Isotópico , Análisis de los Mínimos Cuadrados , Masculino , Persona de Mediana Edad , Dinámicas no Lineales , Radiometría , Radiofármacos/efectos adversos , Análisis de Regresión , Caracteres Sexuales , Distribución Tisular
14.
Med Phys ; 35(2): 446-55, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18383664

RESUMEN

We acquire and compare three-dimensional tomographic breast images of three females with suspicious masses using diffuse optical tomography (DOT) and positron emission tomography (PET). Co-registration of DOT and PET images was facilitated by a mutual information maximization algorithm. We also compared DOT and whole-body PET images of 14 patients with breast abnormalities. Positive correlations were found between total hemoglobin concentration and tissue scattering measured by DOT, and fluorodeoxyglucose (18F-FDG) uptake. In light of these observations, we suggest potential benefits of combining both PET and DOT for characterization of breast lesions.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Mama/diagnóstico por imagen , Mama/patología , Tomografía de Emisión de Positrones/métodos , Tomografía Óptica/métodos , Imagen de Cuerpo Entero/métodos , Femenino , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Sci Rep ; 8(1): 607, 2018 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-29330383

RESUMEN

Central nervous system (CNS) demyelination represents the pathological hallmark of multiple sclerosis (MS) and contributes to other neurological conditions. Quantitative and specific imaging of demyelination would thus provide critical clinical insight. Here, we investigated the possibility of targeting axonal potassium channels to image demyelination by positron emission tomography (PET). These channels, which normally reside beneath the myelin sheath, become exposed upon demyelination and are the target of the MS drug, 4-aminopyridine (4-AP). We demonstrate using autoradiography that 4-AP has higher binding in non-myelinated and demyelinated versus well-myelinated CNS regions, and describe a fluorine-containing derivative, 3-F-4-AP, that has similar pharmacological properties and can be labeled with 18F for PET imaging. Additionally, we demonstrate that [18F]3-F-4-AP can be used to detect demyelination in rodents by PET. Further evaluation in Rhesus macaques shows higher binding in non-myelinated versus myelinated areas and excellent properties for brain imaging. Together, these data indicate that [18F]3-F-4-AP may be a valuable PET tracer for detecting CNS demyelination noninvasively.


Asunto(s)
4-Aminopiridina/administración & dosificación , Enfermedades Desmielinizantes/diagnóstico por imagen , Radioisótopos de Flúor/química , Tomografía de Emisión de Positrones/métodos , Canales de Potasio/metabolismo , 4-Aminopiridina/química , 4-Aminopiridina/farmacología , Animales , Enfermedades Desmielinizantes/metabolismo , Femenino , Humanos , Macaca mulatta , Masculino , Ratones , Trazadores Radiactivos , Ratas
16.
J Clin Endocrinol Metab ; 92(12): 4706-11, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17895314

RESUMEN

OBJECTIVES: Focal lesions in infants with congenital hyperinsulinism (HI) represent areas of adenomatosis that express a paternally derived ATP-sensitive potassium channel mutation due to embryonic loss of heterozygosity for the maternal 11p region. This study evaluated the accuracy of 18F-fluoro-l-dihydroxyphenylalanine ([18F]DOPA) positron emission tomography (PET) scans in diagnosing focal vs. diffuse disease and identifying the location of focal lesions. DESIGN: A total of 50 infants with HI unresponsive to medical therapy were studied. Patients were injected iv with [18F]DOPA, and PET scans were obtained for 50-60 min. Images were coregistered with abdominal computed tomography scans. PET scan interpretations were compared with histological diagnoses. RESULTS: The diagnosis of focal or diffuse HI was correct in 44 of the 50 cases (88%). [18F]DOPA PET identified focal areas of high uptake of radiopharmaceutical in 18 of 24 patients with focal disease. The locations of these lesions matched the areas of increased [18F]DOPA uptake on the PET scans in all of the cases. PET scan correctly located five lesions that could not be visualized at surgery. The positive predictive value of [18F]DOPA in diagnosing focal adenomatosis was 100%, and the negative predictive value was 81%. CONCLUSIONS: [18F]DOPA PET scans correctly diagnosed 75% of focal cases and were 100% accurate in identifying the location of the lesion. These results suggest that [18F]DOPA PET imaging provides a useful guide to surgical resection of focal adenomatosis and should be considered as a guide to surgery in all infants with congenital HI who have medically uncontrollable disease.


Asunto(s)
Dihidroxifenilalanina/análogos & derivados , Hiperinsulinismo/congénito , Hiperinsulinismo/diagnóstico por imagen , Radiofármacos , Biopsia , Humanos , Hiperinsulinismo/patología , Interpretación de Imagen Asistida por Computador , Lactante , Recién Nacido , Islotes Pancreáticos/patología , Riñón/patología , Neoplasia Endocrina Múltiple/diagnóstico por imagen , Neoplasia Endocrina Múltiple/patología , Pancreatectomía , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Tomografía de Emisión de Positrones , Tamaño de la Muestra
17.
J Pediatr ; 150(2): 140-5, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17236890

RESUMEN

OBJECTIVES: To assess the accuracy of 18F-fluoro-L-dihydroxyphenylalanine ([18F]-DOPA) PET scans to diagnose focal versus diffuse disease and to localize focal lesions in infants with congenital hyperinsulinism. STUDY DESIGN: Twenty-four infants with hyperinsulinism unresponsive to medical therapy were studied. Patients were injected intravenously with [18F]-DOPA, and PET scans were obtained for 1 hour. Images were coregistered with abdominal CT scans. RESULTS: The diagnosis of focal or diffuse hyperinsulinism was correct in 23 of the 24 cases (96%) and equivocal in 1 case. [18F]-DOPA PET identified focal areas of high uptake of radiopharmaceutical in 11 patients. Pathology results confirmed that all 11 had focal adenomatosis, and the locations of these lesions matched the areas of increased [18F]-DOPA uptake on the PET scans in all of the cases. CONCLUSIONS: [18F]-DOPA PET scans were 96% accurate in diagnosing focal or diffuse disease and 100% accurate in localizing the focal lesion. These results suggest that [18F]-DOPA PET imaging should be considered in all infants with congenital hyperinsulinism who need to have pancreatectomy.


Asunto(s)
Hiperinsulinismo Congénito/diagnóstico por imagen , Dihidroxifenilalanina/análogos & derivados , Tomografía de Emisión de Positrones/métodos , Intervalos de Confianza , Hiperinsulinismo Congénito/fisiopatología , Femenino , Humanos , Lactante , Recién Nacido , Inyecciones Intravenosas , Masculino , Páncreas/diagnóstico por imagen , Estudios Prospectivos , Medición de Riesgo , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
18.
J Vis Exp ; (123)2017 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-28605366

RESUMEN

3-[18F]fluoro-4-aminopyridine, [18F]3F4AP, is a radiofluorinated analog of the FDA-approved drug for multiple sclerosis 4-aminopyridine (4AP). This compound is currently under investigation as a PET tracer for demyelination. We recently described a novel chemical reaction to produce metafluorinated pyridines consisting of direct fluorination of a pyridine N-oxide and the utilization of this reaction for the radiochemical synthesis of [18F]3F4AP. In this article, we demonstrate how to produce this tracer using an automated synthesizer and an in-house made flow hydrogenation reactor. We also show the standard quality control procedures performed before releasing the radiotracer for preclinical animal imaging studies. This semi-automated procedure may serve as the basis for future production of [18F]3F4AP for clinical studies.


Asunto(s)
Aminopiridinas/síntesis química , Enfermedades Desmielinizantes/diagnóstico por imagen , Radioisótopos de Flúor/química , Esclerosis Múltiple/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Radiofármacos/síntesis química , Enfermedades Desmielinizantes/patología , Humanos , Esclerosis Múltiple/patología
19.
J Nucl Med ; 44(8): 1340-9, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12902426

RESUMEN

UNLABELLED: A high-sensitivity, high-resolution brain PET scanner ("G-PET") has been developed. This scanner is similar in geometry to a previous brain scanner developed at the University of Pennsylvania, the HEAD Penn-PET, but the detector technology and electronics have been improved to achieve enhanced performance. METHODS: This scanner has a detector ring diameter of 42.0 cm with a patient aperture of 30.0 cm and an axial field of view of 25.6 cm. It comprises a continuous light-guide that couples 18,560 (320 x 58 array) 4 x 4 x 10 mm(3) gadolinium oxyorthosilicate (GSO) crystals to 288 (36 x 8 array) 39-mm photomultiplier tubes in a hexagonal arrangement. The scanner operates only in 3-dimensional (3D) mode because there are no interplane septa. Performance measurements on the G-PET scanner were made following National Electrical Manufacturers Association NU 2-2001 procedures for most measurements, although NU 2-1994 procedures were used when these were considered more appropriate for a brain scanner (e.g., scatter fraction and counting-rate performance measurements). RESULTS: The transverse and axial resolutions near the center are 4.0 and 5.0 mm, respectively. At a radial offset of 10 cm, these numbers deteriorate by approximately 0.5 mm. The absolute sensitivity of this scanner measured with a 70-cm long line source is 4.79 counts per second (cps)/kBq. The scatter fraction measured with a line source in a 20-cm-diameter x 19-cm-long cylinder is 39% (for a lower energy threshold of 410 keV). For the same cylinder, the peak noise equivalent counting rate is 60 kcps at an activity concentration of 7.4 kBq/mL (0.20 micro Ci/mL), whereas the peak true coincidence rate is 132 kcps at an activity concentration of 14 kBq/mL (0.38 micro Ci/mL). Images from the Hoffman brain phantom as well as (18)F-FDG patient scans illustrate the high quality of images acquired on the G-PET scanner. CONCLUSION: The G-PET scanner attains the goal of high performance for brain imaging through the use of an Anger-logic GSO detector design with continuous optical coupling. This detector design leads to good energy resolution, which is needed in 3D imaging to minimize scatter and random coincidences.


Asunto(s)
Encéfalo/diagnóstico por imagen , Silicatos , Tomografía Computarizada de Emisión/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen , Control de Calidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
J Med Imaging Radiat Sci ; 45(4): 435-439, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31051916

RESUMEN

PURPOSE: This study developed and tested a novel scanner constructed for dedicated positron emission tomography (PET) of the breast. The breast PET (B-PET) scanner is designed with two opposing detectors using curve plate NaI(Tl) detectors to achieve a combination of high spatial resolution and energy resolution. METHODS: Phantom and clinical studies (n = 20) with 18F-fluorodeoxyglucose were carried out on the whole-body Philips Allegro scanner and the B-PET scanner. Images were subjectively assessed by an expert panel. RESULTS: Phantom studies indicated improved contrast for B-PET over conventional PET. Of the 20 clinical studies with breast cancer demonstrated on whole-body fluorodeoxyglucose PET, 10 B-PET scans showed agreement. Of the remaining 10 studies, three had breasts that were too small to be imaged, four had lesions that were too deep to be captured in the field of view, and three were excluded due to technical errors. CONCLUSIONS: Compared with conventional PET, B-PET images provided greater detail in breast lesions suggesting that the low-cost and relatively simple design of B-PET may potentially be an important adjunct to traditional mammography in helping determine the nature of a lesion.