Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(2)2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38257622

RESUMEN

Terahertz tomography is a promising method among non-destructive inspection techniques to detect faults and defects in dielectric samples. Recently, image quality was improved significantly through the incorporation of a priori information and off-axis data. However, this improvement has come at the cost of increased measurement time. To aim toward industrial applications, it is therefore necessary to speed up the measurement by parallelizing the data acquisition employing multi-channel setups. In this work, we present two tomographic frequency-modulated continuous wave (FMCW) systems working at a bandwidth of 230-320 GHz, equipped with an eight-channel detector array, and we compare their imaging results with those of a single-pixel setup. While in the first system the additional channels are used exclusively to detect radiation refracted by the sample, the second system features an f-θ lens, focusing the beam at different positions on its flat focal plane, and thus utilizing the whole detector array directly. The usage of the f-θ lens in combination with a scanning mirror eliminates the necessity of the formerly used slow translation of a single-pixel transmitter. This opens up the potential for a significant increase in acquisition speed, in our case by a factor of four to five, respectively.

2.
Sensors (Basel) ; 22(24)2022 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-36560062

RESUMEN

The field of terahertz and millimeter wave science and technology has evolved in recent years into an area attracting a lot of attention from all sides of science, industry, and the public [...].


Asunto(s)
Tecnología
3.
Sensors (Basel) ; 21(19)2021 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-34640889

RESUMEN

We present a rotational terahertz imaging system for inline nondestructive testing (NDT) of press sleeves for the paper industry during fabrication. Press sleeves often consist of polyurethane (PU) which is deposited by rotational molding on metal barrels and its outer surface mechanically processed in several milling steps afterwards. Due to a stabilizing polyester fiber mesh inlay, small defects can form on the sleeve's backside already during the initial molding, however, they cannot be visually inspected until the whole production processes is completed. We have developed a fast-scanning frequenc-modulated continuous wave (FMCW) terahertz imaging system, which can be integrated into the manufacturing process to yield high resolution images of the press sleeves and therefore can help to visualize hidden structural defects at an early stage of fabrication. This can save valuable time and resources during the production process. Our terahertz system can record images at 0.3 and 0.5 THz and we achieve data acquisition rates of at least 20 kHz, exploiting the fast rotational speed of the barrels during production to yield sub-millimeter image resolution. The potential of automated defect recognition by a simple machine learning approach for anomaly detection is also demonstrated and discussed.


Asunto(s)
Imágen por Terahertz , Aprendizaje Automático
4.
Sensors (Basel) ; 19(18)2019 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-31514296

RESUMEN

We present thickness measurements with millimeter and terahertz waves using frequency-modulated continuous-wave (FMCW) sensors. In contrast to terahertz time-domain spectroscopy (TDS), our FMCW systems provide a higher penetration depth and measurement rates of several kilohertz at frequency modulation bandwidths of up to 175 GHz. In order to resolve thicknesses below the Rayleigh resolution limit given by the modulation bandwidth, we employed a model-based signal processing technique. Within this contribution, we analyzed the influence of multiple reflections adapting a modified transfer matrix method. Based on a brute force optimization, we processed the models and compared them with the measured signal in parallel on a graphics processing unit, which allows fast calculations in less than 1 s. TDS measurements were used for the validation of our results on industrial samples. Finally, we present results obtained with reduced frequency modulation bandwidths, opening the window to future miniaturization based on monolithic microwave integrated circuit (MMIC) radar units.

5.
Sci Rep ; 14(1): 5534, 2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38448503

RESUMEN

We present observations of parasitic frequency components in the emission spectrum of typical photomixer sources for continuous wave (CW) terahertz generation. Broadband tunable photomixer systems are often used in combination with direct power detectors, e.g., for source and/or detector characterization. Here, spectral components besides the intended terahertz emission at the difference frequency of the two excitation lasers can significantly distort the measurement results. In this work, the appearance of parasitic mixing signals is observed in broadband measurements with a broadband antenna-coupled field-effect transistor as terahertz detector (TeraFET). The measurements reveal weaker spectral absorption features than expected and also a signal plateau towards higher frequencies, both strongly indicating a background in the detection signals. The photomixer emission is investigated in detail with a terahertz Fourier-transform infrared spectrometer (FTIR). We relate the observed parasitic frequency components with good quantitative agreement with the mode spectra of the semiconductor lasers. We also present one possible approach to overcome some of the issues, and we emphasize the importance of our findings to avoid distorted measurement results. To our knowledge, the essential aspect of parasitic mixing has so far been largely ignored in the literature where terahertz CW photomixer emitters are widely used for spectrally resolved measurements.

6.
Sci Rep ; 13(1): 11436, 2023 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-37454236

RESUMEN

The 3D range-migration algorithm (RMA) and its 2D equivalent, the omega-k algorithm, are employed in a wide range of applications where reconstruction of synthetic aperture data is required, from satellite radar imaging of planets over seismic imaging of the earth crust, down to phased-array ultrasound and ultrasonic application, and recently in-line synthetic aperture radar for non-destructive testing. These algorithms are based on Fourier transforms and share their time-complexity. This limits highly-resolved measurement data to be processed at high speeds which would be advantageous for modern production feed lines. In this publication, we present the development and implementation of the RMA on a quantum computer that scales favourably compared to the time complexity of the classical RMA. We compare reconstruction results of simulated and measured data of the classical and quantum RMA. Hereby, the quantum RMA is run on a quantum simulator backend as well as on IBM's Q System One quantum computer. The results show that real world applications and testing tasks may benefit from future quantum computers.


Asunto(s)
Algoritmos , Radar , Análisis de Fourier , Ultrasonografía/métodos , Transductores
7.
Opt Express ; 18(8): 8621-9, 2010 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-20588706

RESUMEN

We present difference-frequency stabilization of free-running distributed-feedback (DFB) diode lasers, maintaining a stable phase-lock to a local oscillator (LO) signal. The technique has been applied to coherent hybrid THz imaging which employs a high-power electronic radiation source emitting at 0.62 THz and electro-optic detectors. The THz radiation of the narrow-band emitter is mixed with the difference frequency of the DFB diode laser pair. The resulting intermediate frequency is phase-locked to the LO signal from a radio-frequency generator using a fast laser-current control loop. The stabilization scheme can be adapted readily to a wide range of applications which require stabilized laser beat-notes.

8.
Opt Lett ; 34(21): 3424-6, 2009 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-19881615

RESUMEN

We present a 64x48 pixel 2D electro-optical terahertz (THz) imaging system using a photonic mixing device time-of-flight camera as an optical demodulating detector array. The combination of electro-optic detection with a time-of-flight camera increases sensitivity drastically, enabling the use of a nonamplified laser source for high-resolution real-time THz electro-optic imaging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA