Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 11089, 2024 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750101

RESUMEN

This investigation explored the presence of microplastics (MPs) and artificial cellulosic particles (ACPs) in commercial water marketed in single use 1.5 L poly(ethylene terephthalate) bottles. In this work we determined a mass concentration of 1.61 (1.10-2.88) µg/L and 1.04 (0.43-1.82) µg/L for MPs and ACPs respectively in five top-selling brands from the Spanish bottled water market. Most MPs consisted of white and transparent polyester and polyethylene particles, while most ACPs were cellulosic fibers likely originating from textiles. The median size of MPs and ACPs was 93 µm (interquartile range 76-130 µm) and 77 µm (interquartile range 60-96 µm), respectively. Particle mass size distributions were fitted to a logistic function, enabling comparisons with other studies. The estimated daily intake of MPs due to the consumption of bottled water falls within the 4-18 ng kg-1 day-1 range, meaning that exposure to plastics through bottled water probably represents a negligible risk to human health. However, it's worth noting that the concentration of plastic found was much higher than that recorded for tap water, which supports the argument in favour of municipal drinking water.


Asunto(s)
Agua Potable , Microplásticos , Contaminantes Químicos del Agua , Microplásticos/análisis , Agua Potable/química , Agua Potable/análisis , España , Contaminantes Químicos del Agua/análisis , Celulosa/química , Celulosa/análisis , Humanos , Tamaño de la Partícula , Tereftalatos Polietilenos/química , Tereftalatos Polietilenos/análisis
2.
J Alzheimers Dis ; 93(1): 275-282, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36970902

RESUMEN

BACKGROUND: Alzheimer's disease (AD) biomarkers reflect key elements of pathophysiology and improve the diagnostic process. However, their use in routine clinical practice is still limited. OBJECTIVE: We aimed to assess neurologists' barriers and enablers to early AD diagnosis using core AD biomarkers. METHODS: We conducted an online study in collaboration with the Spanish Society of Neurology. Neurologists answered a survey exploring their attitudes towards AD diagnosis using biomarkers in mild cognitive impairment (MCI) or mild AD dementia. Multivariate logistic regression analyses were conducted to determine the association between neurologists' characteristics and diagnostic attitudes. RESULTS: We included 188 neurologists with a mean age (SD) of 40.6 (11.3) years, 52.7% male. Most participants had access to AD biomarkers, mainly in cerebrospinal fluid (CSF) (89.9%,#x0025;, n = 169). The majority of participants (95.2%,#x0025;, n = 179) considered CSF biomarkers useful for an etiological diagnosis in MCI. However, 85.6% of respondents (n = 161) used them in less than 60% of their MCI patients in routine clinical practice. Facilitating patients and their families to plan for the future was the most frequent enabler for the use of biomarkers. Short consultation time and practicalities associated with the programming of a lumbar puncture were the most common barriers. A younger neurologist age (p = 0.010) and a higher number of patients managed weekly (p = 0.036) were positively associated with the use of biomarkers. CONCLUSION: Most neurologists had a favorable attitude to the use of biomarkers, especially in MCI patients. Improvements in resources and consultation time may increase their use in routine clinical practice.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Humanos , Masculino , Femenino , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/líquido cefalorraquídeo , Neurólogos , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/líquido cefalorraquídeo , Biomarcadores/líquido cefalorraquídeo , Actitud , Péptidos beta-Amiloides/líquido cefalorraquídeo , Proteínas tau/líquido cefalorraquídeo , Progresión de la Enfermedad , Fragmentos de Péptidos/líquido cefalorraquídeo
3.
Water Res ; 238: 120044, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37156103

RESUMEN

The purpose of this study was to investigate the occurrence of microplastics (MPs) in drinking water in Spain by comparing tap water from different locations using common sampling and identification procedures. We sampled tap water from 24 points in 8 different locations from continental Spain and the Canary Islands by means of 25 µm opening size steel filters coupled to household connections. All particles were measured and spectroscopically characterized including not only MPs but also particles consisting of natural materials with evidence of industrial processing, such as dyed natural fibres, referred insofar as artificial particles (APs). The average concentration of MPs was 12.5 ± 4.9 MPs/m3 and that of anthropogenic particles 32.2 ± 12.5 APs/m3. The main synthetic polymers detected were polyamide, polyester, and polypropylene, with lower counts of other polymers including the biopolymer poly(lactic acid). Particle size and mass distributions were parameterized by means of power law distributions, which allowed performing estimations of the concentration of smaller particles provided the same scaling parameter of the power law applies. The calculated total mass concentration of the identified MPs was 45.5 ng/L. The observed size distribution of MPs allowed an estimation for the concentration of nanoplastics (< 1 µm) well below the ng/L range; higher concentrations are not consistent with scale invariant fractal fragmentation. Our findings showed that MPs in the drinking water sampled in this work do not represent a significant way of exposure to MPs and would probably pose a negligible risk for human health.


Asunto(s)
Agua Potable , Contaminantes Químicos del Agua , Humanos , Microplásticos , Plásticos , Agua Potable/análisis , España , Ciudades , Contaminantes Químicos del Agua/análisis , Monitoreo del Ambiente , Polímeros
4.
Eur J Pharm Sci ; 161: 105791, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33691154

RESUMEN

Panama, like most Latin American countries, has insufficient regulatory safeguards to ensure the safety and efficacy of all pharmaceutical products in the market, a situation that results in a two-tier system, where affluent citizens can afford innovator products while poor citizens must consume 'generics' of uncertain quality. Given that one lot of each drug product is analyzed every five years during registration while commercial lots are not, and since most products are not bioequivalent but simply copies or similars, there is a concern that commercial and registration lots of these 'generics' may not be of the same quality. The objective of this study was to assess the ability of various in vitro quality control tests to detect difference among five amlodipine products available in the Panamanian market: four 'generics', made in various countries, and the innovator, made in Germany and used as reference listed drug in Panama (Pan-RLD). The innovator manufactured in the United States (US-RLD) was used to compare the two RLDs. The Content Uniformity test, 30-min Dissolution test and multiple-pH Dissolution Profiles did not show any difference among the products. However, the in vitro dissolution absorption system 1 (IDAS1) showed a statistically significant difference in the amount dissolved between Pan-RLD and three out of the four 'generics', and significantly lower permeated amount for all the 'generics' compared with Pan-RLD; only US-RLD was similar to Pan-RLD. Thus, IDAS1 showed promise as a potential tool that authorities in weakly regulated markets can use to monitor for possible lot-to-lot product changes, which can help improve the quality of pharmaceutical products available to their entire populations. The significance of the similarity between the innovators made in Germany and the United States and their difference from the 'generics' (manufactured in other countries) is not known but deserves investigation.


Asunto(s)
Amlodipino , Medicamentos Genéricos , Control de Calidad , Solubilidad , Equivalencia Terapéutica , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA