Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Methods ; 224: 1-9, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38295891

RESUMEN

The Major Histocompatibility Complex (MHC) is a critical element of the vertebrate cellular immune system, responsible for presenting peptides derived from intracellular proteins. MHC-I presentation is pivotal in the immune response and holds considerable potential in the realms of vaccine development and cancer immunotherapy. This study delves into the limitations of current methods and benchmarks for MHC-I presentation. We introduce a novel benchmark designed to assess generalization properties and the reliability of models on unseen MHC molecules and peptides, with a focus on the Human Leukocyte Antigen (HLA)-a specific subset of MHC genes present in humans. Finally, we introduce HLABERT, a pretrained language model that outperforms previous methods significantly on our benchmark and establishes a new state-of-the-art on existing benchmarks.


Asunto(s)
Péptidos , Proteínas , Humanos , Reproducibilidad de los Resultados , Péptidos/química , Proteínas/metabolismo , Complejo Mayor de Histocompatibilidad/genética , Unión Proteica
2.
Anal Chem ; 96(9): 3763-3771, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38373058

RESUMEN

This study introduces a simplified purification method for analyzing 82Se/78Se isotope ratios in diverse natural samples using hydride generation MC-ICP-MS. Unlike the thiol resin method, which is time-consuming and sensitive to the concentrations of reagents used at individual stages, our proposed alternative is quicker, simpler, and robust. The procedure involves coprecipitation of selenium with iron hydroxide and dissolution in hydrochloric acid. Combining hydride generation and a second cleanup stage achieves sufficient purification for Se isotope ratio measurements. The method is efficient, taking 3-4 h after sample decomposition, utilizing common reagents [HCl, Fe(NO3)3, NH4Cl] without evaporation or clean lab conditions. Results on 82Se/78Se isotope ratios in various matrices are presented, comparing them with literature data. All isotopic results have been subjected to a newly proposed state-of-the-art approach to uncertainty estimation dedicated to isotope ratio measurements. The approach is based on applying Monte Carlo simulations with consideration of different samples' results normalized by the expected value. By doing that, we obtained estimated uncertainty for any Se sample with the influence of particular measurements on the final estimation included. We employ a Monte Carlo simulation-based uncertainty estimation approach for isotope ratio measurements, providing estimated uncertainty for each selenium sample.

3.
Anal Chem ; 96(1): 188-196, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38117933

RESUMEN

1H NMR spectroscopy is a powerful tool for analyzing mixtures including determining the concentrations of individual components. When signals from multiple compounds overlap, this task requires computational solutions. They are typically based on peak-picking and the comparison of obtained peak lists with libraries of individual components. This can fail if peaks are not sufficiently resolved or when peak positions differ between the library and the mixture. In this paper, we present Magnetstein, a quantification algorithm rooted in the optimal transport theory that makes it robust to unexpected frequency shifts and overlapping signals. Thanks to this, Magnetstein can quantitatively analyze difficult spectra with the estimation trueness an order of magnitude higher than that of commercial tools. Furthermore, the method is easier to use than other approaches, having only two parameters with default values applicable to a broad range of experiments and requiring little to no preprocessing of the spectra.

4.
Anal Chem ; 96(23): 9343-9352, 2024 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-38804718

RESUMEN

Oligonucleotide therapeutics have emerged as an important class of drugs offering targeted therapeutic strategies that complement traditional modalities, such as monoclonal antibodies and small molecules. Their unique ability to precisely modulate gene expression makes them vital for addressing previously undruggable targets. A critical aspect of developing these therapies is characterizing their molecular composition accurately. This includes determining the monoisotopic mass of oligonucleotides, which is essential for identifying impurities, degradants, and modifications that can affect the drug efficacy and safety. Mass spectrometry (MS) plays a pivotal role in this process, yet the accurate interpretation of complex mass spectra remains challenging, especially for large molecules, where the monoisotopic peak is often undetectable. To address this issue, we have adapted the MIND algorithm, originally developed for top-down proteomics, for use with oligonucleotide data. This adaptation allows for the prediction of monoisotopic mass from the more readily detectable, most-abundant peak mass, enhancing the ability to annotate complex spectra of oligonucleotides. Our comprehensive validation of this modified algorithm on both in silico and real-world oligonucleotide data sets has demonstrated its effectiveness and reliability. To facilitate wider adoption of this advanced analytical technique, we have encapsulated the enhanced MIND algorithm in a user-friendly Shiny application. This online platform simplifies the process of annotating complex oligonucleotide spectra, making advanced mass spectrometry analysis accessible to researchers and drug developers. The application is available at https://valkenborg-lab.shinyapps.io/mind4oligos/.


Asunto(s)
Algoritmos , Espectrometría de Masas , Oligonucleótidos , Oligonucleótidos/análisis , Espectrometría de Masas/métodos , Peso Molecular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA