Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Radiol ; 34(8): 5190-5200, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38183450

RESUMEN

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.


Asunto(s)
Aorta Torácica , Disección Aórtica , Hemodinámica , Trombosis , Humanos , Masculino , Femenino , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Disección Aórtica/complicaciones , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/fisiopatología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Angiografía por Tomografía Computarizada/métodos , Enfermedad Crónica , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/complicaciones , Angiografía por Resonancia Magnética/métodos
2.
J Cardiovasc Magn Reson ; : 101088, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39214465

RESUMEN

OBJECTIVES: Patients with syndromic heritable thoracic aortic diseases (sHTAD) who underwent prophylactic aortic root replacement are at high risk of distal aortic events, but the underlying mechanisms are poorly understood. This prospective, longitudinal study aims to assess the impact of valve-sparing aortic root replacement (VSARR) on aortic fluid dynamics and biomechanics in these patients, and to examine whether they present altered haemodynamics or biomechanics prior to surgery compared to sHTAD patients with no indication for surgery (sHTAD-NSx) and healthy volunteers (HV). METHODS: Sixteen patients with Marfan or Loeys-Dietz syndrome underwent two 4D flow CMR studies before (sHTAD-preSx) and after VSARR (sHTAD-postSx). Two age, sex and BSA matched cohorts of 40 HV and 16 sHTAD-NSx patients with available 4D flow CMR, were selected for comparison. In-plane rotational flow (IRF), systolic flow reversal ratio (SFRR), wall shear stress (WSS), pulse wave velocity (PWV) and aortic strain were analysed in the ascending (AscAo) and descending aorta (DescAo). RESULTS: All patients with sHTAD presented altered haemodynamics and increased aortic stiffness (p<0.05) compared to HV, both in the AscAo (median PWV 7.4 in sHTAD-NSx; 6.8 in sHTAD-preSx; 4.9m/s in HV) and DescAo (median PWV 9.1 in sHTAD-NSx; 8.1 in sHTAD-preSx; 6.3m/s in HV). Patients awaiting VSARR had markedly reduced in-plane (median IRF -2.2 vs 10.4 cm2/s in HV, p=0.001), but increased through-plane flow rotation (median SFRR 7.8 vs 3.8% in HV, p=0.002), and decreased WSS (0.36 vs 0.47N/m2 in HV, p=0.004) in the proximal DescAo. After VSARR, proximal DescAo in-plane rotational flow (p=0.010) and circumferential WSS increased (p=0.011), no longer differing from HV, but through-plane rotational flow, axial WSS and stiffness remained altered. Patients in which aortic tortuosity was reduced after surgery showed greater post-surgical increase in IRF compared to those in which tortuosity increased (median IRF increase 18.1 vs 3.3cm²/s, p=0.047). Most AscAo flow alterations were restored to physiological values after VSARR. CONCLUSIONS: In patients with sHTAD, VSARR partially restores downstream fluid dynamics to physiological levels. However, some flow disturbances and increased stiffness persist in the proximal DescAo. Further longitudinal studies are needed to evaluate whether persistent alterations contribute to post-surgical risk.

3.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38211655

RESUMEN

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.


Asunto(s)
Aorta Torácica , Enfermedades de la Aorta , Medios de Contraste , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Aorta Torácica/diagnóstico por imagen , Anciano , Medios de Contraste/administración & dosificación , Enfermedades de la Aorta/diagnóstico por imagen , Técnicas de Imagen Sincronizada Respiratorias , Adulto , Factores de Tiempo , Interpretación de Imagen Asistida por Computador , Técnicas de Imagen Sincronizada Cardíacas
4.
Eur Radiol ; 32(10): 7117-7127, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35976395

RESUMEN

OBJECTIVE: Three-dimensional (3D) time-resolved phase-contrast cardiac magnetic resonance (4D flow CMR) allows for unparalleled quantification of blood velocity. Despite established potential in aortic diseases, the analysis is time-consuming and requires expert knowledge, hindering clinical application. The present research aimed to develop and test a fully automatic machine learning-based pipeline for aortic 4D flow CMR analysis. METHODS: Four hundred and four subjects were prospectively included. Ground-truth to train the algorithms was generated by experts. The cohort was divided into training (323 patients) and testing (81) sets and used to train and test a 3D nnU-Net for segmentation and a Deep Q-Network algorithm for landmark detection. In-plane (IRF) and through-plane (SFRR) rotational flow descriptors and axial and circumferential wall shear stress (WSS) were computed at ten planes covering the ascending aorta and arch. RESULTS: Automatic aortic segmentation resulted in a median Dice score (DS) of 0.949 and average symmetric surface distance of 0.839 (0.632-1.071) mm, comparable with the state of the art. Aortic landmarks were located with a precision comparable with experts in the sinotubular junction and first and third supra-aortic vessels (p = 0.513, 0.592 and 0.905, respectively) but with lower precision in the pulmonary bifurcation (p = 0.028), resulting in precise localisation of analysis planes. Automatic flow assessment showed excellent (ICC > 0.9) agreement with manual quantification of SFRR and good-to-excellent agreement (ICC > 0.75) in the measurement of IRF and axial and circumferential WSS. CONCLUSION: Fully automatic analysis of complex aortic flow dynamics from 4D flow CMR is feasible. Its implementation could foster the clinical use of 4D flow CMR. KEY POINTS: • 4D flow CMR allows for unparalleled aortic blood flow analysis but requires aortic segmentation and anatomical landmark identification, which are time-consuming, limiting 4D flow CMR widespread use. • A fully automatic machine learning pipeline for aortic 4D flow CMR analysis was trained with data of 323 patients and tested in 81 patients, ensuring a balanced distribution of aneurysm aetiologies. • Automatic assessment of complex flow characteristics such as rotational flow and wall shear stress showed good-to-excellent agreement with manual quantification.


Asunto(s)
Aorta , Imagen por Resonancia Magnética , Aorta/diagnóstico por imagen , Válvula Aórtica , Velocidad del Flujo Sanguíneo , Humanos , Aprendizaje Automático , Imagen por Resonancia Magnética/métodos
5.
J Cardiovasc Magn Reson ; 24(1): 20, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-35346239

RESUMEN

BACKGROUND: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. METHODS: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. RESULTS: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. CONCLUSIONS: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Rigidez Vascular , Disección Aórtica/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso
6.
Artículo en Inglés | MEDLINE | ID: mdl-37490995

RESUMEN

BACKGROUND: Blunt traumatic thoracic aortic injuries (BTAIs) are associated with a high mortality rate. Thoracic endovascular aortic repair (TEVAR) is the most frequently used surgical strategy in patients with BTAI, as it offers good short- and middle-term results. Previous studies have reported an abnormally high prevalence of hypertension (HT) in these patients. This work aimed to describe the long-term prevalence of HT and provide a comprehensive evaluation of the biomechanical, clinical, and functional factors involved in HT development. METHODS: Twenty-six patients treated with TEVAR following BTAI with no history of HT at the time of trauma were enrolled. They were matched with 37 healthy volunteers based on age, sex, and body surface area and underwent a comprehensive follow-up study, including cardiovascular magnetic resonance, 24-hour ambulatory blood pressure monitoring, and assessment of carotid-femoral pulse wave velocity (cfPWV, a measure of aortic stiffness) and flow-mediated vasodilation. RESULTS: The mean patient age was 43.5 ± 12.9 years, and the majority were male (23 of 26; 88.5%). At a mean of 120.2 ± 69.7 months after intervention, 17 patients (65%) presented with HT, 14 (54%) had abnormal nighttime blood pressure dipping, and 6 (23%) high cfPWV. New-onset HT was related to a more proximal TEVAR landing zone and greater distal oversizing. Abnormal nighttime blood pressure was related to high cfPWV, which in turn was associated with TEVAR length and premature arterial aging. CONCLUSIONS: HT frequently occurs otherwise healthy subjects undergoing TEVAR implantation after BTAI. TEVAR stiffness and length, the proximal landing zone, and distal oversizing are potentially modifiable surgical characteristics related to abnormal blood pressure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA