RESUMEN
INTRODUCTION: Radiofrequency ablation (RFA) for atrial fibrillation (AF) has been associated with variable incidence (0.88%-10%) of pericarditis manifested as chest pain, possibly more prevalent with the advent of high-power short-duration (HPSD) ablation. This has led to the widespread use of colchicine in preventative protocols for postablation pericarditis. However, the efficacy of preventative colchicine has not been validated yet. OBJECTIVE: To evaluate the efficacy of a routine postoperative colchicine regimen (0.6 mg twice a day for 14 days post-AF ablation) for prevention of postablation pericarditis in patients undergoing HPSD ablation. METHOD: We retrospectively evaluated consecutive single-operator HPSD AF ablation procedures at our institution from June 2019 to July 2022. A colchicine protocol was introduced in June 2021 for the prevention of postablation pericarditis. All ablations were performed with 50 watts. Patients were divided into colchicine and noncolchicine groups. We recorded incidence of postablation chest pain, emergency room (ER) visit for chest pain, pericardial effusion, pericardiocentesis, any ER visit, hospitalization, AF recurrence, and cardioversion for AF within the first 30 days following ablation. We also recorded colchicine-related side effects and medication compliance. RESULTS: Two hundred and ninety-four consecutive HPSD AF ablation patients were screened for the study. After implementing the prespecified exclusion criteria, a total of 205 patients were included in the final analysis, yielding 101 patients in the colchicine group and 104 patients in the noncolchicine group. Both groups were well-matched for demographic and procedural parameters. There was no significant difference in postablation chest pain (9.9% vs. 8.6%, p = .7), pericardial effusion (2.9% vs. 0.9%, p = .1), ER visits (11.9% vs. 12.5%, p = .2), 30-day hospitalization for AF recurrence (0.9% vs. 0.96%, p = .3), and 30-day need for cardioversion for AF (3.9% vs. 5.7%, p = .2). Fifteen (15) patients had severe colchicine-related diarrhea, out of which 12 discontinued it prematurely. There were no major procedural complications in either group. CONCLUSION: In this single-operator retrospective analysis, prophylactic colchicine was not associated with significant reduction in the incidence of postablation chest pain, pericarditis, 30 day hospitalization, ER visits, or AF recurrence or need of cardioversion within first 30 days after HPSD ablation for AF. However, its usage was associated with significant diarrhea. This study concludes no additional advantage of prophylactic use of colchicine after HPSD AF ablation.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Derrame Pericárdico , Pericarditis , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Colchicina/efectos adversos , Estudios Retrospectivos , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/epidemiología , Derrame Pericárdico/etiología , Resultado del Tratamiento , Pericarditis/diagnóstico , Pericarditis/prevención & control , Pericarditis/epidemiología , Diarrea/tratamiento farmacológico , Diarrea/etiología , Diarrea/cirugía , Dolor en el Pecho/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Venas Pulmonares/cirugíaRESUMEN
BACKGROUND: Radiofrequency catheter ablation (RFA) for atrial fibrillation (AF) is being increasingly performed without fluoroscopy. This study aims to determine the safety of fluoroless RFA for patients with pre-existing cardiac implantable electronic devices (CIED). METHODS: This is a single-center, single-operator, retrospective, observational study of 225 consecutive fluoroless RFA procedures for AF from June 1, 2019 to June 1, 2022. All procedures were performed with intracardiac echocardiography (ICE) support. Patients with pre-existing CIED were extracted from the database. Each CIED was interrogated at the start and end of each procedure and at 30-day follow-up. Pre- and post-procedure CIED interrogations were compared for any change in device or lead parameters. Patients were tracked for any subsequent device malfunction. RESULTS: Out of 225 fluoroless AF ablations, 25 (10.2%) had pre-existing CIED (14 dual-chamber pacemakers, three dual-chamber defibrillators, three single-chamber defibrillators, one single chamber pacemaker, and four biventricular devices). Mean patient age was 71 ± 6 years. The mean duration of indwelling CIED was 1804 ± 1645 days (range: 78-6267 days). One (4%) patient had lead-related fibrin on ICE imaging. There was no significant difference in lead(s) threshold, impedance, or sensing post procedure or at 30-day follow-up compared to pre procedure. None of the patients required lead revision. There were no intra- or post-op thromboembolic events or subsequent device infection. One patient underwent CIED extraction after 11 months for an unrelated secondary device infection. CONCLUSIONS: Radiofrequency catheter ablation for AF can be safely performed without fluoroscopy in patients with pre-existing CIED.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Desfibriladores Implantables , Humanos , Anciano , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Ablación por Catéter/métodosRESUMEN
BACKGROUND: Magnetic resonance imaging (MRI) in patients with MRI-conditional cardiovascular implantable electronic devices (CIED) remain a logistical issue for device programming during the scan. In current practice, a trained person needs to be present on-site to program CIED for MRI scan. This can cause delay in patient care, rescheduling of tests and increase healthcare costs. A novel remote programming (RP) strategy can be utilized to reprogram the CIED remotely. We sought to explore the feasibility and safety of RP of CIEDs in patients undergoing MRI scan. METHODS: We implemented the Medtronic CIED RP software at our institution after ensuring HIPAA compliance. The MRI technician started the session by contacting an off-site remote operator and placing a programmer wand from the 2090 Medtronic programmer over the CIED. The remote operator logged into a remote access software and provided a unique access code to the MRI technician. After entering the access code into the programmer, the remote operator was able to program the device as needed. We conducted a periodic audit of the first 209 patients who underwent RP of CIEDs for MRI. Outcomes analyzed were successful completion of RP sessions and time saved per scan. RESULTS: Of the 209 MRI scans, 51 scans were performed urgently. There were no connectivity and programming problems or need for MRI rescheduling. In-person reprogramming was not required for any patient. All scans were completed safely in a timely manner, and there were no reports of CIED malfunction. Time saved per scan was estimated to be 28 ± 10 min. CONCLUSIONS: Remote programming of CIEDs for MRI scans is a safe and effective strategy.
Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Electrónica , Humanos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodosRESUMEN
Cross stimulation is defined as stimulation of one cardiac chamber when the stimulation of the other chamber is expected. We present a case of an eighty three year old patient with history of dual chamber pacemaker implantation with recent generator change which showed interesting ECG findings.
Asunto(s)
Electrocardiografía , Marcapaso Artificial , Anciano de 80 o más Años , Estimulación Cardíaca Artificial , Ventrículos Cardíacos/diagnóstico por imagen , HumanosRESUMEN
Pepper spray is used as a crowd control agent and for self-defense. It has been thought to be safe; however, 27 persons have died in police custody after exposure to pepper spray. We report on a 21-year-old man, with no underlying heart disease and a normal ECG and echocardiogram in the past, who was pepper sprayed and developed ventricular fibrillation. An admission ECG showed marked ST segment elevation but subsequent coronary arteriography was normal. We hypothesize that pepper spray triggered coronary spasm, resulting in ventricular fibrillation. This report adds to a body of information that pepper spray is dangerous.
Asunto(s)
Capsaicina/envenenamiento , Cardiomiopatía Hipertrófica/terapia , Vasoespasmo Coronario/inducido químicamente , Desfibriladores Implantables , Fibrilación Ventricular/inducido químicamente , Aerosoles , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Reanimación Cardiopulmonar , Ecocardiografía , Electrocardiografía , Humanos , Imagen por Resonancia Magnética , Masculino , Adulto JovenRESUMEN
INTRODUCTION: The impact of cardioneuroablation (CNA) on ventricular repolarization by using corrected QT interval (QTc) measurements has been recently demonstrated. The effects of cardiac pacing (CP) on ventricular repolarization have not been studied in patients with vasovagal syncope (VVS). We sought to compare ventricular repolarization effects of CNA (group 1) with CP (group 2) in patients with VVS. METHODS: We enrolled 69 patients with age 38 ± 13 years (53.6% male), n = 47 in group 1 and n = 22 in group 2. Clinical diagnosis of cardioinhibitory type was supported by cardiac monitoring or tilt testing. QTc was calculated at baseline (time-1), at 24 h after ablation (time-2), and at 9-12 months (time-3) in the follow-up. RESULTS: In the group 1, from time-1 to time-2, a significant shortening in QTcFredericia (from 403 ± 27 to 382 ± 27 ms, p < 0.0001), QTcFramingham (from 402 ± 27 to 384 ± 27 ms, p < 0.0001), and QTcHodges (from 405 ± 26 to 388 ± 24 ms, p < 0.0001) was observed which remained lower than baseline in time-3 (373 ± 29, 376 ± 27, and 378 ± 27 ms, respectively). Although the difference between measurements in time-1 and time-2 was not statistically significant for QTcBazett, a significant shortening was detected between time-1 and time-3 (from 408 ± 30 to 394 ± 33, p = 0.005). In the group 2, there was no time-based changes on QTc measurements. In the linear mixed model analysis, the longitudinal reduction tendency in the QTcFredericia and QTcFramingham was more pronounced in group 1. CONCLUSIONS: Our results demonstrate that CNA reduces QTc levels through neuromodulation effect whereas CP has no effect on ventricular repolarization in patients with VVS.
Asunto(s)
Ablación por Catéter , Síncope Vasovagal , Adulto , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Síncope Vasovagal/cirugía , Pruebas de Mesa InclinadaRESUMEN
BACKGROUND: Although large randomized clinical trials have found that primary prevention use of an implantable cardioverter-defibrillator (ICD) improves survival in patients with cardiomyopathy and heart failure symptoms, patients who receive ICDs in practice are often older and have more comorbidities than patients who were enrolled in the clinical trials. In addition, there is a debate among clinicians on the usefulness of electrophysiological study for risk stratification of asymptomatic patients with Brugada syndrome. AIM: Our analysis has 2 objectives. First, to evaluate whether ventricular arrhythmias (VAs) induced with programmed electrostimulation in asymptomatic patients with Brugada syndrome identify a higher risk group that may require additional testing or therapies. Second, to evaluate whether implantation of an ICD is associated with a clinical benefit in older patients and patients with comorbidities who would otherwise benefit on the basis of left ventricular ejection fraction and heart failure symptoms. METHODS: Traditional statistical approaches were used to address 1) whether programmed ventricular stimulation identifies a higher-risk group in asymptomatic patients with Brugada syndrome and 2) whether ICD implantation for primary prevention is associated with improved outcomes in older patients (>75 years of age) and patients with significant comorbidities who would otherwise meet criteria for ICD implantation on the basis of symptoms or left ventricular function. RESULTS: Evidence from 6 studies of 1138 asymptomatic patients were identified. Brugada syndrome with inducible VA on electrophysiological study was identified in 390 (34.3%) patients. To minimize patient overlap, the primary analysis used 5 of the 6 studies and found an odds ratio of 2.3 (95% CI: 0.63-8.66; P=0.2) for major arrhythmic events (sustained VAs, sudden cardiac death, or appropriate ICD therapy) in asymptomatic patients with Brugada syndrome and inducible VA on electrophysiological study versus those without inducible VA. Ten studies were reviewed that evaluated ICD use in older patients and 4 studies that evaluated unique patient populations were identified. In our analysis, ICD implantation was associated with improved survival (overall hazard ratio: 0.75; 95% confidence interval: 0.67-0.83; P<0.001). Ten studies were identified that evaluated ICD use in patients with various comorbidities including renal disease, chronic obstructive pulmonary disease, atrial fibrillation, heart disease, and others. A random effects model demonstrated that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.72; 95% confidence interval: 0.65-0.79; P<0.0001), and a second "minimal overlap" analysis also found that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.61-0.82; P<0.0001). In 5 studies that included data on renal dysfunction, ICD implantation was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.60-0.85; P<0.001).
Asunto(s)
Cardiología/normas , Muerte Súbita Cardíaca/prevención & control , Guías de Práctica Clínica como Asunto/normas , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Complejos Prematuros Ventriculares/terapia , American Heart Association , Consenso , Medicina Basada en la Evidencia/normas , Humanos , Factores de Riesgo , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Resultado del Tratamiento , Estados Unidos , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/mortalidad , Complejos Prematuros Ventriculares/complicaciones , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/mortalidadRESUMEN
BACKGROUND: The utility of protamine sulfate for heparin reversal in catheter-based atrial fibrillation (AF) ablation is unclear when using the suture closure technique for vascular hemostasis. OBJECTIVE: This study sought to address if protamine sulfate use for heparin reversal reduces vascular access complications in AF catheter ablation when suture techniques are used for postprocedural vascular hemostasis. METHODS: This is a retrospective multicenter observational study of 294 consecutive patients who underwent catheter ablation for AF with subsequent vascular access hemostasis by means of a figure-of-eight suture or stopcock technique. A total of 156 patients received protamine for heparin reversal before sheath removal while 138 patients did not receive protamine. The two groups were compared for procedural activated clotting time (ACT), access site complications, and duration of hospital stay. RESULTS: Baseline demographic characteristics were comparable in both groups. Despite higher ACT before venous sheath removal in patients not receiving protamine (288.0 ± 44.3 vs 153.9 ± 32.0 seconds; P < .001), there was no significant difference in groin complications, postoperative thromboembolic events, or duration of hospital stay between the two groups. Suture failure requiring manual compression was rarely observed in this cohort (0.34%). CONCLUSION: With modern vascular access and sheath management techniques, for patients undergoing catheter ablation for AF, simple suture closure techniques can obviate the need for protamine administration to safely achieve hemostasis after removal of vascular sheaths.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Hemorragia/prevención & control , Hemostasis , Antagonistas de Heparina/uso terapéutico , Heparina/uso terapéutico , Protaminas/uso terapéutico , Técnicas de Sutura , Potenciales de Acción , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Frecuencia Cardíaca , Hemorragia/sangre , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Heparina/efectos adversos , Antagonistas de Heparina/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Protaminas/efectos adversos , Estudios Retrospectivos , Técnicas de Sutura/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Adulto JovenRESUMEN
BACKGROUND: Atrial arrhythmias (AA), including atrial fibrillation (AF), have been reported in patients after cavotricuspid isthmus (CTI) ablation for typical atrial flutter (AFL). Several studies have examined the effect of performing concomitant pulmonary vein isolation (PVI) with CTI on recurrent AA. These studies were analyzed to determine the overall effect of this approach on recurrent AA. METHODS: PubMed and Google Scholar were searched for randomized trials comparing the incidence of AA after CTI versus CTI + PVI until June 2018. Only patients without prior history of AF were included in the recurrent AA analysis. All patients were included in the analyses of other clinical outcomes. RESULTS: Four randomized control trials were included in the meta-analysis. In the recurrent AA analysis, a total of 314 patients were randomized in the studies (n = 158 CTI, n = 156 CTI + PVI). Freedom from AA at 1 year was significantly higher in the CTI + PVI group versus CTI alone (odds ratio [OR] 0.25 [0.14, 0.44] 95% confidence interval [CI], P < 0.00001). A total of 550 patients (n = 336 CTI, n = 214 CTI + PVI) were included in analyses for procedure time, fluoroscopy time, and complications rates. Procedure time and fluoroscopy time were significantly longer in the CTI + PVI group (mean difference [MD]: 103.31 min [94.40, 112.23] 95% CI, P < 0.00001) and (MD: 16.47 min [14.89, 18.05] 95% CI, P < 0.00001), respectively. Total complications were statistically similar between groups. CONCLUSION: This meta-analysis shows addition of a prophylactic PVI during CTI ablation significantly reduces recurrent AA at 1 year without significantly increasing major complications.
Asunto(s)
Fibrilación Atrial/prevención & control , Aleteo Atrial/cirugía , Complicaciones Posoperatorias/prevención & control , Venas Pulmonares/cirugía , Válvula Tricúspide/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter , Humanos , Complicaciones Posoperatorias/etiología , Ensayos Clínicos Controlados Aleatorios como Asunto , RecurrenciaRESUMEN
Left ventricular diverticula (LVD) are rare congenital anomalies usually detected incidentally in the adult population. Most commonly, they are found as a single left ventricular diverticulum in association with other congenital abnormalities but multiple LVD are exceedingly rare. We are describing a patient who was found to have multiple LVD on multimodality imaging studies. He had presented with a sudden cardiac arrest attributed to a combination of alcohol intoxication and QT interval prolongation from hypokalemia and antidepressant medications. The patient was managed conservatively and discharged with an implantable loop recorder for detecting any occult arrhythmias.
Asunto(s)
Divertículo/diagnóstico por imagen , Ecocardiografía/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana EdadRESUMEN
Persistent inflammation promotes development and progression of heart failure (HF). TWEAK (TNF-Related WEAK Inducer Of Apoptosis), a NF-κB- and/or AP-1-responsive proinflammatory cytokine that signals via TWEAK receptor (TWEAKR), is expressed at high levels in human and preclinical models of HF. Since the adapter molecule TRAF3IP2 (TRAF3 Interacting Protein 2) is an upstream regulator of various proinflammatory pathways, including those activated by NF-κB and AP-1, we hypothesized that targeting TRAF3IP2 inhibits TWEAK-induced proinflammatory and pro-fibrotic responses in vitro and in vivo. Consistent with the hypothesis, forced expression of TRAF3IP2 upregulated TWEAK and its receptor expression in cultured adult mouse cardiac fibroblasts (CF). Further, exogenous TWEAK upregulated TRAF3IP2 expression in a time- and dose-dependent manner, suggesting a positive-feedback regulation of TRAF3IP2 and TWEAK. TWEAK also promoted TRAF3IP2 nuclear translocation. Confirming its critical role in TWEAK signaling, silencing TRAF3IP2 inhibited TWEAK autoregulation, TWEAKR upregulation, p38 MAPK, NF-κB and AP-1 activation, inflammatory cytokine expression, MMP and TIMP1 activation, collagen expression and secretion, and importantly, proliferation and migration. Recapitulating these in vitro results, continuous infusion of TWEAK for 7â¯days increased systolic blood pressure (SBP), upregulated TRAF3IP2 expression, activated p38 MAPK, NF-κB and AP-1, induced the expression of multiple proinflammatory and pro-fibrotic mediators, and interstitial fibrosis in hearts of wild type mice. These proinflammatory and pro-fibrotic changes occurred in conjunction with myocardial hypertrophy and contractile dysfunction. Importantly, genetic ablation of TRAF3IP2 inhibited these TWEAK-induced adverse cardiac changes independent of increases in SBP, indicating that TRAF3IP2 plays a causal role, and thus a therapeutic target, in chronic inflammatory and fibro-proliferative diseases.
Asunto(s)
Proteínas Adaptadoras Transductoras de Señales/genética , Citocina TWEAK/genética , Insuficiencia Cardíaca/genética , Inflamación/genética , Receptor de TWEAK/genética , Animales , Presión Sanguínea/genética , Movimiento Celular/genética , Proliferación Celular/genética , Fibroblastos/patología , Regulación de la Expresión Génica/genética , Corazón/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Humanos , Inflamación/fisiopatología , Ratones , FN-kappa B/genética , Transducción de Señal/genética , Factor de Transcripción AP-1/genética , Proteínas Quinasas p38 Activadas por Mitógenos/genéticaRESUMEN
BACKGROUND: Figure-of-eight sutures (F8S) have emerged as an alternative to the standard practice of manual compression to achieve venous hemostasis after catheter ablation for atrial fibrillation (AF). In lieu of a knot to secure the sutures in place, a three-way stopcock can be used, which can be loosened or tightened as needed to achieve hemostasis and is easier to remove. The safety and effectiveness of this technique, when compared to traditional F8S, are unknown. In this case series, we sought to describe this stopcock closure (SC) technique and compare procedural characteristics and outcomes to the traditional F8S. METHODS: Charts of consecutive patients who underwent AF radiofrequency at two centers were reviewed for the type of hemostasis (SC or F8S), demographics, periprocedural anticoagulation, groin complications, and procedural duration. RESULTS: A total of 100 patients were included (50 in the F8S group and 50 in the SC group). The two groups were similar in terms of mean age, gender, weight, renal function, oral anticoagulant use, and procedural heparin dosing. There was one groin bleeding complication in each group. The procedural time was shortened in the SC group (220 ± 8 minutes vs 313 ± 8 minutes), and there was more protamine use (25 vs 3 patients) owing to the differences in preferences among two operators. CONCLUSION: In this proof-of-concept study, a simple stopcock device provided comparable hemostasis to standard F8S after radiofrequency catheter ablation of AF.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Hemostáticas , Prueba de Estudio Conceptual , Técnicas de Sutura , Anciano , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana EdadRESUMEN
INTRODUCTION: The rates of cardiac implantable electronic device (CIED) infections have risen over the past decade and are associated with increased hospitalizations and mortality. A number of preventative strategies have been developed including an antibiotic coated envelope, but it has yet to gain widespread use. METHODS: A meta-analysis was performed on controlled studies of the antibiotic envelope. PubMed and Google Scholar were searched for studies comparing infection rates with and without the use of an antibiotic envelope. Studies including both new implants and pulse generator replacements were included in the analysis. RESULTS: Five studies were included in the meta-analysis. A total of 4,490 patients underwent CIED implantation, 1,798 with an antibiotic envelope and 2,692 without an envelope. In the pooled cohort, the envelope was associated with a 69% relative risk reduction in CIED infection (0.31 [0.17, 0.58] 95% CI, P = 0.0002). Propensity matched data from three studies were analyzed to ensure accurate comparison. In the risk-matched cohort, infections were significantly lower in the envelope group (3 vs. 26, P < 0.0003). CONCLUSION: The use of antibiotic envelopes in CIED implant is associated with a significantly lower rate of infection.
Asunto(s)
Antibacterianos/administración & dosificación , Profilaxis Antibiótica , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/prevención & control , Anciano , Anciano de 80 o más Años , Antibacterianos/efectos adversos , Profilaxis Antibiótica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Factores Protectores , Medición de Riesgo , Factores de Riesgo , Resultado del TratamientoRESUMEN
BACKGROUND: Ablation for atrial fibrillation (AF) requires multiple venous sheaths and anticoagulation with heparin, both risk factors for bleeding complications. Manual compression (MC) with heparin reversal is the standard method to achieve venous hemostasis postablation; however, temporary figure-of-eight sutures (F8S) are an alternative. While this technique has been shown to be safe and effective, little is known about its effect on postprocedural recovery time. METHODS: In this retrospective cohort study, consecutive patients who underwent AF radiofrequency ablation over a 23-month period were reviewed for type of hemostasis (manual compression or figure-of-eight suture), demographics, periprocedural anticoagulation, groin complications, and procedural duration. RESULTS: A total of 104 patients were included (42 in the MC group and 62 in the F8S group). The two groups were similar for mean age, gender, weight, oral anticoagulant use, and procedural heparin dosing. Access site complications were 4.76% versus 3.23% (P = 0.68). Time from procedure end to sheath removal was lower in the F8S group (16.2 ± 8.47 vs 4.25 ± 4.14 min, P < 0.0001). Overall time from procedure end to hemostasis was 36.1 ± 10.1 min in the MC group versus 7.9 ± 5.6 in the F8S group (P < 0.0001). Times to extubation and transport out of the lab were both significantly lower in the F8S group (34.1 ± 14.6 vs 13.5 ± 5.4 min, and 44 ± 14.6 vs 21.9 ± 6.7 min, respectively, P < 0.0001). CONCLUSION: Figure-of-eight sutures provided efficient hemostasis following AF ablation, with significantly reduced postprocedure recovery time including time to hemostasis, extubation, and transport out of the lab.
RESUMEN
BACKGROUND: Patients on rivaroxaban have variable international normalized ratios (INRs) but it is uncertain if INR impacts procedural heparin requirement during left atrial ablation. We sought to examine the determinants of heparin dosing in this patient population. METHODS: We reviewed consecutive patients who received rivaroxaban within 24 hours of left atrial ablation and compared them to patients on uninterrupted warfarin. The determinants of heparin requirement were evaluated using regression analysis. We then tested a weight-based heparin dose prospectively in rivaroxaban patients. RESULTS: There were 258 patients on rivaroxaban and 213 on warfarin. The mean INR was 1.4 in the rivaroxaban group and 2.3 in the warfarin group (P < 0.01). To achieve an activated clotting time (ACT) >350 seconds, rivaroxaban patients required significantly more heparin (166.9 vs. 78.3 units/kg, P < 0.001). In the rivaroxaban group, body weight was the strongest predictor of heparin dose (r = 0.52), while INR was weakly correlated (r = -0.21). In the prospective group, 25 patients were given an initial heparin dose of 120 units/kg with 22/25 (88%) achieving an ACT > 300 seconds. There were seven and three cases of pericardial effusion in rivaroxaban and warfarin patients, respectively (P = 0.41). The average volume drained in the rivaroxaban group was elevated (988.6 vs. 275.0 mL, P = 0.21). CONCLUSIONS: Body weight is the strongest predictor of procedural heparin requirement during left atrial ablation in patients on uninterrupted rivaroxaban, even in those with an elevated INR. A heparin dose of 120 units/kg achieves an ACT > 300 seconds in the majority of patients. In cases of pericardial effusion, bleeding may be prolonged.
Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Heparina/administración & dosificación , Rivaroxabán/administración & dosificación , Tromboembolia/epidemiología , Tromboembolia/prevención & control , Administración Oral , Anticoagulantes/administración & dosificación , Peso Corporal , Relación Dosis-Respuesta a Droga , Quimioterapia Combinada/estadística & datos numéricos , Femenino , Fibrinolíticos/administración & dosificación , Fibrinolíticos/efectos adversos , Atrios Cardíacos/efectos de los fármacos , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Premedicación/estadística & datos numéricos , Prevalencia , Factores de Riesgo , Rivaroxabán/efectos adversos , Resultado del Tratamiento , Estados Unidos/epidemiologíaRESUMEN
Water is undoubtedly the vital commodity for all living creatures and required for well-being of the human society. The present work is based on the surveys and chemical analyses performed on the collected groundwater samples in a part of the Ganga basin in order to understand the sources and evolution of the water quality in the region. The two standard indices such as water quality index and synthetic pollution index for the classification of water in the region are computed. The soil and sediment analysis are carried out with the help of X-ray diffractometer (XRD) for the identification of possible source of ions in water from rock and soil weathering. The dominant minerals which include quartz, muscovite, plagioclase, and orthoclase are reported in the area. The study further utilizes the multivariate statistical techniques for handling large and complex datasets in order to get better information about the groundwater quality. The following statistical methods such as cluster analysis (CA), factor analysis (FA), and principal component analysis (PCA) are applied to handle the large datasets and to understand the latent structure of the data. Through FA/PCAs, we have identified a total of 3 factors in pre-monsoon and 4 factors in post-monsoon season, which are responsible for the whole data structure. These factors explain 77.62 and 82.39% of the total variance of the pre- and post-monsoon datasets. On the other hand, CA depicted the regions that have similar pollutants origin. The average value of synthetic pollution index of groundwater during pre-monsoon is 9.27, while during post-monsoon, it has been recorded as 8.74. On the other hand, the average values of water quality index of groundwater during pre-monsoon and post-monsoon seasons are found as 217.59 and 233.02, respectively. The study indicates that there occurs an extensive urbanization with gradual vast development of various small- and large-scale industries, which is responsible for degradation in water quality. The overall analysis reveals that the agricultural runoff, waste disposal, leaching, and irrigation with wastewater are the main causes of groundwater pollution followed by some degree of pollution from geogenic sources such as rock and soil weathering, confirmed through XRD analysis.
Asunto(s)
Monitoreo del Ambiente , Agua Subterránea/química , Contaminantes Químicos del Agua/análisis , Calidad del Agua , Agricultura , Análisis Factorial , Sedimentos Geológicos/química , Agua Subterránea/análisis , India , Industrias , Modelos Químicos , Análisis de Componente Principal , Estaciones del Año , Urbanización , Aguas Residuales/química , Difracción de Rayos XRESUMEN
BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.
RESUMEN
Ultrasound imaging has been used in a range of cardiac interventions. We describe the use of intravascular ultrasound to assist in coronary sinus lead implantation in a patient where contrast venography was contraindicated.
Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Seno Coronario/diagnóstico por imagen , Ultrasonografía Intervencional , Anafilaxia/inducido químicamente , Medios de Contraste/efectos adversos , Humanos , Masculino , Implantación de Prótesis/métodosRESUMEN
We theoretically study the stationary-state vortex lattice configurations of rotating spin-orbit (SO)- and coherently-coupled spin-1 Bose-Einstein condensates (BECs) trapped in quasi-two-dimensional harmonic potentials. The combined effects of rotation, SO and coherent couplings are analyzed systematically from the single-particle perspective. Through the single-particle Hamiltonian, which is exactly solvable for one-dimensional coupling, we illustrate that a boson in these rotating SO- and coherently-coupled condensates are subjected to effective toroidal, symmetric double-well, or asymmetric double-well potentials under specific coupling and rotation strengths. In the presence of mean-field interactions, using the coupled Gross-Pitaevskii formalism at moderate to high rotation frequencies, the analytically obtained effective potential minima and the numerically obtained coarse-grained density maxima position are in excellent agreement. On rapid rotation, we further find that the spin-expectation per particle of an antiferromagnetic spin-1 BEC approaches unity indicating a similarity in the response with ferromagnetic SO-coupled condensates.
RESUMEN
BACKGROUND: Arterial invasive monitoring is the most common method in the USA for hemodynamic monitoring during atrial fibrillation (AF) ablation. Although studies have shown favorable comparison between non-invasive and invasive hemodynamic monitoring (IHM) in non-cardiac procedures under general anesthesia, limited data is available for complex cardiac procedures such as AF ablation in the USA. With progressive improvement in AF ablation procedural safety, particularly with routine use of intracardiac echocardiography (ICE) to monitor for pericardial effusion, it is unclear if invasive hemodynamic monitoring provides any advantage over non-invasive methods. Therefore, the purpose of this study is to determine whether noninvasive hemodynamic monitoring is non-inferior to invasive hemodynamic monitoring during AF ablation under general anesthesia in patients without major cardiac structural abnormality. METHODS: A multi-center retrospective data of AF ablation from July 2019 to December 2020 was extracted. A total of three hundred and sixty-two patients (362) were included, which were divided into group A (non-invasive hemodynamic monitoring) and group B (invasive hemodynamic monitoring). The primary outcome was to compare procedural safety between the two groups. RESULTS: Out of 362 patients, 184 (51%) received non-invasive and 178 (49%) received invasive hemodynamic monitoring with similar baseline characteristics. There was no significant difference between the two groups in complication rates (groin hematoma, pericardial effusion, cardiac tamponade). Mean procedure time was longer in group B with 3.35% arterial site discomfort. Urgent arterial access was required in only 1 patient in group A. CONCLUSION: This retrospective multicenter study strongly suggests that catheter ablation for atrial fibrillation under general anesthesia can be safely performed with noninvasive hemodynamic monitoring without requiring arterial access, with potential benefit in procedural duration and cost.