Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
Más filtros

Intervalo de año de publicación
1.
Clin Oral Investig ; 28(3): 205, 2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38459266

RESUMEN

OBJECTIVE: To assess the anesthetic efficacy of articaine with the needle-free/Comfort-in™ method compared to the conventional needle method. To assess pain during anesthesia application, onset of anesthesia and patient`s self-reported quality of life-related to oral health after the dental emergency appointment. MATERIALS AND METHODS: This parallel, randomized clinical trial was conducted by a single operator/dentist in the state of Maranhao, northeast of Brazil. Included participants were adult dental patients with one molar (maxillary) or premolar (maxillary or mandibular) tooth diagnosed with symptomatic irreversible pulpitis. The primary outcome was the anesthetic efficacy, measured using a combination of electrical and cold pulp tests (cold + EPT) and the Numerical Rating Scale (NRS). Secondary outcomes were pain during anesthesia application, onset of anesthesia, and patient`s quality-of-life (measured with the OHIP-14). RESULTS: 62 patients were randomized in the anesthesia needle-free group and Comfort-in group (34.26 ± 10.786 × 33.29 ± 8.399 years old, respectively). The group of patients in the Comfort-in group had 71.0% success. Patients from the Comfort-in group reported statistically lower pain during the anesthesia application than patients from the conventional group (2.13 ± 2.172 × 6.03 ± 3.146 NRS scores, respectively) as well as immediately after the anesthetic procedure. Patients self-reported negative impact in quality of life was similar between groups before (p > 0.05) and after (p > 0.05) the dental emergency. CONCLUSIONS: Comfort-in™ had similar efficacy to the conventional needle method. CLINICAL RELEVANCE: This trial showed that it is possible to anesthetize patients with tooth pulpits without using needles to provide comfort mainly to anxious patients.


Asunto(s)
Anestesia Dental , Bloqueo Nervioso , Pulpitis , Adulto , Humanos , Adulto Joven , Carticaína , Pulpitis/cirugía , Anestésicos Locales , Calidad de Vida , Bloqueo Nervioso/métodos , Anestesia Dental/métodos , Dolor , Método Doble Ciego , Nervio Mandibular , Lidocaína
2.
Clin Oral Investig ; 27(3): 1153-1158, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36104605

RESUMEN

AIM: To evaluate the influence of different kinematics on the efficiency and safety of an engine-driven file for glide path preparation in second mesiobuccal canals (MB2) of maxillary molars. In addition, the torsional resistance of the file was assessed after use. METHODOLOGY: Thirty-six maxillary first and second molars with two canals in the mesiobuccal root were selected and the anatomy of the canals was verified by micro-CT. The teeth were divided into 4 groups (n = 9) according to the kinematics used for glide path preparation: continuous rotation (CR), 30°/150° reciprocation (REC 30°/150°), 30°/90° reciprocation (REC 30°/90°), and 90° optimum glide path motion (OGP 90°). The duration of the procedure, number of canals in which the file reached the full working length (RFWL), canal volume before and after the procedure, rate of file fracture, and file torsional strength after use were evaluated. The ANOVA and Tukey tests or Kruskal-Wallis and Dunn tests were used for statistical analysis. RESULTS: No significant differences among the groups were found for procedure duration, success at reaching the FWL, distance from the file to apex, and number of fractured files (P > 0.05). The CR group showed a significant decrease in rotation angle compared with REC 90° and OGP 90° groups (P < 0.05). There was no significant difference in canal volume among the groups (P > 0.05). CONCLUSION: The type of kinematics used did not affect the efficiency, success rate, and shaping ability of the file during glide path preparation. CR seems to induce more torsional stress than the other kinematics. CLINICAL RELEVANCE: The glide path preparation of narrow canals such as the MB2 is difficult and accidents such as file fracture may occur. This study showed that reciprocation with different file angulations can be safer during this challenging stage.


Asunto(s)
Preparación del Conducto Radicular , Raíz del Diente , Fenómenos Biomecánicos , Preparación del Conducto Radicular/métodos , Diente Molar , Cavidad Pulpar , Diseño de Equipo
3.
Dent Traumatol ; 32(5): 385-9, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27140332

RESUMEN

BACKGROUND AND AIM: Subjective pulp tests are not trustworthy, particularly in traumatized teeth, and may lead to inaccurate diagnosis. The use of an objective test such as pulse oximetry (PO) could be a more reliable method to properly evaluate pulp status in this condition. The aim of this study was to analyze the effectiveness of PO in determining pulp vitality in traumatized teeth based on oxygen saturation measurements (%SpO2 ). SUBJECTS AND METHODS: Fifty-nine permanent teeth that had undergone lateral luxation, and which were unresponsive to a cold spray test and were free from signs of necrosis, were selected and tested with PO at 7, 30 and 60 days after trauma. RESULTS: Fifty-nine teeth were tested. At 7 days after trauma, 8 teeth had low rates of oxygenation, compared to 10 at 30 and 60 days. Low rates were defined as a saturation reading ≤77%SpO2 . These teeth were assigned to the pulp necrosis (PN) group. The other 49 teeth were either considered to have healthy pulps (HP) (saturation ≥90%SpO2 ) or were assigned to a pulpitis (PP) group (saturation ≥78 to ≤89%SpO2 ). The 10 non-responsive teeth were followed up for 1 year and all exhibited indications for endodontic treatment. The other 49 teeth (HP or PP) began to show positive responses to the cold spray (after 3-9 months of follow up). No significant differences (P < 0.05) were detected between the three periods analyzed, but %SpO2 rates were significantly different (P < 0.01) between the groups (HP vs PP, HP vs PN and PP vs PN). CONCLUSIONS: PO can be extremely useful for the assessment of dental pulp status in traumatized teeth, particularly when these teeth do not show signs of PN and do not respond to cold tests.


Asunto(s)
Necrosis de la Pulpa Dental/diagnóstico , Prueba de la Pulpa Dental , Oximetría , Pulpa Dental , Dentición Permanente , Humanos
4.
ScientificWorldJournal ; 2015: 686259, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26347249

RESUMEN

OBJECTIVES: To evaluate the influence of dentine on the pH of different medications in standardized simulated canals. MATERIALS AND METHODS: Forty resin blocks were divided into groups with and without dentine powder, as follows: 2% chlorhexidine gel; 2% chlorhexidine gel associated with calcium hydroxide PA; calcium hydroxide PA delivered in propylene glycol 600; and NPG delivered in distilled water. The dentine powder was obtained from the root dentine of bovine teeth and added to the medications. The simulated canals were placed in containers with 1.5 mL of deionized water and pH was monitored in multiple intervals, up to 30 days. The mean pH values were calculated and submitted to statistical analysis using paired Student's t-test and ANOVA complemented by the Tukey test (p < 0.05). RESULTS: There was no statistical difference between the groups with and without dentine powder (p > 0.05). The pH values of calcium hydroxide were significantly higher than those of NPG in the first 24 hours (p < 0.05). After 7 days, both behaved in a similar manner. CONCLUSION: The addition of dentine powder to the medications evaluated did not alter the pH of the external solution in any of the time points tested.


Asunto(s)
Hidróxido de Calcio/química , Clorhexidina/química , Dentina/química , Vidrio/química , Propilenglicol/química , Irrigantes del Conducto Radicular/química , Animales , Bovinos , Cavidad Pulpar/cirugía , Geles , Concentración de Iones de Hidrógeno , Incisivo/cirugía , Modelos Anatómicos , Niobio/química , Preparación del Conducto Radicular/métodos
5.
Braz Oral Res ; 38: e006, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38198306

RESUMEN

The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.


Asunto(s)
Cavidad Pulpar , Oro , Microtomografía por Rayos X , Cavidad Pulpar/diagnóstico por imagen , Análisis de Varianza , Diente Molar/diagnóstico por imagen
6.
J Endod ; 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38945199

RESUMEN

INTRODUCTION: This study investigates the feasibility of a dynamic navigation system (DNS) small field of view workflow (DNS-SFOVw) for fiber-post removal and compares its accuracy and efficiency to the conventional large field of view workflow (DNS-LFOVw). METHODS: Fifty-six extracted human maxillary molars were divided into DNS-SFOVw (n=28) and DNS-LFOVw (n=28). The palatal canal was restored with an intra-radicular RelyX fiber post and luted with RelyX Unicem; a core buildup was used. Teeth were mounted in a 3D-printed surgical jaw. A preoperative cone-beam-computed tomography (CBCT) scan was taken with a 40 x 40 mm FOV for the DNS-SFOVw and a single arch CBCT scan for the DNS-LFOVw. The drilling entry point, trajectory, angle, and depth were planned in the X-guide software. The DNS registration method for the DNS-SFOVw was virtual-based registration on teeth, and the marker point-based method was used for the DNS-LFOVw. The fiber posts were drilled out under DNS guidance. A postoperative CBCT scan was taken. Three-dimensional (3D) deviations, angular deflection, number of mishaps, registration, and total operation time were calculated. RESULTS: The DNS-SFOVw was as accurate as DNS-LFOVw (p>.05). The DNS-LFOVw registration time was less than DNS-SFOVw (p<.05). There was no difference in the number of mishaps (p>.05). Both DNS-SFOVw and DNS-LFOVw were time-efficient, with DNS-LFOVw taking less total operational time (p<.05). CONCLUSION: Within the limitations of this in-vitro study, the DNS-SFOVw was as accurate as the DNS-LFOVw for fiber-post removal. Both DNS-LFOVw and DNS-SFOVw were time-efficient in removing fiber-posts.

7.
Braz Dent J ; 35: e245883, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38775594

RESUMEN

This study assessed the intratubular antibacterial ability of different activated irrigations after chemical mechanical preparation. Seventy-two palatal root canals of upper molars were infected with Enterococcus faecalis for 4 weeks, and then initial bacterial collection from the main root canal was performed. The root canals were prepared by using a WaveOne Gold large (45/.05) and distributed into 6 groups according to the activation of the final irrigation: ultrasonic activation (UA), XP-Endo Finisher (25/.00), XP Clean (25/.02), EasyClean (25/.04) in reciprocating motion and continuous rotary motion (ECRot), and conventional irrigation. After final irrigation, another bacterial collection from the main root canal was performed, and the root was sectioned transversely in three-thirds and stained for analysis by confocal laser microscopy. Intratubular bacteria were collected through dentin powder and plated for bacterial viability analysis. Intergroup and intragroup comparisons were performed by using analysis of variance and repeated measures analysis of variance, respectively, both at 5% significance. ECRot had higher antibacterial ability than UA (p<0.05), and both were superior to the other groups (p<0.05) in both methodologies. It can be concluded that activation of final irrigation enhances the disinfection of the root canal system, and activators have different efficacies.


Asunto(s)
Antibacterianos , Enterococcus faecalis , Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Humanos , Irrigantes del Conducto Radicular/farmacología , Preparación del Conducto Radicular/métodos , Antibacterianos/farmacología , Cavidad Pulpar/microbiología , Microscopía Confocal , Irrigación Terapéutica/métodos , Diente Molar
8.
Braz Dent J ; 35: e245611, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537014

RESUMEN

This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Humanos , Preparación del Conducto Radicular/métodos , Ultrasonido , Irrigantes del Conducto Radicular , Irrigación Terapéutica/métodos , Microtomografía por Rayos X , Dentina
9.
Lasers Med Sci ; 28(1): 253-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22710741

RESUMEN

Different treatments of dentin walls, as laser irradiation, prior to obturation can influence the adhesion ability of endodontic sealers. Therefore, the objective of this study was to compare in vitro the shear bond strength of four resin-based sealers to dentin treated with citric acid solution or erbium: yttrium, aluminum, garnet (Er:YAG) irradiation. A total of 240 slices with 1.6 mm of thickness were cut using middle third of 84 teeth. Each slice was widened using a #45 taper.06 rotary K3 instrument. The sample was divided into groups according to dentin pretreatment (15 % citric acid or Er:YAG laser) and sealer used (AH Plus, Acroseal, EndoREZ, or RealSeal). Shear bond strength was measured using a universal materials testing machine. As results, significant differences were found when comparing sealers between all groups (p < 0.05) by Kruskal-Wallis test, regardless of the pretreatment used. Comparing pretreatments, 15 % citric acid solution had better outcomes than Er:YAG laser, with significant differences in all groups, except for Acroseal groups (p < 0.05). It was concluded that RealSeal and 15 % citric acid solution achieved the best results regarding the sealer and pretreatment used, respectively.


Asunto(s)
Resinas Epoxi/química , Láseres de Estado Sólido , Materiales de Obturación del Conducto Radicular/química , Ácido Cítrico , Resinas Epoxi/efectos de la radiación , Humanos , Técnicas In Vitro , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Materiales de Obturación del Conducto Radicular/efectos de la radiación , Estadísticas no Paramétricas , Propiedades de Superficie
10.
Braz Dent J ; 34(1): 1-11, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36888836

RESUMEN

A continuous search for bioactive materials capable of supporting the replacement of damaged pulp tissue, with effective sealing potential and biocompatibility, has represented the attention of studies over the last decades. This study involves a narrative review of the literature developed by searching representative research in PUBMED/MEDLINE and searches in textbooks associated with the mechanism of action of bioactive materials (calcium hydroxide, mineral trioxide aggregate (MTA), and calcium silicate cements). The reflective analysis of the particularities of the chemical elements of these materials, considering the tissue and antibacterial mechanism of action, allows a better understanding of the characteristics and similarities in their tissue responses. Calcium hydroxide paste remains the antibacterial substance of choice as intracanal dressing for the treatment of root canal system infections. Calcium silicate cements, including MTA, show a favorable biological response with the stimulation of mineralized tissue deposition in sealed areas when in contact with connective tissue. This is due to the similarity between the chemical elements, especially ionic dissociation, the potential stimulation of enzymes in tissues, and the contribution towards an alkaline environment due to the pH of these materials. The behavior of bioactive materials, especially MTA and the new calcium silicate cements in the biological sealing activity, has been shown to be effective. Contemporary endodontics has access to bioactive materials with similar properties, which can stimulate a biological seal in lateral and furcation root perforations, root-end fillings and root fillings, pulp capping, pulpotomy, apexification, and regenerative endodontic procedures, in addition to other clinical conditions.


Asunto(s)
Hidróxido de Calcio , Materiales de Obturación del Conducto Radicular , Hidróxido de Calcio/farmacología , Materiales de Obturación del Conducto Radicular/farmacología , Materiales de Obturación del Conducto Radicular/química , Cementos Dentales/química , Compuestos de Calcio/farmacología , Compuestos de Calcio/química , Silicatos/farmacología , Silicatos/química , Antibacterianos/uso terapéutico , Óxidos/farmacología , Óxidos/química , Combinación de Medicamentos , Compuestos de Aluminio/farmacología , Compuestos de Aluminio/química
11.
Braz Dent J ; 34(2): 35-40, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37194855

RESUMEN

This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Tratamiento del Conducto Radicular , Microtomografía por Rayos X , Oro
12.
Polymers (Basel) ; 15(7)2023 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-37050293

RESUMEN

This study evaluated the apical sealing ability and bioactivity of an experimental gutta-percha containing niobium phosphate bioglass. Thirty-six human premolars were endodontically prepared and divided into three groups: GPC-filling with conventional gutta-percha; GBC-filling with bioceramic gutta-percha (EndoSequence BC); GNB-filling with experimental gutta-percha containing niobophosphate. Teeth were stored in tubes containing 2 mL of simulated body fluid (SBF) solution in an oven for 30 days. Then, the samples were immersed in lanthanum nitrate solution and analyzed for apical nanoleakage (NI) with a scanning electron microscope (SEM/EDS) and transmission electron microscope (TEM). Gutta-percha specimens were immersed for 28 days (SBF) and analyzed in SEM/EDS and X-ray diffraction (XRD) to assess bioactivity. NI data originated from the SEM/EDS were analyzed using the Kruskal-Wallis test (α = 5%). NI data originated from TEM and bioactivity were descriptively reported. Statistical analysis did not detect a significant difference between groups (p = 0.13) for NI. In the bioactivity analysis, an abundant layer of hydroxyapatite was identified only in the surface of the GNB group samples. The gutta-percha containing niobophosphate bioglass promoted an apical sealing similar to EndoSequence BC, in addition to demonstrating bioactivity through the deposition of hydroxyapatite on the surface of the material after immersion in SBF.

13.
Aust Endod J ; 49 Suppl 1: 315-322, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36658667

RESUMEN

This study evaluated, through micro-computed tomography (micro-CT), the volume of irrigant diffusion by different techniques of final agitation. Sixty mesiobuccal canals were scanned in a micro-CT and standardised according to the volume. They were instrumented with the MTwo 40/04 system and using the Terebrix 35 contrast solution as irrigant, were divided into six groups (n = 10): Conventional irrigation with syringe and needle (CI), EndoActivator (EA), EasyClean (EC), RinsEndo (RE), Utrasonic agitation (UI) and XP-Clean (XP). A second micro-CT scan was performed and the total irrigant volume and in the final 3 mm apical were determined. The data were analysed using the Anova, Kruskal-Wallis and Dunn tests (p < 0.05). UI and XP showed a higher percentage of total diffusion than CI, EA and RS groups (p < 0.05). In apical diffusion, there was no significant difference between groups (p > 0.05). The final agitation system increases the diffusion of irrigating agents inside the root canal.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Microtomografía por Rayos X , Preparación del Conducto Radicular/métodos , Irrigantes del Conducto Radicular/uso terapéutico , Tratamiento del Conducto Radicular , Irrigación Terapéutica/métodos , Hipoclorito de Sodio
14.
J Clin Exp Dent ; 15(11): e938-e944, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38074173

RESUMEN

Background: This study aimed to assess the knowledge of Brazilian endodontists regarding the use of cone beam computed tomography (CBCT) in endodontic therapy. Material and Methods: An invitation to participate in the research was sent to 3256 professionals through class groups on social networks and via email. Participants answered an online questionnaire consisting of 11 questions about the clinical situations in which they used CBCT and whether they had any knowledge of the technical protocols such as parameters of field of view (FOV) and voxels of the CBCT equipment. The questionnaire was answered by 742 endodontists who represented 22.7% of the invited professionals. Results: The data obtained indicate that 76.7% of the participants use or have used CBCT during endodontic treatments. The most often reported clinical conditions for using the CBCT were: root fractures (64%), locating the canals (58.7%), perforations (53.9%), and root resorption (42.1%). More than 60% of the participants stated that they do not have information about the voxel, FOV, and the CBCT system used in their requests. Only 34.1% reported using CBCT to the performed endodontic treatments follow-up. Conclusions: CBCT was a tool widely utilized by the participants, with root fracture being the clinical condition with the highest indication for CBCT. Many professionals were unaware of the technical protocol used in the exams. Key words:Endodontics, Cone Beam Computed Tomography, Endodontic Therapy.

15.
J Conserv Dent ; 25(6): 596-599, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36591588

RESUMEN

Context: Manufacturers have produced a wide variety of nickel-titanium (NiTi) alloys, but the available literature is limited on the accuracy of some integrated electronic apex locators (EAL) used with different NiTi heat treatments in working length (WL) determination. Aim: This study aims to evaluate ex vivo , the influence of different heat treatments of NiTi instruments, and the diameter of the apical preparation on the accuracy of an EAL used during root canal preparation using an integrated EAL and motor unit. Materials and Methods: Nineteen extracted human mandibular incisors were included in the study. The WL control was determined by the visual method. Instruments of Mtwo, Reciproc, Reciproc Blue, WaveOne Gold, Twisted File Adaptive, and Hyflex CM systems, with diameters from 0.25 mm to 0.50 mm, were used to measure WL during root canal preparation. The electrical resistivity of instruments with a diameter of 0.25 mm from each system was evaluated using an Inductance, Capacitance, and Resistance (LCR) meter. Statistical Analysis Used: Data were statistically analyzed using Fisher's exact test and Kruskal-Wallis test. Results: The different heat treatments and different diameters did not influence the precision of the EAL (P > 0.05). Conclusion: The heat treatment and the diameter of the apical preparation did not influence the accuracy of WL determination by an EAL integrated with the endodontic motor.

16.
J Dent Educ ; 86(6): 751-758, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35061917

RESUMEN

OBJECTIVES: The aim of this cross-sectional retrospective study was to evaluate radiographically the technical quality of root canal treatment performed by undergraduate students using reciprocating NiTi instrumentation and single-cone obturation. METHODS: Endodontic treatment on 1102 teeth performed by undergraduate students from the School of Dentistry of the University of Santa Cecilia (Brazil) was evaluated. All root canal preparations were performed using Reciproc files and were irrigated with 1% NaOCl. The root canal was filled with gutta-percha, along with AH Plus sealer, using the single-cone obturation technique. The technical quality of the root canal treatment was evaluated based on immediate postoperative radiographs. Distance between the end of the filling and the radiographic apex, the filling density, and the taper of the root filling was assessed. Inter-examiner agreement statistic (Kappa) and Chi-square statistic test were used for statistical evaluation of the results. Differences were considered statistically significant when p < 0.05. RESULTS: Anterior teeth, maxillary premolars, and molars presented better results than mandibular premolars and molars (p < 0.05). Mandibular premolars presented a high incidence of a short length of obturation (33.34%) and mandibular molars presented a high incidence of overfilling (6.55%). The majority of the treatment analyzed (62.46%) fulfilled all the criteria showing acceptable working length, taper, and density of obturation. Instrument fractures occurred in eighteen root canals (0.81%). CONCLUSIONS: The use of NiTi reciprocating instruments with the single-cone obturation technique provided an acceptable quality of endodontic treatment in the majority of the cases performed by undergraduate students.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Estudios Transversales , Cavidad Pulpar , Humanos , Estudios Retrospectivos , Materiales de Obturación del Conducto Radicular/uso terapéutico , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular , Estudiantes
17.
J Endod ; 48(5): 572-596, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35114271

RESUMEN

INTRODUCTION: Culture-independent molecular studies have shown a broad spectrum of bacterial taxa that persist after chemomechanical procedures (CMP). Therefore, this study systematically reviewed these reports to explore the prevalence of bacteria in post-instrumentation samples of root canals from permanent teeth, especially of as-yet-uncultivated/difficult-to-culture bacteria. METHODS: Electronic databases were searched from 2007 to January 2021. Clinical studies using culture-independent molecular methods to identify species-level taxa before and after CMP were included. Studies were critically appraised using the Joanna Briggs Institute Prevalence Critical Appraisal Checklist and the funnel plot analysis. The meta-analysis was performed on the prevalence of as-yet-uncultivated/difficult-to-culture bacterial taxa using RStudio. RESULTS: A total of 3781 titles were screened, but only 20 studies were included. The most frequent species in post-instrumentation samples were Streptococcus spp., Leptotrichia buccalis, Fusobacterium nucleatum, and Capnocytophaga ochracea. The detection frequency of some species increased after CMP, including mainly Firmicutes members such as streptococci, Enterococcus faecium, Selenomonas noxia, and Solobacterium moorei. The prevalence (confidence interval) of difficult-to-culture species was as follows: Dialister invisus, 17% (7%-29%); Solobacterium moorei, 14% (8%-23%); Bacteroidaceae [G-1] bacterium HMT 272, 13% (5%-23%); and Filifactor alocis, 11% (3%-23%). CONCLUSIONS: The prevalence of as-yet-uncultivated/difficult-to-culture bacterial taxa in post-instrumentation samples was low. The persistent species belonged mainly to the phylum Firmicutes, and streptococci were the major members. Future larger clinical studies on the composition of the whole bacterial community that persist after CMP are still necessary for a better understanding of bacterial interactions and their clinical significance in the treatment outcome.


Asunto(s)
Cavidad Pulpar , Periodontitis Periapical , Humanos , Bacterias , Cavidad Pulpar/microbiología , ADN Bacteriano/análisis , Firmicutes , Periodontitis Periapical/terapia , Prevalencia , Preparación del Conducto Radicular/métodos
18.
J Mech Behav Biomed Mater ; 125: 104971, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34798534

RESUMEN

OBJECTIVE: This study evaluated the influence of adding bioactive glasses particles [Niobophosphate (NbG) or bioglass (45S5)] into endodontic cements in relation to physical, chemical and biological properties. METHODS: The following commercial cements were used as comparison: AH Plus (Dentsply), Endofill (Dentsply), MTA Fillapex (Angelus) and EndoSequence (BC Sealer, Brasseler). Setting time, radiopacity, flow rate, weight loss/variation, alkaline capacity (pH) at different time-intervals (24h/48h/7d/14d/28d), bioactivity (assessed under SEM/EDS, FTIR/ATR and XDR) and cell viability were measured. Data were analyzed by One-way ANOVA/Holm-Sidak post-test (α = 5%) (normal distribution) and Kruskal-Wallis/Students-Newman-Keuls post-test (α = 5%) (non-normal distribution). RESULTS: Bioactive endodontic experimental cements (containing NbG or 45S5) had high alkalinization capacity. The experimental cements presented high weight loss/variation (p < 0.001). 45S5 experimental cement did not present radiopacity (p < 0.001). AH Plus had the lowest cell cytotoxicity when compared to the other tested cements (p < 0.001). Regarding bioactivity, SEM/EDS analyses showed precipitates with high concentrations of Ca/P for 45S5 and NbG, as well as for MTA Fillapex and BC Sealer. AH plus and Endofill did not present bioactive precipitates. FTIR/ATR and XDR analyses found hydroxyapatite precursors for NbG, 45S5, MTA Fillapex and BC Sealer. SIGNIFICANCE: The incorporation of bioactive particles (NbG or 45S5) into endodontic cements had potential to neutralize acidic environments and induced formation of hydroxyapatite precursors. Clinically, these would produce a cement that is bactericidal and have the potential to improve tissue healing. The improved radiopacity and flowability would facilitate the visualization of the material in the radiograph and the filling of anatomical complexities during root canal obturation. As drawbacks, the excessive weight loss and post-setting cytotoxicity could result in clinical degradation of the cement and adjacent tissue irritation for the patient.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Cementos para Huesos , Durapatita , Cementos de Ionómero Vítreo , Humanos
19.
Comput Biol Med ; 136: 104679, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34325229

RESUMEN

BACKGROUND: The appearance of high-density root obturating materials, such as gutta-percha and intracanal posts, on cone-beam computed tomography (CBCT) scans is substantially different from that seen in the specimen. This study evaluated the effectiveness of different CBCT software in the reduction of blooming artifacts when examining teeth with intracanal posts. METHOD: The sample included 42 human single-rooted teeth with two types of posts: G1 - low-fusion alloy posts; G2 - gold alloy posts. CBCT scans were obtained using two scanners, PreXion 3D Elite® and Carestream 9000C 3D®. First, the posts were measured using a digital micrometer (standard reference, control). Post diameters were determined using the Blooming Artifact Reduction (BAR) tool of the e-Vol DX software and of the PreXion3D Image Analysis System. Statistical data were evaluated using the van Der Waerden nonparametric analysis of variance and, after that, normalized data were analyzed using the Tukey test. The level of significance was set at α = 5 %. RESULTS: There were no significant differences (p > 0.05) between the diameters of intracanal posts on the CT scans when the e-Vol DX was used, or when these results were compared with those obtained using a micrometer. There were significant differences in post diameters determined using the PreXion3D Image Analysis System when compared with the e-Vol DX and the micrometer values (p < 0.05). CONCLUSIONS: The use of the e-Vol DX BAR filter eliminated blooming artifacts. There were no dimensional changes in the CBCT images of the low-fusion and gold alloy intracanal posts using the e-Vol DX BAR filter.


Asunto(s)
Diente no Vital , Artefactos , Tomografía Computarizada de Haz Cónico , Humanos , Programas Informáticos
20.
Aust Endod J ; 47(3): 544-549, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33913601

RESUMEN

This study evaluated the resistance to flexural fatigue and torsional strength of files for glide path preparation in continuous rotation or Optimum Glide Path motion (OGP). ScoutRace 15.02 and ProGlider 16.02 files were used in a dynamic testing device during preparation of simulating curved root canals (40-degree curvature and 5 mm radius). For the torsional test, a machine was used to test torsion measured maximum torsional strength (N.cm). Two-way anova and Tukey's multiple comparisons test were used for statistical analysis. Files in OGP motion had a statistically better resistance to flexural fatigue (P < 0.05). ProGlider files took longer time to failure than ScoutRace files only when OGP was used (P < 0.05). The torsional test revealed that OGP produced significantly less torsional stress than rotary motions for both types of glide path files (P < 0.05) In conclusion, OGP motion increased substantially the mechanical safety of endodontic glide path files.


Asunto(s)
Deportes , Proyectos de Investigación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA