Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Thorac Cardiovasc Surg ; 71(5): 387-397, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-35644134

RESUMEN

BACKGROUND: The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate clinical outcomes and hemodynamic performance achieved with minimally invasive aortic valve replacement (MI-AVR) as compared with conventional AVR. METHODS: Patients who underwent surgical AVR with the Avalus bioprosthesis, as part of a prospective multicenter non-randomized trial, were included in this analysis. Surgical approach was left to the discretion of the surgeons. Patient characteristics and clinical outcomes were compared between MI-AVR and conventional AVR groups in the entire cohort (n = 1077) and in an isolated AVR subcohort (n = 528). Propensity score adjustment was performed to estimate the effect of MI-AVR on adverse events. RESULTS: Patients treated with MI-AVR were younger, had lower STS scores, and underwent concomitant procedures less often. Valve size implanted was comparable between the groups. MI-AVR was associated with longer procedural times in the isolated AVR subcohort. Postprocedural hemodynamic performance was comparable. There were no significant differences between MI-AVR and conventional AVR in early and 3-year all-cause mortality, thromboembolism, reintervention, or a composite of those endpoints within either the entire cohort or the isolated AVR subcohort. After propensity score adjustment, there remained no association between MI-AVR and the composite endpoint (hazard ratio: 0.86, 95% confidence interval: 0.47-1.55, p = 0.61). CONCLUSION: Three-year outcomes after MI-AVR with the Avalus bioprosthetic valve were comparable to conventional AVR. These results provide important insights into the overall ability to reduce the invasiveness of AVR without compromising outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Estudios Retrospectivos
2.
Circ J ; 85(7): 1035-1041, 2021 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-33776017

RESUMEN

BACKGROUND: The PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Japan Trial was developed to assess the safety and effectiveness of the 17-mm Avalus bioprosthesis (Medtronic, Minneapolis, MN, USA) in patients undergoing surgical aortic valve replacement.Methods and Results:The primary endpoint in the trial was the percentage of patients achieving the composite of at least 1 class improvement in New York Heart Association (NYHA) functional class at 1 year compared with baseline and effective orifice area index (EOAI) of 0.6 cm2/m2or greater at 1-year after implantation, compared with a performance goal of 60%. The present study reports outcomes through 2 years. Eleven patients were implanted (10 [91%] female, median age 78.3 years). From baseline to 1 year, 10 subjects (91%) showed an improvement in NYHA classification. At 1 year, mean (±SD) EOAI was 0.82±0.17 cm2/m2, with 10 patients (91%) having an EOAI ≥0.6 cm2/m2. As such, 9 of 11 patients (82%) successfully met the primary endpoint. One death occurred between the 1- and 2-year follow-up visits, unrelated to the valve. There were no valve reinterventions, explants, or device deficiencies through 2 years. CONCLUSIONS: The PERIGON Japan Trial met its primary endpoint. Surgical implantation of the 17-mm Avalus aortic bioprosthesis can be performed with an acceptable incidence of device-related adverse events, and the valve performs effectively based on echocardiographic findings.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Japón , Masculino , Resultado del Tratamiento
3.
JACC Cardiovasc Interv ; 16(23): 2868-2879, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-37902145

RESUMEN

BACKGROUND: High surgical risk may preclude mitral valve replacement in many patients. Transcatheter mitral valve replacement (TMVR) using transfemoral transseptal access is a novel technology for the treatment of mitral regurgitation (MR) in high-risk surgical patients. OBJECTIVES: This analysis evaluates 30-day and 1-year outcomes of the Intrepid TMVR Early Feasibility Study in patients with ≥moderate-severe MR. METHODS: The Intrepid TMVR Early Feasibility Study is a multicenter, prospective, single-arm study. Clinical events were adjudicated by a clinical events committee; endpoints were defined according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 33 patients, enrolled at 9 U.S. sites between February 2020 and August 2022, were included. The median age was 80 years, 63.6% of patients were men, and mean Society of Thoracic Surgeons Predicted Risk of Mortality for mitral valve replacement was 5.3%. Thirty-one (93.9%) patients were successfully implanted. Median postprocedural hospitalization length of stay was 5 days, and 87.9% of patients were discharged to home. At 30 days, there were no deaths or strokes, 8 (24.2%) patients had major vascular complications and none required surgical intervention, there were 4 cases of venous thromboembolism all successfully treated without sequelae, and 1 patient had mitral valve reintervention for severe left ventricular outflow tract obstruction. At 1 year, the Kaplan-Meier all-cause mortality rate was 6.7%, echocardiography showed ≤mild valvular MR, there was no/trace paravalvular leak in all patients, median mitral valve mean gradient was 4.6 mm Hg (Q1-Q3: 3.9-5.3 mm Hg), and 91.7% of survivors were in NYHA functional class I/II with a median 11.4-point improvement in Kansas City Cardiomyopathy Questionnaire overall summary scores. CONCLUSIONS: The early benefits of the Intrepid transfemoral transseptal TMVR system were maintained up to 1 year with low mortality, low reintervention, and near complete elimination of MR, demonstrating a favorable safety profile and durable valve function.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios de Factibilidad , Estudios Prospectivos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología
4.
J Thorac Cardiovasc Surg ; 164(3): 822-829.e6, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-33339597

RESUMEN

OBJECTIVES: Although the impact of prosthesis-patient mismatch (PPM) on survival has been widely studied, there has been little debate about whether the current definition of PPM truly reflects hemodynamic obstruction. This study aimed to validate the categorization of indexed effective orifice area (EOAi) for the classification of PPM. METHODS: In total, 2171 patients who underwent aortic valve replacement with a surgical stented bioprosthesis in 5 trials (CoreValve US High-Risk, SURTAVI [Surgical Replacement and Transcatheter Aortic Valve Implantation Trial], Evolut Low Risk, PERIGON [PERIcardial SurGical AOrtic Valve ReplacemeNt] Pivotal Trial for the Avalus valve, and PERIGON Japan) were used for this analysis. The echocardiographic images at the 1-year follow-up visit were evaluated to explore the association between EOAi and mean aortic gradient and its interaction with other patient characteristics, including obesity. In addition, different criteria of PPM were compared with reflect elevated mean aortic gradients (≥20 mm Hg). RESULTS: A relatively smaller exponential decay in mean aortic gradient was found for increasing EOAi, as the slope on the log scale was -0.83 versus -2.5 in the publication from which the current cut-offs for PPM originate. The accuracy of the American Society of Echocardiography, Valve Academic Research Consortium-2, and European Association of Cardiovascular Imaging definitions of PPM to reflect elevated mean aortic gradients was 49%, 57%, and 57%, respectively. The relation between EOAi and mean aortic gradient was not significantly different between obese and non-obese patients (P = .20). CONCLUSIONS: The use of EOAi thresholds to classify patients with PPM is undermined by a less-pronounced exponential relationship between EOAi and mean aortic gradient than previously demonstrated. Moreover, recent adjustment for obesity in the definition of PPM is not supported by these data.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Ensayos Clínicos como Asunto , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Obesidad/complicaciones , Factores de Riesgo , Resultado del Tratamiento
5.
J Thorac Cardiovasc Surg ; 161(1): 66-75.e4, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31864696

RESUMEN

OBJECTIVE: Several recent-generation surgical tissue valves have been found to have bleeding rates exceeding rates recommended by regulatory bodies. We explored bleeding events using data from the Pericardial Surgical Aortic Valve Replacement (PERIGON) Pivotal Trial for the Avalus valve (Medtronic, Minneapolis, Minn) to examine whether this end point remains relevant for the evaluation of bioprostheses. METHODS: Patients (n = 1115) underwent aortic valve replacement. Bleeding and thromboembolic event episodes in patients within 3 years postimplant were analyzed for frequency, timing, and severity, focusing on patients taking antiplatelet/anticoagulant medications at the time of the event. Clinical and hemodynamic outcomes are also reported. RESULTS: At 3 years, the Kaplan-Meier cumulative probability estimate of all-cause death was 7.2% (cardiac, 3.6%; valve-related, 1.1%). The Kaplan-Meier cumulative probability estimates of all and major hemorrhage were 8.7% and 5.2%, respectively. Ninety-nine bleeding events occurred in 86 patients: most occurred >30 days postsurgery. Among the 51 late major bleeds, in 5 cases the patients were taking anticoagulant/antiplatelet medication for prophylaxis after surgical aortic valve replacement at the time of the event, whereas the remaining patients were taking medications for other reasons. Age (hazard ratio, 1.035; 95% confidence interval, 1.004-1.068), peripheral vascular disease (hazard ratio, 2.135; 95% confidence interval, 1.106-4.122), renal dysfunction (hazard ratio, 1.920; 95% confidence interval, 1.055-3.494), and antithrombotic medication use at the time of the event (hazard ratio, 1.417; 95% confidence interval, 1.048-1.915) were associated with late bleeds (major and minor). CONCLUSIONS: Overall clinical outcomes demonstrated low mortality and few complications except for major bleeding. Most bleeding events occurred >30 days after surgery and in patients taking antiplatelet and/or anticoagulation for indications other than postimplant prophylaxis.

6.
J Thorac Cardiovasc Surg ; 160(2): 371-381.e4, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31590957

RESUMEN

OBJECTIVES: The study objectives were to evaluate the safety, efficacy, and hemodynamic performance of a novel stented bovine pericardial aortic valve bioprosthesis 2 years after implantation. METHODS: The PERIcardial SurGical AOrtic Valve ReplacemeNT Pivotal Trial enrolled patients with symptomatic moderate/severe aortic stenosis or regurgitation at centers in Canada, Europe, and the United States. We report the outcomes and hemodynamic performance in patients with up to 2 years of follow-up. RESULTS: A total of 1273 patients were enrolled, and 1110 underwent implantation. Among patients undergoing implantation, the mean age was 70.2 ± 8.9 years; 833 (75.0%) were male. Risk of mortality (Society of Thoracic Surgeons) was 2.0% ± 1.4%. At the time of analysis, 604 patients had completed the 2-year follow-up visit. Linearized late event rates were as follows: all death, 2.68%; valve-related death, 0.42%; valve thrombosis, 0.05%; endocarditis, 0.94%; thromboembolism, 1.68%; all hemorrhage, 2.94%; major hemorrhage, 1.99%; all paravalvular leak, 0.26%; and major paravalvular leak, 0.05% per patient-year. Mean 2-year aortic gradient and effective orifice area were 13.4 ± 5.0 mm Hg and 1.5 ± 0.37 cm2, respectively. Moderate and severe prosthesis-patient mismatch were observed in 43.5% and 34.8% of patients at 2 years, respectively. Improvement in New York Heart Association class compared with baseline was observed in 73.0% with moderate mismatch and 74.1% with severe mismatch. CONCLUSIONS: The Avalus (Medtronic, Minneapolis, Minn) bovine pericardial valve demonstrates good clinical and safety outcomes at 2 years. Hemodynamic performance shows mean gradients comparable to currently available bovine pericardial aortic valves. There was no clinical impact of moderate to severe mismatch at 2 years. Further follow-up is required to evaluate midterm to long-term clinical outcome.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Pericardio/trasplante , Stents , Anciano , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Canadá , Bovinos , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Xenoinjertos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA