Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMJ Qual Saf ; 33(2): 132-135, 2024 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-38071526

RESUMEN

Studying near-miss errors is essential to preventing errors from reaching patients. When an error is committed, it may be intercepted (near-miss) or it will reach the patient; estimates of the proportion that reach the patient vary widely. To better understand this relationship, we conducted a retrospective cohort study using two objective measures to identify wrong-patient imaging order errors involving radiation, estimating the proportion of errors that are intercepted and those that reach the patient. This study was conducted at a large integrated healthcare system using data from 1 January to 31 December 2019. The study used two outcome measures of wrong-patient orders: (1) wrong-patient orders that led to misadministration of radiation reported to the New York Patient Occurrence Reporting and Tracking System (NYPORTS) (misadministration events); and (2) wrong-patient orders identified by the Wrong-Patient Retract-and-Reorder (RAR) measure, a measure identifying orders placed for a patient, retracted and rapidly reordered by the same clinician on a different patient (near-miss events). All imaging orders that involved radiation were extracted retrospectively from the healthcare system data warehouse. Among 293 039 total eligible orders, 151 were wrong-patient orders (3 misadministration events, 148 near-miss events), for an overall rate of 51.5 per 100 000 imaging orders involving radiation placed on the wrong patient. Of all wrong-patient imaging order errors, 2% reached the patient, translating to 50 near-miss events for every 1 error that reached the patient. This proportion provides a more accurate and reliable estimate and reinforces the utility of systematic measure of near-miss errors as an outcome for preventative interventions.


Asunto(s)
Prestación Integrada de Atención de Salud , Humanos , Estudios Retrospectivos , New York
2.
Nat Commun ; 14(1): 2555, 2023 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-37137888

RESUMEN

Neurons in the cerebral cortex fire coincident action potentials during ongoing activity and in response to sensory inputs. These synchronized cell assemblies are fundamental to cortex function, yet basic dynamical aspects of their size and duration are largely unknown. Using 2-photon imaging of neurons in the superficial cortex of awake mice, we show that synchronized cell assemblies organize as scale-invariant avalanches that quadratically grow with duration. The quadratic avalanche scaling was only found for correlated neurons, required temporal coarse-graining to compensate for spatial subsampling of the imaged cortex, and suggested cortical dynamics to be critical as demonstrated in simulations of balanced E/I-networks. The corresponding time course of an inverted parabola with exponent of χ = 2 described cortical avalanches of coincident firing for up to 5 s duration over an area of 1 mm2. These parabolic avalanches maximized temporal complexity in the ongoing activity of prefrontal and somatosensory cortex and in visual responses of primary visual cortex. Our results identify a scale-invariant temporal order in the synchronization of highly diverse cortical cell assemblies in the form of parabolic avalanches.


Asunto(s)
Corteza Cerebral , Modelos Neurológicos , Ratones , Animales , Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/fisiología , Neuronas/fisiología , Potenciales de Acción/fisiología , Vigilia , Sincronización Cortical
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA