Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Surg Res ; 291: 116-123, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37356340

RESUMEN

INTRODUCTION: Vascular reconstruction requires technical expertise and is often time consuming. As a novel alternative to traditional hand-sewn vascular anastomoses, the VasoLock (VL), is a nonabsorbable, sutureless anastomosis device with traction anchors designed to hold free artery ends together. These anchors do not penetrate the vessel wall but adhere by leveraging the elasticity of the vessels to fasten blood vessels together. This pilot study assesses the performance and patency of this novel device in a porcine model of femoral artery injury. METHODS: Female swine (n = 7) underwent femoral artery exposure for a total of 10 VL implanted. Study animals underwent hemodilution to a target hematocrit of 15% and ROTEM was used to assess coagulopathy, followed by an arterial injury via transection. The VL was inserted without any sutures. Flow-probe monitors were positioned proximal and distal to the device and flow rates were measured continuously for a total of 90 min. Flow was analyzed and presented as a ratio of distal to proximal flow with the slope of this ratio across time subsequently determined. Angiographic assessment was completed to evaluate for patency and technical complications after 90 min of implant. RESULTS: The average animal weight was 44.1 ± 3.2 kg. The average mean arterial pressure at the time of implant was 51.2 ± 7.8 mmHg, median heart rate was 77.4 (IQR = 77.25-157.4) beats per minute, and average temperature was 36.1 ± 1.5°C. The baseline hematocrit was 13.5 ± 3.0%, average pH was 7.20 ± 0.1, average clotting time was 154.1 ± 58.7 s and average clot formation time was 103.4 ± 10.9 s all demonstrating the acidotic, hypothermic, and coagulopathic state of the swine at the time of insertion. During the 90-min observation period, the average flow gradient identified across the VL was 0.99 ± 0.24, indicating no significant change in flow across the VL. The average slope of the gradients was 0.0005 (P = 0.22), suggesting the ratio of proximal and distal flow did not change over the 90 min. Following 90 min of dwell time, all VL were patent without technical complication. Angiographic assessment at 90 min demonstrated no evidence of dissection, device migration, arterial extravasation, or thromboembolism with any of the 10 devices. CONCLUSIONS: This pilot study demonstrated technical feasibility of the novel VL device over a 90-min observation period. All VL were patent and no negative events or complications were identified. This technology demonstrated significant promise in a coagulopathic state: additional investigation, involving long-term survival, is warranted for further validation.


Asunto(s)
Arteria Femoral , Femenino , Animales , Porcinos , Prueba de Estudio Conceptual , Proyectos Piloto , Grado de Desobstrucción Vascular , Anastomosis Quirúrgica , Arteria Femoral/cirugía
2.
Vascular ; 31(4): 777-783, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35430941

RESUMEN

INTRODUCTION: The use of antiplatelet (AP) and anticoagulation (AC) therapy after autogenous vein repair of traumatic arterial injury is controversial. The hypothesis in this study was that there is no difference in early postoperative outcomes regardless of whether AC, AP, both, or neither are used. METHODS: The American Association for the Surgery of Trauma (AAST) PROspective Observational Vascular Injury Treatment (PROOVIT) registry was queried from November, 2013, to January, 2019, for arterial injuries repaired with a vein graft. Demographics and injury characteristics were compared. Need for in-hospital reoperation was the primary outcome in this four-arm study, assessed with two ordinal logistic regression models (1. no therapy vs. AC only vs. AC and AP; 2. no therapy vs. AP only vs. AC and AP). RESULTS: 373 patients (52 no therapy, 88 AP only, 77 AC only, 156 both) from 19 centers with recorded Injury Severity Scores (ISS) were identified. Patients who received no therapy were younger than those who received AP (27.0 vs. 34.2, p = 0.02), had higher transfusion requirement (p < 0.01 between all groups) and a different distribution of anatomic injury (p < 0.01). After controlling for age, sex, ISS, platelet count, hemoglobin, pH, lactate, INR, transfusion requirement and anatomic location, there was no association with postoperative medical therapy and in-hospital operative reintervention, or any secondary outcome, including thrombosis (p = 0.67, p = 0.22). CONCLUSIONS: Neither AC nor AP alone, nor in combination, impact complication rate after arterial repair with autologous vein. These patients can be safely treated with or without antithrombotics, recognizing that this study did not demonstrate a beneficial effect.


Asunto(s)
Lesiones del Sistema Vascular , Humanos , Lesiones del Sistema Vascular/cirugía , Procedimientos Quirúrgicos Vasculares , Arterias/cirugía , Estudios Prospectivos , Anticoagulantes , Resultado del Tratamiento , Estudios Retrospectivos
3.
Mil Med ; 189(3-4): e612-e619, 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-37632757

RESUMEN

INTRODUCTION: Shock states that occur during, for example, profound hemorrhage can cause global tissue hypoperfusion leading to organ failure. There is an unmet need for a reliable marker of tissue perfusion during hemorrhage that can be followed longitudinally. Herein, we investigated whether longitudinal POMCO2 tracks changes in hemodynamics in a swine model of coagulopathic uncontrolled junctional hemorrhage. MATERIALS AND METHODS: Female Yorkshire-crossbreed swine (n = 7, 68.1 ± 0.7 kg) were anesthetized and instrumented for continuous measurement of mean arterial pressure (MAP). Coagulopathy was induced by the exchange of 50 to 60% of blood volume with 6% Hetastarch over 30 minutes to target a hematocrit of <15%. A 4.5-mm arteriotomy was made in the right common femoral artery with 30 seconds of free bleeding. POMCO2 was continuously measured from baseline through hemodilution, hemorrhage, and a subsequent 3-h intensive care unit period. Rotational thromboelastometry and blood gases were measured. RESULTS: POMCO2 and MAP showed no significant changes during the hemodilution phase of the experiment, which produced coagulopathy evidenced by prolonged clot formation times. However, POMCO2 increased because of the uncontrolled hemorrhage by 11.3 ± 3.1 mmHg and was inversely correlated with the drop (17.9 ± 5.9 mmHg) in MAP (Y = -0.4122*X + 2.649, P = .02, r2 = 0.686). In contrast, lactate did not significantly correlate with the changes in MAP (P = .35) or POMCO2 (P = .37). CONCLUSIONS: Despite the logical appeal of measuring noninvasive tissue CO2 measurement as a surrogate for gastrointestinal perfusion, prior studies have only reported snapshots of this readout. The present investigation shows real-time longitudinal measurement of POMCO2 to confirm that MAP inversely correlates to POMCO2 in the face of coagulopathy. The simplicity of measuring POMCO2 in real time can provide an additional practical option for military or civilian medics to monitor trends in hypoperfusion during hemorrhagic shock.


Asunto(s)
Trastornos de la Coagulación Sanguínea , Choque Hemorrágico , Porcinos , Femenino , Animales , Presión Sanguínea/fisiología , Dióxido de Carbono , Hemorragia , Hemodinámica/fisiología , Trastornos de la Coagulación Sanguínea/etiología , Ácido Láctico , Modelos Animales de Enfermedad
4.
J Trauma Acute Care Surg ; 95(2S Suppl 1): S144-S151, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37259206

RESUMEN

BACKGROUND: Hemostatic dressings are used extensively in both military and civilian trauma to control lethal noncompressible hemorrhage. The ideal topical hemostatic agent would provide reliable hemostasis in patients with profound acidosis, coagulopathy, and shock. This study aimed to compare next-generation hemostatic agents against the current military standard in a translational swine model of vascular injury and coagulopathy. METHODS: Female Yorkshire swine were randomized to eight groups (total n = 63; control n = 14, per group n = 7) of hemostatic agents and included: QuikClot Combat Gauze (Teleflex, Morrisville, NC), which served as the control; BloodSTOP IX (LifeScience Plus, Mountain View, CA); Celox Rapid (Medtrade Product, Crewe, United Kingdom); ChitoSAM 100 (Sam Medical, Tualatin, OR); EVARREST Fibrin Sealant Patch (Ethicon, Raritan, NJ); TAC Wrapping Gauze (H&H Medical, Williamsburg, VA); ChitoGauze XR Pro (Tricol Biomedical, Portland, OR); and X-Stat 30 (RevMedX, Wilsonville, OR). Hemodilution via exchange transfusion of 6% hetastarch was performed to induce acidosis and coagulopathy. An arteriotomy was created, allowing 30 seconds of free bleeding followed by application of the hemostatic agent and compression via an external compression device. A total of three applications were allowed for continued/recurrent bleeding. All blood loss was collected, and hemostatic agents were weighed to calculate blood volume loss. Following a 180-minute observation period, angiography was completed to evaluate for technical complication and distal perfusion of the limb. Finally, the limb was ranged five times to assess for rebleeding and clot stability. RESULTS: All swine were confirmed coagulopathic with rotational thromboelastography and acidotic (pH 7.2 ± 0.02). BloodSTOP IX allowed a significant increase in blood loss and number of applications required to obtain hemostasis compared with all other groups. BloodSTOP IX demonstrated a decreased survival rate (29%, p = 0.02). All mortalities were directly attributed to exsanguination as a result of device failure. In surviving animals, there was no difference in extravasation. BloodSTOP IX had an increased rebleeding rate after ranging compared with QuikClot Combat Gauze ( p = 0.007). CONCLUSION: Most novel hemostatic agents demonstrated comparable efficacy compared with the currently military standard hemostatic dressing, CG.


Asunto(s)
Acidosis , Trastornos de la Coagulación Sanguínea , Hemostáticos , Animales , Femenino , Vendajes , Trastornos de la Coagulación Sanguínea/terapia , Trastornos de la Coagulación Sanguínea/complicaciones , Modelos Animales de Enfermedad , Adhesivo de Tejido de Fibrina/uso terapéutico , Hemorragia/terapia , Hemorragia/etiología , Técnicas Hemostáticas , Hemostáticos/uso terapéutico , Porcinos
6.
Dalton Trans ; 43(43): 16498-508, 2014 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-25256407

RESUMEN

Eight bis-ligated, homoleptic, zinc complexes were synthesized through the reaction of NNO Schiff base ketoimines bearing varying substituents with diethyl zinc in an inert atmosphere glovebox at room temperature and isolated in 62-95% yield. The complexes were characterized with (1)H, (13)C, and (19)F nuclear magnetic resonance spectroscopy, absorbance spectroscopy, high resolution mass spectrometry, elemental analysis, and single crystal X-ray crystallography. The complexes were shown to adopt distorted octahedral coordination geometry around zinc. The (1)H and (19)F NMR spectra of complexes 1-7 showed stable zinc coordination at 300 K while the effect of steric encumbrance and two trifluoromethyl groups in complex 8 was investigated with variable temperature NMR. The bis-ligated zinc complexes were effective initiators for the ring opening polymerization of L-lactide into poly-L-lactic acid (PLLA). With [L-lac]/[Zn complex] = 50, the bis-ligated zinc complexes yielded percentage conversion of 14-98% with polymerization times varying from 15-1440 min, where the longest reaction times were required when two trifluoromethyl groups were present. The addition of 4-fluorophenol co-catalyst resulted in up to a 5-fold increase in the percentage conversion in toluene solution and up to a 14-fold increase in bulk melt polymerization with reductions in the poly-dispersity index values for the isolated PLLA. Addition of 4-fluorophenol to complex 1 was studied with (1)H and (19)F NMR and appeared to yield an in situ generated zinc alkoxide complex.


Asunto(s)
Complejos de Coordinación/química , Dioxanos/química , Iminas/química , Zinc/química , Complejos de Coordinación/síntesis química , Cristalografía por Rayos X , Ácido Láctico/química , Espectroscopía de Resonancia Magnética , Conformación Molecular , Poliésteres , Polimerizacion , Polímeros/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
7.
Dalton Trans ; 42(15): 5573-86, 2013 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-23435405

RESUMEN

A series of NNO ketoimines bearing trifluoromethyl substituents were synthesized from the Schiff base condensation of 1,3-diketones (1,1,1-trifluoro-5,5-dimethyl-2,4-hexanedione, 4,4,4-trifluoro-1-phenyl-1,3-butanedione, and 1,1,1-trifluoro-2,4-pentanedione, 1,1,1,5,5,5-hexafluoroacetylacetone) and 8-aminoquinoline or 8-amino-2-methylquinoline and isolated in 40-70% yield. The ketoimines were combined with zinc bis-(trimethylsilyl)amide to prepare a zinc amide complex in 41% yield or were combined with zinc bis-(trimethylsilyl)amide and 2,6-di-tert-butylphenol to prepare zinc phenoxide complexes in 81-94% yield. The ketoimines and zinc complexes were characterized with (1)H, (13)C, and (19)F NMR, absorbance spectroscopy, mass spectrometry, elemental analysis and X-ray crystallography. The mononuclear solid state structures of the zinc amide and phenoxide complexes showed tridentate coordination of the zinc center by the ketoiminate and monodentate coordination by the amide or phenoxide. The zinc complexes were assessed for their ability to catalyze the ring opening polymerization (ROP) of L-lactide into poly-lactic acid (PLA) with some complexes reaching 100% conversion in 3 h. As the monomer to catalyst ratio increased, the molecular weight of the isolated polymeric material increased in a nearly linear fashion while retaining a narrow molecular weight distribution. Homonuclear decoupled (1)H NMR spectra of the isolated polymeric material showed the retention of stereochemistry in the isotactic poly-L-lactic acid. Kinetic studies, where the substituents on the ketoiminate and quinolyl moiety were varied, showed that lower electron density on the Zn metal center yielded lower ROP catalytic activity than their electron rich counterparts. The complexes are proposed to use the coordination-insertion mechanism for living polymerization of L-lactide.


Asunto(s)
Complejos de Coordinación/química , Ácido Láctico/química , Zinc/química , Amidas/química , Complejos de Coordinación/síntesis química , Cristalografía por Rayos X , Iminas/síntesis química , Iminas/química , Cetonas/química , Cinética , Conformación Molecular , Óxidos/química , Poliésteres , Polimerizacion , Polímeros/química , Bases de Schiff/química , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA