Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Synchrotron Radiat ; 22(2): 201-12, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25723922

RESUMEN

Radiation damage impedes macromolecular diffraction experiments. Alongside the well known effects of global radiation damage, site-specific radiation damage affects data quality and the veracity of biological conclusions on protein mechanism and function. Site-specific radiation damage follows a relatively predetermined pattern, in that different structural motifs are affected at different dose regimes: in metal-free proteins, disulfide bonds tend to break first followed by the decarboxylation of aspartic and glutamic acids. Even within these damage motifs the decay does not progress uniformly at equal rates. Within the same protein, radiation-induced electron density decay of a particular chemical group is faster than for the same group elsewhere in the protein: an effect known as preferential specific damage. Here, BDamage, a new atomic metric, is defined and validated to recognize protein regions susceptible to specific damage and to quantify the damage at these sites. By applying BDamage to a large set of known protein structures in a statistical survey, correlations between the rates of damage and various physicochemical parameters were identified. Results indicate that specific radiation damage is independent of secondary protein structure. Different disulfide bond groups (spiral, hook, and staple) show dissimilar radiation damage susceptibility. There is a consistent positive correlation between specific damage and solvent accessibility.


Asunto(s)
Sustancias Macromoleculares/efectos de la radiación , Estructura Secundaria de Proteína/efectos de la radiación , Traumatismos por Radiación , Cristalografía por Rayos X/métodos , Relación Dosis-Respuesta en la Radiación , Humanos , Modelos Moleculares , Medicina Nuclear , Solventes
2.
J Synchrotron Radiat ; 20(Pt 1): 49-57, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23254655

RESUMEN

X-ray data collection for macromolecular crystallography can lead to highly inhomogeneous distributions of dose within the crystal volume for cases when the crystal is larger than the beam or when the beam is non-uniform (gaussian-like), particularly when crystal rotation is fully taken into account. Here the spatial distribution of dose is quantitatively modelled in order to compare the effectiveness of two dose-spreading data-collection protocols: helical scanning and translational collection. Their effectiveness in reducing the peak dose per unit diffraction is investigated via simulations for four common crystal shapes (cube, plate, long and short needles) and beams with a wide range of full width half maximum values. By inspection of the chosen metric, it is concluded that the optimum strategy is always to use as flat (top-hat) a beam as possible and to either match the beam size in both dimensions to the crystal, or to perform a helical scan with a beam which is narrow along the rotation axis and matched to the crystal size along the perpendicular axis. For crystal shapes where this is not possible, the reduction in peak dose per unit diffraction achieved through dose spreading is quantified and tabulated as a reference for experimenters.


Asunto(s)
Cristalografía por Rayos X/métodos , Sustancias Macromoleculares/efectos de la radiación , Dosis de Radiación , Simulación por Computador , Cristalografía , Modelos Teóricos , Distribución Normal , Rayos X
3.
Acta Crystallogr D Struct Biol ; 79(Pt 6): 449-461, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37259835

RESUMEN

The Collaborative Computational Project No. 4 (CCP4) is a UK-led international collective with a mission to develop, test, distribute and promote software for macromolecular crystallography. The CCP4 suite is a multiplatform collection of programs brought together by familiar execution routines, a set of common libraries and graphical interfaces. The CCP4 suite has experienced several considerable changes since its last reference article, involving new infrastructure, original programs and graphical interfaces. This article, which is intended as a general literature citation for the use of the CCP4 software suite in structure determination, will guide the reader through such transformations, offering a general overview of the new features and outlining future developments. As such, it aims to highlight the individual programs that comprise the suite and to provide the latest references to them for perusal by crystallographers around the world.


Asunto(s)
Proteínas , Programas Informáticos , Proteínas/química , Cristalografía por Rayos X , Sustancias Macromoleculares
4.
Protein Sci ; 31(1): 232-250, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34747533

RESUMEN

The DIALS software for the processing of X-ray diffraction data is presented, with an emphasis on how the suite may be used as a toolkit for data processing. The description starts with an overview of the history and intent of the toolkit, usage as an automated system, command-line use, and ultimately how new tools can be written using the API to perform bespoke analysis. Consideration is also made to the application of DIALS to techniques outside of macromolecular X-ray crystallography.


Asunto(s)
Procesamiento Automatizado de Datos , Programas Informáticos , Cristalografía por Rayos X
5.
Acta Crystallogr D Struct Biol ; 75(Pt 3): 242-261, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30950396

RESUMEN

Strategies for collecting X-ray diffraction data have evolved alongside beamline hardware and detector developments. The traditional approaches for diffraction data collection have emphasised collecting data from noisy integrating detectors (i.e. film, image plates and CCD detectors). With fast pixel array detectors on stable beamlines, the limiting factor becomes the sample lifetime, and the question becomes one of how to expend the photons that your sample can diffract, i.e. as a smaller number of stronger measurements or a larger number of weaker data. This parameter space is explored via experiment and synthetic data treatment and advice is derived on how best to use the equipment on a modern beamline. Suggestions are also made on how to acquire data in a conservative manner if very little is known about the sample lifetime.


Asunto(s)
Fotones , Difracción de Rayos X/métodos , Análisis de Datos , Recolección de Datos
6.
Acta Crystallogr D Struct Biol ; 74(Pt 2): 85-97, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-29533234

RESUMEN

The DIALS project is a collaboration between Diamond Light Source, Lawrence Berkeley National Laboratory and CCP4 to develop a new software suite for the analysis of crystallographic X-ray diffraction data, initially encompassing spot finding, indexing, refinement and integration. The design, core algorithms and structure of the software are introduced, alongside results from the analysis of data from biological and chemical crystallography experiments.


Asunto(s)
Algoritmos , Cristalografía por Rayos X/métodos , Procesamiento Automatizado de Datos/métodos , Programas Informáticos , Proteínas Bacterianas/química , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Proteínas Represoras/química , Termolisina/química
7.
Acta Crystallogr D Struct Biol ; 72(Pt 5): 648-57, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27139628

RESUMEN

Radiation damage during macromolecular X-ray crystallographic data collection is still the main impediment for many macromolecular structure determinations. Even when an eventual model results from the crystallographic pipeline, the manifestations of radiation-induced structural and conformation changes, the so-called specific damage, within crystalline macromolecules can lead to false interpretations of biological mechanisms. Although this has been well characterized within protein crystals, far less is known about specific damage effects within the larger class of nucleoprotein complexes. Here, a methodology has been developed whereby per-atom density changes could be quantified with increasing dose over a wide (1.3-25.0 MGy) range and at higher resolution (1.98 Å) than the previous systematic specific damage study on a protein-DNA complex. Specific damage manifestations were determined within the large trp RNA-binding attenuation protein (TRAP) bound to a single-stranded RNA that forms a belt around the protein. Over a large dose range, the RNA was found to be far less susceptible to radiation-induced chemical changes than the protein. The availability of two TRAP molecules in the asymmetric unit, of which only one contained bound RNA, allowed a controlled investigation into the exact role of RNA binding in protein specific damage susceptibility. The 11-fold symmetry within each TRAP ring permitted statistically significant analysis of the Glu and Asp damage patterns, with RNA binding unexpectedly being observed to protect these otherwise highly sensitive residues within the 11 RNA-binding pockets distributed around the outside of the protein molecule. Additionally, the method enabled a quantification of the reduction in radiation-induced Lys and Phe disordering upon RNA binding directly from the electron density.


Asunto(s)
Proteínas Bacterianas/química , Cristalografía por Rayos X/métodos , Geobacillus stearothermophilus/química , Conformación Proteica/efectos de la radiación , Proteínas de Unión al ARN/química , ARN/química , Factores de Transcripción/química , Proteínas Bacterianas/metabolismo , Geobacillus stearothermophilus/metabolismo , Modelos Moleculares , Unión Proteica , ARN/metabolismo , Proteínas de Unión al ARN/metabolismo , Factores de Transcripción/metabolismo , Rayos X/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA