Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Med Imaging ; 22(1): 103, 2022 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-35644612

RESUMEN

BACKGROUND: Melanoma is the most dangerous and aggressive form among skin cancers, exhibiting a high mortality rate worldwide. Biopsy and histopathological analysis are standard procedures for skin cancer detection and prevention in clinical settings. A significant step in the diagnosis process is the deep understanding of the patterns, size, color, and structure of lesions based on images obtained through dermatoscopes for the infected area. However, the manual segmentation of the lesion region is time-consuming because the lesion evolves and changes its shape over time, making its prediction challenging. Moreover, it is challenging to predict melanoma at the initial stage as it closely resembles other skin cancer types that are not malignant as melanoma; thus, automatic segmentation techniques are required to design a computer-aided system for accurate and timely detection. METHODS: As deep learning approaches have gained significant attention in recent years due to their remarkable performance, therefore, in this work, we proposed a novel design of a convolutional neural network (CNN) framework based on atrous convolutions for automatic lesion segmentation. This architecture is built based on the concept of atrous/dilated convolutions which are effective for semantic segmentation. A deep neural network is designed from scratch employing several building blocks consisting of convolutional, batch normalization, leakyReLU layer, and fine-tuned hyperparameters contributing altogether towards higher performance. CONCLUSION: The network was tested on three benchmark datasets provided by International Skin Imaging Collaboration (ISIC), i.e., ISIC 2016, ISIC 2017, and ISIC 2018. The experimental results showed that the proposed network achieved an average Jaccard index of 90.4% on ISIC 2016, 81.8% on ISIC 2017, and 89.1% on ISIC 2018 datasets, respectively which is recorded as higher than the top three winners of the ISIC challenge and other state-of-the-art methods. Also, the model successfully extracts lesions from the whole image in one pass in less time, requiring no pre-processing step. The conclusions yielded that network is accurate in performing lesion segmentation on adopted datasets.


Asunto(s)
Melanoma , Neoplasias Cutáneas , Dermoscopía/métodos , Humanos , Melanoma/diagnóstico por imagen , Redes Neurales de la Computación , Piel/diagnóstico por imagen , Neoplasias Cutáneas/diagnóstico por imagen
2.
Sensors (Basel) ; 22(3)2022 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35161878

RESUMEN

Automatic melanoma detection from dermoscopic skin samples is a very challenging task. However, using a deep learning approach as a machine vision tool can overcome some challenges. This research proposes an automated melanoma classifier based on a deep convolutional neural network (DCNN) to accurately classify malignant vs. benign melanoma. The structure of the DCNN is carefully designed by organizing many layers that are responsible for extracting low to high-level features of the skin images in a unique fashion. Other vital criteria in the design of DCNN are the selection of multiple filters and their sizes, employing proper deep learning layers, choosing the depth of the network, and optimizing hyperparameters. The primary objective is to propose a lightweight and less complex DCNN than other state-of-the-art methods to classify melanoma skin cancer with high efficiency. For this study, dermoscopic images containing different cancer samples were obtained from the International Skin Imaging Collaboration datastores (ISIC 2016, ISIC2017, and ISIC 2020). We evaluated the model based on accuracy, precision, recall, specificity, and F1-score. The proposed DCNN classifier achieved accuracies of 81.41%, 88.23%, and 90.42% on the ISIC 2016, 2017, and 2020 datasets, respectively, demonstrating high performance compared with the other state-of-the-art networks. Therefore, this proposed approach could provide a less complex and advanced framework for automating the melanoma diagnostic process and expediting the identification process to save a life.


Asunto(s)
Melanoma , Neoplasias Cutáneas , Dermoscopía , Humanos , Melanoma/diagnóstico por imagen , Redes Neurales de la Computación , Piel , Neoplasias Cutáneas/diagnóstico por imagen
3.
Sensors (Basel) ; 21(16)2021 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-34451119

RESUMEN

Pattern recognition algorithms have been widely used to map surface electromyographic signals to target movements as a source for prosthetic control. However, most investigations have been conducted offline by performing the analysis on pre-recorded datasets. While real-time data analysis (i.e., classification when new data becomes available, with limits on latency under 200-300 milliseconds) plays an important role in the control of prosthetics, less knowledge has been gained with respect to real-time performance. Recent literature has underscored the differences between offline classification accuracy, the most common performance metric, and the usability of upper limb prostheses. Therefore, a comparative offline and real-time performance analysis between common algorithms had yet to be performed. In this study, we investigated the offline and real-time performance of nine different classification algorithms, decoding ten individual hand and wrist movements. Surface myoelectric signals were recorded from fifteen able-bodied subjects while performing the ten movements. The offline decoding demonstrated that linear discriminant analysis (LDA) and maximum likelihood estimation (MLE) significantly (p < 0.05) outperformed other classifiers, with an average classification accuracy of above 97%. On the other hand, the real-time investigation revealed that, in addition to the LDA and MLE, multilayer perceptron also outperformed the other algorithms and achieved a classification accuracy and completion rate of above 68% and 69%, respectively.


Asunto(s)
Miembros Artificiales , Movimiento , Algoritmos , Electromiografía , Mano , Humanos , Articulación de la Muñeca
4.
Sensors (Basel) ; 19(22)2019 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-31752238

RESUMEN

Rapid detection and identification of industrial gases is a challenging problem. They have a complex composition and different specifications. This paper presents a method based on the kernel discriminant analysis (KDA) algorithm to identify industrial gases. The smell prints of four typical industrial gases were collected by an electronic nose. The extracted features of the collected gases were employed for gas identification using different classification algorithms, including principal component analysis (PCA), linear discriminant analysis (LDA), PCA + LDA, and KDA. In order to obtain better classification results, we reduced the dimensions of the original high-dimensional data, and chose a good classifier. The KDA algorithm provided a high classification accuracy of 100% by selecting the offset of the kernel function c = 10 and the degree of freedom d = 5. It was found that this accuracy was 4.17% higher than the one obtained using PCA. In the case of standard deviation, the KDA algorithm has the highest recognition rate and the least time consumption.

5.
J Med Syst ; 43(8): 233, 2019 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-31203472

RESUMEN

This review aims to present current advancements in wearable technologies and IoT-based applications to support independent living. The secondary aim was to investigate the barriers and challenges of wearable sensors and Internet-of-Things (IoT) monitoring solutions for older adults. For this work, we considered falls and activity of daily life (ADLs) for the ageing population (older adults). A total of 327 articles were screened, and 14 articles were selected for this review. This review considered recent studies published between 2015 and 2019. The research articles were selected based on the inclusion and exclusion criteria, and studies that support or present a vision to provide advancement to the current space of ADLs, independent living and supporting the ageing population. Most studies focused on the system aspects of wearable sensors and IoT monitoring solutions including advanced sensors, wireless data collection, communication platform and usability. Moderate to low usability/ user-friendly approach is reported in most of the studies. Other issues found were inaccurate sensors, battery/ power issues, restricting the users within the monitoring area/ space and lack of interoperability. The advancement of wearable technology and the possibilities of using advanced IoT technology to assist older adults with their ADLs and independent living is the subject of many recent research and investigation.


Asunto(s)
Vida Independiente , Monitoreo Fisiológico/instrumentación , Dispositivos Electrónicos Vestibles , Anciano , Humanos , Aplicaciones Móviles
6.
Sensors (Basel) ; 17(5)2017 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-28486407

RESUMEN

This paper provides a review of the most recent works in machine olfaction as applied to the identification of Chinese Herbal Medicines (CHMs). Due to the wide variety of CHMs, the complexity of growing sources and the diverse specifications of herb components, the quality control of CHMs is a challenging issue. Much research has demonstrated that an electronic nose (E-nose) as an advanced machine olfaction system, can overcome this challenge through identification of the complex odors of CHMs. E-nose technology, with better usability, high sensitivity, real-time detection and non-destructive features has shown better performance in comparison with other analytical techniques such as gas chromatography-mass spectrometry (GC-MS). Although there has been immense development of E-nose techniques in other applications, there are limited reports on the application of E-noses for the quality control of CHMs. The aim of current study is to review practical implementation and advantages of E-noses for robust and effective odor identification of CHMs. It covers the use of E-nose technology to study the effects of growing regions, identification methods, production procedures and storage time on CHMs. Moreover, the challenges and applications of E-nose for CHM identification are investigated. Based on the advancement in E-nose technology, odor may become a new quantitative index for quality control of CHMs and drug discovery. It was also found that more research could be done in the area of odor standardization and odor reproduction for remote sensing.


Asunto(s)
Medicamentos Herbarios Chinos , Nariz Electrónica , Cromatografía de Gases y Espectrometría de Masas , Humanos , Odorantes , Control de Calidad
7.
J Med Syst ; 41(7): 115, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28631139

RESUMEN

The aim of this review is to investigate barriers and challenges of wearable patient monitoring (WPM) solutions adopted by clinicians in acute, as well as in community, care settings. Currently, healthcare providers are coping with ever-growing healthcare challenges including an ageing population, chronic diseases, the cost of hospitalization, and the risk of medical errors. WPM systems are a potential solution for addressing some of these challenges by enabling advanced sensors, wearable technology, and secure and effective communication platforms between the clinicians and patients. A total of 791 articles were screened and 20 were selected for this review. The most common publication venue was conference proceedings (13, 54%). This review only considered recent studies published between 2015 and 2017. The identified studies involved chronic conditions (6, 30%), rehabilitation (7, 35%), cardiovascular diseases (4, 20%), falls (2, 10%) and mental health (1, 5%). Most studies focussed on the system aspects of WPM solutions including advanced sensors, wireless data collection, communication platform and clinical usability based on a specific area or disease. The current studies are progressing with localized sensor-software integration to solve a specific use-case/health area using non-scalable and 'silo' solutions. There is further work required regarding interoperability and clinical acceptance challenges. The advancement of wearable technology and possibilities of using machine learning and artificial intelligence in healthcare is a concept that has been investigated by many studies. We believe future patient monitoring and medical treatments will build upon efficient and affordable solutions of wearable technology.


Asunto(s)
Monitoreo Fisiológico , Inteligencia Artificial , Atención a la Salud , Humanos , Programas Informáticos
8.
Aging Clin Exp Res ; 28(6): 1159-1168, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26786585

RESUMEN

Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way healthcare is currently delivered. Currently hospital falls are a major healthcare concern worldwide because of the ageing population. Current observational data and vital signs give the critical information related to the patient's physiology, and motion data provide an additional tool in falls risk assessment. These data combined with the patient's medical history potentially may give the interpretation model high information accessibility to predict falls risk. This study aims to develop a robust falls risk assessment system, in order to avoid falls and its related long-term disabilities in hospitals especially among older adults. The proposed system employs real-time vital signs, motion data, falls history and other clinical information. The falls risk assessment model has been tested and evaluated with 30 patients. The results of the proposed system have been compared with and evaluated against the hospital's falls scoring scale.


Asunto(s)
Accidentes por Caídas , Envejecimiento/fisiología , Hospitalización , Medición de Riesgo/métodos , Anciano , Humanos , Persona de Mediana Edad , Modelos Teóricos , Examen Físico
9.
J Med Syst ; 37(2): 9898, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23321968

RESUMEN

Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.


Asunto(s)
Monitoreo Ambulatorio/métodos , Tecnología de Sensores Remotos , Telemedicina/instrumentación , Tecnología Inalámbrica/organización & administración , Confidencialidad , Humanos , Telemedicina/métodos
10.
Heliyon ; 9(8): e18717, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37560695

RESUMEN

Objectives: The aim of this study was to analyse the current use, identify challenges and barriers and propose a way forward for the use of the pager devices in the in-hospital communications. Methods: Initially, 447 studies were identified through database searching. After checking against the eligibility, 39 studies were included. Full-text records were retrieved and reviewed by two authors. After excluding unrelated studies and duplicate records, a total of 12 articles were selected for the final review. Results: The use of pagers often lacks standardisation, content, format, urgency level, and clarity within the message. Some studies reported that medical staff preferred in-person interactions with consults instead of communicating over the phone or pagers. Productive communication can reduce the turnaround time by up to 50%. The key challenges are; (1) data security and privacy, (2) timely acknowledgement of received communication, (3) lack of two-way communications causing issues in critical care situations and (4) there is no standard process for the in-hospital communications. Conclusion: We found that the clinicians' age, experience, speciality and preferences greatly matter and influence the selection of tools and technology in healthcare. With revolutionary advances in technology, smartphones have inevitably become beneficial to healthcare, owing to multiple instant messaging applications (apps) that can streamline encrypted clinical communication between medical teams and could be safely used for in-hospital communications.

11.
Heliyon ; 8(2): e08944, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35243066

RESUMEN

We performed FMEA on the existing RRS with the help of routine users of the RRS who acted as subject matter experts and evaluated the failures for their criticality using the Risk Priority Number approach based on their experience of the RRS. The FMEA found 35 potential failure modes and 101 failure mode effects across 13 process steps of the RRS. The afferent limb of RRS was found to be more prone to these failures (62, 61.4%) than the efferent limb of the RRS (39, 38.6%). Modification of calling criteria (12, 11.9%) and calculation of New Zealand Early Warning Scores (NZEWS) calculation (11, 10.9%) steps were found to potentially give rise to the highest number of these failures. Causes of these failures include human error and related factors (35, 34.7%), staff workload/staffing levels (30, 29.7%) and limitations due to paper-based charts and organisational factors (n = 30, 29.7%). The demonstrated electronic system was found to potentially eliminate or reduce the likelihood of 71 (70.2%) failures. The failures not eliminated by the electronic RRS require targeted corrective measures including scenario-based training and education, and revised calling criteria to include triggers for hypothermia and high systolic blood pressure.

12.
Heliyon ; 8(10): e11182, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36325132

RESUMEN

Aims and objectives: This study investigated clinical staff perceptions of learning about current monitoring practices and the planned introduction of an electronic system for patient monitoring. The aim of this research was to evaluate the perceptions of clinical staff (nurses and doctors) about the perceived strengths and weaknesses of the current state of the rapid response system (RRS) and how those strengths and weakness would be affected by introducing an electronic RRS. Methods: This research applied a descriptive study methodology. Two detailed sessions on demonstration on the electronic RRS for measuring and recording vital signs and the electronic Early Warning System (EWS) were followed by two structured surveys administered through an online portal (SurveyMonkey) for nurses and doctors working at Taranaki District Health Board. The study was planned and conducted between October 2020 and May 2021 at Taranaki Base Hospital, New Plymouth, New Zealand. Results: We found that the perceptions of clinical staff were a combination of key practice issues with current manual monitoring, expectations of improved visibility of vital sign charts, better communication between staff and thus improved patient care with the introduction of an electronic system. A majority (24, 60%) of nurses reported that, when called to assess deteriorating patients, the responders arrive at bedside within 5-30 min and an additional 11 (27%) said the responders arrive within 5 min. That is a collective 87% responder arrival within 30 min. Conclusion: Staff believe that an electronic RRS could improve communication, speed up decision making and have a positive impact on patient outcomes.

13.
Heliyon ; 8(10): e10955, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36254295

RESUMEN

Objective: This study aimed to quantify the workload involved in patient monitoring by vital signs and early warning scores (EWS), and the time spent by a rapid response team locally known as the Patient-at-Risk (PaR) team in responding to deteriorating patients. Methods: The workload involved in the measurement and the documentation of vital signs and EWS was quantified by time and motion study using electronic stopwatch application in 167 complete sets of vital signs observations taken by nursing staff on general hospital wards at Taranaki Base Hospital, New Plymouth, New Zealand. The workload involved in responding to deteriorating patients was measured by the PaR team in real-time and recorded in an electronic logbook specifically designed for this purpose. Dependent variables were studied using analysis of variance (ANOVA), post hoc Tukey, Kruskal Wallis test, Mann-Whitney test and correlation tests. Results: The mean time to measure and record a complete set of vital signs including interruptions was 4:18 (95% CI: 4:07-4:28) minutes. After excluding interruptions, the mean time taken to measure and record a set of vital signs was 3:24 (95% CI: 3:15-3:33) minutes. We found no statistical difference between the observer, location of the patient, staff characteristics or experience and patient characteristics. PaR nurses' mean time to provide rapid response was 47:36 (95% CI: 44:57-50:15) minutes. Significantly more time was spent on patients having severe degrees of deterioration (higher EWS) < 0.001. No statistical difference was observed between ward specialty, and nursing shifts. Conclusions: Patient monitoring and response to deterioration consumed considerable time. Time spent in monitoring was not affected by independent and random factors studied; however, time spent on the response was greater when patients had higher degrees of deterioration.

14.
J Clin Monit Comput ; 25(5): 339-47, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22033574

RESUMEN

OBJECTIVE: Humans have a limited ability to accurately and continuously analyse large amount of data. In recent times, there has been a rapid growth in patient monitoring and medical data analysis using smart monitoring systems. Fuzzy logic-based expert systems, which can mimic human thought processes in complex circumstances, have indicated potential to improve clinicians' performance and accurately execute repetitive tasks to which humans are ill-suited. The main goal of this study is to develop a clinically useful diagnostic alarm system based on fuzzy logic for detecting critical events during anaesthesia administration. METHOD: The proposed diagnostic alarm system called fuzzy logic monitoring system (FLMS) is presented. New diagnostic rules and membership functions (MFs) are developed. In addition, fuzzy inference system (FIS), adaptive neuro fuzzy inference system (ANFIS), and clustering techniques are explored for developing the FLMS' diagnostic modules. The performance of FLMS which is based on fuzzy logic expert diagnostic systems is validated through a series of off-line tests. The training and testing data set are selected randomly from 30 sets of patients' data. RESULTS: The accuracy of diagnoses generated by the FLMS was validated by comparing the diagnostic information with the one provided by an anaesthetist for each patient. Kappa-analysis was used for measuring the level of agreement between the anaesthetist's and FLMS's diagnoses. When detecting hypovolaemia, a substantial level of agreement was observed between FLMS and the human expert (the anaesthetist) during surgical procedures. CONCLUSION: The diagnostic alarm system FLMS demonstrated that evidence-based expert diagnostic systems can diagnose hypovolaemia, with a substantial degree of accuracy, in anaesthetized patients and could be useful in delivering decision support to anaesthetists.


Asunto(s)
Anestesia/métodos , Sistemas Especialistas , Lógica Difusa , Monitoreo Fisiológico/métodos , Anestesiología/tendencias , Análisis por Conglomerados , Técnicas de Apoyo para la Decisión , Medicina Basada en la Evidencia , Humanos , Hipovolemia/diagnóstico
15.
Appl Clin Inform ; 12(1): 1-9, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33406540

RESUMEN

BACKGROUND: Prediabetes and type 2 diabetes mellitus (T2DM) are one of the major long-term health conditions affecting global healthcare delivery. One of the few effective approaches is to actively manage diabetes via a healthy and active lifestyle. OBJECTIVES: This research is focused on early detection of prediabetes and T2DM using wearable technology and Internet-of-Things-based monitoring applications. METHODS: We developed an artificial intelligence model based on adaptive neuro-fuzzy inference to detect prediabetes and T2DM via individualized monitoring. The key contributing factors to the proposed model include heart rate, heart rate variability, breathing rate, breathing volume, and activity data (steps, cadence, and calories). The data was collected using an advanced wearable body vest and combined with manual recordings of blood glucose, height, weight, age, and sex. The model analyzed the data alongside a clinical knowledgebase. Fuzzy rules were used to establish baseline values via existing interventions, clinical guidelines, and protocols. RESULTS: The proposed model was tested and validated using Kappa analysis and achieved an overall agreement of 91%. CONCLUSION: We also present a 2-year follow-up observation from the prediction results of the original model. Moreover, the diabetic profile of a participant using M-health applications and a wearable vest (smart shirt) improved when compared to the traditional/routine practice.


Asunto(s)
Diabetes Mellitus Tipo 2 , Estado Prediabético , Dispositivos Electrónicos Vestibles , Inteligencia Artificial , Diabetes Mellitus Tipo 2/diagnóstico , Humanos , Internet , Estado Prediabético/diagnóstico
16.
Inform Health Soc Care ; 46(2): 148-157, 2021 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-33472485

RESUMEN

AIM: The aim of this study was to investigate the effectiveness of current rapid response applications available in acute care settings for escalation of patient deterioration. Current challenges and barriers, as well as key recommendations, were also discussed. METHODS: We adopted PRISMA review methodology and screened a total of 559 articles. After considering the eligibility and selection criteria, we selected 13 articles published between 2015 and 2019. The selection criteria were based on the inclusion of studies that report on the advancement made to the current practice for providing rapid response to the patient deterioration in acute care settings. RESULTS: We found that current rapid response applications are complicated and time-consuming for detecting inpatient deterioration. Existing applications are either siloed or challenging to use, where clinicians are required to move between two or three different applications to complete an end-to-end patient escalation workflow - from vital signs collection to escalation of deteriorating patients. We found significant differences in escalation and responses when using an electronic tool compared to the manual approach. Moreover, encouraging results were reported in extensive documentation of vital signs and timely alerts for patient deterioration. CONCLUSION: The electronic vital signs monitoring applications are proved to be efficient and clinically suitable if they are user-friendly and interoperable. As an outcome, several key recommendations and features were identified that would be crucial to the successful implementation of any rapid response system in all clinical settings.


Asunto(s)
Puntuación de Alerta Temprana , Pacientes Internos , Documentación , Humanos
17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 5132-5135, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-33019141

RESUMEN

M-health applications are playing an important role in current healthcare delivery, individual's health and well-being. Usability of mHealth applications (apps) is a critical factor for the success of the apps, yet this is often overlooked in the current health care solutions in primary care, secondary (acute) care, community care and especially in remote patient monitoring applications. This work aimed to co-design the vital signs monitoring application with end-users and clinicians. The co-design user-experience includes goals and objectives, participant inclusion and exclusion criteria, task list, testing documentation, laboratory-based usability testing and data analysis for identifying gaps and opportunities. The study found two main issues from the usability analysis, presentation of the information such as use of icons, text and graphs and clinical workflow related matters such as the number of mandatory steps required to finish a task.


Asunto(s)
Aplicaciones Móviles , Telemedicina , Cuidados Críticos , Humanos , Monitoreo Fisiológico , Flujo de Trabajo
18.
Med Biol Eng Comput ; 58(1): 83-100, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31754982

RESUMEN

Myoelectric pattern recognition (MPR) to decode limb movements is an important advancement regarding the control of powered prostheses. However, this technology is not yet in wide clinical use. Improvements in MPR could potentially increase the functionality of powered prostheses. To this purpose, offline accuracy and processing time were measured over 44 features using six classifiers with the aim of determining new configurations of features and classifiers to improve the accuracy and response time of prosthetics control. An efficient feature set (FS: waveform length, correlation coefficient, Hjorth Parameters) was found to improve the motion recognition accuracy. Using the proposed FS significantly increased the performance of linear discriminant analysis, K-nearest neighbor, maximum likelihood estimation (MLE), and support vector machine by 5.5%, 5.7%, 6.3%, and 6.2%, respectively, when compared with the Hudgins' set. Using the FS with MLE provided the largest improvement in offline accuracy over the Hudgins feature set, with minimal effect on the processing time. Among the 44 features tested, logarithmic root mean square and normalized logarithmic energy yielded the highest recognition rates (above 95%). We anticipate that this work will contribute to the development of more accurate surface EMG-based motor decoding systems for the control prosthetic hands.


Asunto(s)
Algoritmos , Electromiografía , Mano/fisiología , Movimiento/fisiología , Adulto , Humanos , Persona de Mediana Edad , Análisis de Componente Principal , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Adulto Joven
19.
Artículo en Inglés | MEDLINE | ID: mdl-31677058

RESUMEN

High blood pressure (BP) or hypertension is the single most crucial adjustable risk factor for cardiovascular diseases (CVDs) and monitoring the arterial blood pressure (ABP) is an efficient way to detect and control the prevalence of the cardiovascular health of patients. Therefore, monitoring the regulation of BP during patients' daily life plays a critical role in the ambulatory setting and the latest mobile health technology. In recent years, many studies have been conducted to explore the feasibility and performance of such techniques in the health care system. The ultimate aim of these studies is to find and develop an alternative to conventional BP monitoring by using cuff-less, easy-to-use, fast, and cost-effective devices for controlling and lowering the physical harm of CVDs to the human body. However, most of the current studies are at the prototype phase and face a range of issues and challenges to meet clinical standards. This review focuses on the description and analysis of the latest continuous and cuff-less methods along with their key challenges and barriers. Particularly, most advanced and standard technologies including pulse transit time (PTT), ultrasound, pulse arrival time (PAT), and machine learning are investigated. The accuracy, portability, and comfort of use of these technologies, and the ability to integrate to the wearable healthcare system are discussed. Finally, the future directions for further study are suggested.

20.
Adv Prev Med ; 2019: 8392348, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31093375

RESUMEN

BACKGROUND AND OBJECTIVE: Current cardiovascular disease (CVD) risk models are typically based on traditional laboratory-based predictors. The objective of this research was to identify key risk factors that affect the CVD risk prediction and to develop a 10-year CVD risk prediction model using the identified risk factors. METHODS: A Cox proportional hazard regression method was applied to generate the proposed risk model. We used the dataset from Framingham Original Cohort of 5079 men and women aged 30-62 years, who had no overt symptoms of CVD at the baseline; among the selected cohort 3189 had a CVD event. RESULTS: A 10-year CVD risk model based on multiple risk factors (such as age, sex, body mass index (BMI), hypertension, systolic blood pressure (SBP), cigarettes per day, pulse rate, and diabetes) was developed in which heart rate was identified as one of the novel risk factors. The proposed model achieved a good discrimination and calibration ability with C-index (receiver operating characteristic (ROC)) being 0.71 in the validation dataset. We validated the model via statistical and empirical validation. CONCLUSION: The proposed CVD risk prediction model is based on standard risk factors, which could help reduce the cost and time required for conducting the clinical/laboratory tests. Healthcare providers, clinicians, and patients can use this tool to see the 10-year risk of CVD for an individual. Heart rate was incorporated as a novel predictor, which extends the predictive ability of the past existing risk equations.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA