Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 171-177, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37615699

RESUMEN

PURPOSE: Currently, there are no specific data on the circadian course of intraocular pressure (IOP) in children, especially for IOP measurements in the supine position. The study aimed to characterize the diurnal and nocturnal IOP fluctuations in supine and sitting positions in patients less than 18 years of age. METHODS: Seventy-nine eyes of 79 patients under 18 years of age with suspicious optic nerve heads or ocular hypertension could be included in this study. All included patients showed an inconspicuous retinal nerve fiber layer thickness and Bruch's membrane minimum rim width by coherence tomography. IOP measurements during the 24-h IOP profile were retrospectively evaluated. Measurements were taken at 10:00, 16:00, 20:00, and 23:00 h in the sitting position and at 6:00 h in the morning in the supine position using iCare rebound tonometry on 2 consecutive days. RESULTS: Thirty-four of 79 children (43.0%) had peak nocturnal IOP values > 25 mmHg. The mean daily IOP was 18.8 ± 5.6 mmHg, and the mean daily fluctuation was 6.1 ± 4.0 mmHg. At 6 am, supine measurements were elevated to 25.1 ± 8.0 mmHg. Extensive fluctuations with values > 40 mmHg in the nocturnal supine measurement occurred in a relevant share of patients (n = 5). CONCLUSION: There appear to be relevant diurnal and nocturnal IOP fluctuations in healthy children (< 18 years). Nocturnal IOP measurements in supine patients with risk factors for glaucoma may provide important additional information to identify critical patients for further follow-up.


Asunto(s)
Glaucoma , Presión Intraocular , Niño , Humanos , Adolescente , Estudios Retrospectivos , Glaucoma/diagnóstico , Tonometría Ocular , Postura , Ritmo Circadiano/fisiología
2.
Retina ; 44(5): 764-773, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38181515

RESUMEN

PURPOSE: Exploratory analysis associated with the prospective, multicenter, randomized PRIVENT trial. To characterize the associations between laser flare photometry and anatomical and epidemiological features of rhegmatogenous retinal detachment (RRD). METHODS: The authors measured laser flare values of all 3,048 prescreened patients excluding those with comorbidities. A mixed regression analysis evaluated the strength of the influencing factors like age, sex, lens status, and presence and extent of RRD on laser flare. RESULTS: Rhegmatogenous retinal detachment was more frequent in men (65.8%) than in women (34.2%, P < 0.001) and in right (52%) than in left eyes (48%, P = 0.045). Phakic RRD affected less quadrants and was less likely to be associated with macula-off status than pseudophakic RRD (48.4% vs. 58.0% macula off, 23% vs. 31% ≥3 quadrants, P < 0.001). Laser flare of affected eyes was significantly higher compared with fellow eyes (12.6 ± 15.2 vs. 8.3 ± 7.4 pc/ms, P < 0.001). The factors age, sex, lens status, presence of RRD, and the number of quadrants affected were independent influencing factors on laser flare. R 2 was 0.145 for phakic and 0.094 for pseudophakic eyes. CONCLUSION: The results indicate that there may be more factors affecting laser flare than previously assumed. This might limit flare as predictive value for PVR and retinal redetachment.


Asunto(s)
Fotometría , Desprendimiento de Retina , Humanos , Desprendimiento de Retina/diagnóstico , Masculino , Femenino , Estudios Prospectivos , Fotometría/métodos , Persona de Mediana Edad , Anciano , Agudeza Visual/fisiología , Adulto , Rayos Láser
3.
Int Ophthalmol ; 44(1): 150, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38503938

RESUMEN

PURPOSE: To assess and compare the risk for development of cystoid macula edema (CME) after glaucoma drainage device (GDD) implantation versus conventional trabeculectomy with mitomycin (trab) for glaucoma. METHODS: Retrospective review of consecutive patients receiving trab or GDD implantation between 2016 and 2018. Inclusion criteria were availability of pre- and postoperative spectral domain optical coherence tomography (SD-OCT) of the macula. SD-OCT images were evaluated for presence of CME qualitatively, central subfield thickness (CST) and macular volume (MV). RESULTS: 73 eyes could be included, 42 received trab and 31 GDD surgery. Eyes receiving trab on average had 0.8 ± 0.8 previous intraocular operations, while eyes with GDD implantation had 3.1 ± 1.9 (p < 0.001). Occurrence of postoperative CME was significantly more frequent after GDD implantation (6 out of 31 (19.4%)) than after trab (2 out of 42 eyes = 4.8%), (p = 0.049). Mean preoperative CST as well as MV was comparable in both groups (CST before trab: 282.7 ± 23.0 µm, CST before GDD 284.2 ± 27.3 µm, p = 0.287; MV before trab: 7.8 ± 1.1 mm3, MV before GDD: 8.0 ± 0.8mm3, p = 0.305). Mean postoperative CST and MV were significantly higher after GDD (CST 338.5 ± 129.3 µm, MV 8.8 ± 2.6 mm3) than after trabeculectomy (CST 290.6 ± 60.2 µm, p = 0.038; MV 7.8 ± 1.2mm3, p = 0.039). CONCLUSIONS: In real-life conditions, GDD surgery seems to be associated with a higher risk to develop CME when compared to conventional trabeculectomy. This information may be helpful for glaucoma surgeons to advise the patients on postoperative risks of surgery.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Edema Macular , Trabeculectomía , Humanos , Trabeculectomía/efectos adversos , Trabeculectomía/métodos , Presión Intraocular , Glaucoma/cirugía , Implantes de Drenaje de Glaucoma/efectos adversos , Edema Macular/diagnóstico , Edema Macular/etiología , Edema Macular/cirugía , Edema , Estudios Retrospectivos
4.
Int Ophthalmol ; 44(1): 182, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38625418

RESUMEN

BACKGROUND/AIMS: This work aimed to investigate changes in optic nerve head (ONH) morphometry based on Bruch membrane opening in children with extensive nocturnal intraocular pressure (IOP) elevations. METHODS: The course of Bruch membrane opening-based optic nerve head (ONH) morphometry was analysed in thirty-two patients younger than 18 years with evaluable SD-OCT examinations of the ONH and nocturnal posture-dependent IOP elevation above 25 mmHg. Longitudinal changes in neuroretinal rim tissue, as measured by Bruch Membrane opening minimum rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (RNFL) thickness, were assessed. RESULTS: One year after the 24 h IOP measurement, global BMO-MRW (- 1.61 ± 16.8 µm, n.s.; p = 0.611) and RNFL (+ 0.64 ± 3.17 µm; n.s.; p = 0.292) measurements were not significantly different from the baseline. No significant BMO-MRW reduction (- 3.91 ± 24.3 µm; n.s. p = 0.458) or deviation in RNFL thickness (+ 1.10 ± 3.52 µm) was observed at the four-year follow-up. Absolute IOP values measured in the supine position did not correlate with changes in global BMO-MRW or RNFL thickness. CONCLUSION: Posture-dependent IOP elevations do not seem to influence retinal nerve fibre layer thickness or Bruch membrane opening-based morphometric data in childhood.


Asunto(s)
Oftalmopatías , Disco Óptico , Niño , Humanos , Presión Intraocular , Tonometría Ocular , Retina , Postura
5.
Surg Endosc ; 36(6): 4376-4385, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34750707

RESUMEN

BACKGROUND: The use of 3D technique compared to high-resolution 2D-4K-display technique has been shown to optimize spatial orientation and surgical performance in laparoscopic surgery. Since women make up an increasing amount of medical students and surgeons, this study was designed to investigate whether one gender has a greater benefit from using a 3D compared to a 4K-display system. METHODS: In a randomized cross-over trial, the surgical performance of male and female medical students (MS), non-board certified surgeons (NBCS), and board certified surgeons (BCS) was compared using 3D- vs. 4K-display technique at a minimally invasive training parkour with multiple surgical tasks and repetitions. RESULTS: 128 participants (56 women, 72 men) were included. Overall parkour time in seconds was 3D vs. 4K for all women 770.7 ± 31.9 vs. 1068.1 ± 50.0 (p < 0.001) and all men 664.5 ± 19.9 vs. 889.7 ± 31.2 (p < 0.001). Regarding overall mistakes, participants tend to commit less mistakes while using the 3D-vision system, showing 10.2 ± 1.1 vs. 13.3 ± 1.3 (p = 0.005) for all women and 9.6 ± 0.7 vs. 12.2 ± 1.0 (p = 0.001) for all men. The benefit of using a 3D system, measured by the difference in seconds, was for women 297.3 ± 41.8 (27.84%) vs. 225.2 ± 23.3 (25.31%) for men (p = 0.005). This can be confirmed in the MS group with 327.6 ± 65.5 (35.82%) vs. 249.8 ± 33.7 (32.12%), p = 0.041 and in the NBCS group 359 ± 52.4 (28.25%) vs. 198.2 ± 54.2 (18.62%), p = 0.003. There was no significant difference in the BCS group. CONCLUSION: 3D laparoscopic display technique optimizes surgical performance compared to the 2D-4K technique for both women and men. The greatest 3D benefit was found for women with less surgical experience. As a possible result of surgical education, this gender specific difference disappears with higher grade of experience. Using a 3D-vision system could facilitate surgical apprenticeship, especially for women.


Asunto(s)
Laparoscopía , Estudiantes de Medicina , Competencia Clínica , Estudios Cruzados , Femenino , Humanos , Imagenología Tridimensional , Laparoscopía/métodos , Masculino
6.
Graefes Arch Clin Exp Ophthalmol ; 260(10): 3321-3329, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35394209

RESUMEN

PURPOSE: To evaluate the dynamics of Bruch's membrane opening-based morphometrics of the optic nerve head (ONH) using spectral-domain optical coherence tomography (SD-OCT) during the first week after glaucoma surgery by trabeculectomy with mitomycin C. METHODS: Prospective, longitudinal analysis of 25 eyes of 25 patients treated by trabeculectomy. Twenty-four eyes had evaluable postoperative SD-OCT examinations. Bruch's membrane opening minimum rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (RNFL) thickness were analyzed at baseline before surgery, 1 day, 2 to 3 days, and 1 week after surgery. Changes compared to baseline were correlated to intraocular pressure (IOP). RESULTS: One day after surgery, the mean BMO-MRW changed by + 26.17 µm, p = 0.001 (mean IOP reduction by 17.01 mmHg). This increase persisted on day 2-3 with a mean increase of BMO-MRW of + 25.33 µm, p = 0.001 (mean IOP reduction by 20.46 mmHg) and by week 1 with a mean BMO-MRW increase of + 33.17 µm, p < 0.001 (mean IOP reduction by 22.55 mmHg). The increase in BMO-MRW correlated significantly with the reduction of IOP on day 1 (Spearman's rho ρ = 0.656, p = 0.003) and d2-3 (Spearman's rho ρ = 0.479, p = 0.038). There was no statistically significant correlation found between the IOP and the increase in BMO-MRW in week 1. RNFL thickness showed no significant changes at day 1 as well as days 2-3 (p ≥ 0.078, respectively). It showed a small but significant increase in week 1 by 3.94 µm, p = 0.015. CONCLUSIONS: Structural reversal of disc cupping in BMO-MRW occurs as early as 1 day after trabeculectomy and correlates to the extent of the IOP reduction. During the whole first week after surgery, a strong increase in BMO-MRW can be noted. The changes in BMO-based parameters need to be considered when evaluating patients' longitudinal follow-up.


Asunto(s)
Lámina Basal de la Coroides , Trabeculectomía , Humanos , Presión Intraocular , Mitomicina , Fibras Nerviosas , Estudios Prospectivos , Células Ganglionares de la Retina , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Campos Visuales
7.
Langenbecks Arch Surg ; 407(7): 3069-3078, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35869334

RESUMEN

PURPOSE: This study is a secondary analysis of the IDOSP trial published in the Annals of Surgery 2020. The aim of this study was to examine the influence of stereo acuity on surgical performance in a laparoscopic training parkour with 3D- versus 4 K-2D-display technique. METHODS: The surgical performance of medical students (MS), non-board-certified surgeons (NBC), and board-certified surgeons (BC) was compared using 3D- versus 4 K-2D-display technique at a training parkour in a randomized cross-over trial. Stereo acuity was tested by TNO and Titmus Stereo tests. RESULTS: Eighty-nine participants were included in this sub-trial. The median stereo acuity for all participants, measured with the Titmus test, was 25 s arc, with TNO test 30 s arc. Higher quality stereo vision, measured with the Titmus test, correlated significantly with a reduced parkour time (r = 0.26, p = 0.02) and error (r = 0.21, p = 0.048) with the 3D screen. The TNO test did not correlate significantly with parkour performance. There was no statistically significant correlation between parkour time nor error and stereo acuity using the 4 K system (p > 0.457 respectively). Higher age showed a significant correlation with lower stereo acuity measured with TNO (r = 0.21, p = 0.014), but not with the Titmus test (r = - 0.7, p = 0.39). Seven percent of the group "NBC and BC" showed reduced stereo acuity > 120 s arc with the Titmus test and 3% with the TNO test. CONCLUSION: High-quality stereo vision is of utmost importance for surgical skills using a 3D-display system. This was most obvious for MS and for tasks that place particularly high demands on hand-eye coordination. The Titmus test was more precise than the TNO test to predict the benefit of a 3D monitor system. Experience and fine motor skills could partly compensate for a poorer stereo acuity. TRIAL REGISTRATION: This trial was registered at clinicaltrials.gov (trial number: NCT03445429, registered February 26, 2018).


Asunto(s)
Percepción de Profundidad , Procedimientos Quirúrgicos Mínimamente Invasivos , Cirujanos , Análisis y Desempeño de Tareas , Humanos , Estudios Cruzados , Percepción de Profundidad/fisiología , Agudeza Visual/fisiología
8.
Ophthalmologica ; 245(3): 258-264, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34034256

RESUMEN

PURPOSE: The aim of this study was to investigate the influence of dietary supplementation using Age-Related Eye Disease Study 2 (AREDS2) on complement activation in patients with neovascular age-related macular degeneration (nAMD) under ongoing treatment. METHODS: In this prospective, single-center, controlled, open-label investigator-initiated trial, eligible nAMD patients were randomized at a ratio of 1:1 in 2 groups: those with and without dietary AREDS2 supplementation for 4 weeks. Zinc, plasma, and aqueous humor (AH) complement levels were quantified via enzyme-linked immunosorbent assays. RESULTS: Fifty of 62 enrolled patients completed the trial (AREDS2 n = 27, controls n = 23). Systemic zinc and complement levels were not different at baseline between the 2 groups (p > 0.1). At the final visit, systemic zinc levels were significantly higher in the AREDS2 group (10.16 ± 2.08 µmol/L; 8.66 ± 1.17 µmol/L; p = 0.007), whereas systemic and AH complement levels were not different (p > 0.1). In both groups, no significant change was observed in systemic levels of C3, C3a, FH, FI, and sC5b-9 (p > 0.1). Only systemic complement component Ba showed an increase from baseline to the end visit (p = 0.01). This increase was higher in the control group (p = 0.02) than in the AREDS2 group (p = 0.23). CONCLUSIONS: Short-term dietary AREDS2 supplementation leads to a significant increase in systemic zinc levels without any influence on complement activation levels.


Asunto(s)
Degeneración Macular , Degeneración Macular Húmeda , Activación de Complemento/fisiología , Suplementos Dietéticos , Humanos , Degeneración Macular/diagnóstico , Degeneración Macular/tratamiento farmacológico , Estudios Prospectivos , Degeneración Macular Húmeda/diagnóstico , Degeneración Macular Húmeda/tratamiento farmacológico , Zinc
9.
Int Ophthalmol ; 42(7): 2195-2204, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35038124

RESUMEN

PURPOSE: To evaluate the effect of Prism adaptation test (PAT) on the angle of squint in decompensated esophoria (decEPH) and decompensated microesotropia (decMET). METHODS: In this single-center retrospective study we reviewed the medical records of patients with the diagnosis of decEPH or decMET, aged at least 12 years, who were treated by strabismus surgery for the first time. The maximum Angle of squint (AOS) for far (F) and near (N) fixation and PAT results before surgery, as well as AOS (F) and AOS (N) after surgery and results of binocular function tests were considered. PAT included wearing a prism based on the largest angle for over 60 min. RESULTS: 100 patients (mean age 37 ± 17 years) were included in the decEPH group, 82 patients (mean age 30 ± 13 years) in the decMET group. For decEPH, before surgery AOS was 25.5 ± 8.8 pdpt (F) and 23.5 ± 9.8 pdpt (N). During PAT the AOS increased significantly by 2.7 ± 4.3 to 28.2 ± 8.6 pdpt (F) and by 4.9 ± 4.5 to 28.3 ± 9.5 pdpt (N). Altogether, in 82% of decEPH patients AOS (F) and/ or AOS (N) in- or decreased by at least 3 pdpt. For decMET, before surgery AOS was 28.6 ± 10.8 pdpt for far (F) and 30.9 ± 11.8 pdpt for near fixation (N). During PAT the AOS increased significantly by 4.2 ± 5.8 to 32.5 ± 9.5 pdpt (F) and by 3.7 ± 6.1 to 34.4 ± 9.5 pdpt (N). Altogether, in 51% of decMET patients, AOS (F) and/ or AOS (N) increased by at least 10 pdpt, therefore more than 5° which would have been maximally expected from mictrotropia, or decreased by at least 3 pdpt. CONCLUSIONS: The Prism adaptation test (PAT) showed remarkable changes in AOS in both decEPH and decMET. In patients with decEPH, the preoperative assessment of the "true AOS" under PAT reflects a pivotal requirement for successful strabismus surgery, as 82% had dose relevant angle changes ≥ 3 pdpt. For patients with decMET the preoperative prism adaptation test is especially of diagnostic value, but also 51% of decMET patients had changes in AOS beyond the expected microtropic angle (≥ 10 pdpt) or even a dose relevant angle decrease (≥ 3pdpt).


Asunto(s)
Esotropía , Estrabismo , Adaptación Ocular , Adolescente , Adulto , Humanos , Persona de Mediana Edad , Músculos Oculomotores/cirugía , Estudios Retrospectivos , Estrabismo/diagnóstico , Estrabismo/cirugía , Adulto Joven
10.
Ann Surg ; 272(5): 709-714, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32833763

RESUMEN

OBJECTIVE: To evaluate if "state-of-the-art" 3D- versus 4K-display techniques could influence surgical performance. BACKGROUND: High quality minimally invasive surgery is challenging. Therefore excellent vision is crucial. 3D display technique (3D) and 2D-4K technique (4K) are designed to facilitate surgical performance, either due to spatial resolution (3D) or due to very high resolution (4K). METHODS: In randomized cross-over trial the surgical performance of medical students (MS), non-board certified surgeons (NBC), and board certified surgeons (BC) was compared using 3D versus 4K display technique at a minimally invasive training Parkour. RESULTS: One hundred twenty-eight participants were included (February 2018 through October 2019, 49 MS, 39 NBC, 40 BC). The overall Parkour time (s) 3D versus 4K was 712.5 s ± 17.5 s versus 999.5 s ±â€Š25.1 s (P < 0.001) for all levels of experience. It was (3D vs 4K) for MS (30 tasks) 555.4 s ±â€Š28.9 s versus 858.7 s ±â€Š41.6 s, (P < 0.0001), for NBC (42 tasks) 935.9 s ±â€Š31.5 s versus 1274.1 s ±â€Š45.1 s (P =< 0.001) and for BC (42 task) 646.3 s ±â€Š30.9 s versus 865.7 s ±â€Š43.7 s (P < 0.001). The overall number of mistakes was (3D vs 4K) 10.0 ±â€Š0.5 versus 13.3 ±â€Š0.7 (P < 0.001), for MS 8.9 ±â€Š0.9 versus 13.1 ±â€Š1.1 (P < 0.001), for NBC 12.45 ±â€Š1.0 versus 16.7 ±â€Š1.2 (P < 0.001) and for BC 8.8 ±â€Š1.0 versus 10.0 ±â€Š1.2 (P = 0.18). MS, BC, and NBC showed shorter performance time in 100% of the task with 3D (significantly in 6/7 tasks). For number of mistakes the effect was less pronounced for more experienced surgeons. The National Aeronautics and Space Administration-task load index was lower with 3D. CONCLUSION: 3D laparoscopic display technique optimizes surgical performance compared to the 4K technique. Surgeons benefit from the improved visualization regardless of their individual surgical expertise.


Asunto(s)
Competencia Clínica , Procedimientos Quirúrgicos Mínimamente Invasivos/educación , Entrenamiento Simulado/métodos , Cirugía Asistida por Video/instrumentación , Adulto , Estudios Cruzados , Femenino , Humanos , Imagenología Tridimensional , Masculino , Desempeño Psicomotor , Método Simple Ciego
11.
Graefes Arch Clin Exp Ophthalmol ; 258(6): 1227-1236, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32140925

RESUMEN

PURPOSE: Structural reversal of disc cupping is a known phenomenon after trabeculectomy. The aim of this retrospective, longitudinal, cross-sectional analysis was to evaluate the postoperative dynamics of Bruch's membrane opening-based morphometrics of the optic nerve head following glaucoma drainage device surgery. METHODS: Forty-three eyes, treated by glaucoma drainage device surgery, were included in the study. Individual changes in the spectral domain optic coherence tomography (SD-OCT) parameters Bruch's membrane opening minimum rim width (BMO-MRW), Bruch's membrane opening minimum rim area (BMO-MRA) and peripapillary retinal nerve fiber layer (RNFL) thickness as well as mean defect in 30-2 perimetry were analyzed. Changes were correlated to postoperative intraocular pressure levels over time. Available follow-up visits were aggregated and grouped into a short-term follow-up (20 to 180 days after surgery), a midterm follow-up (181 to 360 days after surgery) and a long-term follow-up (more than 360 days after surgery). RESULTS: In short-term follow-up, BMO-MRW and BMO-MRA increased significantly (p <= 0.034). This increase correlated negatively with the intraocular pressure at the time of the follow-up (Pearson's rho = - 0.49; p = 0.039). From 6 months after surgery on, there was no statistically significant change in BMO-MRW and BMO-MRA (p >= 0.207). RNFL thickness and mean defect of 30-2 perimetry showed no significant changes after GDD implantation (p >= 0.189). CONCLUSIONS: Lowering of intraocular pressure by glaucoma drainage device surgery leads to an increase of Bruch's membrane opening based parameters in the first 6 months after surgery. These changes have to be taken into account when evaluating patients' longitudinal follow-up after glaucoma drainage device implantation.


Asunto(s)
Lámina Basal de la Coroides/patología , Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto/cirugía , Disco Óptico/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Estudios Transversales , Femenino , Estudios de Seguimiento , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Implantación de Prótesis , Curva ROC , Células Ganglionares de la Retina/patología , Estudios Retrospectivos , Tomografía de Coherencia Óptica , Tonometría Ocular , Agudeza Visual/fisiología , Pruebas del Campo Visual , Campos Visuales/fisiología
12.
Graefes Arch Clin Exp Ophthalmol ; 257(2): 339-347, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30483950

RESUMEN

PURPOSE: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and circumpapillary retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography (SD-OCT) after glaucoma surgery via ab-interno trabeculectomy in adult glaucoma patients. METHODS: Retrospective audit of 65 eyes of 65 participants undergoing ab-interno trabeculectomy using electroablation of the trabecular meshwork. In 53 eyes, surgery was combined with phacoemulsification and posterior chamber lens implantation. Pre- and postoperative SD-OCT examinations of the optic nerve head (ONH), intraocular pressure (IOP), and visual field data were analyzed. Longitudinal change in morphometric SD-OCT parameters of the ONH was compared and correlated to change in IOP and visual field function. RESULTS: BMO-MRW increased significantly between baseline (BL) and follow-up (FU) within the first 6 months after surgery (BL = 167.85 ± 90 µm; FU = 175.59 ± 89 µm; p = 0.034). This increase correlated with postoperative lowering of IOP (rho = - 0.41; p = 0.016). Nine months after surgery (range, 7-12 months), there was no significant change in BMO-MRW (BL = 196.79 ± 79; FU = 196.47 ± 85 µm; p = 0.95), while in later follow-up, a decrease of BMO-MRW was found (BL = 175.18 ± 78; FU = 168.65 ± 72; p = 0.05). RNFL thickness was unchanged in early (p > 0.16) and significantly decreased in later follow-up (p = 0.009). Mean deviation (MD) of visual field function did not show a significant change before and after surgery. CONCLUSION: Electroablative ab-interno trabeculectomy leads to a significant transient mild increase in BMO-MRW. This increase was shown to correlate with IOP lowering. Significant loss of BMO-MRW in later follow-up may reflect insufficient IOP reduction by surgery. The parameters RNFL thickness and MD seem less impacted directly by surgery.


Asunto(s)
Lámina Basal de la Coroides/patología , Glaucoma/cirugía , Presión Intraocular/fisiología , Disco Óptico/patología , Tomografía de Coherencia Óptica/métodos , Trabeculectomía/métodos , Campos Visuales/fisiología , Técnicas de Ablación/métodos , Anciano , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Humanos , Masculino , Pronóstico , Estudios Retrospectivos
13.
Ophthalmologie ; 121(7): 529-539, 2024 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-38904722

RESUMEN

Due to the demographic changes, the number of older patients in ophthalmological practices and clinics, including those with diplopia, is increasing. Some of the patients report not only horizontally shifted double images but also or only vertically shifted double images. Vertical double vision often causes significant diagnostic problems for ophthalmologists. The underlying condition could urgently require further neurological, neuroradiological and/or internal medical diagnostics (e.g., skew deviation, 4th nerve palsy, myasthenia, Graves' orbitopathy, orbital floor fracture, orbital mass, 3rd nerve palsy) but the cause of diplopia could also be a condition in which overdiagnosis should be avoided (e.g., sagging eye syndrome, the prevalence of which significantly increases with increasing age; decompensated strabismus due to inferior oblique muscle overaction, myopia-associated vertical tropia). For some diseases early diagnosis is important for a better prognosis, e.g., tumor diagnosis, Graves' disease and stroke. This article presents an overview of the most common and most important differential diagnoses of vertical tropia in patients over 50 years of age.


Asunto(s)
Diplopía , Estrabismo , Humanos , Diagnóstico Diferencial , Estrabismo/diagnóstico , Anciano , Diplopía/diagnóstico , Diplopía/etiología , Persona de Mediana Edad , Anciano de 80 o más Años , Masculino , Femenino
14.
Eur J Ophthalmol ; : 11206721221137169, 2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36348627

RESUMEN

PURPOSE: Objective tyndallometry using laser flare photometry can be utilized e.g., in management of uveitis. Previous studies showed a significant difference in flare values between pseudophakic and phakic eyes. We investigate a potential association between the degree of lens opacification and flare value in a large cohort phakic eyes. METHODS: Retrospective, non-interventional single center study. Laser flare values of 460 healthy fellow eyes from two large cohorts (primary rhegmatogenous retinal detachment (RRD), macular holes (MH)) were correlated with lens status, degree of lens opacity, and age. RESULTS: Out of 460 patients (mean age 64.6 ± 11.2, 57% male) 30.4% were pseudophakic (70.2 ± 10.9) and 69.6% phakic, of which 47.8% showed a clear lens (57.3 ± 9.1), 43.2% an mild cataract (65.2 ± 9.0) and 9.0% a moderate cataract (73.5 ± 9.0).In pseudophakia, flare (8.14 ± 4.6 pc/ms) was significantly higher compared to phakia (6.4 ± 3.9 pc/ms; p < 0.001). In phakic eyes, flare values increased significantly with increasing lens opacity (clear lens 5.3 ± 2.8 pc/ms; mild cataract 7.0 ± 4.0 pc/ms; moderate cataract 9.5 ± 6.1 pc/ms; p < 0.001). In clear lenses and mild cataract, age correlated significantly with flare (two-sided, p < 0.001, clear lenses R = 0.3; mild cataract R = 0.4). In clear lenses, flare values increased with age by 0.09 per year, in mild cataract by 0.17 (regression coefficients). No significant correlation was found between age and flare value in moderate cataract and pseudophakic eyes. CONCLUSION: The level of objective tyndallometry seems to be dependent on lens status, degree of lens opacity and age. These factors should therefore be taken into account when interpreting laser flare values in the future.

15.
Ophthalmologe ; 119(5): 453-461, 2022 May.
Artículo en Alemán | MEDLINE | ID: mdl-35378598

RESUMEN

BACKGROUND: Due to the risk of amblyopia congenital and infantile corneal opacities have a narrow therapeutic window, frequently with a complex surgical treatment. OBJECTIVE: The present study gives an overview of the current treatment options for congenital and infantile corneal opacities. METHODS: The results of a literature search are presented and own clinical data and examples are shown. RESULTS: In children ophthalmologic operations are surgically more demanding and the prognosis is generally worse. Surgical options include phototherapeutic keratectomy, crosslinking, corneal sutures, sectoral iridectomy, block excision and lamellar, penetrating, and auto-keratoplasty. An equally important part of the treatment is conservative treatment, when necessary with bandage lenses, glasses, contact lenses and occlusion. DISCUSSION: Whenever possible treatment of congenital and infantile corneal opacities should be limited to the affected layers/areas. Nevertheless, children and parents have to be prepared for many examinations, sometimes with the patient under anesthesia and should be well-informed about the prognosis and the risks.


Asunto(s)
Distrofias Hereditarias de la Córnea , Opacidad de la Córnea , Queratectomía Fotorrefractiva , Niño , Córnea/cirugía , Opacidad de la Córnea/diagnóstico , Opacidad de la Córnea/cirugía , Anomalías del Ojo , Humanos , Queratoplastia Penetrante
16.
Int J Ophthalmol ; 14(8): 1192-1198, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34414083

RESUMEN

AIM: To analyze the therapeutic effect of combined ab-interno trabeculectomy and cataract surgery on intraocular pressure (IOP) levels in supine and sitting postures during a 24-hour IOP profile. METHODS: Twenty-six eyes of twenty-six patients receiving ab-interno trabeculectomy using electroablation of the trabecular meshwork combined with cataract surgery or stand-alone were included in this retrospective analysis. IOP change during 24-hour IOP profiles within two years postoperatively were analyzed for eyes receiving surgery ("study eyes") and compared to fellow eyes, which had not received surgery. Clinical data including mean sitting IOP (siIOP), mean supine IOP (suIOP) and the number of topical antiglaucomatous medications (TAM) were extracted from patients' files. RESULTS: Preoperatively, siIOP was 17.6±5.3 mm Hg in study and 17.1±4.7 mm Hg in fellow eyes (P=0.347). Patients were treated with an average of 2.8±1.0 TAM. Best corrected visual acuity (BCVA) was significantly worse in study eyes (P<0.001), visual field function was marginally not significantly different (P=0.057). After surgery 9.6±6.8mo, study eyes had a mean siIOP of 14.5±3.6 mm Hg (IOP reduction: -3.2 mm Hg, P=0.009), a mean suIOP of 18.0±3.5 mm Hg, and an average of 1.3±1.34 TAM (P<0.001), while in fellow eyes, mean siIOP was 16.2±3.4 mm Hg and mean suIOP was 20.5±5.1 mm Hg. Postoperatively, the relative IOP increase between sitting and supine postures was approximately 30% in both study and fellow eyes (P=0.99). CONCLUSION: IOP after ab-interno trabeculectomy shows a comparable relative reduction in both supine and sitting position. Classical trabeculectomy is known to lower suIOP overproportionally.

18.
Trials ; 20(1): 299, 2019 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-31138290

RESUMEN

BACKGROUND: Three-dimensional (3D) stereoscopic vision is crucial to perform any kind of manual task. The reduction from real life 3D to virtual two-dimensional (2D) sight is a major challenge in minimally invasive surgery (MIS). A 3D display technique has been shown to reduce operation time and mistakes and to improve the learning curve. Therefore, the use of a3D display technique seems to optimize surgical performance for novice and experienced surgeons. Inspired by consumer electronics, a 4K display technique was recently introduced to MIS. Due to its high resolution and zoom effect, surgeons should benefit from it. The aim of this study is to evaluate if "state-of-the-art" 3D- vs. 4K-display techniques could influence surgical performance. METHODS: A randomized, cross-over, single-institution, single-blinded trial is designed. It compares the primary outcome parameter "surgical performance", represented by "performance time "and "number of mistakes", using a passive polarizing 3D and a 4K display system (two arms) to perform different tasks in a minimally invasive/laparoscopic training parkour. Secondary outcome parameters are the mental stress load (National Aeronautics and Space Administration (NASA) Task Load Index) and the learning curve. Unexperienced novices (medical students), non-board-certified, and board-certified abdominal surgeons participate in the trial (i.e., level of experience, 3 strata). The parkour consists of seven tasks (for novices, five tasks), which will be repeated three times. The 1st run of the parkour will be performed with the randomized display system, the 2nd run with the other one. After each run, the mental stress load is measured. After completion of the parkour, all participants are evaluated by an ophthalmologist for visual acuity and stereoscopic vision with five tests. Assuming a correlation of 0.5 between measurements per subject, a sample size of 36 per stratum is required to detect a standardized effect of 0.5 (including an additional 5% for a non-parametric approach) with a power of 80% at a two-sided type I error of 5%. Thus, altogether 108 subjects need to be enrolled. DISCUSSION: Complex surgical procedures are performed in a minimally invasive/laparoscopic technique. This study should provide some evidence to decide which display technique a surgeon could choose to optimize his performance. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03445429 . Registered on 7 February 2018.


Asunto(s)
Percepción de Profundidad , Laparoscopía/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Entrenamiento Simulado , Estudios Cruzados , Humanos , Curva de Aprendizaje , Evaluación de Resultado en la Atención de Salud , Proyectos de Investigación
19.
Am J Ophthalmol ; 194: 143-152, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30053469

RESUMEN

OBJECTIVE: To assess the impact of trabeculectomy for glaucoma on morphometric neuroretinal parameters of the optic nerve head (ONH) using spectral-domain optical coherence tomography (SD-OCT). DESIGN: Retrospective, interventional case series. METHODS: Participants: Eighty-eight eyes of 88 patients who underwent trabeculectomy with mitomycin C in 2016. INTERVENTION: All patients underwent trabeculectomy in 1 eye (study eye) and had evaluable SD-OCT examinations of the ONH to measure neuroretinal tissue before and at least at 1 of the 3-, 6-, and 12-month follow-up time points after surgery. MAIN OUTCOME MEASURES: Longitudinal change in Bruch membrane opening minimum rim width (BMO-MRW), Bruch membrane opening minimum rim area (BMO-MRA), peripapillary retinal nerve fiber layer (RNFL) thickness, intraocular pressure (IOP), and mean deviation in perimetry. RESULTS: In study eyes, BMO-MRW significantly increased postsurgically comparing baseline and follow-up examinations at 3 months (P = .012), at 6 months (P = .007), and at 1 year (P = .010) after trabeculectomy. The increase in BMO-MRW 6 months after surgery correlated with IOP reduction (r = 0.48; P = .001). BMO-MRA showed an equal increase (P ≤ .034). RNFL thickness remained stable between baseline and follow-up at 3, 6, and 12 months and showed a moderate loss after 18 months (P = .021) of follow-up. CONCLUSIONS: Structural reversal of disc cupping after trabeculectomy markedly influences Bruch membrane opening-based parameters for up to more than 1 year. Improvement in morphometry seems to correlate with the reduction of IOP while visual field function appears not to be influenced. In longitudinal follow-up of glaucoma patients by SD-OCT, evaluation of BMO-based parameters necessitates to reflect bias caused by surgery.


Asunto(s)
Lámina Basal de la Coroides/patología , Glaucoma de Ángulo Abierto/cirugía , Fibras Nerviosas/patología , Disco Óptico/fisiopatología , Enfermedades del Nervio Óptico/fisiopatología , Células Ganglionares de la Retina/patología , Trabeculectomía , Adulto , Anciano , Anciano de 80 o más Años , Lámina Basal de la Coroides/diagnóstico por imagen , Estudios de Casos y Controles , Estudios Transversales , Femenino , Estudios de Seguimiento , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Disco Óptico/diagnóstico por imagen , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Pruebas del Campo Visual , Campos Visuales/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA