Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 252
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 381(21): 2032-2042, 2019 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-31556978

RESUMEN

BACKGROUND: Monotherapy with a P2Y12 inhibitor after a minimum period of dual antiplatelet therapy is an emerging approach to reduce the risk of bleeding after percutaneous coronary intervention (PCI). METHODS: In a double-blind trial, we examined the effect of ticagrelor alone as compared with ticagrelor plus aspirin with regard to clinically relevant bleeding among patients who were at high risk for bleeding or an ischemic event and had undergone PCI. After 3 months of treatment with ticagrelor plus aspirin, patients who had not had a major bleeding event or ischemic event continued to take ticagrelor and were randomly assigned to receive aspirin or placebo for 1 year. The primary end point was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 bleeding. We also evaluated the composite end point of death from any cause, nonfatal myocardial infarction, or nonfatal stroke, using a noninferiority hypothesis with an absolute margin of 1.6 percentage points. RESULTS: We enrolled 9006 patients, and 7119 underwent randomization after 3 months. Between randomization and 1 year, the incidence of the primary end point was 4.0% among patients randomly assigned to receive ticagrelor plus placebo and 7.1% among patients assigned to receive ticagrelor plus aspirin (hazard ratio, 0.56; 95% confidence interval [CI], 0.45 to 0.68; P<0.001). The difference in risk between the groups was similar for BARC type 3 or 5 bleeding (incidence, 1.0% among patients receiving ticagrelor plus placebo and 2.0% among patients receiving ticagrelor plus aspirin; hazard ratio, 0.49; 95% CI, 0.33 to 0.74). The incidence of death from any cause, nonfatal myocardial infarction, or nonfatal stroke was 3.9% in both groups (difference, -0.06 percentage points; 95% CI, -0.97 to 0.84; hazard ratio, 0.99; 95% CI, 0.78 to 1.25; P<0.001 for noninferiority). CONCLUSIONS: Among high-risk patients who underwent PCI and completed 3 months of dual antiplatelet therapy, ticagrelor monotherapy was associated with a lower incidence of clinically relevant bleeding than ticagrelor plus aspirin, with no higher risk of death, myocardial infarction, or stroke. (Funded by AstraZeneca; TWILIGHT ClinicalTrials.gov number, NCT02270242.).


Asunto(s)
Aspirina/uso terapéutico , Enfermedad Coronaria/terapia , Hemorragia/inducido químicamente , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ticagrelor/uso terapéutico , Anciano , Aspirina/efectos adversos , Enfermedad Coronaria/tratamiento farmacológico , Método Doble Ciego , Quimioterapia Combinada , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Mortalidad , Infarto del Miocardio/epidemiología , Inhibidores de Agregación Plaquetaria/efectos adversos , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Ticagrelor/efectos adversos
2.
Catheter Cardiovasc Interv ; 99(6): 1723-1732, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35318789

RESUMEN

BACKGROUND: Low operator and institutional volume are associated with poorer procedural and long-term clinical outcomes in the general population of patients treated with percutaneous coronary interventions (PCI). AIM: To assess the relationship between operator experience and procedural outcomes of patients treated with PCI and rotational atherectomy (RA). METHODS: Data for conducting the current analysis were obtained from the national registry of percutaneous coronary interventions (ORPKI) maintained in cooperation with the Association of Cardiovascular Interventions (AISN) of the Polish Cardiac Society. The study covers data from January 2014 to December 2020. RESULTS: During the investigated period, there were 162 active CathLabs, at which 747,033 PCI procedures were performed by 851 operators (377 RA operators [44.3%]). Of those, 5188 were PCI with RA procedures; average 30 ± 61 per site/7 years (Me: 3; Q1-Q3: 0-31); 6 ± 18 per operator/7 years (Me: 0; Q1-Q3: 0-3). Considering the number of RA procedures annually performed by individual operators during the analyzed 7 years, the first quartile totaled (Q1: < =2.57), the second (Q2: < =5.57), and the third (Q3: < =11.57), while the fourth quartile was (Q4: > 11.57). The maximum number of procedures was 39.86 annually per operator. We demonstrated, through a nonlinear relationship with annualized operator volume and risk-adjusted, that operators performing more PCI with RA per year (fourth quartile) have a lower number of the overall periprocedural complications (p = 0.019). CONCLUSIONS: High-volume RA operators are related to lower overall periprocedural complication occurrence in patients treated with RA in comparison to low-volume operators.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Aterectomía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/terapia , Mortalidad Hospitalaria , Hospitales de Alto Volumen , Hospitales de Bajo Volumen , Humanos , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , Resultado del Tratamiento
3.
Eur Heart J ; 42(45): 4624-4634, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34662382

RESUMEN

AIMS: Patients at high bleeding risk (HBR) represent a prevalent subgroup among those undergoing percutaneous coronary intervention (PCI). Early aspirin discontinuation after a short course of dual antiplatelet therapy (DAPT) has emerged as a bleeding avoidance strategy. The aim of this study was to assess the effects of ticagrelor monotherapy after 3-month DAPT in a contemporary HBR population. METHODS AND RESULTS: This prespecified analysis of the TWILIGHT trial evaluated the treatment effects of early aspirin withdrawal followed by ticagrelor monotherapy in HBR patients undergoing PCI with drug-eluting stents. After 3 months of ticagrelor plus aspirin, event-free patients were randomized to 12 months of aspirin or placebo in addition to ticagrelor. A total of 1064 (17.2%) met the Academic Research Consortium definition for HBR. Ticagrelor monotherapy reduced the incidence of the primary endpoint of Bleeding Academic Research Consortium (BARC) 2, 3, or 5 bleeding compared with ticagrelor plus aspirin in HBR (6.3% vs. 11.4%; hazard ratio (HR) 0.53, 95% confidence interval (CI) 0.35-0.82) and non-HBR patients (3.5% vs. 5.9%; HR 0.59, 95% CI 0.46-0.77) with similar relative (Pinteraction = 0.67) but a trend towards greater absolute risk reduction in the former [-5.1% vs. -2.3%; difference in absolute risk differences (ARDs) -2.8%, 95% CI -6.4% to 0.8%, P = 0.130]. A similar pattern was observed for more severe BARC 3 or 5 bleeding with a larger absolute risk reduction in HBR patients (-3.5% vs. -0.5%; difference in ARDs -3.0%, 95% CI -5.2% to -0.8%, P = 0.008). There was no significant difference in the key secondary endpoint of death, myocardial infarction, or stroke between treatment arms, irrespective of HBR status. CONCLUSIONS: Among HBR patients undergoing PCI who completed 3-month DAPT without experiencing major adverse events, aspirin discontinuation followed by ticagrelor monotherapy significantly reduced bleeding without increasing ischaemic events, compared with ticagrelor plus aspirin. The absolute risk reduction in major bleeding was larger in HBR than non-HBR patients.


Asunto(s)
Intervención Coronaria Percutánea , Quimioterapia Combinada , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Ticagrelor/efectos adversos , Resultado del Tratamiento
4.
Eur Heart J ; 42(45): 4683-4693, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34423374

RESUMEN

AIMS: The aim of this study was to assess the impact of chronic kidney disease (CKD) on the safety and efficacy of ticagrelor monotherapy among patients undergoing percutaneous coronary intervention (PCI). METHODS AND RESULTS: In this prespecified subanalysis of the TWILIGHT trial, we evaluated the treatment effects of ticagrelor with or without aspirin according to renal function. The trial enrolled patients undergoing drug-eluting stent implantation who fulfilled at least one clinical and one angiographic high-risk criterion. Chronic kidney disease, defined as an estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2, was a clinical study entry criterion. Following a 3-month period of ticagrelor plus aspirin, event-free patients were randomly assigned to aspirin or placebo on top of ticagrelor for an additional 12 months. Of the 6835 patients randomized and with available eGFR at baseline, 1111 (16.3%) had CKD. Ticagrelor plus placebo reduced the primary endpoint of Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 bleeding as compared with ticagrelor plus aspirin in both patients with [4.6% vs. 9.0%; hazard ratio (HR) 0.50, 95% confidence interval (CI) 0.31-0.80] and without (4.0% vs. 6.7%; HR 0.59, 95% CI 0.47-0.75; Pinteraction = 0.508) CKD, but the absolute risk reduction was greater in the former group. Rates of death, myocardial infarction, or stroke were not significantly different between the two randomized groups irrespective of the presence (7.9% vs. 5.7%; HR 1.40, 95% CI 0.88-2.22) or absence of (3.2% vs. 3.6%; HR 0.90, 95% CI 0.68-1.20; Pinteraction = 0.111) CKD. CONCLUSION: Among CKD patients undergoing PCI, ticagrelor monotherapy reduced the risk of bleeding without a significant increase in ischaemic events as compared with ticagrelor plus aspirin.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Insuficiencia Renal Crónica , Quimioterapia Combinada , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/tratamiento farmacológico , Ticagrelor/uso terapéutico , Resultado del Tratamiento
5.
Int J Mol Sci ; 23(15)2022 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-35955824

RESUMEN

Background: Severe outcomes of COVID-19 account for up to 15% of all cases. The study aims to check if any gene variants related to cardiovascular (CVD) and pulmonary diseases (PD) are correlated with a severe outcome of COVID-19 in a Polish cohort of COVID-19 patients. Methods: In this study, a subset of 747 samples from unrelated individuals collected across Poland in 2020 and 2021 was used and whole-genome sequencing was performed. Results: The GWAS analysis of SNPs and short indels located in genes related to CVD identified one variant significant in COVID-19 severe outcome in the HADHA gene, while for the PD gene panel, we found two significant variants in the DRC1 gene. In this study, both potentially protective and risk variants were identified, of which variants in the HADHA gene deserve the most attention. Conclusions: This is the first study reporting the association between the HADHA and DRC1 genetic variants and COVID-19 severe outcome based on the cohort WGS analysis. Although all the identified variants are localised in introns, they may be correlated and therefore inherited along with other risk variants, potentially causative to severe outcome of COVID-19 but not discovered yet.


Asunto(s)
COVID-19 , Enfermedades Cardiovasculares , COVID-19/genética , Enfermedades Cardiovasculares/genética , Estudio de Asociación del Genoma Completo , Humanos , Mutación INDEL , Pulmón , Polimorfismo de Nucleótido Simple
6.
Int J Mol Sci ; 23(9)2022 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-35562925

RESUMEN

Although Slavic populations account for over 4.5% of world inhabitants, no centralised, open-source reference database of genetic variation of any Slavic population exists to date. Such data are crucial for clinical genetics, biomedical research, as well as archeological and historical studies. The Polish population, which is homogenous and sedentary in its nature but influenced by many migrations of the past, is unique and could serve as a genetic reference for the Slavic nations. In this study, we analysed whole genomes of 1222 Poles to identify and genotype a wide spectrum of genomic variation, such as small and structural variants, runs of homozygosity, mitochondrial haplogroups, and de novo variants. Common variant analyses showed that the Polish cohort is highly homogenous and shares ancestry with other European populations. In rare variant analyses, we identified 32 autosomal-recessive genes with significantly different frequencies of pathogenic alleles in the Polish population as compared to the non-Finish Europeans, including C2, TGM5, NUP93, C19orf12, and PROP1. The allele frequencies for small and structural variants, calculated for 1076 unrelated individuals, are released publicly as The Thousand Polish Genomes database, and will contribute to the worldwide genomic resources available to researchers and clinicians.


Asunto(s)
Genética de Población , Genoma Humano , Alelos , Frecuencia de los Genes , Humanos , Proteínas Mitocondriales , Polonia
7.
Eur J Clin Invest ; 51(8): e13555, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33782985

RESUMEN

BACKGROUND: The wide variation in bifurcation anatomy has generated an ongoing search for stents explicitly designed for coronary bifurcations, and to date, results have been underachieved. METHODS: The POLBOS I and POLBOS II were international, multicentre, randomized, open-label, controlled trials. Patients were randomly assigned to BiOSS Expert (in POLBOS I, biodegradable polymer eluting paclitaxel)/BiOSS LIM (in POLBOS II, biodegradable polymer eluting sirolimus) stent implantation or regular drug-eluting stent (rDES) deployment. A provisional T-stenting strategy was the default treatment option. The primary endpoint of this pooled data study was the cumulative rate of major adverse cardiovascular events (MACE) consisting of cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR). Telephone follow-up was performed annually up to 72 months. (ClinicalTrials.gov Identifier: POLBOS I-NCT02192840, POLBOS II-NCT02198300). RESULTS: The total study population consisted of 445 patients, 222 patients in the BiOSS group and 223 patients in the rDES group. The follow-up rate was 93.7% in the BiOSS group and 91.9% in the rDES group. At 72 months, there was no significant difference between BiOSS and rDES groups regarding MACE (25.7% vs 25.1%, HR 1.06, 95% CI 0.73-1.52), cardiac death (3.1% vs 4.0%, HR 0.94, 95% CI 0.43-2.34), MI (3.6% vs 4.9%, HR 0.76, 95% CI 0.32-2.89), TLR (18.9% vs 16.1%, HR 1.17, 95% CI 0.75-1.83) and stent thrombosis rates (0.9% vs 0.5%, HR 1.21, 95CI 0.75-2.09). CONCLUSIONS: At the 6-year follow-up, clinically significant clinical events did not differ between BiOSS stents and rDES.


Asunto(s)
Implantes Absorbibles , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Anciano , Stents Liberadores de Fármacos/clasificación , Femenino , Cardiopatías , Insuficiencia Cardíaca/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Sirolimus/uso terapéutico
8.
Eur Heart J ; 41(37): 3533-3545, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33085967

RESUMEN

AIMS: The aim of this study was to determine the effect of ticagrelor monotherapy on clinically relevant bleeding and major ischaemic events in relation to clinical presentation with and without non-ST elevation acute coronary syndromes (NSTE-ACS) among patients undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DES). METHODS AND RESULTS: We conducted a pre-specified subgroup analysis of The Ticagrelor With Aspirin or Alone in High Risk Patients After Coronary Intervention (TWILIGHT) trial, which enrolled 9006 patients with high-risk features undergoing PCI with DES. After 3 months of dual antiplatelet therapy (DAPT) with ticagrelor plus aspirin, 7119 adherent and event-free patients were randomized in a double-blind manner to ticagrelor plus placebo versus ticagrelor plus aspirin for 12 months. The primary outcome was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 bleeding while the composite of all-cause death, myocardial infarction (MI), or stroke was the key secondary outcome. Among patients with NSTE-ACS (n = 4614), ticagrelor monotherapy reduced BARC 2, 3, or 5 bleeding by 53% [3.6% vs. 7.6%; hazard ratio (HR) 0.47; 95% confidence interval (CI) 0.36-0.61; P < 0.001) and in stable patients (n = 2503) by 24% (4.8% vs. 6.2%; HR 0.76; 95% CI 0.54-1.06; P = 0.11; nominal Pint = 0.03). Rates of all-cause death, MI, or stroke among those with (4.3% vs. 4.4%; HR 0.97; 95% CI 0.74-1.28; P = 0.84) and without (3.1% vs. 3.2%; HR 0.96; 95% CI 0.61-1.49; P = 0.85) NSTE-ACS were similar between treatment arms irrespective of clinical presentation (Pint = 0.96). CONCLUSION: Among patients with or without NSTE-ACS who have completed an initial 3-month course of DAPT following PCI with DES, ticagrelor monotherapy reduced clinically meaningful bleeding events without increasing ischaemic risk as compared with ticagrelor plus aspirin. The benefits of ticagrelor monotherapy with respect to bleeding events were more pronounced in patients with NSTE-ACS. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT02270242.


Asunto(s)
Síndrome Coronario Agudo , Intervención Coronaria Percutánea , Síndrome Coronario Agudo/tratamiento farmacológico , Aspirina/uso terapéutico , Quimioterapia Combinada , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ticagrelor/uso terapéutico , Resultado del Tratamiento
9.
Wiad Lek ; 74(7): 1622-1627, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34459762

RESUMEN

OBJECTIVE: The aim: We aimed to assess the feasibility and safety of performing balloon aortic valvuloplasty (BAV) with Valver balloon catheter (Balton, Poland) in adults with severe aortic stenosis as a bridge or palliative treatment. PATIENTS AND METHODS: Materials and methods: We identified consecutive patients who underwent BAV procedures between May 2019 and March 2020 using Valver balloon catheters. Demographic data, medical history, and clinical characteristics were retrospectively collected in all study patients together with periprocedural data as well as 12-month follow-up data. RESULTS: Results: We included 18 patients. The mean population age was 78.1±8.9 years, and women were 61.1%. The most common co-morbidities were arterial hypertension (88.9%), dyslipidemia (83.3%), and coronary artery disease (72.2%). The baseline mean aortic valve pressure gradient was 49.94±27.02 mmHg and the mean aortic valve area (AVA) was 0.65±0.20 cm2. In all cases, the procedure was performed from the femoral access via the 8F sheath. Two Valver balloon catheter sizes were used 18x40mm (33.3%) and 20x40mm (66.7%). Three periprocedural complications were observed, and none was associated with the Valver balloon catheter per se. The transthoracic echocardiography after the procedure revealed a decrease in the mean pressure gradient of 11.1±8.85 mmHg, and an increase in AVA of 0.21±0.19 cm2. At 12-month follow-up, the mortality rate was 38.9%. CONCLUSION: Conclusions: BAV is a procedure increasingly performed in catheterization laboratories worldwide. This paper confirmed the relative safety of BAV with Valver balloon catheters in the modern era, showing a low incidence of valve and vascular complications.


Asunto(s)
Estenosis de la Válvula Aórtica , Cuidados Paliativos , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Femenino , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
10.
Lancet ; 393(10175): 987-997, 2019 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-30827782

RESUMEN

BACKGROUND: Supraflex is a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts. We aimed to compare Supraflex with the standard of care, Xience, an everolimus-eluting stent with a durable polymer coating, regarding clinical outcomes with a randomised trial in an all-comer population. METHODS: We did a prospective, randomised, single-blind, multicentre study (TALENT) across 23 centres in Europe (the Netherlands, Poland, the UK, Spain, Bulgaria, Hungary, and Italy). Eligible participants were aged 18 years or older, had one or more coronary artery stenosis of 50% or greater in a native coronary artery, saphenous venous graft, or arterial bypass conduit, and had a reference vessel diameter of 2·25-4·50 mm. Patients underwent percutaneous coronary intervention in an all-comer manner. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts (Supraflex) or an everolimus-eluting stent with a durable polymer coating (Xience). Randomisation was done by local investigators by use of a web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between groups at 12 months after the procedure, assessed in an intention-to-treat population. On assumption of 1-year composite endpoint prevalence of 8·3%, a margin of 4·0% was defined for non-inferiority of the Supraflex group compared with the Xience group. This trial is registered with ClinicalTrials.gov, number NCT02870140. FINDINGS: Between Oct 21, 2016, and July 3, 2017, 1435 patients with 1046 lesions were randomly assigned to Supraflex, of whom 720 received the index procedure, and 715 patients with 1030 lesions were assigned to Xience, all receiving the index procedure. At 12 months, the primary endpoint had occurred in 35 patients (4·9 %) in the Supraflex group and in 37 patients (5·3%) in the Xience group (absolute difference -0·3% [one-sided 95% upper confidence bound 1·6%], pnon-inferiority<0·0001). Definite or probable stent thrombosis prevalence, a safety indicator, was low in both groups and did not differ between them. INTERPRETATION: The Supraflex stent was non-inferior to the Xience stent for a device-oriented composite clinical endpoint at 12 months in an all-comer population. Supraflex seems a safe and effective alternative drug-eluting stent to other stents in clinical practice. FUNDING: European Cardiovascular Research Institute.


Asunto(s)
Aterosclerosis/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Inmunosupresores/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Stents Liberadores de Fármacos/efectos adversos , Determinación de Punto Final , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Método Simple Ciego , Trombosis/etiología
11.
Catheter Cardiovasc Interv ; 96(1): E84-E92, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32150341

RESUMEN

OBJECTIVES: To define the impact of side branch (SB) lesion length on clinical outcomes after percutaneous coronary intervention (PCI) on bifurcation lesions. BACKGROUND: The role of the SB lesion length remains questionable in PCI planning and its implication on clinical outcome is controversial. METHODS: Data from the retrospective multicenter EBC-P2BiTO registry were analyzed. The primary endpoint was the occurrence of major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction excluding periprocedural, or stent thrombosis at 13 months median follow-up (IQR 11-28). By using propensity scores for inverse probability of treatment weighting (IPTW), the comparison of treatment groups was adjusted to correct for potential confounding. RESULTS: Among 1,252 patients, SB was normal in 489 (39%), diseased in 763 (61%) cases. MACE occurred in 68 patients (5.4%). The optimal discriminant SB lesion length for MACE was ≥10 mm, with an area under the curve of 0.71 (p < .01). The incidence of MACE was higher among patients with SB lesions ≥10 mm (8%) than with normal SB (4.1%) (hazard ratio [HR], 2.8; 95% confidence interval [CI], 1.5-5.3; p = .001, IPTW-adjusted) or SB lesions <10 mm (5.1%) (HR, 1.5; 95% CI, 1.1-3.3; p = .048, IPTW-adjusted), being similar between these last two groups. CONCLUSIONS: In bifurcation PCI, SB lesion length ≥ 10 mm identifies patients at higher risk of MACE than those with <10 mm SB lesions and those without SB disease, considering that no differences were observed among these last two groups. Careful planning is mandatory when approaching bifurcations with long SB lesions.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Wiad Lek ; 73(7): 1580-1582, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32759458

RESUMEN

Penetrating aortic ulcer (PAU) is ulceration of an aortic atherosclerotic plaque penetrating through the internal lamina into the media. PAU is a rare condition and occurs in 2% - 7% of acute aortic syndromes (AAS); however, the actual incidence is unknown because of asymptomatic patients. One may treat it conservatively as well as surgically. We present a case of a 54-year-old man, who was admitted to hospital due to the exaggeration of exertional chest pain and persistent headaches. During coronary angiography, the suspicion of PAU was raised. Contrast-enhanced computed tomography confirmed the diagnosis. Transesophageal echocardiography showed bicuspid aortic valve with minimal calcification, the dilated ascending aorta, large atherosclerotic plaques in the aortic arch with ulceration (thickness: 5.0 - 5.5mm, diameter: 5 - 6 mm, depth: 3 - 4 mm), without intramural hematoma. Conservative treatment was chosen with uneventful 2-year follow-up. Although surgical management is advocated for patients with PAU type A, we demonstrated that type A PAU can be successfully treated conservatively as well.


Asunto(s)
Aorta Torácica , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas , Úlcera , Aorta , Enfermedad de la Válvula Aórtica Bicúspide , Tratamiento Conservador , Humanos , Masculino , Persona de Mediana Edad
13.
Am Heart J ; 214: 107-112, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31200280

RESUMEN

Critical limb ischemia is associated with excessively high risk for cardiovascular events, including myocardial infarction and death. Additionally, in this patient population non-invasive evaluation of coronary artery disease is limited due to (1) inability of exercise testing, (2) frequent occurrence of balanced ischemia and (3) frequent occurrence of diffuse coronary calcification. Intentional Coronary Revascularization Versus Conservative Therapy in Patients Undergoing Peripheral Artery Revascularization Due to Critical Limb Ischemia trial (INCORPORATE trial) is a multicentric international randomized open label clinical trial. Trial will recruit patients, who underwent successful peripheral artery revascularization due to critical limb ischemia and randomize 1:1 to conservative medical therapy versus an immediate invasive strategy to investigate and treat coronary artery disease. The objective is to evaluate whether intentional invasive strategy with ischemia targeted reasonably complete coronary revascularization is superior as compared to conventional primarily conservative approach in terms of spontaneous myocardial infarction and overall survival at 12 months follow-up. The trial is registered at clinicaltrials.gov (NCT03712644).


Asunto(s)
Tratamiento Conservador , Enfermedad de la Arteria Coronaria/terapia , Isquemia/complicaciones , Pierna/irrigación sanguínea , Intervención Coronaria Percutánea , Ensayos Clínicos Controlados Aleatorios como Asunto , Cateterismo Periférico , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/etiología , Diagnóstico Precoz , Reserva del Flujo Fraccional Miocárdico , Humanos , Isquemia/terapia , Estudios Multicéntricos como Asunto , Enfermedad Arterial Periférica/complicaciones
14.
Catheter Cardiovasc Interv ; 92(2): 302-309, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-29027737

RESUMEN

OBJECTIVES: The aim of the study was to capture the evolution of neointima after implantation of a biodegradable polymer-coated, sirolimus-eluting, cobalt-chromium coronary stent system (BP-DES). BACKGROUND: Optical coherence tomography (OCT) suggests that in-stent neointimal morphology influences clinical outcomes after DES implantation. METHODS: Sixty patients treated with single BP-DES implantation were examined by quantitative coronary angiography (QCA) and OCT at 3, 6, and 12-month follow-up. RESULTS: Median late lumen loss by QCA (mm) was 0.04 (IQR 0, 0.08), 0.17 (IQR 0, 0.32), and 0.14 (IQR 0.07, 0.31) at 3, 6, and 12-month follow-up respectively (P = 0.03). OCT cross-section multilevel analysis showed uncovered struts in 3.90%, 1.78%, and 0.02% of struts respectively (P = 0.03). The corresponding malapposition rates were 0.12%, 0.04%, and 0%. Lipid-rich neointima was observed only at 12-month follow-up in one restenotic lesion (0.77% cross-sections) that was accountable for the only target vessel revascularization. The homogeneous pattern was prevalent at all three time points, but its incidence displayed an upward trend (3 months: 59%; 6 months: 71%; 12 months: 88%) despite no difference in neointimal volume between 6 and 12 months. Conversely, a trend could be observed of decreasing incidence of heterogeneous pattern as the follow-up length increased. CONCLUSIONS: In this study of a single-type BP-DES, the majority of stent struts were covered within 3 months from implantation. While the quantitative neointimal accumulation plateaued at 6 months with no further significant increase beyond 6 months, the neointima continued to evolve qualitatively and mature along with better strut coverage between 6 and 12 months after implantation.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos , Neointima , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Tomografía de Coherencia Óptica , Anciano , Fármacos Cardiovasculares/efectos adversos , Aleaciones de Cromo , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Polonia , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
15.
J Interv Cardiol ; 31(5): 599-607, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29869380

RESUMEN

OBJECTIVES: We evaluated the impact of stent inflation pressure and type of guidewire on "jailed" coronary guidewire damage occurring during bifurcation angioplasty. BACKGROUND: Despite new techniques and treatment options during percutaneous coronary intervention (PCI) we still observe peri- and postoperative complications for to various known and unknown reasons. METHODS: Patients undergoing PCI within the coronary bifurcation were randomly assigned to one of four groups: Pilot 50 or BMW guidewire and pressure ≤12 or >12 atm. After PCI each "jailed" guidewire was evaluated under an optical microscope. The Wide Beast Scale (WBS) was developed for the internal purposes of the study and was used for qualitative assessment. Also, the inflation pressure, the patients' characteristics and the technical parameters of the procedure were recorded. RESULTS: The clinical characteristics were similar in all the groups. There was no statistical significance of the degree of damage, rated on the WBS, for either guidewire group with respect to inflation pressure (P = 0.49). The prevalence of guidewire damage was higher in the BMW versus the Pilot 50 group (98.4% vs 67.4% respectively, P = 0.00001) as was the severity of the damage (grades 3 and 4) in BMW versus Pilot 50 (55.6% vs 13.0% respectively, P = 0.00001). CONCLUSIONS: The inflation pressure during stent implantation had no impact on "jailed" guidewire damage. The difference in the prevalence of serious damage and total damage number was statistically significant for the BMW guidewire compared to the Pilot50. The BMW guidewire was an independent predictor of the degree of damage to the guidewire.


Asunto(s)
Implantación de Prótesis Vascular , Angiografía Coronaria , Vasos Coronarios/lesiones , Complicaciones Intraoperatorias , Stents/efectos adversos , Lesiones del Sistema Vascular , Anciano , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Análisis de Falla de Equipo , Femenino , Humanos , Incidencia , Complicaciones Intraoperatorias/epidemiología , Complicaciones Intraoperatorias/etiología , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Lesiones del Sistema Vascular/epidemiología , Lesiones del Sistema Vascular/etiología
16.
Eur J Clin Invest ; 47(7): 524-530, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28555728

RESUMEN

BACKGROUND: Mean platelet volume (MPV) was proved to be a reliable prognostic factor in cardiac patients. However, platelet distribution width (PDW) was disclosed to be more specific marker of platelet reactivity. The aim of study was to evaluate whether baseline PDW value can predict the outcome in patients undergoing percutaneous coronary interventions (PCI) with drug-eluting stent implantation within coronary bifurcation lesions. MATERIALS AND METHODS: It was a two-centre observational study, which included patients who underwent PCI within bifurcation lesions between January 2014 and December 2014. Thrombocytopenia below 100 000/µL and STEMI were the exclusion criteria. Analysed data came entirely from in-hospital records and information obtained from the 12-month telephone follow-up. RESULTS: We included 269 patients. Mean PDW value was 13·4 ± 2·5 fL, whereas median was 13 (Q1 < 11·6 fL, Q2 11·6-13 fL, Q3 13-14·8 fL and Q4 > 14·8 fL). We found strong correlation between PDW and MPV (r = 0·96, P < 0·001), but no correlation was revealed between red blood cell distribution width (RDW) and PDW (r = 0·003, P = 0·95) as well as RDW and MPV (r = 0·0018, P = 0·98). Receiver operating characteristics (ROC) curve showed that PDW for cutoff 15·8% can predict MACE rate with sensitivity of 79% and specificity of 47% (area under curve - AUC 0·654; P = 0·01). A ROC curve for PDW categorized by 1-year TLR rate was described by optimal cutoff 16·3%, with sensitivity 69% and specificity 54% (AUC 0·697; P = 0·0015). CONCLUSIONS: PDW is an affordable and reliable predictor of 1-year MACE and TLR rate after PCI within coronary bifurcation lesions.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Volúmen Plaquetario Medio , Anciano , Aspirina/uso terapéutico , Plaquetas/fisiología , Clopidogrel , Enfermedad de la Arteria Coronaria/mortalidad , Stents Liberadores de Fármacos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/mortalidad , Infarto del Miocardio sin Elevación del ST/mortalidad , Infarto del Miocardio sin Elevación del ST/cirugía , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Recurrencia , Ticlopidina/análogos & derivados , Ticlopidina/uso terapéutico , Resultado del Tratamiento
17.
Intervirology ; 59(3): 143-151, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28081531

RESUMEN

BACKGROUND: The meaning of viral nucleic acids in the myocardium in many cases is difficult for clinical interpretation, whereas the presence of viral nucleic acids in the serum is a marker of active infection. We determined the diagnostic value of viral nucleic acids in ventricular serum and peripheral serum samples in comparison with endomyocardial biopsy (EMB) specimens in patients with clinically suspected myocarditis. METHODS: The viral nucleic acid evaluation was performed in serum samples and EMB specimens by real-time PCR in 70 patients (age: 47 ± 16 years). The biopsy specimens were examined by histo- and immunohistochemistry to detect inflammatory response. RESULTS: The viral nucleic acids were detected in ventricular and peripheral serum, and EMB samples of 10 (14%), 14 (20%), and 32 (46%) patients, respectively. Notably, viral nucleic acids of the same virus as in the EMB sample were present more often in ventricular than in peripheral serum (60 vs. 7%, p = 0.01). A significant concurrence was observed between the positive and the negative results of viral nucleic acids present in EMB and ventricular serum (p = 0.0001). CONCLUSIONS: The detection of the same viral nucleic acid type in the myocardium and in ventricular serum being significantly more frequent than in the peripheral serum may suggest that the site of the blood collection is important for more precise and reliable confirmation of the active viral replication in the heart.


Asunto(s)
ADN Viral/sangre , Corazón/virología , Miocarditis/sangre , Miocarditis/virología , ARN Viral/sangre , Virosis/diagnóstico , Virosis/virología , Adulto , Biopsia , Recolección de Muestras de Sangre , Cardiomiopatía Dilatada/sangre , Cardiomiopatía Dilatada/virología , ADN Viral/análisis , Femenino , Humanos , Inmunohistoquímica , Masculino , Persona de Mediana Edad , Miocarditis/diagnóstico , Miocardio/patología , Miocardio/ultraestructura , ARN Viral/análisis , Reacción en Cadena en Tiempo Real de la Polimerasa , Replicación Viral , Adulto Joven
18.
J Interv Cardiol ; 28(1): 51-60, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25689548

RESUMEN

OBJECTIVES: The aim was to assess the effectiveness and safety profile of a new dedicated bifurcation stent - sirolimus-eluting BiOSS LIM® (Balton, Poland) in 12-month Registry. BACKGROUND: The optimal approach to coronary bifurcations treatment by percutaneous coronary intervention (PCI) has been still a subject of debate. Dedicated bifurcation stents are one of the proposed solutions. METHODS: This was the international, 3-center registry, which enrolled patients with non-ST-elevation acute coronary syndrome (NSTE-ACS) and stable angina. Provisional T-stenting was the obligatory strategy of the treatment. Angiographic control was planned at 12 months. The primary endpoint was cumulative rate of death, myocardial infarction (MI) and target lesion revascularization (TLR) at 12 months. RESULTS: A total of 60 patients with coronary bifurcations were enrolled (mean age 66.4 ± 11 years, 28.3% of female). There were 21.7% of patients with NSTE-ACS, 78.3% with hypertension, 38.3% with diabetes, 28.3% had previous MI, and 46.7% and 10% underwent prior revascularization, respectively, PCI and coronary artery bypass graft. The device success rate was 100%. Side branch was treated with an additional classical drug-eluting stent implantation in 23.3% of cases. At 12 months, the cumulative major adverse cardiovascular events rate was 11.7%. During follow-up (11 ± 1 months) there was 1 non-cardiac death (1.7%), 1 non-ST-elevated myocardial infarction (1.7%) due to restenosis and no case of stroke or in-stent thrombosis. Overall TLR was 8.3% (clinically driven TLR - 1.7%, angiographically driven - 6.6%). Mean late lumen loss was as follows: In main vessel - 0.35 ± 0.33 mm, in main branch - 0.34 ± 0.27 mm and in side branch - 0.18 ± 0.38 mm. CONCLUSION: Dedicated bifurcation stent BiOSS® LIM proved to be feasible device, with promising safety and long-term clinical effectiveness in the treatment of coronary bifurcation lesions, including distal left main stem stenosis.


Asunto(s)
Síndrome Coronario Agudo/terapia , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus , Anciano , Reestenosis Coronaria/epidemiología , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Sistema de Registros
19.
BMC Cardiovasc Disord ; 15: 150, 2015 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-26573577

RESUMEN

BACKGROUND: The aim of this study was to assess the safety and the efficacy of the novel sirolimus-eluting Prolim® stent with a biodegradable polymer in the all-comers population. METHODS: We prospectively enrolled all patients with stable coronary artery disease or acute coronary syndrome treated with Prolim® stent between January and December 2013 in two interventional cardiology centers in Poland. Angiographic control was planned at 12 months, in which 15 % of patients (randomly chosen) underwent optical coherence tomography imaging. The primary end-point was the cumulative rate of cardiac death, myocardial infarction, and target lesion revascularization at 12 months. RESULTS: There were 204 patients enrolled, in whom 238 Prolim® stents were deployed (1.17 stent per patient). The mean age was 68 ± 10 years and 32.8 % were females. The examined stent was implanted in 5.9 % in STEMI patients, in 21.6 % - in NSTE-ACS and in 72.5 % - in patients with stable coronary artery disease. The Prolim® stent was most frequently implanted in right coronary artery (38.2 %) followed by left anterior descending artery (34.0 %). The cumulative major adverse cardiovascular events rate at 12 months was 6.9 %, and the clinically-driven target lesion revascularization rate - 5.4 %. At 12 months in quantitative coronary angiography the late lumen loss was 0.21 ± 0.18 mm, and in optical coherence tomography the mean neointima burden was 24.6 ± 8.6 %. CONCLUSIONS: Sirolimus-eluting Prolim® stent with a biodegradable polymer is a feasible device with a very good safety profile and long-term clinical effectiveness. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT02545985 .


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/efectos de los fármacos , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Polímeros , Sirolimus/administración & dosificación , Tomografía de Coherencia Óptica , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/mortalidad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Neointima , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Polonia , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento
20.
J Interv Cardiol ; 27(3): 242-51, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24708143

RESUMEN

OBJECTIVES: The aim of this study was to assess prospectively the effectiveness and safety profile of distal left main stem (LMS) stenosis treatment with dedicated bifurcation paclitaxel-eluting stent BiOSS Expert®. BACKGROUND: Angioplasty of distal LMS stenosis is always a high-risk procedure, and optimal treatment is uncertain. METHODS: This was a prospective international 2-center study, which enrolled patients with non-ST-elevation acute coronary syndrome (NSTE-ACS) or stable angina with distal left main stenosis. All patients were treated with the dedicated bifurcation stent BiOSS Expert®. Provisional T-stenting was the obligatory strategy. Angiographic control was performed after 12 months. The primary end-point was cumulative rate of death, myocardial infarction (MI), and target lesion revascularization (TLR) at 12 months. Angiographic end-points included late lumen loss, percent diameter stenosis, and binary restenosis rate. RESULTS: A total of 54 patients with distal LMS stenosis were enrolled. Seven patients (13%) were enrolled during NSTE-ACS, 77.8% were hypertensive, 27.8% were diabetic, 51.9% had previous MI, 53.7% underwent prior percutaneous coronary intervention, and 16.7% coronary artery bypass graft. The mean SYNTAX score was 21.52 ± 6.50. The device success rate was 100%. The mean BiOSS Expert stent parameters were as follows: 4.07 ± 0.26 mm × 3.36 ± 0.26 mm × 16.61 ± 1.72 mm and in side branch the other stent (classical drug-eluting stent) was implanted in 25.9% of cases. The overall TLR was 9.3%. There were no death, stent thrombosis, or acute MI. In the univariate regression analysis, the only factor associated with higher risk for TLR was the SYNTAX score value. CONCLUSIONS: The dedicated bifurcation stent BiOSS Expert® proved to be a feasible device, with promising safety and long-term clinical effectiveness in the treatment of distal LMS stenosis.


Asunto(s)
Angina Estable , Angioplastia Coronaria con Balón , Estenosis Coronaria , Stents Liberadores de Fármacos , Paclitaxel/uso terapéutico , Anciano , Angina Estable/etiología , Angina Estable/terapia , Angioplastia , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/métodos , Antineoplásicos Fitogénicos/uso terapéutico , Angiografía Coronaria/métodos , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA