Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Magn Reson ; 20(1): 51, 2018 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-30078377

RESUMEN

BACKGROUND: Comparing cardiovascular magnetic resonance (CMR) angiography with computed tomography angiography (CTA), a major deficiency has been its inability to reliably image peripheral vascular calcifications that may impact the choice of interventional strategy and influence patient prognosis. Recently, MRI using a proton density-weighted, in-phase stack of stars (PDIP-SOS) technique has proved capable of detecting these calcifications. The goal of the present study was two-fold: (1) to determine whether magnetic field strength impacts the apparent size and conspicuity of ilio-femoral arterial calcifications; and (2) to determine whether the technique can be accurately applied to image aorto-iliac arterial calcifications. MAIN BODY: Two patient cohorts were studied. For the first cohort, ilio-femoral arterial calcifications were imaged at 1.5 Tesla in 20 patients and at 3 Tesla in 12 patients. For the second cohort, aorto-iliac arterial calcifications were imaged in 10 patients at 3 Tesla and one patient at 1.5 Tesla. Qualitative image analysis as well as quantitative analysis using a semi-automated technique were performed using CTA as the reference standard. Qualitatively, most PDIP-SOS CMR images showed good-to-excellent confidence to detect vascular calcifications, with good-to-excellent inter-reader agreement (κ = 0.67 for ilio-femoral region, P < 0.001; κ = 0.80 for aorto-iliac region, P < 0.01). There was an overall excellent correlation (r = 0.98, P < 0.001) and agreement (intraclass correlation coefficient = 0.97, P < 0.001) between PDIP-SOS CMR and CTA measures of calcification volume in both regions, with no overt difference in performance at 1.5 Tesla vs. 3 Tesla for ilio-femoral calcifications. CMR lesion volumes were slightly lower than those measured for CTA. CONCLUSION: Using PDIP-SOS CMR, aorto-iliac and ilio-femoral calcifications could be simultaneously evaluated at 3 Tesla in less than six minutes with excellent correlation and agreement to CTA. Our results suggest that PDIP-SOS CMR provides a reliable alternative to CT for pre-interventional evaluation of peripheral vascular calcium burden.


Asunto(s)
Aorta/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Aortografía/métodos , Arteria Femoral/diagnóstico por imagen , Arteria Ilíaca/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Enfermedad Arterial Periférica/diagnóstico por imagen , Calcificación Vascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada , Femenino , Humanos , Illinois , Campos Magnéticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados
2.
J Comput Assist Tomogr ; 42(5): 739-746, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29958198

RESUMEN

OBJECTIVE: The aim of this study was to determine whether it is feasible to visualize the coronary origins in patients with congenital heart disease (CHD) using single-shot coronary quiescent-interval slice-selective (QISS) magnetic resonance angiography (MRA) with compressed sensing (CS). METHODS: This retrospective study leveraged a parent study, which aimed to compare breath-hold, 2.1-fold accelerated, 2-shot coronary QISS MRA and clinical standard contrast-enhanced (CE) MRA in 14 patients with CHD (mean age, 17.0 ± 8.6 years, 6 females and 8 males). We evaluated the feasibility of single-shot coronary QISS MRA by retrospectively undersampling the 2-shot data set by an additional factor of 2, performing CS reconstruction, and comparing the retrospectively derived single-shot QISS MRA to 2-shot coronary QISS MRA and clinical standard CE MRA. For quantitative analysis, structural similarity index and normalized root mean square error were calculated. For qualitative analysis, 2 experienced readers scored the conspicuity of coronary origins on a 5-point Likert scale (1 = nondiagnostic, 2 = poor, 3 = clinically acceptable, 4 = good, 5 = excellent). RESULTS: Compared with 2-shot QISS, single-shot QISS produced normalized root mean square error of 5.8% ± 0.8% and structural similarity index of 95.4% ± 1.6%, suggesting high data fidelity by CS reconstruction. Compared with the mean conspicuity scores for clinical CE MRA (4.2 ± 0.5 and 4.1 ± 0.6 for right and left coronary origins, respectively), the mean conspicuity scores were not significantly different (P > 0.3) for 2-shot QISS (4.4 ± 0.9 and 4.2 ± 1.1, respectively) and single-shot QISS with CS (4.3 ± 1.1 and 3.8 ± 1.3, respectively) and deemed clinically acceptable to good (scores ≥3.0). CONCLUSIONS: This study shows that it is feasible to visualize the coronary origins in patients with CHD with clinically acceptable to good image quality using single-shot coronary QISS MRA with CS.


Asunto(s)
Cardiopatías Congénitas/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Adolescente , Medios de Contraste , Estudios de Factibilidad , Femenino , Corazón/diagnóstico por imagen , Humanos , Aumento de la Imagen/métodos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
MAGMA ; 31(1): 101-113, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28608326

RESUMEN

OBJECTIVES: Our objectives involved identifying whether repeated averaging in basal and mid left ventricular myocardial levels improves precision and correlation with collagen volume fraction for 11 heartbeat MOLLI T 1 mapping versus assessment at a single ventricular level. MATERIALS AND METHODS: For assessment of T 1 mapping precision, a cohort of 15 healthy volunteers underwent two CMR scans on separate days using an 11 heartbeat MOLLI with a 5(3)3 beat scheme to measure native T 1 and a 4(1)3(1)2 beat post-contrast scheme to measure post-contrast T 1, allowing calculation of partition coefficient and ECV. To assess correlation of T 1 mapping with collagen volume fraction, a separate cohort of ten aortic stenosis patients scheduled to undergo surgery underwent one CMR scan with this 11 heartbeat MOLLI scheme, followed by intraoperative tru-cut myocardial biopsy. Six models of myocardial diffuse fibrosis assessment were established with incremental inclusion of imaging by averaging of the basal and mid-myocardial left ventricular levels, and each model was assessed for precision and correlation with collagen volume fraction. RESULTS: A model using 11 heart beat MOLLI imaging of two basal and two mid ventricular level averaged T 1 maps provided improved precision (Intraclass correlation 0.93 vs 0.84) and correlation with histology (R 2 = 0.83 vs 0.36) for diffuse fibrosis compared to a single mid-ventricular level alone. ECV was more precise and correlated better than native T 1 mapping. CONCLUSION: T 1 mapping sequences with repeated averaging could be considered for applications of 11 heartbeat MOLLI, especially when small changes in native T 1/ECV might affect clinical management.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Colágeno/metabolismo , Imagen por Resonancia Magnética/métodos , Miocardio/metabolismo , Miocardio/patología , Adulto , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/metabolismo , Estenosis de la Válvula Aórtica/patología , Biopsia , Técnicas de Imagen Cardíaca/estadística & datos numéricos , Estudios de Cohortes , Medios de Contraste , Femenino , Fibrosis , Gadolinio , Voluntarios Sanos , Frecuencia Cardíaca , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Modelos Cardiovasculares , Modelos Estadísticos , Reproducibilidad de los Resultados
4.
Eur Heart J ; 38(20): 1561-1569, 2017 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-28453721

RESUMEN

AIMS: To determine the clinical impact of lipoprotein apheresis in patients with refractory angina and raised lipoprotein(a) > 500 mg/L on the primary end point of quantitative myocardial perfusion, as well as secondary end points including atheroma burden, exercise capacity, symptoms, and quality of life. METHODS: We conducted a single-blinded randomized controlled trial in 20 patients with refractory angina and raised lipoprotein(a) > 500 mg/L, with 3 months of blinded weekly lipoprotein apheresis or sham, followed by crossover. The primary endpoint was change in quantitative myocardial perfusion reserve (MPR) assessed by cardiovascular magnetic resonance. Secondary endpoints included measures of atheroma burden, exercise capacity, symptoms and quality of life. RESULTS: The primary endpoint, namely MPR, increased following apheresis (0.47; 95% CI 0.31-0.63) compared with sham (-0.16; 95% CI - 0.33-0.02) yielding a net treatment increase of 0.63 (95% CI 0.37-0.89; P < 0.001 between groups). Improvements with apheresis compared with sham also occurred in atherosclerotic burden as assessed by total carotid wall volume (P < 0.001), exercise capacity by the 6 min walk test (P = 0.001), 4 of 5 domains of the Seattle angina questionnaire (all P < 0.02) and quality of life physical component summary by the short form 36 survey (P = 0.001). CONCLUSION: Lipoprotein apheresis may represent an effective novel treatment for patients with refractory angina and raised lipoprotein(a) improving myocardial perfusion, atheroma burden, exercise capacity and symptoms.


Asunto(s)
Angina de Pecho/terapia , Eliminación de Componentes Sanguíneos/métodos , Lipoproteína(a) , Arterias Carótidas/fisiología , Enfermedad Crónica , Circulación Coronaria/fisiología , Estudios Cruzados , Endotelio Vascular/fisiología , Tolerancia al Ejercicio , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Método Simple Ciego , Resultado del Tratamiento , Rigidez Vascular/fisiología
5.
Magn Reson Med ; 77(6): 2146-2152, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27297954

RESUMEN

PURPOSE: The presence of vascular calcifications helps to determine percutaneous access for interventional vascular procedures and has prognostic value for future cardiovascular events. Unlike CT, standard MRI techniques are insensitive to vascular calcifications. In this prospective study, we tested a proton density-weighted, in-phase (PDIP) three-dimensional (3D) stack-of-stars gradient-echo pulse sequence with approximately 1 mm3 isotropic spatial resolution at 1.5 Tesla (T) and 3T to detect iliofemoral peripheral vascular calcifications and correlated MR-determined lesion volumes with CT angiography (CTA). METHODS: The study was approved by the Institutional Review Board. The prototype PDIP stack-of-stars pulse sequence was applied in 12 patients with iliofemoral peripheral vascular calcifications who had undergone CTA. RESULTS: Vascular calcifications were well visualized in all subjects, excluding segments near prostheses or stents. The location, size, and shape of the calcifications were similar to CTA. Quantitative analysis showed excellent correlation (r2 = 0.84; P < 0.0001) between MR- and CT-based measures of calcification volume. In one subject in whom three pulse sequences were compared, PDIP stack-of-stars outperformed cartesian 3D gradient-echo and point-wise encoding time reduction with radial acquisition (PETRA). CONCLUSION: In this pilot study, a PDIP 3D stack-of-stars gradient-echo pulse sequence with high spatial resolution provided excellent image quality and accurately depicted the location and volume of iliofemoral vascular calcifications. Magn Reson Med 77:2146-2152, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Arteria Femoral/diagnóstico por imagen , Arteria Ilíaca/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Calcificación Vascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Prótesis de Cadera , Humanos , Illinois , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Proyectos Piloto , Protones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
6.
J Cardiovasc Magn Reson ; 19(1): 48, 2017 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-28662717

RESUMEN

BACKGROUND: For evaluation of the pulmonary arteries in patients suspected of pulmonary embolism, CT angiography (CTA) is the first-line imaging test with contrast-enhanced MR angiography (CEMRA) a potential alternative. Disadvantages of CTA include exposure to ionizing radiation and an iodinated contrast agent, while CEMRA is sensitive to respiratory motion and requires a gadolinium-based contrast agent. The primary goal of our technical feasibility study was to evaluate pulmonary arterial conspicuity using breath-hold and free-breathing implementations of a recently-developed nonenhanced approach, single-shot radial quiescent-interval slice-selective (QISS) MRA. METHODS: Breath-hold and free-breathing, navigator-gated versions of radial QISS MRA were evaluated at 1.5 Tesla in three healthy subjects and 11 patients without pulmonary embolism or arterial occlusion by CTA. Images were scored by three readers for conspicuity of the pulmonary arteries through the level of the segmental branches. In addition, one patient with pulmonary embolism was imaged. RESULTS: Scan time for a 54-slice acquisition spanning the pulmonary arteries was less than 2 minutes for breath-hold QISS, and less than 3.4 min using free-breathing QISS. Pulmonary artery branches through the segmental level were conspicuous with either approach. Free-breathing scans showed only mild blurring compared with breath-hold scans. For both readers, less than 1% of pulmonary arterial segments were rated as "not seen" for breath-hold and navigator-gated QISS, respectively. In subjects with atrial fibrillation, single-shot radial QISS consistently depicted the pulmonary artery branches, whereas navigator-gated 3D balanced steady-state free precession showed motion artifacts. In one patient with pulmonary embolism, radial QISS demonstrated central pulmonary emboli comparably to CEMRA and CTA. The thrombi were highly conspicuous on radial QISS images, but appeared subtle and were not prospectively identified on scout images acquired using a single-shot bSSFP acquisition. CONCLUSIONS: In this technical feasibility study, both breath-hold and free-breathing single-shot radial QISS MRA enabled rapid, consistent demonstration of the pulmonary arteries through the level of the segmental branches, with only minimal artifacts from respiratory motion and cardiac arrhythmias. Based on these promising initial results, further evaluation in patients with suspected pulmonary embolism appears warranted.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Anciano , Artefactos , Contencion de la Respiración , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
7.
J Comput Assist Tomogr ; 41(6): 854-860, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28708731

RESUMEN

OBJECTIVE: The purpose of this study is to evaluate feasibility, image quality (IQ), and accuracy of noncontrast hybrid arterial spin labeling (NoHASL) magnetic resonance angiography (MRA) compared with time of flight (TOF) MRA and contrast-enhanced (CE) MRA in patients with known/suspected cerebrovascular ischemia. METHODS: Thirty inpatients were imaged at 1.5 T. Two neuroradiologists assessed 630 intracranial arterial segments for IQ (1, nondiagnostic; 3, satisfactory for diagnosis; and 5, excellent). Hemodynamically significant stenosis (>50%) was assessed against all combined techniques as reference. RESULTS: The NoHASL MRA IQ was diagnostic (3.32 ± 0.86) but affected by signal to noise ratio and spatial resolution limitations and significantly inferior to TOF (3.48 ± 0.68) and CE MRA (3.44 ± 0.78) (P < 0.0001 in both comparisons). Fourteen (2.2%) of 630 segments had hemodynamically significant stenoses at the reference standard. Sensitivity/specificity was not significantly different between techniques: NoHASL MRA, 67.9%/90.0%; TOF MRA, 67.9%/97.7%; and CE MRA, 50.0%/98.7%. CONCLUSIONS: The NoHASL MRA is feasible, with diagnostic quality imaging of proximal intracranial vessels. Low disease prevalence limited the assessment of technique accuracy.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Neuroimagen/métodos , Marcadores de Spin , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
8.
Magn Reson Med ; 75(5): 2072-7, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26072706

RESUMEN

PURPOSE: To test the feasibility of a quiescent interval low-angle shot (QLASH) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries at 3 T. METHODS: The extracranial carotid arteries were imaged using QLASH MRA in healthy volunteers and patients with carotid arterial disease. The impact of three gating strategies (electrocardiographic-gated, pulse-gated, ungated) was evaluated. Image quality comparisons were made with respect to two-dimensional (2D) time of flight (TOF) MRA in volunteers and patients and contrast-enhanced MRA (CEMRA) in patients. Stenoses in patients were graded. RESULTS: QLASH MRA displayed the entire extent of the extracranial carotid arteries from their origins to the skull base. Electrocardiographic-gated QLASH MRA provided better image quality than pulse-gated and ungated implementations (P < 0.05) as well as 2D TOF MRA (P < 0.05). For grading of disease, QLASH MRA showed almost perfect agreement with CEMRA (Cohen's kappa = 0.86, P < 0.001) in a small cohort of patients with carotid arterial stenosis. CONCLUSION: QLASH MRA allows for evaluation of the entire extent of the extracranial carotid arteries with an average scan time of less than 6 min and better image quality than 2D TOF. Initial clinical results in this pilot study suggest that QLASH has potential utility as a nonenhanced alternative to CEMRA.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/patología , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/patología , Angiografía por Resonancia Magnética , Adulto , Anciano , Artefactos , Estenosis Carotídea/patología , Medios de Contraste , Electrocardiografía , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Relación Señal-Ruido
9.
Magn Reson Med ; 75(1): 295-301, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25684192

RESUMEN

PURPOSE: To quantify the accuracy of three-dimensional (3D) radial arterial spin labeled (ASL) magnetic resonance angiography (MRA) using vascular models of carotid stenosis. METHODS: Eight vascular models were imaged at 1.5 Tesla using pulsatile flow waveforms at rates found in the internal carotid arteries (100-400 mL/min). The impacts of the 3D ASL imaging readout (fast low angle shot (FLASH) versus balanced steady-state free precession (bSSFP)), ultrashort echo time imaging using a pointwise encoding time reduction with radial acquisition (PETRA), and model stenosis severity on the accuracy of vascular model display at the location of stenosis were quantified. Accuracy was computed vis-à-vis a reference bSSFP volume acquired under no flow. Comparisons were made with standard-of-care contrast-enhanced MRA (CEMRA) and Cartesian time-of-flight (TOF) MRA protocols. RESULTS: For 50% and 70% stenoses, CEMRA was most accurate (respective accuracies of 81.7% and 78.6%), followed by ASL FLASH (75.7% and 71.8%), ASL PETRA (69.6% and 70.6%), 3D TOF (66.6% and 57.1%), ASL bSSFP (68.7% and 51.2%), and 2D TOF (65.1% and 50.6%). CONCLUSION: Flow phantom imaging studies show that ASL MRA can improve the display of hemodynamically significant carotid arterial stenosis compared with TOF MRA, with FLASH and ultrashort echo time readouts being most accurate.


Asunto(s)
Arterias Carótidas/anatomía & histología , Arterias Carótidas/fisiología , Circulación Cerebrovascular/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Velocidad del Flujo Sanguíneo/fisiología , Humanos , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Marcadores de Spin
10.
J Cardiovasc Magn Reson ; 18(1): 69, 2016 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-27756330

RESUMEN

BACKGROUND: Dark blood imaging of the heart is conventionally performed using a breath-hold, dual-inversion Cartesian fast spin-echo pulse sequence. Our aim was to develop a faster, more flexible approach that would be less motion-sensitive and provide better image quality. For this purpose, we implemented a prototype radial balanced steady-state free precession (bSSFP) pulse sequence. METHODS: The study was approved by the institutional review board. Six healthy volunteers and 27 subjects undergoing clinically-indicated cardiovascular magnetic resonance (CMR) were imaged using dark blood Cartesian fast spin-echo and radial bSSFP. For patient studies, overall image quality, fat suppression and blood nulling were scored on a 5-point Likert scale. The quality of visualization of the right and left ventricular free walls and septum were individually scored. Streaking and ghosting artifacts were noted, as well as signal dropout in the free wall of the left ventricle. RESULTS: In volunteer studies, radial bSSFP showed less degradation by cardiac or respiratory motion than fast spin-echo as indicated by visual analysis and calculation of the temporal signal-to-noise ratio. The least motion sensitivity and maximal imaging efficiency were achieved with a single-shot radial bSSFP acquisition using only 35 views (temporal resolution = 95 ms). In patient studies, radial bSSFP images showed fewer motion artifacts and were judged to provide better myocardial visibility, including depiction of the right ventricular free wall, than fast spin-echo. CONCLUSIONS: Dual-inversion radial bSSFP provides the benefits of diminished sensitivity to image artifacts from respiratory or cardiac motion, better myocardial visibility, and improved imaging efficiency compared with standard-of-care Cartesian fast spin-echo for dark blood imaging of the heart.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Contencion de la Respiración , Femenino , Corazón/fisiopatología , Cardiopatías/fisiopatología , Frecuencia Cardíaca , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Mecánica Respiratoria , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
11.
J Cardiovasc Magn Reson ; 18(1): 71, 2016 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-27760564

RESUMEN

BACKGROUND: The high incidence of renal insufficiency in patients with Peripheral Arterial Disease raises the concern for nephrogenic systemic fibrosis (NSF) with respect to contrast enhanced MRA. The risk of NSF is eliminated with non-contrast enhanced magnetic resonance angiography. The purpose of the current study is to compare image quality and diagnostic performance of non-contrast enhanced Quiescent Interval Single Shot (QISS) magnetic resonance angiography at 3 T versus CT angiography for evaluation of lower extremity Peripheral Arterial Disease (PAD). METHODS: 32 consecutive patients (23 male, 9 female, age range 40-81 years, average age 61.97 years) with clinically suspected lower extremity PAD underwent QISS MRA and CTA. 19 of 32 patients underwent Digital Subtraction Angiography (DSA). Image quality of MRA was compared with CTA by two radiologists with 10 and 8 years' experience according to a 4-point scale. The Kappa test was used to determine the intermodality agreement between MRA and CTA in stenosis assessment, and interobserver agreement with each method. Sensitivity and specificity of CTA and MRA in detecting hemodynamically significant stenosis (≥50 %) were compared, with DSA serving as reference standard when available. RESULTS: Image quality of QISS MRA was rated 3.70 ± 0.49 by reader 1, and 3.72 ± 0.47 by reader 2, significantly lower than that of CTA (3.80 ± 0.44 and 3.82 ± 0.42, P < 0.001 for both readers). Intermodality agreement between MRA and CTA was excellent for assessment of stenosis (Kappa = 0.923 ± 0.013 for reader 1, 0.930 ± 0.012 for reader 2). Interobserver agreement was 0.936 ± 0.012 for CTA and 0.935 ± 0.011 for MRA. For readers 1 and 2 respectively, the sensitivity of QISS was 94.25 and 93.26 % (versus 90.11 and 89.13 % for CTA, P > 0.05), and specificity of QISS was 96.70 and 97.75 % (versus 96.55 and 96.51 % for CTA, P > 0.05). For heavily calcified segments, sensitivity of QISS (95.83 and 95.83 %) was significantly higher than that of CTA (74.19 and 76.67 %, P < 0.05). CONCLUSION: QISS is a reliable alternative to CTA for evaluation of lower extremity PAD, and may be suitable as a first-line screening examination in patients with contraindications to intravenous contrast administration.


Asunto(s)
Arterias/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Extremidad Inferior/irrigación sanguínea , Angiografía por Resonancia Magnética/métodos , Enfermedad Arterial Periférica/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Arterias/fisiopatología , Angiografía por Tomografía Computarizada/normas , Constricción Patológica , Hemodinámica , Humanos , Angiografía por Resonancia Magnética/normas , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Enfermedad Arterial Periférica/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Estándares de Referencia , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
12.
J Cardiovasc Magn Reson ; 18(1): 62, 2016 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-27659737

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) phantoms are routinely used for quality assurance in MRI centres; however their long term stability for verification of myocardial T1/ extracellular volume fraction (ECV) mapping has never been investigated. METHODS: Nickel-chloride agarose gel phantoms were formulated in a reproducible laboratory procedure to mimic blood and myocardial T1 and T2 values, native and late after Gadolinium administration as used in T1/ECV mapping. The phantoms were imaged weekly with an 11 heart beat MOLLI sequence for T1 and long TR spin-echo sequences for T2, in a carefully controlled reproducible manner for 12 months. RESULTS: There were only small relative changes seen in all the native and post gadolinium T1 values (up to 9.0 % maximal relative change in T1 values) or phantom ECV (up to 8.3 % maximal relative change of ECV, up to 2.2 % maximal absolute change in ECV) during this period. All native and post gadolinium T2 values remained stable over time with <2 % change. Temperature sensitivity testing showed MOLLI T1 values in the long T1 phantoms increasing by 23.9 ms per degree increase and short T1 phantoms increasing by 0.3 ms per degree increase. There was a small absolute increase in ECV of 0.069 % (~0.22 % relative increase in ECV) per degree increase. Variation in heart rate testing showed a 0.13 % absolute increase in ECV (~0.45 % relative increase in ECV) per 10 heart rate increase. CONCLUSIONS: These are the first phantoms reported in the literature modeling T1 and T2 values for blood and myocardium specifically for the T1mapping/ECV mapping application, with stability tested rigorously over a 12 month period. This work has significant implications for the utility of such phantoms in improving the accuracy of serial scans for myocardial tissue characterisation by T1 mapping methods and in multicentre work.

13.
Magn Reson Med ; 73(5): 1939-45, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24957402

RESUMEN

PURPOSE: Both CT and MR angiography are accurate for the evaluation of luminal abnormalities in peripheral arterial disease (PAD). However, only CT (requiring exposure to potentially hazardous ionizing radiation) provides a reliable means to detect vascular calcifications. In this study, we demonstrate the feasibility of detecting peripheral arterial calcifications with MRI. METHODS: The institutional investigational review board approved the study. Seven patients with PAD and iliofemoral arterial calcifications shown by prior CT angiography (CTA) were studied. The imaging techniques included: 1) dual-echo three-dimensional (3D) gradient recalled echo (GRE) pulse sequence using flow compensation and in-phase echo times (TE); and 2) prototype version of 3D point-wise encoding time reduction with radial acquisition (PETRA), which enables imaging with an ultra-short TE. RESULTS: With both techniques after grayscale inversion, vascular calcifications appeared bright, as did cortical bone, and were readily distinguished from the vessel lumen and surrounding soft tissues. The location and conformation of the calcifications corresponded with CT. The second echo GRE provided the highest contrast-to-noise ratios; whereas PETRA was best suited for the creation of thick projection images. CONCLUSION: In this pilot study, MRI was able to detect vascular calcifications. Projection imaging using PETRA provided a similar appearance to, and allowed direct comparison with, CT.


Asunto(s)
Calcinosis/diagnóstico , Imagen Eco-Planar/métodos , Arteria Femoral/patología , Arteria Ilíaca/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Enfermedad Arterial Periférica/diagnóstico , Anciano , Angiografía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
14.
Magn Reson Med ; 74(5): 1266-78, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25385540

RESUMEN

PURPOSE: For the application of compressive sensing to parallel MRI, Poisson disk sampling (PDS) has been shown to generate superior results compared with random sampling methods. However, due to its limited flexibility to incorporate additional constraints, PDS is not readily extendible to dynamic applications. Here, we propose and validate a pseudo-random sampling technique that allows incorporating constraints specific to dynamic imaging. METHODS: The proposed sampling scheme, called variable density incoherent spatiotemporal acquisition (VISTA), is based on constrained minimization of Riesz energy on a spatiotemporal grid. Data from both a digital phantom and real-time cine were used to compare VISTA with uniform interleaved sampling (UIS) and variable density random sampling (VRS). The image quality was assessed qualitatively and quantitatively. RESULTS: VISTA improved the trade-off between noise and sharpness. Also, VISTA produced diagnostic quality images at an acceleration rate of 15, whereas UIS and VRS images degraded below the diagnostic threshold at lower acceleration rates. CONCLUSIONS: VISTA generates spatiotemporal sampling patterns with high levels of uniformity and incoherence, while maintaining a constant temporal resolution. Using a small pilot study, VISTA was shown to produce diagnostic quality images at acceleration rates up to 15.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Análisis de Ondículas , Simulación por Computador , Humanos , Fantasmas de Imagen
15.
J Magn Reson Imaging ; 41(4): 1150-6, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24737420

RESUMEN

PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution.


Asunto(s)
Algoritmos , Arterias Carótidas/patología , Estenosis Carotídea/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Marcadores de Spin
16.
Magn Reson Med ; 72(4): 1079-86, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24407879

RESUMEN

PURPOSE: To describe a pulse sequence for simultaneous static and cine nonenhanced magnetic resonance angiography (NEMRA) of the peripheral arteries. METHODS: The peripheral arteries of 10 volunteers and 6 patients with peripheral arterial disease (PAD) were imaged with the proposed cine NEMRA sequence on a 1.5 Tesla (T) system. The impact of multi-shot imaging and highly constrained back projection (HYPR) reconstruction was examined. The propagation rate of signal along the length of the arterial tree in the cine nonenhanced MR angiograms was quantified. RESULTS: The cine NEMRA sequence simultaneously provided a static MR angiogram showing vascular anatomy as well as a cine display of arterial pulse wave propagation along the entire length of the peripheral arteries. Multi-shot cine NEMRA improved temporal resolution and reduced image artifacts. HYPR reconstruction improved image quality when temporal reconstruction footprints shorter than 100 ms were used (P < 0.001). Pulse wave propagation within the arterial tree as displayed by cine NEMRA was slower in patients with PAD than in volunteers. CONCLUSION: Simultaneous static and cine NEMRA of the peripheral arteries is feasible. Multi-shot acquisition and HYPR reconstruction can be used to improve arterial conspicuity and temporal resolution.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen Multimodal/métodos , Enfermedad Arterial Periférica/patología , Técnica de Sustracción , Anciano , Medios de Contraste , Estudios de Factibilidad , Humanos , Aumento de la Imagen/métodos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Tamaño de la Muestra , Sensibilidad y Especificidad
17.
Magn Reson Med ; 72(6): 1522-9, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25257379

RESUMEN

PURPOSE: We hypothesized that non-contrast-enhanced MR angiography (NEMRA) could be performed without cardiac gating by using a variant of the quiescent-inflow single-shot (QISS) technique. METHODS: Ungated QISS (UnQISS) MRA was evaluated in eight patients with peripheral arterial disease at 1.5T. The radial acquisition used optimized azimuthal equidistant projections, a long quiescent inflow time (1200 ms) to ensure replenishment of saturated in-plane spins irrespective of the cardiac phase, and a lengthy readout (1200 ms) so that a complete cardiac cycle was sampled for each slice. Venous and background tissue suppression was obtained using frequency-offset-corrected inversion radiofrequency pulses. RESULTS: Scan time for UnQISS was 15.4 min for an eight-station whole-leg acquisition. The appearance of UnQISS MRA acquired using the body coil was comparable to electrocardiographic-gated QISS MRA using phased array coils. A small radial view angle increment minimized eddy current-related artifacts, whereas image quality was inferior with a golden view angle radial increment or Cartesian trajectory. In patient studies, ≥50% stenoses were consistently detected. CONCLUSION: Using UnQISS, peripheral NEMRA can be performed without the need for cardiac gating. The use of fixed imaging parameters and body coil for signal reception further simplifies the scan procedure.


Asunto(s)
Algoritmos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Enfermedad Arterial Periférica/patología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Pierna/irrigación sanguínea , Pierna/patología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
18.
Magn Reson Med ; 71(1): 133-44, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23440705

RESUMEN

PURPOSE: To describe and characterize a new approach to first-pass myocardial perfusion utilizing balanced steady-state free precession acquisition without the use of saturation recovery or other magnetization preparation. THEORY: The balanced steady-state free precession sequence is inherently sensitive to contrast agent enhancement of the myocardium. This sensitivity can be used to advantage in first-pass myocardial perfusion imaging by eliminating the need for magnetization preparation. METHODS: Bloch equation simulations, phantom experiments, and in vivo 2D imaging studies were run comparing the proposed technique with three other methods: saturation recovery spoiled gradient echo, saturation recovery steady-state free precession, and steady-state spoiled gradient echo without magnetization preparation. Additionally, an acquisition-reconstruction strategy for 3D perfusion imaging is proposed and initial experience with this approach is demonstrated in healthy subjects and one patient. RESULTS: Phantom experiments verified simulation results showing the sensitivity of the balanced steady-state free precession sequence to contrast agent enhancement in solid tissue is similar to that of magnetization-prepared acquisitions. Images acquired in normal volunteers showed the proposed technique provided superior signal and signal-to-noise ratio compared with all other sequences at baseline as well as postcontrast. CONCLUSIONS: A new approach to first-pass myocardial perfusion is presented that obviates the need for magnetization preparation and provides high signal-to-noise ratio.


Asunto(s)
Algoritmos , Vasos Coronarios/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Humanos , Aumento de la Imagen/métodos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Magn Reson Med ; 68(5): 1570-8, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22851292

RESUMEN

Quantitative T2 mapping was recently shown to be superior to T2-weighted imaging in detecting T2 changes across myocardium. Pixel-wise T2 mapping is sensitive to misregistration between the images used to generate the parameter map. In this study, utility of two motion-compensation strategies-(i) navigator gating with prospective slice correction and (ii) nonrigid registration-was investigated for myocardial T2 mapping in short axis and horizontal long axis views. Navigator gating provides respiratory motion compensation, whereas registration corrects for residual cardiac and respiratory motion between images; thus, the two strategies provided complementary functions. When these were combined, respiratory-motion-induced T2 variability, as measured by both standard deviation and interquartile range, was comparable to that in breath-hold T2 maps. In normal subjects, this combined motion-compensation strategy increased the percentage of myocardium with T2 measured to be within normal range from 60.1% to 92.2% in short axis and 62.3% to 92.7% in horizontal long axis. The new motion-compensated T2 mapping technique, which combines navigator gating, prospective slice correction, and nonrigid registration to provide through-plane and in-plane motion correction, enables a method for fully automatic and robust free-breathing T2 mapping.


Asunto(s)
Artefactos , Corazón/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Algoritmos , Humanos , Movimiento (Física) , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA