2.
Ann Surg Oncol ; 26(11): 3510-3516, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31297674

RESUMEN

BACKGROUND: Sentinel lymph node biopsy (SLNB) is a highly accurate method for staging the axilla in early breast cancer. Superparamagnetic iron oxide mapping agents have been explored to overcome the disadvantages of the standard SLNB technique, which uses a radioisotope tracer with or without blue dye. One such agent, Sienna+, was shown to be non-inferior to the standard technique for SLNB in a number of studies. The SentimagIC trial was designed to establish the non-inferiority of a new formulation of this magnetic tracer, Magtrace (formerly SiennaXP). METHODS: Patients with clinically node-negative early-stage breast cancer were recruited from six centers in the US. Patients received radioisotope and isosulfan blue dye injections, followed by an intraoperative injection of magnetic tracer, prior to SLNB. The sentinel node identification rate was compared between the magnetic and standard techniques to evaluate non-inferiority and concordance. RESULTS: Data were collected for 146 procedures in 146 patients. The per patient detection rate was 99.3% (145/146) when using the magnetic tracer and 98.6% (144/146) when using the standard technique, while the nodal detection rate was 94.3% (348/369 nodes) when using the magnetic tracer and 93.5% (345/369) when using the standard technique (difference 0.8%, 95% binomial confidence interval lower bound - 2.1%). Of the 22 patients with positive sentinel lymph nodes (SLNs), 21 (95.4%) were detected by both the magnetic tracer and the standard technique. All malignant nodes detected by standard technique were also identified by the magnetic technique. CONCLUSION: The magnetic technique is non-inferior to the standard technique of radioisotope and blue dye for axillary SLN detection in early-stage breast cancer. The magnetic technique is therefore a viable alternative.


Asunto(s)
Neoplasias de la Mama/patología , Carcinoma Ductal de Mama/patología , Compuestos Férricos , Nanopartículas de Magnetita , Colorantes de Rosanilina , Ganglio Linfático Centinela/patología , Tecnecio , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/cirugía , Estudios de Equivalencia como Asunto , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Estudios Prospectivos , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/cirugía , Biopsia del Ganglio Linfático Centinela
3.
JCO Precis Oncol ; 6: e2100463, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35476550

RESUMEN

PURPOSE: The 80-gene molecular subtyping signature (80-GS) reclassifies a proportion of immunohistochemistry (IHC)-defined luminal breast cancers (estrogen receptor-positive [ER+], human epidermal growth factor receptor 2-negative [HER2-]) as Basal-Type. We report the association of 80-GS reclassification with neoadjuvant treatment response and 5-year outcome in patients with breast cancer. METHODS: Neoadjuvant Breast Registry Symphony Trial (NBRST; NCT01479101) is an observational, prospective study that included 1,069 patients with early-stage breast cancer age 18-90 years who received neoadjuvant therapy. Pathologic complete response (pCR) and 5-year distant metastasis-free survival (DMFS) and overall survival (OS) were assessed in 477 patients with IHC-defined ER+, HER2- tumors and in a reference group of 229 patients with IHC-defined triple-negative breast cancer (TNBC). RESULTS: 80-GS reclassified 15% of ER+, HER2- tumors (n = 73) as Basal-Type (ER+/Basal), which had similar pCR compared with TNBC/Basal tumors (34% v 38%; P = .52), and significantly higher pCR than ER+/Luminal A (2%; P < .001) and ER+/Luminal B (6%; P < .001) tumors. The 5-year DMFS (%, [95% CI]) was significantly lower for patients with ER+/Basal tumors (66% [52.6 to 77.3]), compared with those with ER+/Luminal A tumors (92.3% [85.2 to 96.1]) and ER+/Luminal B tumors (73.5% [44.5 to 79.3]). Importantly, patients with ER+/Basal or TNBC/Basal tumors that had a pCR exhibited significantly improved DMFS and OS compared with those with residual disease. By contrast, patients with ER+/Luminal B tumors had comparable 5-year DMFS and OS whether or not they achieved pCR. CONCLUSION: Significant differences in chemosensitivity and 5-year outcome suggest patients with ER+/Basal molecular subtype may benefit from neoadjuvant regimens optimized for patients with TNBC/Basal tumors compared with patients with ER+/Luminal subtype. These data highlight the importance of identifying this subset of patients to improve treatment planning and long-term survival.


Asunto(s)
Terapia Neoadyuvante , Neoplasias de la Mama Triple Negativas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Receptor ErbB-2 , Receptores de Estrógenos/genética , Receptores de Progesterona/análisis , Neoplasias de la Mama Triple Negativas/tratamiento farmacológico , Adulto Joven
4.
Breast J ; 17(2): 143-51, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21276128

RESUMEN

Molecular imaging, using positron emission tomography (PET), has become an integral step in the evaluation of many patients with malignancy. However, its use in patients with breast cancer has been limited by the lower levels of (18) F-fluorodeoxyglucose (FDG) uptake in some breast malignancies compared to other cancers, the small size of many breast cancers, and the need for biopsy under PET guidance. High-resolution breast PET, or positron emission mammography (PEM), with biopsy guidance software, now addresses these issues. We report a prospective, multicenter study designed to test the efficacy and safety of PEM biopsy guidance software in women with FDG-avid breast lesions worrisome for malignancy. The intervention chosen was vacuum-assisted core biopsy. Nineteen subjects underwent a total of 24 PEM-guided biopsies. All lesions were successfully targeted and sampled as determined by post-biopsy image scan evaluation, specimen imaging, and pathologic concordance. Invasive cancer was identified in 13 of 24 lesions (54%), while four (17%) were high-risk lesions and three of these were upgraded to malignancy at excision. No serious adverse events occurred and all patients found the procedure to cause only minimal to mild discomfort. High-resolution PEM-guided breast biopsy is both safe and effective for the sampling of PET-depicted breast lesions.


Asunto(s)
Mama/diagnóstico por imagen , Mama/patología , Tomografía de Emisión de Positrones , Cirugía Asistida por Computador , Anciano , Anciano de 80 o más Años , Biopsia/efectos adversos , Biopsia/métodos , Femenino , Fluorodesoxiglucosa F18 , Humanos , Mamografía/métodos , Persona de Mediana Edad , Invasividad Neoplásica , Estudios Prospectivos , Radiofármacos , Programas Informáticos , Resultado del Tratamiento
5.
Breast J ; 15(1): 93-100, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19141135

RESUMEN

Although two-thirds of invasive breast cancers and half of non-invasive breast cancers are amenable to lumpectomy, only about 70% of such patients choose breast conservation. Of that group, up to one-third do not follow-up with radiation therapy despite it being clinically indicated. The reasons include the patient's and surgeon's attitude toward breast conservation as well as the inconvenience and distance of a suitable radiation facility. The advent of shorter courses of radiation therapy may encourage more patients to seek adjuvant therapy. An increasingly popular and more convenient alternative to traditional whole-breast radiation therapy in patients with early-stage breast cancer is accelerated partial breast irradiation (APBI), for which the American Society of Breast Surgeons and the American Brachytherapy Society have promulgated guidelines for candidate selection. Although several methods are emerging, the most widely used brachytherapy technique utilizes the MammoSite single-catheter balloon brachytherapy device. In a best practices symposium convened in 2006, breast surgeons from academic and community practices with extensive experience in balloon brachytherapy developed general guidelines for integrating APBI into a breast surgical practice. Important considerations include patient age, histology, tumor location and size, and breast size. Thoughtful lumpectomy planning is essential to optimize balloon placement. Real-time sonographic guidance is essential as the surgeon should attend closely to volume excised and cavity shape. A cavity evaluation device can act as a place holder while patient suitability for APBI is considered. Many breast surgeons expert in this procedure insert the balloon catheter in the office either through a de novo skin entrance site removed from the lumpectomy incision or through the original incision. Optimally, insertion occurs within 2-3 weeks after lumpectomy. Close and continual communication with the radiation oncologist is essential to assure optimal outcomes. In this review, several key aspects of a successful APBI program from a surgeon's perspective as well as a consensus panel from a best practices symposium on the topic herein are highlighted.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Mastectomía Segmentaria , Rol del Médico , Adulto , Anciano , Terapia Combinada , Femenino , Humanos , Persona de Mediana Edad
6.
Arch Surg ; 139(6): 603-7; discussion 607-8, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15197085

RESUMEN

HYPOTHESIS: Partial-breast irradiation for carcinoma by a single source of radiation placed in the center of a balloon inserted in the lumpectomy cavity is an effective method of treating breast cancer. Previous interstitial radiation therapy using iridium seeds placed within multiple catheters has been shown to be effective but impractical and cosmetically unacceptable to women. DESIGN: Prospective registry study. SETTING: Three university and community hospitals. PATIENTS: Women 40 years and older with histologically diagnosed in situ and invasive T1 through T2 and N0 or N1 breast cancer treated with lumpectomy and axillary node sampling were invited to enter this institutional review board-approved study. MAIN OUTCOME MEASURES: Evaluation of immediate and short-term complications, patients' acceptance of the treatment, and cosmesis are reported. RESULTS: Of the 129 eligible patients enrolled, 112 completed the treatment. Of these, transient skin erythema was noted in 28, localized edema in 3, and skin blisters adjacent to the balloon in 9. Infection developed in 7, necessitating drainage and antibiotic administration. In 10 patients, sonographically demonstrated seromas that developed after removal of the device were aspirated percutaneously. In 4 patients, punctured or ruptured balloons had to be replaced before the treatment could be completed. Patients quickly adjusted to the breast distension caused by the balloon, and their acceptance of the procedure was good. The cosmetic outcome was rated high. There were no recurrences during this very short follow-up. CONCLUSIONS: Our early short-term experience indicates balloon brachytherapy to be an acceptable alternative to external beam radiation for selected operable breast cancers. The 1-week treatment time allows working women and those who live at a distance from radiation centers to choose breast conservation rather than mastectomy.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Intraductal no Infiltrante/radioterapia , Carcinoma Lobular/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/cirugía , Carcinoma Intraductal no Infiltrante/cirugía , Carcinoma Lobular/cirugía , Femenino , Humanos , Mastectomía Segmentaria/métodos , Persona de Mediana Edad , Estudios Prospectivos , Radioterapia Adyuvante/métodos , Resultado del Tratamiento
7.
Am J Surg ; 186(4): 386-90, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14553856

RESUMEN

BACKGROUND: This review was made to evaluate whether the efficiencies of intraoperative ultrasound-guided localization could be extended to stereotactic biopsy cases by using a marker visible by sonography and mammography. METHODS: A retrospective review identified 170 stereotactic directional vacuum-assisted biopsy (DVAB) procedures marked with an ultrasound-visible marker. Localization device, imaging method, lesion retrieval, and margin status were assessed for patients having subsequent lumpectomy or wider excision. RESULTS: Nineteen of 170 patients underwent lumpectomies (12) or wider excision (7) localized by a radiofrequency device or 18G needle up to 7 weeks after stereotactic biopsy. In 15 of 19 procedures, an ultrasound-guided localization was performed intraoperatively, targeting the marker. All targeted lesions were successfully excised. In the 13 malignant lesions (of 19 surgeries), only 1 had a positive margin (8%). CONCLUSIONS: Marking stereotactic biopsies with a sonographically visible marker allows ultrasound-guided intraoperative localization, improving efficiencies for the patient, surgeon, and operating room schedule.


Asunto(s)
Biopsia/métodos , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Mastectomía Segmentaria , Ultrasonografía Intervencional , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Femenino , Humanos , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Técnicas Estereotáxicas , Ultrasonografía Mamaria
8.
Am J Surg ; 198(1): 83-91, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19268900

RESUMEN

BACKGROUND: We present a 4-year update on the efficacy, cosmetic results, and complications of MammoSite breast brachytherapy in patients enrolled in the American Society of Breast Surgeons registry trial. METHODS: A total of 1,449 breasts in 1,440 patients with early stage breast cancer undergoing breast-conserving therapy were treated with adjuvant, accelerated partial breast irradiation (APBI) (34 Gy in 3.4-Gy fractions) delivered with the MammoSite device. The median follow-up period for the entire group was 36.1 months. RESULTS: The 3-year actuarial rate of ipsilateral breast tumor recurrence was 2.15%. The 3-year actuarial rate of axillary recurrence was .36%. Complication rates were as follows: infection, 9.5%; seroma, 26.8% (symptomatic seroma, 12.7%); and fat necrosis, 2.0%. The percentages of breasts with good or excellent cosmetic results were as follows: 12 months, 95%; 24 months, 94%; 36 months, 94%; and 48 months, 91%. CONCLUSIONS: Locoregional control, complications, and cosmetic outcomes from MammoSite APBI at the 4-year update are acceptable and similar to results seen with other forms of APBI.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Sociedades Médicas , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/mortalidad , Neoplasias de la Mama/patología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Persona de Mediana Edad , Recurrencia Local de Neoplasia/epidemiología , Estadificación de Neoplasias , Estudios Prospectivos , Dosificación Radioterapéutica/normas , Factores de Riesgo , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
9.
Cancer ; 112(4): 758-66, 2008 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-18181095

RESUMEN

BACKGROUND: This report presents 3 years of data on treatment efficacy, cosmetic results, and toxicities for patients enrolled on the American Society of Breast Surgeons MammoSite (Cytyc, Bedford, Mass) Breast Brachytherapy Registry Trial. METHODS: A total of 1440 patients (1449 cases) with early stage breast cancer who were undergoing breast-conserving therapy were treated with the MammoSite device to deliver accelerated partial breast irradiation (APBI) (34 Gy in 3.4 Gy fractions). Of these, 1255 (87%) cases had invasive breast cancer (IBC; median size = 10 mm), and 194 (13%) cases had ductal carcinoma in situ (DCIS; median size = 8 mm). Median follow-up was 30.1 months. RESULTS: Twenty-three (1.6%) cases developed an ipsilateral breast tumor recurrence (IBTR) for a 2-year actuarial rate of 1.04% (1.11% for IBC and 0.59% for DCIS). No variables were associated with IBTR. Six (0.4%) patients developed an axillary failure. The percentages of breasts with good to excellent cosmetic results at 12 (n = 980), 24 (n = 752), 36 (n = 403), and 48 months (n = 67 cases) were 95%, 94%, 93%, and 93%, respectively. Breast seromas were reported in 23.9% of cases (30% in open-cavity implants and 19% in closed-cavity implants). Symptomatic seromas occurred in 10.6% of cases, and 1.5% of cases developed fat necrosis. A subset analysis of the first 400 consecutive cases enrolled was performed (352 with IBC, 48 DCIS). With a median follow-up of 37.5 months, the 3-year actuarial rate of IBTR was 1.79%. CONCLUSIONS: Treatment efficacy, cosmesis, and toxicity 3 years after treatment with APBI using the MammoSite device are good and similar to those reported with other forms of APBI with similar follow-up.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Mama/efectos de la radiación , Adulto , Braquiterapia/efectos adversos , Mama/patología , Neoplasias de la Mama/patología , Estética , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Dosis de Radiación , Sistema de Registros/estadística & datos numéricos , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
10.
Breast J ; 13(1): 36-43, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17214791

RESUMEN

The purpose of this study was to evaluate performance, ergonomics, and immediate rebiopsy rate of a new vacuum-assisted biopsy (VAB) device for ultrasound-guided breast biopsies. Between December 2002 and April 2003, 113 patients meeting study criteria were biopsied at four centers using the new 9 gauge VAB device. The device has a radiofrequency-tipped probe, 360 degrees vacuum, a circumferential cutter, and a coaxial cannula for multiple sampling. Patient and procedural data included breast composition, lesion characteristics, number of samples, procedure time, and complications. Quality of samples, lesion access, and ergonomic features were assessed qualitatively and compared with prior experience with other biopsy devices. Immediate rebiopsy rate included high-risk lesions requiring surgical excision (obligate rebiopsy) and lesions requiring rebiopsy due to discordance or insufficient samples yielding nondiagnostic material. Data were analyzed using the Wilcoxon signed-rank test. One hundred thirteen patients aged 20-83 years (mean 52) were successfully biopsied with dense/fibrous breast tissue in 60% and dense/fibrous lesions in 49%. Lesions measured 6-63 mm (mean 17); 97% were masses. Five circumferential specimens (range 2-19) were obtained in 6 minutes (range 2-20). Operators rated safety and comfort comparable with existing devices and rated sample quality, breast/lesion penetration, and positioning ease/accuracy superior (p < 0.01). Diagnoses included 37 cancers, 70 benign, and six high-risk lesions with one upgrade from atypical ductal hyperplasia to ductal carcinoma in situ at surgery. Excluding obligate excision in high-risk diagnoses, the immediate rebiopsy rate was 2%. No complications required intervention. The new VAB device provides diagnostic samples and reduces sampling error defined by immediate rebiopsy rate. Compared with other devices, it is more ergonomic to target and position for sampling, particularly in dense breast tissue or lesions.


Asunto(s)
Biopsia/instrumentación , Neoplasias de la Mama/patología , Ultrasonografía Intervencional/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Biopsia/métodos , California , Ergonomía , Femenino , Humanos , Persona de Mediana Edad , Reoperación , Manejo de Especímenes , Ultrasonografía Intervencional/métodos
11.
Ann Surg Oncol ; 13(7): 967-76, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16788759

RESUMEN

BACKGROUND: The MammoSite device was designed as a breast brachytherapy applicator and is currently used to deliver accelerated partial breast irradiation (APBI). We hypothesized that APBI delivered with the MammoSite device would be well tolerated and be associated with a good cosmetic outcome in patients with ductal carcinoma-in-situ (DCIS). METHODS: From 2002 to 2004, 191 patients with DCIS were enrolled in a registry trial to assess the MammoSite applicator. Fifteen patients were excluded from analysis because of device- or patient-related factors; 7 patients were excluded after receiving a radiotherapy boost, thus leaving 169 patients available for study. Follow-up information was available for 158 patients. The average length of follow-up was 7.35 months. Forty-three patients had at least 1 year of follow-up. RESULTS: Skin spacing for the MammoSite applicator was as follows: < 5 mm, 3 patients (1.78%); 5 to 7 mm, 18 patients (10.65%); and > or = 7 mm, 148 patients (87.57%). Patients with a device-to-skin distance of > or = 7 mm had the best cosmetic result. Patients with a device-to-skin distance of > or = 7 mm also had a lower incidence of radiation dermatitis. Data on 43 patients who were followed up for at least 1 year confirmed these findings. Additional adverse events were primarily related to skin changes, with breast infections occurring in five patients (3.16%). No patient in the study has experienced a recurrence. CONCLUSIONS: APBI delivered via MammoSite is well tolerated in patients with DCIS, and the lowest toxicity was obtained in patients with the greatest device-to-skin distance. Long-term follow-up data regarding patient satisfaction, cosmesis, and efficacy are needed and will be determined from a recently opened large randomized study.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Carcinoma Intraductal no Infiltrante/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Braquiterapia/instrumentación , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/radioterapia , Carcinoma Ductal de Mama/cirugía , Carcinoma Intraductal no Infiltrante/cirugía , Carcinoma Lobular/radioterapia , Carcinoma Lobular/cirugía , Femenino , Humanos , Incidencia , Mastectomía/métodos , Persona de Mediana Edad , Recurrencia Local de Neoplasia/epidemiología , Estadificación de Neoplasias , Pronóstico , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
12.
Cancer ; 104(6): 1138-48, 2005 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16088962

RESUMEN

BACKGROUND: Eighty-seven institutions participated in a Registry Trial that was designed to collect data on the clinical use of the MammoSite breast brachytherapy catheter for delivering breast irradiation. Patient demographics, technical reproducibility, cosmesis, and early toxicity were evaluated. METHODS: From May 4, 2002 through July 30, 2004, 1419 patients with Stage 0, I, or II breast carcinoma who were undergoing breast-conserving therapy were enrolled on the trial. The device was placed in 1403 of these patients. The 1237 patients (87% of enrolled patients) who received accelerated partial breast irradiation (APBI) (34 grays prescribed to 1.0 cm in 10 fractions; 95% of patients who received APBI) constituted the study population; 86% of those patients (1068) had Stages I-II breast carcinoma (median tumor size, 10 mm), and 14% of those patients (169) had Stage 0 breast carcinoma. Ninety-one percent of the patients with invasive carcinoma (977 of 1068 patients) had negative lymph node status, and 99% of all patients had negative margins. The median patient age was 65 years. Systemic chemotherapy alone was administered to 79 patients with invasive carcinoma (7%), hormone therapy was administered to 501 patients (45%), and both were administered to 39 patients (4%). The median follow-up was 5 months. RESULTS: Five hundred fifty-four catheters (45%) were placed with an open cavity at the time of lumpectomy, and 683 catheters (55%) were placed with a closed cavity after lumpectomy. Skin spacing ranged from 2 mm to 75 mm (median, 10 mm). In 89% of patients, there was a minimum balloon-to-skin distance of 7 mm (2% of patients had distances < 5 mm). In terms of cosmetic assessment, 95% of patients (1030 of 1084 patients) who had a cosmetic assessment had a good/excellent result (last follow-up visit). Cosmetic results at 12 months were good/excellent in 92% of 248 evaluable patients. The median skin spacing (> or = 7 mm vs. < 7 mm) was associated significantly with a good/excellent cosmetic result (96.1% vs. 86.8%; P = 0.0001) overall and at 6 months (P = 0.006). Increasing skin spacing was associated with a good/excellent cosmetic result as a continuous variable (P < 0.0001). In total, 92 of 1140 evaluable patients (8.1%) developed an infection in the breast, which was device-related in 5.3% of patients (60 of 1140 patients). Good/excellent cosmetic results were noted in 86% of these patients (last follow-up visit). Fifteen of 442 evaluable patients (3.4%) developed a radiation recall reaction. Good/excellent cosmetic results were noted in 93% of these patients at their last follow-up visit. One local recurrence (0.1%) was reported (new primary carcinoma). CONCLUSIONS: Clinical evaluation of the ability of the MammoSite breast brachytherapy catheter to deliver APBI demonstrated acceptable technical reproducibility between multiple institutions and use in appropriate groups of patients. Cosmetic results at 12 months (92% good/excellent) were comparable to those reported with whole-breast RT. Early toxicity rates (infections, radiation recall) appeared to be acceptable.


Asunto(s)
Braquiterapia , Neoplasias de la Mama/radioterapia , Estética , Adulto , Anciano , Anciano de 80 o más Años , Braquiterapia/efectos adversos , Femenino , Humanos , Infecciones/etiología , Persona de Mediana Edad , Sistema de Registros , Reproducibilidad de los Resultados