Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Immunohematology ; 39(2): 55-60, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37405847

RESUMEN

The aim of this study was to define risk factors for jaundice and anemia in newborns with a positive direct antiglobulin test (DAT) and/or with an incompatible crossmatch due to ABO incompatibility between mother and newborn. ABO incompatibility has become a more significant cause of hemolytic disease of the fetus and newborn since the introduction of effective anti-D prophylaxis. The condition is common and, if clinically significant at all, causes only mild jaundice, which can be treated with phototherapy (PT). However, rare and serious presentations, requiring transfusion therapy, have been noted. Clinical, laboratory, and immunohematologic data were collected retrospectively from medical records of ABO-incompatible newborns and their mothers over a 5-year period (2016-2020) from University Hospital Centre Zagreb. Two groups of newborns were compared: those who needed medical intervention because of hyperbilirubinemia or anemia and those who did not. Within the group of newborns requiring intervention, we also compared those with A and B blood groups. Over the 5-year period, 72 of 184 (39%) newborns required treatment. The treatment was PT in 71 (38%) newborns and erythrocyte transfusion in 2 (1%). In 112 (61%) newborns, ABO incompatibility was an accidental finding while performing blood group typing; these newborns did not require any therapy. In conclusion, we found a statistical, but not clinically significant, difference between the groups of treated and untreated newborns, related to the mode of delivery and DAT positivity within hours of delivery. There were no statistically significant differences in characteristics between the groups of treated newborns, except for two newborns with blood group A who received erythrocyte transfusions.


Asunto(s)
Eritroblastosis Fetal , Madres , Femenino , Recién Nacido , Humanos , Estudios Retrospectivos , Incompatibilidad de Grupos Sanguíneos , Transfusión Sanguínea , Sistema del Grupo Sanguíneo ABO , Eritroblastosis Fetal/diagnóstico , Eritroblastosis Fetal/terapia
2.
Cell Tissue Bank ; 23(4): 807-824, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35129755

RESUMEN

The Croatian Cardiovascular Tissue Bank (CTB) was established in June 2011. Activities managed by CTB are processing of heart valves and blood vessels, as well as quality control, storage, medical release and distribution of allografts. The aim of this report is to present CTB's vascular tissue activities and retrospectively evaluate the outcomes of their use in the University Hospital Centre Zagreb. Between June 2011 and July 2021, 90 vascular allografts (VAs) from 55 donors after brain death were referred to CTB. Only 54% of VAs met the tissue quality requirements while 46% of tissues were discarded. The most frequent reasons for discard were unacceptable morphology and initial microbiological contamination. Altogether 42 VAs were released for transplantation and 37 of them were used in 27 surgical procedures. The most common indication for surgery was prosthetic graft or stent infection. According to the anatomic position of vascular reconstruction, patients were divided in the aortic and peripheral reconstruction group. A total of 23 patients were treated. In the aortic reconstruction group 58% of patients did not experience any graft-related complications. In the group of patients who underwent peripheral reconstruction significant incidence of reinfection was observed highlighting it as a major graft-related complication. Despite the small patient groups and limited duration of follow-up, presented clinical outcomes provide valuable information on the efficacy of vascular allografts. Additional clinical results collected on a larger patient groups and comparison to other reconstructive treatment options are necessary.


Asunto(s)
Prótesis Vascular , Infecciones Relacionadas con Prótesis , Humanos , Prótesis Vascular/efectos adversos , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Croacia/epidemiología , Bancos de Tejidos , Aloinjertos
3.
Immunohematology ; 37(1): 13-17, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33962487

RESUMEN

Many patients with anti-Yta receive multiple transfusions of Yt(a+) red blood cells (RBCs) with no ill effects. However, anti-Yta has been implicated in hemolytic transfusion reactions. Antibody identification typically determines specificity of antibodies and their clinical significance to justify blood requirements for antigen-negative blood when clinically significant antibodies are involved. Occasionally, specificity of antibody is of variable significance. Variability in clinical significance is a characteristic of anti-Yta that may affect the clinical management of such patients. This case reports the outcome of an incompatible transfusion in an 83-year-old female patient with anti-Yta, -D, -C, -Leab, and -HI who was admitted to the hospital for a severe urinary tract hemorrhage and fever. The patient was transfused with 1 crossmatch-incompatible group A, Yt(a+), D-, C-, E-, S- RBC unit in an emergency medical event. During that time, the patient exhibited chills, shivering, and tachycardia. Decreases in hemoglobin and hematocrit were noted. Laboratory parameters for hemolysis, such as total bilirubin, direct bilirubin, and lactate dehydrogenase, were increased. Based on clinical and laboratory evaluation, it was concluded that the patient had an acute hemolytic transfusion reaction caused by anti-Yta. The patient was successfully treated with antipyretics, antihistamines, and corticosteroids. Urinary tract hemorrhaging was stopped. Anemia was additionally improved with parenteral iron supplementation, and further transfusion was not required. Immunohematology 2021;37:13-17.Many patients with anti-Yta receive multiple transfusions of Yt(a+) red blood cells (RBCs) with no ill effects. However, anti-Yta has been implicated in hemolytic transfusion reactions. Antibody identification typically determines specificity of antibodies and their clinical significance to justify blood requirements for antigen-negative blood when clinically significant antibodies are involved. Occasionally, specificity of antibody is of variable significance. Variability in clinical significance is a characteristic of anti-Yta that may affect the clinical management of such patients. This case reports the outcome of an incompatible transfusion in an 83-year-old female patient with anti-Yta, -D, -C, -Leab, and -HI who was admitted to the hospital for a severe urinary tract hemorrhage and fever. The patient was transfused with 1 crossmatch-incompatible group A, Yt(a+), D­, C­, E­, S­ RBC unit in an emergency medical event. During that time, the patient exhibited chills, shivering, and tachycardia. Decreases in hemoglobin and hematocrit were noted. Laboratory parameters for hemolysis, such as total bilirubin, direct bilirubin, and lactate dehydrogenase, were increased. Based on clinical and laboratory evaluation, it was concluded that the patient had an acute hemolytic transfusion reaction caused by anti-Yta. The patient was successfully treated with antipyretics, antihistamines, and corticosteroids. Urinary tract hemorrhaging was stopped. Anemia was additionally improved with parenteral iron supplementation, and further transfusion was not required. Immunohematology 2021;37:13­17.


Asunto(s)
Isoanticuerpos , Reacción a la Transfusión , Anciano de 80 o más Años , Incompatibilidad de Grupos Sanguíneos , Tipificación y Pruebas Cruzadas Sanguíneas , Femenino , Hemólisis , Humanos
4.
Transfus Clin Biol ; 29(1): 37-43, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34411746

RESUMEN

BACKGROUND: Platelet transfusion practice varies widely since many aspects of platelet concentrate (PC) use have not been definitively determined. The objectives of this retrospective study were to present platelet transfusion practice and evaluate PC and patient characteristics, as well as their association with transfusion reaction (TR) rate. MATERIAL AND METHODS: Platelet transfusions over a 5-year period were analysed regarding PC characteristics (the ABO and RhD compatibility, product type, and storage duration), patient characteristics (most responsible diagnosis, age, and gender), and TR type. RESULTS: A total of 46,351 PCs were transfused: 76.4% whole blood-derived (WBD) and 23.6% single donor apheresis (SDA). Three thousand seven hundred seventy-six patients received platelet transfusions: 24.7% paediatric and 75.3% adult patients, 79.6% outpatients and 20.4% inpatients. As much as 63.1% of all transfused PCs were fresh (stored for≤3 days), 98.0% ABO-identical, and 87.3% of all PCs given to RhD- patients were RhD-. PCs were mainly transfused to haemato-oncology (76.8%) and cardiovascular surgery patients (6.5%). Overall, 84 (0.18%) TRs were reported, with allergic TRs (ATRs) being the most common. Although PC ABO compatibility and storage duration, as well as patient age and gender, showed differences in TR rate, only the use of PCs in platelet additive solution (PAS) showed a statistically significant reduction of TRs (P<0.001). CONCLUSION: Transfusion practice at the University Hospital Centre Zagreb resulted in almost all patients receiving ABO and RhD identical PCs, and most of them were fresh PCs. The most important factor affecting the incidence of TRs was platelet storage solution. The use of PAS effectively reduced the rate of TRs, particularly allergic TRs.


Asunto(s)
Transfusión de Plaquetas , Reacción a la Transfusión , Adulto , Plaquetas , Niño , Hospitales de Enseñanza , Humanos , Estudios Retrospectivos
6.
HLA ; 91(4): 299-300, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29457701

RESUMEN

The new allele HLA-B*18:37:02 differs from HLA-B*18:37:01 by one nucleotide substitutions in exon 2.


Asunto(s)
Alelos , Antígenos HLA-B/genética , Secuencia de Bases , Croacia , Exones/genética , Humanos , Alineación de Secuencia
7.
Biomed Pharmacother ; 52(9): 397-402, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9856287

RESUMEN

Thiorphan, a specific inhibitor of membrane neutral endopeptidase (NEP, EC 3.4.24.11) also known as the common acute lymphoblastic leukemia antigen (CALLA, CD10) was added into short-term clonal cultures of the buffy coat concentrates of human bone marrow obtained from a healthy donor (six experiments) and from ten patients with non-Hodgkin lymphoma (NHL) (eight in complete remission, one in partial remission and one in relapse). Thiorphan concentrations ranged from 10(-5) to 10(-13) M. Nanomolar and higher concentrations of the drug mildly stimulated the granulocyte-macrophage colony-forming unit (GM-CFU) counts in the cultures of normal bone marrow, reaching the significance at 10(-7) M. Meaningful alterations of the GM-CFU counts were noted in 31 of 79 thiorphan-treated cultures of NHL bone marrow (39%). In those cultures the stimulatory effects (33%) outnumbered the inhibitory ones (6%). The stimulatory effects occurred mainly in the bone marrow samples of the patients with highly malignant NHL. The observations are compatible with the idea that the membrane endopeptidase (CALLA, CD10) participates in processes controlling the proliferation and differentiation of hematopoetic cells by cleaving the neuropeptides and related hemoregulatory peptides.


Asunto(s)
Médula Ósea/efectos de los fármacos , Granulocitos/efectos de los fármacos , Linfoma no Hodgkin/patología , Macrófagos/efectos de los fármacos , Neprilisina/antagonistas & inhibidores , Inhibidores de Proteasas/farmacología , Tiorfan/farmacología , Médula Ósea/enzimología , Médula Ósea/patología , División Celular/efectos de los fármacos , Células Cultivadas , Ensayo de Unidades Formadoras de Colonias , Granulocitos/patología , Humanos , Linfoma no Hodgkin/enzimología , Macrófagos/patología
8.
Lijec Vjesn ; 113(3-4): 81-6, 1991.
Artículo en Croata | MEDLINE | ID: mdl-1890922

RESUMEN

During a 16-month period, blood for autologous transfusion treatment was taken in 186/788 (23.6%) orthopedic patients. Vasovagal reactions during blood withdrawal were observed in 8.6% of patients. Transfusiologic treatment with autologous blood alone was carried out in 134 (72%) patients. In 36 (19.4%) patients, homologous blood was given in addition to autologous blood. Withdrawal of the required blood unites could not be completed in 33 (17.7%) patients. In this group of patients, the need of homologous blood transfusion was highest (39.3%). In 98.3% of patients, mean values of hemoglobin and hematocrit immediately before the surgical procedure exceeded 100 g/L and 30%, respectively.


Asunto(s)
Transfusión de Sangre Autóloga , Ortopedia , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
9.
Haematologia (Budap) ; 30(4): 289-302, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11204028

RESUMEN

Thiorphan [(DL-3-mercapto-2-benzylpropanoyl)-glycine], a drug blocking the activity of membrane metalloendopeptidase EC 3.4.24.11 (CD10, CALLA), was added to long-term cultures of human bone marrow. Progression of the cultures was assessed by cell counts, cytology and clonogenic (GM-CFU) ability of the non-adherent cells in the supernatant and by morphology of the adherent stromal layer. A stimulatory effect on hematopoiesis was noted.


Asunto(s)
Células de la Médula Ósea/efectos de los fármacos , Células de la Médula Ósea/patología , Neprilisina/antagonistas & inhibidores , Inhibidores de Proteasas/farmacología , Tiorfan/farmacología , Diferenciación Celular/efectos de los fármacos , División Celular/efectos de los fármacos , Células Cultivadas , Humanos
10.
Transfus Med ; 14(3): 237-40, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15180816

RESUMEN

Bacterial contamination of blood products causes significant patient morbidity and mortality. Contaminated platelet transfusion is a frequent cause of bacteraemia and sepsis because of the storage conditions of platelets. A fatal case of Morganella morganii platelet transfusion associated with sepsis is described, along with procedures traced back to the isolation of M. morganii from a donor's stool. Molecular typing was performed, and the same M. morganii strain was found in blood and post-mortem organ cultures of platelet recipient and platelet bag and in the donor's stool. The route of contamination is unknown. The contamination could be due to either insufficient venipuncture site disinfection or the donor's transient bacteraemia. Patient died 5 days after the transfusion.


Asunto(s)
Infecciones por Enterobacteriaceae/transmisión , Morganella morganii/aislamiento & purificación , Transfusión de Plaquetas/efectos adversos , Sepsis/microbiología , Adulto , Técnicas de Tipificación Bacteriana , Donantes de Sangre , Infecciones por Enterobacteriaceae/diagnóstico , Resultado Fatal , Heces/microbiología , Femenino , Humanos , Leucemia Mieloide Aguda/complicaciones , Leucemia Mieloide Aguda/terapia , Masculino , Persona de Mediana Edad , Sepsis/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA