RESUMEN
Serum creatinine levels are insensitive to real-time changes in kidney function or injury. There is a growing interest in assessing kidney injury by measuring biomarkers in body fluid. From our previous studies, we identified and reported three urinary biomarkers namely Uromodulin (UMOD), Osteopontin (OPN), and Interleukin-9 (IL-9) to be associated with kidney health. The availability of a rapid point-of-care test for these urinary biomarkers will potentially accelerate its applicability and accessibility. In this study, we aimed to develop novel lateral flow device (LFD) for UMOD, OPN and IL-9. We tested paired antibodies using Enzyme Linked Immunosorbent Assay wherein we observed functionality only for UMOD and OPN and not for IL-9. A conjugation buffer pH of 7.8 and 8.5 was found suitable at a detection antibody concentration of 15 µg/mL for LFD development. The developed LFDs were found to quantitatively measure UMOD standard (LLOD of 80,000 pg/mL) and OPN standard (LLOD of 8600 pg/mL) respectively. The LFD was also able to measure human urinary UMOD and OPN with a percent CV of 12.12 and 5.23 respectively.
Asunto(s)
Interleucina-9 , Sistema Urinario , Humanos , Riñón , Anticuerpos , Biomarcadores , UromodulinaRESUMEN
We undertook a Phase 4 clinical trial to assess the effect of time interval between booster doses on serological responses to AVP. The primary objective was to evaluate responses to a single booster dose in two groups of healthy adults who had previously received a complete 4-dose primary course. Group A had received doses on schedule while Group B had not had one for ≥2 years. Secondary objectives were to evaluate the safety and tolerability of AVP booster doses, and to gain information on correlates of protection to aid future anthrax vaccine development. Blood samples were taken on Day 1 before dosing, and on Days 8, 15, 29 and 120, to measure Toxin Neutralisation Assay (TNA) NF50 values and concentrations of IgG antibodies against Protective Antigen (PA), Lethal Factor (LF) and Edema Factor (EF) by ELISA. For each serological parameter, fold changes from baseline following the trial AVP dose were greater in Group B than Group A at every time-point studied. Peak responses correlated positively with time since last AVP dose (highest values being observed after intervals of ≥10 years), and negatively with number of previous doses (highest values occurring in individuals who had received a primary course only). In 2017, having reviewed these results, the Joint Committee on Vaccination and Immunisation (JCVI) updated UK anthrax vaccination guidelines, extending the interval between routine AVP boosters from one to 10 years. Booster doses of AVP induce significant IgG responses against the three anthrax toxin components, particularly PA and LF. Similarly high responses were observed in TNA, a recognised surrogate for anthrax vaccine efficacy. Analysis of the 596 TNA results showed that anti-PA and anti-LF IgG make substantial independent contributions to neutralisation of anthrax lethal toxin. AVP may therefore have advantages over anthrax vaccines that depend on generating immunity to PA alone.