Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Ann Biomed Eng ; 52(6): 1779-1794, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38530534

RESUMEN

Tibiofemoral slip velocity is a key contributor to total knee arthroplasty (TKA) component wear, yet few studies have evaluated this quantity in vivo. The aim of the present study was to measure and compare tibiofemoral slip velocities in 3 TKA designs for a range of daily activities. Mobile biplane X-ray imaging was used to measure 6-degree-of-freedom tibiofemoral kinematics and the locations of articular contact in 75 patients implanted with a posterior-stabilized, cruciate-retaining, or medial-stabilized design while each patient performed level walking, step up, step down, sit-to-stand, and stand-to-sit. Using these data, tibiofemoral slip velocity was calculated for the duration of each activity for each TKA design. The pattern of tibiofemoral slip velocity was similar for all 3 TKA designs within each activity but markedly different across the 5 activities tested, with the magnitude of peak slip velocity being significantly higher in level walking (range: 158-211 mm/s) than in all other activities (range: 43-75 mm/s). The pattern of tibiofemoral slip velocity in both the medial and lateral compartments closely resembled the pattern of tibiofemoral (knee) flexion angular velocity, with a strong linear relationship observed between slip velocity and flexion angular velocity (r = 0.81-0.97). Tibiofemoral slip velocity was invariant to TKA design but was significantly affected by activity type. Our measurements of slip velocity and articular contact locations for a wide range of daily activities may be used as inputs in joint simulator testing protocols and computational models developed to estimate TKA component wear.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fémur , Humanos , Femenino , Masculino , Anciano , Fémur/diagnóstico por imagen , Fémur/fisiología , Fémur/cirugía , Persona de Mediana Edad , Prótesis de la Rodilla , Tibia/diagnóstico por imagen , Tibia/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Diseño de Prótesis , Fenómenos Biomecánicos , Anciano de 80 o más Años
2.
Ann Biomed Eng ; 51(3): 493-505, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36085332

RESUMEN

Six kinematic parameters are needed to fully describe three-dimensional (3D) bone motion at a joint. At the knee, the relative movements of the femur and tibia are often represented by a 1-degree-of-freedom (1-DOF) model with a single flexion-extension axis or a 2-DOF model comprising a flexion-extension axis and an internal-external rotation axis. The primary aim of this study was to determine the accuracy with which 1-DOF and 2-DOF models predict the 3D movements of the femur, tibia and patella during daily activities. Each model was created by fitting polynomial functions to 3D tibiofemoral (TF) and patellofemoral (PF) kinematic data recorded from 10 healthy individuals performing 6 functional activities. Model cross-validation analyses showed that the 2-DOF model predicted 3D knee kinematics more accurately than the 1-DOF model. At the TF joint, mean root-mean-square (RMS) errors across all activities and all participants were 3.4°|mm (deg or mm) for the 1-DOF model and 2.4°|mm for the 2-DOF model. At the PF joint, mean RMS errors were 4.0°|mm and 3.9°|mm for the 1-DOF and 2-DOF models, respectively. These results indicate that a 2-DOF model with two rotations as inputs may be used with confidence to predict the full 3D motion of the knee-joint complex.


Asunto(s)
Articulación Patelofemoral , Humanos , Rango del Movimiento Articular , Articulación de la Rodilla , Rodilla , Fémur , Tibia , Fenómenos Biomecánicos
3.
J Orthop Res ; 41(6): 1217-1227, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36317847

RESUMEN

The aim of this randomized controlled trial was to measure and compare six-degree-of-freedom (6-DOF) knee joint motion of three total knee arthroplasty (TKA) implant designs across a range of daily activities. Seventy-five TKA patients were recruited to this study and randomly assigned a posterior-stabilized (PS), cruciate-retaining (CR), or medial-stabilized (MS) implant. Six months after surgery, patients performed five activities of daily living: level walking, step-up, step-down, sit-to-stand, and stand-to-sit. Mobile biplane X-ray imaging was used to measure 6-DOF knee kinematics and the center of rotation of the knee in the transverse plane for each activity. Mean 6-DOF knee kinematics were consistently similar for PS and CR, whereas MS was more externally rotated and abducted, and lateral shift was lower across all activities. Peak-to-peak anterior drawer for MS was also significantly lower during walking, step-up, and step-down (p < 0.017). The center of rotation of the knee in the transverse plane was located on the medial side for MS, whereas PS and CR rotated about the lateral compartment or close to the tibial origin. The kinematic function of MS was more similar to that of the healthy knee than PS and CR based on reduced paradoxical anterior translation at low flexion angles and a transverse center of rotation located in the medial compartment. Overall, 6-DOF knee joint motion for PS and CR were similar across all daily activities, whereas that measured for MS was appreciably different. The kinematic patterns observed for MS reflects a highly conforming medial articulation in the MS design.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Fenómenos Biomecánicos , Actividades Cotidianas , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Rango del Movimiento Articular
4.
J Orthop Res ; 40(8): 1756-1769, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34878691

RESUMEN

We combined mobile biplane X-ray imaging and magnetic resonance imaging to measure the regions of articular cartilage contact and cartilage thickness at the tibiofemoral and patellofemoral joints during six functional activities: standing, level walking, downhill walking, stair ascent, stair descent, and open-chain (non-weight-bearing) knee flexion. The contact centers traced similar paths on the medial and lateral femoral condyles, femoral trochlea, and patellar facet in all activities while their locations on the tibial plateau were more varied. The translations of the contact centers on the femur and patella were tightly coupled to the tibiofemoral flexion angle in all activities (r2 > 0.95) whereas those on the tibia were only moderately related to the flexion angle (r2 > 0.62). The regions of contacting cartilage were significantly thicker than the regions of non-contacting cartilage on the patella, femoral trochlea, and the medial and lateral tibial plateaus in all activities (p < 0.001). There were no significant differences in thickness between contacting and non-contacting cartilage on the medial and lateral femoral condyles in all activities, except open-chain knee flexion. Our results provide partial support for the proposition that cartilage thickness is adapted to joint load and do not exclude the possibility that other factors, such as joint congruence, also play a role in regulating the structure and organization of healthy cartilage. The data obtained in this study may serve as a guide when evaluating articular contact motion in osteoarthritic and reconstructed knees.


Asunto(s)
Cartílago Articular , Articulación de la Rodilla , Fenómenos Biomecánicos , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/fisiología , Fémur/diagnóstico por imagen , Fémur/fisiología , Humanos , Rodilla , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiología , Imagen por Resonancia Magnética , Rótula/fisiología , Rango del Movimiento Articular/fisiología , Tibia/diagnóstico por imagen
5.
Gait Posture ; 98: 330-336, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36274470

RESUMEN

BACKGROUND: The ability of the quadriceps muscles to extend the knee depends on the moment arm of the knee-extensor mechanism, which is described by the moment arm of the patellar tendon at the knee. The knee-extensor moment may be altered by a change in quadriceps force, a change in the patellar tendon moment arm (PTMA), or both. A change in quadriceps muscle strength after anterior-cruciate-ligament-reconstruction (ACLR) surgery is well documented, however, there is limited knowledge about how this procedure affects the PTMA. RESEARCH QUESTION: Does ACLR surgery alter the moment arm of the knee-extensor mechanism during gait? METHODS: We measured the PTMA in both the ACLR knee and the uninjured contralateral knee in 10 young active individuals after unilateral ACLR surgery. Mobile biplane X-ray imaging was used to measure the three-dimensional positions of the femur, tibia and patella during level walking and downhill walking over ground. The PTMA was found from the location of the instantaneous axis of rotation at the knee and the line-of-action of the patellar tendon. RESULTS: There was a small but statistically significant difference in the mean PTMA calculated over one cycle of level walking between the ACLR knee and the contralateral knee, with the mean PTMA in the ACLR knee being 1.5 mm larger (p < 0.01). In downhill walking, statistically significant differences were found in the range 15°- 25° of knee flexion, where the PTMA was 4.7 mm larger in the ACLR knee compared to the contralateral knee (p < 0.01). SIGNIFICANCE: Significant differences were evident in the mean PTMA between the ACLR knee and the contralateral knee in both activities, however, the magnitudes of these differences were relatively small (range: 3-10%), indicating that ACLR surgery successfully restores the moment arm of the knee-extensor mechanism during dynamic activity.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Ligamento Rotuliano , Humanos , Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Articulación de la Rodilla/fisiología , Marcha/fisiología , Ligamento Rotuliano/cirugía , Fenómenos Biomecánicos
6.
J Biomech ; 123: 110484, 2021 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-34062347

RESUMEN

We measured the moment arm of the knee-extensor mechanism as ten healthy young individuals performed six functional activities: level walking, downhill walking, stair ascent, stair descent, open-chain (non-weight-bearing) knee flexion, and open-chain knee extension. The moment arm of the knee-extensor mechanism was described by the moment arm of the patellar-tendon force, which acts to rotate the tibia about the instantaneous axis of rotation (screw axis) of the knee. A mobile biplane X-ray imaging system enabled simultaneous measurements of the three-dimensional movements of the femur, tibia and patella during each activity, from which the position and orientation of the screw axis and the patellar-tendon moment arm (PTMA) were determined. Mean PTMA across all activities and all participants remained nearly constant (~46 mm) from 0° to 70° of knee flexion and decreased by no more than 20% at higher flexion angles. The magnitude of the PTMA varied more substantially across individuals than across activities, indicating that the moment arm is more heavily influenced by differences in knee-joint geometry than muscle loading. Hence, PTMA measurements obtained for a given activity performed by one individual may be used with good confidence to describe the PTMA for any other activity performed by the same individual. Caution is advised when using PTMA measurements obtained from one individual to describe the moment arm in another individual even once the data are normalized by knee bone size, as the PTMA varied by as much as 13% from the mean across individuals.


Asunto(s)
Rótula , Ligamento Rotuliano , Fenómenos Biomecánicos , Fémur , Humanos , Articulación de la Rodilla , Rango del Movimiento Articular
7.
Ann Biomed Eng ; 49(4): 1183-1198, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33094419

RESUMEN

The purpose of this study was to measure the three-dimensional movements of the femur, tibia and patella in healthy young people during activities of daily living. A mobile biplane X-ray imaging system was used to obtain simultaneous measurements of six-degree-of-freedom (6-DOF) tibiofemoral and patellofemoral kinematics and femoral condylar motion in ten participants during standing, level walking, downhill walking, stair ascent, stair descent and open-chain (non-weightbearing) knee flexion. Seven of the eleven secondary motions at the knee-three translations at the tibiofemoral joint, three translations at the patellofemoral joint, and patellar flexion-were coupled to the tibiofemoral flexion angle (r2 ≥ 0.71). Tibial internal-external rotation, tibial abduction-adduction, patellar rotation, and patellar tilt were each weakly related to the tibiofemoral flexion angle (r2 ≤ 0.45). The displacements of the femoral condyles were also coupled to the tibiofemoral flexion angle (r2 ≥ 0.70), with the lateral condyle translating further on the tibial plateau than the medial condyle. The center of rotation of the tibiofemoral joint in the transverse plane was located on the medial side in all activities. These findings expand our understanding of the kinematic function of the healthy knee and may be relevant to a range of applications in biomechanics, including the design of prosthetic knee implants and the development of knee models for use in full-body simulations of movement.


Asunto(s)
Actividades Cotidianas , Articulación de la Rodilla/fisiología , Adulto , Fenómenos Biomecánicos , Femenino , Fémur/fisiología , Humanos , Masculino , Rótula/fisiología , Posición de Pie , Tibia/fisiología , Caminata/fisiología , Adulto Joven
8.
J Orthop Res ; 38(8): 1753-1768, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31994751

RESUMEN

Accurate knowledge of knee joint motion is needed to evaluate the effects of implant design on functional performance and component wear. We conducted a randomized controlled trial to measure and compare 6-degree-of-freedom (6-DOF) kinematics and femoral condylar motion of posterior-stabilized (PS), cruciate-retaining (CR), and medial-stabilized (MS) knee implant designs for one cycle of walking. A mobile biplane X-ray imaging system was used to accurately measure 6-DOF tibiofemoral motion as patients implanted with PS (n = 23), CR (n = 25), or MS (n = 26) knees walked over ground at their self-selected speeds. Knee flexion angle did not differ significantly between the three designs. Relative movements of the femoral and tibial components were generally similar for PS and CR with significant differences observed only for anterior tibial drawer. Knee kinematic profiles measured for MS were appreciably different: external rotation and abduction of the tibia were increased while peak-to-peak anterior drawer was significantly reduced for MS compared with PS and CR. Anterior-posterior drawer and medial-lateral shift of the tibia were strongly coupled to internal-external rotation for MS, as was anterior-posterior translation of the contact center in the lateral compartment. MS exhibited the least amount of paradoxical anterior translation of the femur relative to the tibia during knee flexion. The joint center of rotation in the transverse plane was located in the lateral compartment for PS and CR and in the medial compartment for MS. Substantial differences were evident in 6-DOF knee kinematics between the healthy knee and all three prosthetic designs. Overall, knee kinematic profiles observed for MS resemble those of the healthy joint more closely than PS and CR.


Asunto(s)
Marcha , Articulación de la Rodilla , Prótesis de la Rodilla , Diseño de Prótesis , Femenino , Masculino , Fenómenos Biomecánicos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiología , Prótesis de la Rodilla/estadística & datos numéricos , Estudios Prospectivos , Diseño de Prótesis/estadística & datos numéricos , Radiografía , Humanos , Persona de Mediana Edad , Anciano
9.
J Orthop Res ; 37(3): 615-630, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30680795

RESUMEN

Accurate knowledge of knee kinematics is important for a better understanding of normal joint function and for improving patient outcomes subsequent to joint reconstructive surgery. Limited information is available that accurately describes the relative movements of the bones at the knee in vivo, even for the most common of all activities: walking. We used a mobile X-ray imaging system to measure the three-dimensional motion of the entire knee-joint complex-femur, tibia, and patella-when humans walk over ground at their natural speeds. Data were recorded from 15 healthy individuals (9 males, 6 females; age 30.5 ± 6.2 years). The most pronounced rotational motion of the tibia was flexion-extension followed by internal-external rotation and abduction-adduction (peak-to-peak displacements: 70.7°, 9.2°, and 1.9°, respectively). Maximum anterior translation of the tibia was 6.5 mm and occurred in early swing, coinciding with peak knee flexion and peak internal rotation. The most prominent rotational motion of the patella was flexion-extension (peak-to-peak displacement: 50.5°). The tibia pivoted about the medial compartment of the tibiofemoral joint, conferring greater movements of the contact centers in the lateral compartment than the medial compartment (15.4 and 9.7 mm, respectively). Internal-external rotation, anterior-posterior translation and medial-lateral shift of the tibia as well as flexion-extension and anterior-posterior translation of the patella were each coupled to the knee flexion angle, as were movements of the contact centers at each joint. These fundamental data serve as a valuable resource for evaluating knee joint function in normal and pathological gait. The data are available in Supplementary_Material_Data.xlsx. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Asunto(s)
Articulación de la Rodilla/fisiología , Caminata/fisiología , Adulto , Fenómenos Biomecánicos , Estudios Transversales , Femenino , Fémur/fisiología , Humanos , Imagenología Tridimensional , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Rótula/fisiología , Radiografía , Tibia/fisiología , Adulto Joven
10.
J Biomech ; 57: 152-156, 2017 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-28454908

RESUMEN

The aim of this study was to evaluate the accuracy with which mobile biplane X-ray imaging can be used to measure patellofemoral kinematics of the intact knee during overground gait. A unique mobile X-ray imaging system tracked and recorded biplane fluoroscopic images of two human cadaver knees during simulated overground walking at a speed of 0.7m/s. Six-degree-of-freedom patellofemoral kinematics were calculated using a bone volumetric model-based method and the results then compared against those derived from a gold-standard bead-based method. RMS errors for patellar anterior translation, superior translation and lateral shift were 0.19mm, 0.34mm and 0.37mm, respectively. RMS errors for patellar flexion, lateral tilt and lateral rotation were 1.08°, 1.15° and 1.46°, respectively. The maximum RMS error for patellofemoral translations was approximately one-half that reported previously for tibiofemoral translations using the same mobile X-ray imaging system while the maximum RMS error for patellofemoral rotations was nearly two times larger than corresponding errors reported for tibiofemoral rotations. The lower accuracy in measuring patellofemoral rotational motion is likely explained by the symmetric nature of the patellar geometry and the smaller size of the patella compared to the tibia.


Asunto(s)
Marcha/fisiología , Articulación de la Rodilla/fisiología , Adulto , Fenómenos Biomecánicos , Cadáver , Femenino , Fluoroscopía , Humanos , Persona de Mediana Edad , Rótula/fisiología , Radiografía , Rango del Movimiento Articular , Rotación , Tibia/fisiología
11.
J Orthop Res ; 35(8): 1634-1643, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27770609

RESUMEN

No data are available to describe six-degree-of-freedom (6-DOF) knee-joint kinematics for one complete cycle of overground walking following total knee arthroplasty (TKA). The aims of this study were firstly, to measure 6-DOF knee-joint kinematics and condylar motion for overground walking following TKA; and secondly, to determine whether such data differed between overground and treadmill gait when participants walked at the same speed during both tasks. A unique mobile biplane X-ray imaging system enabled accurate measurement of 6-DOF TKA knee kinematics during overground walking by simultaneously tracking and imaging the joint. The largest rotations occurred for flexion-extension and internal-external rotation whereas the largest translations were associated with joint distraction and anterior-posterior drawer. Strong associations were found between flexion-extension and adduction-abduction (R2 = 0.92), joint distraction (R2 = 1.00), and anterior-posterior translation (R2 = 0.77), providing evidence of kinematic coupling in the TKA knee. Although the measured kinematic profiles for overground walking were grossly similar to those for treadmill walking, several statistically significant differences were observed between the two conditions with respect to temporo-spatial parameters, 6-DOF knee-joint kinematics, and condylar contact locations and sliding. Thus, caution is advised when making recommendations regarding knee implant performance based on treadmill-measured knee-joint kinematic data. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1634-1643, 2017.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/fisiología , Caminata/psicología , Anciano , Fenómenos Biomecánicos , Femenino , Marcha , Humanos , Masculino , Persona de Mediana Edad
12.
IEEE Trans Med Imaging ; 35(1): 326-36, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26316030

RESUMEN

Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human body movement for high-speed imaging of 3D joint motion during overground gait. A robotic gantry mechanism translates the two X-ray units alongside the subject, tracking and imaging the joint of interest as the subject moves. The main aim of the present study was to determine the accuracy with which the mobile imaging system measures 3D knee-joint kinematics during walking. In vitro experiments were performed to measure the relative positions of the tibia and femur in an intact human cadaver knee and of the tibial and femoral components of a total knee arthroplasty (TKA) implant during simulated overground gait. Accuracy was determined by calculating mean, standard deviation and root-mean-squared errors from differences between kinematic measurements obtained using volumetric models of the bones and TKA components and reference measurements obtained from metal beads embedded in the bones. Measurement accuracy was enhanced by the ability to track and image the joint concurrently. Maximum root-mean-squared errors were 0.33 mm and 0.65° for translations and rotations of the TKA knee and 0.78 mm and 0.77° for translations and rotations of the intact knee, which are comparable to results reported for treadmill walking using stationary biplane systems. System capability for in vivo joint motion measurement was also demonstrated for overground gait.


Asunto(s)
Fluoroscopía/métodos , Marcha/fisiología , Imagenología Tridimensional/métodos , Articulación de la Rodilla/fisiología , Anciano , Algoritmos , Fenómenos Biomecánicos/fisiología , Femenino , Humanos , Modelos Biológicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA