Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Revista
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Heart ; 109(15): 1153-1158, 2023 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-37147129

RESUMEN

OBJECTIVES: To describe the aortic-related risks associated with pregnancy in women with bicuspid aortic valve (BAV) and to evaluate changes in aortic diameter in pregnancy. METHODS: Prospective observational study of patients with BAV from a single-site registry of pregnant women with structural heart disease between 2013 and 2020. Cardiac, obstetric and neonatal outcomes were studied. An assessment of aortic dimensions was performed during pregnancy by two-dimensional echocardiography. Aortic diameters were measured at the annulus, root, sinotubular junction and maximum ascending aorta diameter, and the largest diameter was used. Measurements of the aorta were made using the end-diastolic leading edge-to-leading edge convention. RESULTS: Forty-three women (32.9 years, IQR 29.6-35.3) with BAV were included: 9 (20.9%) had repaired aortic coarctation; 23 (53.5%) had moderate or severe aortic valve disease; 5 (11.6%) had a bioprosthetic aortic valve; and 2 (4.7%) had a mechanical prosthetic aortic valve. Twenty (47.0%) were nulliparous. The mean aortic diameter in the first trimester was 38.5 (SD 4.9) mm, and that in the third trimester was 38.4 (SD 4.8) mm. Forty (93.0%) women had an aortic diameter of <45 mm; 3 (7.0%) had 45-50 mm; and none had >50 mm. Three women (6.9%) with BAV presented cardiovascular complications during pregnancy or the postpartum period (two prosthetic thrombosis and one heart failure). No aortic complications were reported. There was a small but significant increase in aortic diameter during pregnancy (third trimester vs first trimester, 0.52 (SD 1.08) mm; p=0.03). Obstetric complications appeared in seven (16.3%) of pregnancies, and there were no maternal deaths. Vaginal non-instrumental delivery was performed in 21 (51.2%) out of 41 cases. There were no neonatal deaths, and the mean newborn weight was 3130 g (95% CI 2652 to 3380). CONCLUSIONS: Pregnancy in BAV women had a low rate of cardiac complications with no aortic complications observed in a small study group. Neither aortic dissection nor need for aortic surgery was reported. A low but significant aortic growth was observed during pregnancy. Although requiring follow-up, the risk of aortic complications in pregnant women with BAV and aortic diameters of <45 mm at baseline is low.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Embarazo , Recién Nacido , Humanos , Femenino , Masculino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos
2.
Heart ; 105(8): 603-608, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30322846

RESUMEN

OBJECTIVE: Bicuspid aortic valve (BAV) is the most common congenital heart disease. This study aimed to determine the prevalence rate of BAV in first-degree relatives (FDR) and the inheritance pattern according to different morphotypes and aortic dilation. METHODS: BAV probands were consecutively studied at eight tertiary referral centres. After sequential screening, FDR were included in the study. The BAV morphotype, aortic dilation and aortic phenotype were assessed by transthoracic echocardiography. RESULTS: Seven hundred and twenty-four FDR of 256 BAV probands agreed to undergo family screening. The prevalence of BAV was 6.4% in FDR (9.2% in men, 3.5% in women, p=0.002). Aortic dilation was diagnosed in 9.6% of FRD with tricuspid aortic valves (TAV), with a root phenotype in 2.7% and tubular in 6.9% and more frequently in the presence of arterial hypertension (OR 4.48; CI 95% 2.51 to 7.99; p=0.0001) and valvular regurgitation (OR 5.87, CI 95% 1.37 to 25.16; p=0.025). The heritability (h2 ) of BAV was highly significant (0.47; p=0.002); however, no concordance was observed among valve morphotypes. Aortic dilation heritability was not significant. CONCLUSIONS: The BAV prevalence rate in FDR was low (6.4%) but aortic dilation was observed in 9.6% of FDR with TAV. The heritability of BAV was high without concordance in valve morphotypes, and aortic dilation heritability was not observed. Patients with BAV should be made aware of its familial pattern.


Asunto(s)
Aorta , Enfermedades de la Aorta , Válvula Aórtica/anomalías , Familia , Enfermedades de las Válvulas Cardíacas , Adulto , Aorta/anomalías , Aorta/diagnóstico por imagen , Aorta/patología , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/etiología , Enfermedades de la Aorta/fisiopatología , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Variación Biológica Poblacional , Análisis por Conglomerados , Dilatación Patológica/diagnóstico por imagen , Dilatación Patológica/etiología , Dilatación Patológica/fisiopatología , Ecocardiografía/métodos , Salud de la Familia/estadística & datos numéricos , Femenino , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/epidemiología , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Patrón de Herencia , Masculino , Persona de Mediana Edad , Linaje , Prevalencia , Análisis de Secuencia/métodos , España/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA