1.
J Magn Reson Imaging ; 44(6): 1456-1463, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27185221

RESUMEN

PURPOSE: To investigate the feasibility of high-sensitivity cellular MRI of embryonic stem (ES) cells using a novel cell permeable and cell retentive T1 contrast agent. MATERIALS AND METHODS: Mouse ES cells were labeled with a novel manganese porphyrin contrast agent, MnAMP, at 0.1 mM over 2 to 24 h and retained in contrast-free medium for up to 24 h postlabeling. MRI was performed on a 3 Tesla clinical scanner; T1 and T2 relaxation times were measured. Quantification of manganese content was performed using atomic absorption spectroscopy. Viability and proliferation assays were done for the longest labeling interval. Differentiation capacity was assessed using the hanging drop method to direct differentiation toward cardiomyocytes. RESULTS: MnAMP-labeled ES cells exhibited over a fourfold decrease in T1 compared with unlabeled cells, and maintained up to a threefold decrease 24 h postlabeling. Viability and proliferation were not affected. Most importantly, labeled ES cells differentiated into functional cardiomyocytes that exhibited normal contractility patterns. CONCLUSION: MnAMP-based cellular MRI is a very high sensitivity T1 approach for cellular imaging. It has the potential for noninvasive in vivo monitoring of stem cell therapy in cardiac regeneration and other tissue engineering and regenerative medicine applications. J. Magn. Reson. Imaging 2016;44:1456-1463.


Asunto(s)
Rastreo Celular/métodos , Células Madre Embrionarias/citología , Células Madre Embrionarias/trasplante , Imagen por Resonancia Magnética/métodos , Manganeso/química , Miocitos Cardíacos/citología , Porfirinas/química , Animales , Diferenciación Celular , Línea Celular , Medios de Contraste/química , Estudios de Factibilidad , Regeneración Tisular Dirigida/métodos , Ratones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
J Magn Reson Imaging ; 41(2): 397-403, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24399613

RESUMEN

PURPOSE: To evaluate a new formulation of manganese porphyrin as a potential gadolinium (Gd)-free extracellular magnetic resonance imaging (MRI) contrast agent for dynamic contrast-enhanced (DCE) MRI of tumors. MATERIALS AND METHODS: A previously reported new contrast agent, MnTCP, was evaluated in six female tumor-bearing nude rats. MRI was performed on a 3 T clinical scanner 3 to 4 weeks after inoculation of breast tumor cells in the mammary fat pads. Gd-DTPA was injected intravenously, followed by injection of MnTCP at least 2 hours later (both at 0.05 mmol/kg). T1 relaxation time measurements and DCE-MRI were performed. RESULTS: Enhancement and clearance patterns were visually similar between MnTCP and Gd-DTPA. However, relative R1 increases in all 11 tumors were larger for MnTCP over 60 minutes postcontrast, the difference being significant as late as 20 minutes (R1post /R1pre = 1.42 ± 0.15 for MnTCP vs. 1.20 ± 0.08 for Gd-DTPA, P < 0.05). R1 -related effects for MnTCP were largely reduced after 60 minutes (R1post /R1pre = 1.13 ± 0.07) and completely gone within 24 hours (R1post /R1pre = 0.97 ± 0.06). DCE-MRI revealed a consistently larger (1.5 to over 2-fold) peak enhancement and higher values of the steepest slope, time-to-peak, and AUC60 in all tumors with MnTCP (P < 0.01). CONCLUSION: MnTCP is an alternative to extracellular Gd agents for tumor imaging, offering sensitive detection and rapid renal clearance.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias Mamarias Experimentales/patología , Manganeso , Porfirinas , Animales , Femenino , Gadolinio DTPA , Ratas , Ratas Desnudas
3.
Mol Imaging ; 132014.
Artículo en Inglés | MEDLINE | ID: mdl-25248390

RESUMEN

The lung remains one of the most challenging organs to image using magnetic resonance imaging (MRI) due to intrinsic rapid signal decay. However, unlike conventional modalities such as computed tomography, MRI does not involve radiation and can provide functional and morphologic information on a regional basis. Here we demonstrate proof of concept for a new MRI approach to achieve substantial gains in a signal to noise ratio (SNR) in the lung parenchyma: contrast-enhanced ultrashort echo time (UTE) imaging following intravenous injection of a high-relaxivity blood-pool manganese porphyrin T1 contrast agent. The new contrast agent increased relative enhancement of the lung parenchyma by over 10-fold compared to gadolinium diethylene triamine pentaacetic acid (Gd-DTPA), and the use of UTE boosted the SNR by a factor of 4 over conventional T1-weighted gradient echo acquisitions. The new agent also maintains steady enhancement over at least 60 minutes, thus providing a long time window for obtaining high-resolution, high-quality images and the ability to measure a number of physiologic parameters.


Asunto(s)
Compuestos de Bifenilo , Medios de Contraste , Pulmón/ultraestructura , Metaloporfirinas , Animales , Femenino , Imagen por Resonancia Magnética/métodos , Ratas , Ratas Long-Evans
4.
J Magn Reson Imaging ; 40(6): 1474-80, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24214904

RESUMEN

PURPOSE: To evaluate a new class of manganese porphyrins with tunable pharmacokinetics as potential gadolinium (Gd)-free T1 agents for contrast-enhanced magnetic resonance imaging (MRI). MATERIALS AND METHODS: Two new contrast agents, MnTCP and MnP2, were evaluated in four female rats. MRI was performed daily up to 3 days postinjection (0.05 mmol/kg) on a 3 T clinical scanner. T1 relaxation times and dynamic contrast-enhanced MRI were performed to assess contrast enhancement and clearance in blood, heart, liver, kidney, and muscle. RESULTS: Relative T1 decreases were similar for MnTCP and Gd-DTPA in all tissues but were significantly larger (P < 0.05) for MnP2 in blood, heart, kidney, and liver (2-6-fold larger). Clearance of MnTCP was similar to Gd-DTPA, with T1 returning to baseline by 40 minutes and complete elimination in 1 day. MnP2 was cleared from blood after 2 days and sustained a lowered T1 in other tissues for at least 1 hour (P < 0.05). The maximum enhancement, slope, and time-to-peak were similar between contrast agents. Only the parameter AUC60 differed, with MnP2 yielding the largest AUC60 values primarily through longer retention in tissue. CONCLUSION: MnTCP and MnP2 offer distinct applications as Gd-free T1 contrast agents. MnTCP behaves like a Gd-DTPA analog, while MnP2 provides significantly greater and longer positive signal enhancement.


Asunto(s)
Compuestos de Magnesio/farmacocinética , Imagen por Resonancia Magnética/métodos , Porfirinas/farmacocinética , Imagen de Cuerpo Entero/métodos , Animales , Medios de Contraste/farmacocinética , Femenino , Tasa de Depuración Metabólica , Especificidad de Órganos/fisiología , Ratas , Ratas Long-Evans , Distribución Tisular
5.
Contrast Media Mol Imaging ; 2019: 3475786, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31316306

RESUMEN

Noninvasive cell tracking in vivo has the potential to advance stem cell-based therapies into the clinic. Magnetic resonance imaging (MRI) provides an excellent image-guidance platform; however, existing MR cell labeling agents are fraught with limited specificity. To address this unmet need, we developed a highly efficient manganese porphyrin contrast agent, MnEtP, using a two-step synthesis. In vitro MRI at 3 Tesla on human embryonic stem cells (hESCs) demonstrated high labeling efficiency at a very low dose of 10 µM MnEtP, resulting in a four-fold lower T 1 relaxation time. This extraordinarily low dose is ideal for labeling large cell numbers required for large animals and humans. Cell viability and differentiation capacity were unaffected. Cellular manganese quantification corroborated MRI findings, and the agent localized primarily on the cell membrane. In vivo MRI of transplanted hESCs in a rat demonstrated excellent sensitivity and specificity of MnEtP for noninvasive stem cell tracking.


Asunto(s)
Rastreo Celular/métodos , Medios de Contraste/química , Células Madre Embrionarias Humanas/citología , Imagen por Resonancia Magnética/métodos , Animales , Medios de Contraste/síntesis química , Humanos , Manganeso , Porfirinas , Ratas
6.
Sci Rep ; 8(1): 12129, 2018 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-30108285

RESUMEN

MRI for non-invasive cell tracking is recognized for enabling pre-clinical research on stem cell therapy. Yet, adoption of cellular imaging in stem cell research has been restricted to sites with experience in MR contrast agent synthesis and to small animal models that do not require scaled-up synthesis. In this study, we demonstrate the use of a gadolinium-free T1 contrast agent for tracking human embryonic stem cells. The agent, MnPNH2, is an easily synthesized manganese porphyrin that can be scaled for large cell numbers. MRI was performed on a 3 T clinical scanner. Cell pellets labeled at different MnPNH2 concentrations for 24 hours demonstrated a decrease in T1 relaxation time of nearly two-fold (P < 0.05), and cellular contrast was maintained for 24 hours (P < 0.05). Cell viability (Trypan blue) and differentiation (embryoid body formation) were unaffected. Cell uptake of Mn on inductively coupled plasma atomic emission spectroscopy corroborated MRI findings, and fluorescence microscopy revealed the agent localized mainly in cell-cell boundaries and cell nuclei. Labeled cells transplanted in rats demonstrated the superior sensitivity of MnPNH2 for in-vivo cell tracking.


Asunto(s)
Rastreo Celular/métodos , Medios de Contraste/administración & dosificación , Células Madre Embrionarias Humanas/trasplante , Imagen por Resonancia Magnética/métodos , Animales , Técnicas de Cultivo de Célula , Diferenciación Celular , Núcleo Celular/química , Supervivencia Celular , Medios de Contraste/síntesis química , Femenino , Células Madre Embrionarias Humanas/química , Humanos , Microscopía Intravital/métodos , Manganeso/química , Microscopía Fluorescente , Modelos Animales , Porfirinas/química , Ratas , Ratas Sprague-Dawley , Sensibilidad y Especificidad , Espectrofotometría Atómica
7.
Chem Sci ; 7(7): 4308-4317, 2016 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30155077

RESUMEN

Magnetic resonance imaging (MRI) is a preferred technique for noninvasively monitoring the fate of implanted cells, such as stem cells and immune cells in vivo. Cellular MRI requires contrast agents (CAs) to label the cells of interest. Despite promising progress made in this emerging field, highly sensitive, stable and biocompatible T1 CAs with high cell permeability and specificity remains an unmet challenge. To address this need, a novel MnIII-porphyrin, MnAMP was designed and synthesized based on the modification of MnIIItetra(carboxy-porphyrin) (MnTCP), a small and highly stable non-Gd extracellular CA with good biocompatibility and high T1 relaxivity (r1 = 7.9 mM-1 s-1) at clinical field of 3 Tesla (T). Cell permeability was achieved by masking the polar carboxylates of MnTCP with acetoxymethyl-ester (AM) groups, which are susceptible to hydrolysis by intracellular esterases. The enzymatic cleavage of AM groups led to disaggregation of the hydrophobic MnAMP, releasing activated MnTCP with significant increase in T1 relaxivity. Cell uptake of MnAMP is highly efficient as tested on two non-phagocytic human cell lines with no side effects observed on cell viability. MRI of labeled cells exhibited significant contrast enhancement with a short T1 of 161 ms at 3 T, even though a relatively low concentration of MnAMP and short incubation time was applied for cell labeling. Overall, MnAMP is among the most efficient T1 cell labeling agents developed for cellular MRI.

8.
J Med Chem ; 57(2): 516-20, 2014 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-24328058

RESUMEN

Mn(III) porphyrin (MnP) holds the promise of addressing the emerging challenges associated with Gd-based clinical MRI contrast agents (CAs), namely, Gd-related adverse effect and decreasing sensitivity at high clinical magnetic fields. Two complementary strategies for developing new MnPs as Gd-free CAs with optimized biocompatibility were established to improve relaxivity or clearance rate. MnPs with distinct and tunable pharmacokinetic properties can consequently be constructed for different in vivo applications at clinical field of 3 T.


Asunto(s)
Compuestos de Bifenilo/síntesis química , Medios de Contraste/síntesis química , Complejos de Coordinación/síntesis química , Manganeso , Metaloporfirinas/síntesis química , Porfirinas/síntesis química , Animales , Compuestos de Bifenilo/química , Compuestos de Bifenilo/farmacocinética , Medios de Contraste/química , Medios de Contraste/farmacocinética , Complejos de Coordinación/química , Complejos de Coordinación/farmacocinética , Gadolinio , Imagen por Resonancia Magnética , Metaloporfirinas/química , Metaloporfirinas/farmacocinética , Porfirinas/química , Porfirinas/farmacocinética , Ratas , Relación Estructura-Actividad
9.
J Am Chem Soc ; 128(16): 5312-3, 2006 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-16620081

RESUMEN

The first examples of a tandem Nazarov cyclization/Michael addition process are described. The sequence is efficiently catalyzed by Ir[Me(CO)(dppe)(DIB)]2+ and occurs with high diastereoselectivity, creating three contiguous stereocenters. The mechanistic factors controlling the reactivity and diastereoselectivity are discussed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA