Ear Hear ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38915137

RESUMEN

OBJECTIVES: A wide variety of intraoperative tests are available in cochlear implantation. However, no consensus exists on which tests constitute the minimum necessary battery. We assembled an international panel of clinical experts to develop, refine, and vote upon a set of core consensus statements. DESIGN: A literature review was used to identify intraoperative tests currently used in the field and draft a set of provisional statements. For statement evaluation and refinement, we used a modified Delphi consensus panel structure. Multiple interactive rounds of voting, evaluation, and feedback were conducted to achieve convergence. RESULTS: Twenty-nine provisional statements were included in the original draft. In the first voting round, consensus was reached on 15 statements. Of the 14 statements that did not reach consensus, 12 were revised based on feedback provided by the expert practitioners, and 2 were eliminated. In the second voting round, 10 of the 12 revised statements reached a consensus. The two statements which did not achieve consensus were further revised and subjected to a third voting round. However, both statements failed to achieve consensus in the third round. In addition, during the final revision, one more statement was decided to be deleted due to overlap with another modified statement. CONCLUSIONS: A final core set of 24 consensus statements was generated, covering wide areas of intraoperative testing during CI surgery. These statements may provide utility as evidence-based guidelines to improve quality and achieve uniformity of surgical practice.

2.
Sci Rep ; 14(1): 2645, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38302541

RESUMEN

Using anatomy-based fitting, we can determine the place-specific map with individualized center frequencies for each electrode contact that is a closer match to the natural pitch-place of the cochlea. The primary objective of this study is to evaluate the tonal presentation across the electrode array and to calculate the semitone difference between each adjacent pair of contacts according to their anatomy-based map. The secondary objective is to determine the distancing of the contacts that would result in an equal semitone difference with a uniform tonal presentation. A total of 167 ears were included in this retrospective study. The frequencies across the electrode arrays were found to be unequally presented. The semitonal condensations were higher in the apical inter-contact spaces compared to the basal inter-contact spaces, being 3.0-2.3 semitones/mm (Kruskal Wallis test, p < 0.000). The anatomy-based spacing of the electrode contacts was larger in the basal inter-contact spaces compared to the apical inter-contact spaces, ranging from 1.92 to 1.48 mm. In conclusion, the current electrode designs do not have uniform tonal representation throughout the electrode array. There is a more condensed tonal presentation in the apical electrodes than in the basal electrodes, resulting in a lower tonal resolution in the apical region.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Estudios Retrospectivos , Implantación Coclear/métodos , Cóclea , Electrodos Implantados , Cafeína
3.
Indian J Otolaryngol Head Neck Surg ; 76(2): 1848-1856, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38566745

RESUMEN

Myringoplasty is still the most performed otological surgery. Nevertheless, the underlay vs. overlay approaches have yet to be determined. The purpose of this study is to compare the surgical and audiological outcomes of underlay and overlay myringoplasty in perforated tympanic membrane patients. A systematic review and meta-analysis synthesizing randomized controlled trials (RCTs), which were retrieved by systematically searching of Web of Science, SCOPUS, PubMed, and Google Scholar until January 25th, 2023. RevMan version 5.4 software was used to pooled dichotomous outcomes using the risk ratio (RR) with the corresponding 95% confidence interval (CI). We registered our protocol in PROSPERO with ID: [CRD42023387432]. We included eight RCTs with 656 tympanic perforation membrane patients. Four RCTs had a low risk of overall bias, two had some concerns, and two had a high risk of bias. The underlay technique was significantly associated with a higher surgical success rate (n = 7 RCTs, RR: 1.21 with 95% CI [1.02, 1.43], P = 0.03) and audiological success rate (n = 4 RCTs, RR: 1.31 with 95% CI [1.18, 1.44], P < 0.00001). This meta-analysis underscores the potential superiority of the underlay technique in managing tympanic membrane perforations, with significant implications for surgical and audiological outcomes. However, more investigations are still necessary to confirm this result. Supplementary Information: The online version contains supplementary material available at 10.1007/s12070-023-04425-6.

4.
PLoS One ; 19(6): e0303301, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38857266

RESUMEN

OBJECTIVE: Audio processors (AP) are the external components of hearing implants. User satisfaction with the performance and comfort of their AP is a critical factor in ensuring daily use, which leads to improved hearing outcomes. The aim of this study was to construct and validate an Arabic language translation of the APSQ for use among Arabic-speaking clinicians and patients. DESIGN: The original APSQ was translated into the Arabic language using cross-cultural adaptation measures. The final questionnaire was administered to CI users in electronic form. STUDY SAMPLE: 117 CI users (64 female) participated. A total of 179 ears were assessed. RESULTS: High levels of satisfaction with audio processors were observed among CI users. Item and scale analyses indicate that this version of the APSQ measure a homogeneous and valid construct. CONCLUSION: The Arabic version of the APSQ captures user satisfaction with hearing implant audio processors.


Asunto(s)
Implantes Cocleares , Lenguaje , Satisfacción del Paciente , Humanos , Femenino , Encuestas y Cuestionarios , Masculino , Persona de Mediana Edad , Adulto , Anciano , Traducciones , Adulto Joven
5.
Int J Pediatr Otorhinolaryngol ; 181: 111990, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38796944

RESUMEN

OBJECTIVES: The newborn hearing screening (NHS) program was globally established for early hearing loss (HL) identification and intervention. Early intervention is essential to minimize or prevent the negative consequences of HL. In Saudi Arabia, the NHS was officially implemented in 2016. Currently, its impact on the timing of cochlear implantations (CIs) in Saudi Arabia remains unclear, and information on potential hospital-related delays affecting early implantation is lacking. Thus, this study aimed to evaluate the effect of implementing the NHS on age at CI in children with prelingual deafness in a CI center in Saudi Arabia, and to evaluate the hospital timing in the CI process. METHODS: All pediatric CI users who presented for the first time to the CI committee (CIC) at a tertiary center and received their implants between 2015 and 2022 were enrolled in this study. Date of birth (DOB), date of presentation to the CI committee (DOCIC), and date of CI surgery (DOCIS) were retrospectively reviewed. RESULTS: In total, 304 CI children were included in the analysis. Approximately 55 % of the children (n = 167) were screened for HL through the NHS, whereas 45 % of the children (n = 137) were born before the launch of the NHS. Both age at the presentation to the CIC (i.e. difference between DOCIC and DOB) and age at implantation (i.e. difference between DOCIS and DOB) were significantly earlier in children who were screened for HL through the NHS than those who were not screened (P < 0.0001). The time difference between the DOCIC and DOCIS was not significantly different between the screened and unscreened children (P > 0.05). CONCLUSION: The implementation of the NHS in the tertiary center has a significant positive effect on age at presentation to the CIC and age at implantation, but not on the actual CI surgery. Further research is needed to reduce the hospital delays before the actual surgery in order to increase the likelihood of children receiving implantation early in their life.


Asunto(s)
Implantación Coclear , Pruebas Auditivas , Tamizaje Neonatal , Humanos , Recién Nacido , Implantación Coclear/estadística & datos numéricos , Femenino , Estudios Retrospectivos , Masculino , Arabia Saudita , Lactante , Preescolar , Sordera/cirugía , Sordera/diagnóstico , Pérdida Auditiva/diagnóstico , Tiempo de Tratamiento/estadística & datos numéricos , Factores de Tiempo
6.
Sci Rep ; 14(1): 9194, 2024 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649424

RESUMEN

This retrospective study examined mastoid defects resulting from cochlear implant (CI) surgery and their potential for spontaneous regrowth across different age groups. Spontaneous closure of mastoid defects has been observed in certain CI patients during revision surgery or through post-operative temporal bone computer tomography (TB-CT). The analysis encompassed 123 CI recipients, comprising 81.3% children and 18.7% adults, who underwent post-operative TB-CT scans. Using image adjustment software, the study measured mastoid defect areas and found a significant reduction in children's defects between the initial and subsequent scans. Notably, mastoid defect areas differed significantly between children and adults at both time points. Furthermore, the analysis revealed significant correlations between mastoid defect areas and the age at implantation as well as the time elapsed since the CI surgery and the first CT scan. This study provides valuable insights for evaluating CI patients scheduled for revision surgery by assessing potential surgical challenges and duration. Furthermore, it may have a pivotal role in evaluating patients who experience postauricular swelling subsequent to CI surgery.


Asunto(s)
Implantación Coclear , Apófisis Mastoides , Tomografía Computarizada por Rayos X , Humanos , Apófisis Mastoides/cirugía , Apófisis Mastoides/diagnóstico por imagen , Implantación Coclear/métodos , Masculino , Niño , Femenino , Preescolar , Adulto , Estudios Retrospectivos , Persona de Mediana Edad , Adolescente , Anciano , Lactante , Adulto Joven , Implantes Cocleares , Reoperación
7.
J Clin Med ; 13(11)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38893010

RESUMEN

Objectives: The growing adoption of cochlear implants (CIs) necessitates understanding the factors influencing long-term performance and improved outcomes. This work investigated the long-term effect of early activation of CIs on electrode impedance in a large sample of CI users at different time points. Methods: A retrospective study on 915 ears from CI patients who were implanted between 2015 and 2020. According to their CI audio processor activation time, the patients were categorized into early activation (activated 1 day after surgery, n = 481) and classical activation (activated 4 weeks after surgery, n = 434) groups. Then, the impact of the activation times on the electrode impedance values, along the electrode array contacts, at different time points up to two years was studied and analyzed. Results: The early activation group demonstrated lower impedance values across all the electrode array sections compared to the classical activation at 1 month, 1 year, and 2 years post-implantation. At 1 month, early activation was associated with a reduction of 0.34 kΩ, 0.46 kΩ, and 0.37 kΩ in the apical, middle, and basal sections, respectively. These differences persisted at subsequent intervals. Conclusions: Early activation leads to sustained reductions in the electrode impedance compared to classical activation (CA), suggesting that earlier activation might positively affect long-term CI outcomes.

8.
Otol Neurotol ; 45(2): 107-113, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38206059

RESUMEN

BACKGROUND: Anatomy-based fitting (ABF) is a new research area in the field of cochlear implants (CIs). Despite the reported benefits and acceptable levels of ABF among CI recipients, some limitations remain, like the postoperative computed tomography (CT) scan, which is preferred for confirming electrode array insertion. OBJECTIVE: This study aimed to investigate the feasibility of using plain film radiography (X-ray) for postoperative electrode detection and for building ABF as an alternative to CT. METHODS: A total of 53 ears with CI were studied. All cases had routine post-insertion X-rays in the cochlear view and additionally underwent postoperative CT. The insertion angles and center frequencies measured by two independent observers were compared for each imaging modality. The angular insertion depth and center frequencies resulting from the X-ray and CT scans were then compared. RESULTS: No significant differences were observed between the X-ray- and CT-measured angles for the electrode contacts. Radiographic measurements between the two readers showed an almost perfect (≥0.8) or substantial (0.71) intraclass correlation coefficient along the electrode contacts. X-ray images showed a mean difference of 4.7 degrees from CT. The mean semitone deviation of the central frequency between the CT and X-ray images was 0.6. CONCLUSIONS: X-ray imaging provides a valid and easy-to-perform alternative to CT imaging, with less radiation exposure and lower costs. The radiographs showed excellent concordance with the CT-measured angular insertion depth and consequently with the central frequency for most electrode contacts. Therefore, plain X-ray could be a viable alternative in building ABF for the CI recipients.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Rayos X , Radiografía , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS