Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38881496

RESUMEN

BACKGROUND: Artificial intelligence, particularly deep learning (DL), has immense potential to improve the interpretation of transthoracic echocardiography (TTE). Mitral regurgitation (MR) is the most common valvular heart disease and presents unique challenges for DL, including the integration of multiple video-level assessments into a final study-level classification. METHODS: A novel DL system was developed to intake complete TTEs, identify color MR Doppler videos, and determine MR severity on a 4-step ordinal scale (none/trace, mild, moderate, and severe) using the reading cardiologist as a reference standard. This DL system was tested in internal and external test sets with performance assessed by agreement with the reading cardiologist, weighted κ, and area under the receiver-operating characteristic curve for binary classification of both moderate or greater and severe MR. In addition to the primary 4-step model, a 6-step MR assessment model was studied with the addition of the intermediate MR classes of mild-moderate and moderate-severe with performance assessed by both exact agreement and ±1 step agreement with the clinical MR interpretation. RESULTS: A total of 61 689 TTEs were split into train (n=43 811), validation (n=8891), and internal test (n=8987) sets with an additional external test set of 8208 TTEs. The model had high performance in MR classification in internal (exact accuracy, 82%; κ=0.84; area under the receiver-operating characteristic curve, 0.98 for moderate/severe MR) and external test sets (exact accuracy, 79%; κ=0.80; area under the receiver-operating characteristic curve, 0.98 for moderate or greater MR). Most (63% internal and 66% external) misclassification disagreements were between none/trace and mild MR. MR classification accuracy was slightly higher using multiple TTE views (accuracy, 82%) than with only apical 4-chamber views (accuracy, 80%). In subset analyses, the model was accurate in the classification of both primary and secondary MR with slightly lower performance in cases of eccentric MR. In the analysis of the 6-step classification system, the exact accuracy was 80% and 76% with a ±1 step agreement of 99% and 98% in the internal and external test set, respectively. CONCLUSIONS: This end-to-end DL system can intake entire echocardiogram studies to accurately classify MR severity and may be useful in helping clinicians refine MR assessments.

2.
Eur Heart J ; 45(11): 876-894, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38426859

RESUMEN

Transcatheter tricuspid valve interventions (TTVI) are emerging as alternatives to surgery in high-risk patients with isolated or concomitant tricuspid regurgitation. The development of new minimally invasive solutions potentially more adapted to this largely undertreated population of patients, has fuelled the interest for the tricuspid valve. Growing evidence and new concepts have contributed to revise obsolete and misleading perceptions around the right side of the heart. New definitions, classifications, and a better understanding of the disease pathophysiology and phenotypes, as well as their associated patient journeys have profoundly and durably changed the landscape of tricuspid disease. A number of registries and a recent randomized controlled pivotal trial provide preliminary guidance for decision-making. TTVI seem to be very safe and effective in selected patients, although clinical benefits beyond improved quality of life remain to be demonstrated. Even if more efforts are needed, increased disease awareness is gaining momentum in the community and supports the establishment of dedicated expert valve centres. This review is summarizing the achievements in the field and provides perspectives for a less invasive management of a no-more-forgotten disease.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Calidad de Vida , Cateterismo Cardíaco/efectos adversos , Insuficiencia de la Válvula Tricúspide/etiología , Resultado del Tratamiento
3.
Eur Heart J ; 45(11): 895-911, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38441886

RESUMEN

Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia
4.
Echocardiography ; 41(1): e15719, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38126261

RESUMEN

AIM: To test the feasibility and accuracy of a new attention-based deep learning (DL) method for right ventricular (RV) quantification using 2D echocardiography (2DE) with cardiac magnetic resonance imaging (CMR) as reference. METHODS AND RESULTS: We retrospectively analyzed images from 50 adult patients (median age 51, interquartile range 32-62 42% women) who had undergone CMR within 1 month of 2DE. RV planimetry of the myocardial border was performed in end-diastole (ED) and end-systole (ES) for eight standardized 2DE RV views with calculation of areas. The DL model comprised a Feature Tokenizer module and a stack of Transformer layers. Age, gender and calculated areas were used as inputs, and the output was RV volume in ED/ES. The dataset was randomly split into training, validation and testing subsets (35, 5 and 10 patients respectively). Mean RVEDV, RVESV and RV ejection fraction (EF) were 163 ± 70 mL, 82 ± 42 mL and 51% ± 8% respectively without differences among the subsets. The proposed method achieved good prediction of RV volumes (R2  = .953, absolute percentage error [APE] = 9.75% ± 6.23%) and RVEF (APE = 7.24% ± 4.55%). Per CMR, there was one patient with RV dilatation and three with RV dysfunction in the testing dataset. The DL model detected RV dilatation in 1/1 case and RV dysfunction in 4/3 cases. CONCLUSIONS: An attention-based DL method for 2DE RV quantification showed feasibility and promising accuracy. The method requires validation in larger cohorts with wider range of RV size and function. Further research will focus on the reduction of the number of required 2DE to make the method clinically applicable.


Asunto(s)
Aprendizaje Profundo , Disfunción Ventricular Derecha , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ecocardiografía , Estudios de Factibilidad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Derecha
5.
Curr Cardiol Rep ; 26(6): 459-474, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38884853

RESUMEN

PURPOSE OF REVIEW: Patients with severe tricuspid regurgitation (TR) are at risk for significant morbidity and mortality. Transcatheter tricuspid valve interventions (TTVI) may offer patients less invasive treatment alternatives to surgery. This review evaluates the most common class of device currently used worldwide to treat TR, tricuspid transcatheter edge-to-edge repair (T-TEER) and orthotopic transcatheter tricuspid valve replacement (TTVR), both of which are now approved in the USA and Europe. RECENT FINDINGS: The first pivotal randomized clinical trial, TRILUMINATE, demonstrated that T-TEER can safely reduce TR and is associated with improved health status outcomes. However, results of this trial have raised questions about whether this device can provide sufficient TR reduction to impact clinical outcomes. Orthotopic TTVR has recently gained attention with initial data suggesting near-complete TR elimination. The current review examines the technical features and anatomic limitations of the most commonly used devices for T-TEER and orthotopic TTVR, discusses the current clinical data for these devices, and offers a theoretical construct for device selection.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentación , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
9.
Ann Cardiothorac Surg ; 13(3): 211-223, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38841078

RESUMEN

Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of a normally functioning prosthetic valve is too small in relation to the patient's body size. The effect of PPM on outcomes and valve durability have gained credibility, making this an important possibly preventable risk factor. Transcatheter aortic valve replacement (TAVR) generally has a lower incidence of PPM than surgical aortic valve replacement (SAVR). Current surgical literature and randomized trials show an association between severe PPM and mortality in patients with SAVR but there is less evidence for an association with TAVR. Differences in the incidence of PPM may be related to the methods and cutoffs for measuring mismatch. This review will discuss the current state of field and propose standardization of measurement methods which may more accurately risk stratify patients.

10.
J Cardiovasc Comput Tomogr ; 18(3): 259-266, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38383226

RESUMEN

AIM: To identify anatomical computed tomography (CT) predictors of procedural and clinical outcomes in patients undergoing tricuspid transcatheter edge-to-edge repair (T-TEER). METHODS AND RESULTS: Consecutive patients undergoing T-TEER between March 2018 to December 2022 who had cardiac CT prior to the procedure were included. CT scans were automatically analyzed using a dedicated software that employs deep learning techniques to provide precise anatomical measurements and volumetric calculations. Technical success was defined as successful placement of at least one implant in the planned anatomic location without single leaflet device attachment. Procedural success was defined as tricuspid regurgitation reduction to moderate or less. Procedural complexity was assessed by measuring the fluoroscopy time. The clinical endpoint was a composite of death, heart failure hospitalization, or tricuspid re-intervention throughout two years. A total of 33 patients (63.6% male) were included. Procedural success was achieved in 22 patients (66.7%). Shorter end-systolic (ES) height between the inferior vena cava (IVC) and tricuspid annulus (TA) (r â€‹= â€‹- 0.398, p â€‹= â€‹0.044) and longer ES RV length (r â€‹= â€‹0.551, p â€‹= â€‹0.006) correlated with higher procedural complexity. ES RV length was independently associated with lower technical(adjusted Odds ratio [OR] 0.812 [95% CI 0.665-0.991], p â€‹= â€‹0.040) and procedural success (adjusted OR 0.766, CI [0.591-0.992], p â€‹= â€‹0.043). Patients with ES right ventricular (RV) length of >77.4 â€‹mm had a four-fold increased risk of experiencing the composite clinical endpoint compared to patients with ES RV length ≤77.4 â€‹mm (HR â€‹= â€‹3.964 [95% CI, 1.018-15.434]; p â€‹= â€‹0,034]). CONCLUSION: CT-derived RV length and IVC-to-TA height may be helpful to identify patients at increased risk for procedural complexity and adverse outcomes when undergoing T-TEER. CT provides valuable information for preprocedural decision-making and device selection.


Asunto(s)
Cateterismo Cardíaco , Valor Predictivo de las Pruebas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Anciano , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Resultado del Tratamiento , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Estudios Retrospectivos , Anciano de 80 o más Años , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Recuperación de la Función , Tomografía Computarizada por Rayos X , Medición de Riesgo , Persona de Mediana Edad
11.
HERD ; : 19375867241237501, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38512990

RESUMEN

OBJECTIVES, PURPOSE, OR AIM: The study aimed to decrease noise levels in the ICU, anticipated to have adverse effects on both patients and staff, by implementing enhancements in acoustic design. BACKGROUND: Recognizing ICU noise as a significant disruptor of sleep and a potential hindrance to patient recovery, this study was conducted at a 40-bed ICU in Fiona Stanley Hospital in Perth, Australia. METHODS: A comprehensive mixed-methods approach was employed, encompassing surveys, site analysis, and acoustic measurements. Survey data highlighted the importance of patient sleep quality, emphasizing the negative impact of noise on work performance, patient connection, and job satisfaction. Room acoustics analysis revealed noise levels ranging from 60 to 90 dB(A) in the presence of patients, surpassing sleep disruption criteria. RESULTS: Utilizing an iterative 3D design modeling process, the study simulated significant acoustic treatment upgrades. The design integrated effective acoustic treatments within patient rooms, aiming to reduce noise levels and minimize transmission to adjacent areas. Rigorous evaluation using industry-standard acoustic software highlights the design's efficacy in reducing noise transmission in particular. Additionally, cost implications were examined, comparing standard ICU construction with acoustically treated options for new construction and refurbishment projects. CONCLUSIONS: This study provides valuable insights into design-based solutions for addressing noise-related challenges in the ICU. While the focus is on improving the acoustic environment by reducing noise levels and minimizing transmission to adjacent areas. It is important to clarify that direct measurements of patient outcomes were not conducted. The potential impact of these solutions on health outcomes, particularly sleep quality, remains a crucial aspect for consideration.

12.
J Am Coll Cardiol ; 84(2): 195-212, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38960514

RESUMEN

Heart failure with preserved ejection fraction (HFpEF) is associated with high morbidity and mortality. Important risk factors for the development of HFpEF are similar to risk factors for the progression of tricuspid regurgitation (TR), and both conditions frequently coexist and thus is a distinct phenotype or a marker for advanced HF. Many patients with severe, symptomatic atrial secondary TR have been enrolled in current transcatheter device trials, and may represent patients at an advanced stage of HFpEF. Management of HFpEF thus may affect the pathophysiology of TR, and the physiologic changes that occur following transcatheter treatment of TR, may also impact symptoms and outcomes in patients with HFpEF. This review discusses these issues and suggests possible management strategies for these patients.


Asunto(s)
Insuficiencia Cardíaca , Volumen Sistólico , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Volumen Sistólico/fisiología
13.
Eur Heart J Case Rep ; 8(8): ytae261, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39113778

RESUMEN

Background: Limited data exist on strain changes after transcatheter aortic valve implantation (TAVI) in patients with aortic regurgitation (AR). Case summary: Three patients with AR undergoing TAVI showed an initial reduction in global longitudinal strain (GLS), followed by sustained GLS improvement within the first year. Discussion: Findings align with those of surgically treated patients with AR. There is a possible superiority of GLS to left ventricular end-diastolic diameter ratio in assessing patients with severe volume overload.

14.
JACC Cardiovasc Interv ; 17(7): 837-858, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599687

RESUMEN

Severe tricuspid regurgitation (TR) is a progressive condition associated with substantial morbidity, poor quality of life, and increased mortality. Patients with TR commonly have coexisting conditions including congestive heart failure, pulmonary hypertension, chronic lung disease, atrial fibrillation, and cardiovascular implantable electronic devices, which can increase the complexity of medical and surgical TR management. As such, the optimal timing of referral for isolated tricuspid valve (TV) intervention is undefined, and TV surgery has been associated with elevated risk of morbidity and mortality. More recently, an unprecedented growth in TR treatment options, namely the development of a wide range of transcatheter TV interventions (TTVI) is stimulating increased interest and referral for TV intervention across the entire medical community. However, there are no stepwise algorithms for the optimal management of symptomatic severe TR before TTVI. This article reviews the contemporary assessment and management of TR with addition of a medical framework to optimize TR before referral for TTVI.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Calidad de Vida , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
15.
J Thorac Dis ; 16(1): 26-39, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38410607

RESUMEN

Background: Systolic anterior motion (SAM) of the mitral valve can result in mitral regurgitation (MR) and adverse outcomes in patients with obstructive hypertrophic cardiomyopathy (HCM). However, the mechanism and characteristics of MR severity mediated by SAM are unresolved. This study aimed to elucidate the anatomic and hemodynamic associations of MR and the impact of septal myectomy on changes in MR severity in patients with HCM. Methods: We retrospectively reviewed patients who underwent septal myectomy with SAM and interpretable imaging between 2017-2022. Significant MR was defined as moderate or more MR. The mitral valve, papillary muscle, and left ventricular geometry were quantitatively evaluated via echocardiography and cardiac computed tomography. Results: Out of 34 patients, two groups were identified: those with preoperative significant MR (n=16) and those without significant MR (n=18). Patients with significant preoperative MR exhibited worse heart failure symptoms at baseline than those without. Following myectomy, these patients showed higher residual left ventricular outflow tract (LVOT) gradients at rest and with provocative measures than those without preoperative MR. Multivariate regression analysis revealed a significant association between the tenting area and MR severity. Additionally, the chordal cutting procedure alleviated the tenting area [2.1 (1.8-2.6) vs. 1.4 (1.2-1.6) cm2] compared to those without it. Conclusions: Our preliminary data suggested that chordal cutting with septal myectomy was associated with an improvement in the tenting area, contributing to MR severity. This procedure may serve as an effective therapy for patients with SAM and significant MR.

16.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938841

RESUMEN

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

17.
Artículo en Inglés | MEDLINE | ID: mdl-39177555

RESUMEN

BACKGROUND: A prior Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry-based analysis reported similar 1-year clinical outcomes with small (20-mm) vs large (≥23-mm) balloon-expandable valves (BEV). OBJECTIVES: The aim of this study was to describe mid-term 3-year clinical outcomes for small vs large BEV and the relationship between discharge echocardiographic mean gradient (MG) and different definitions of prothesis-patient mismatch (PPM) with clinical outcomes. METHODS: Using the TVT Registry with Centers for Medicare and Medicaid Services linkage, a propensity-matched analysis of patients receiving 20- vs ≥23-mm BEVs was performed. Spline curves and Kaplan-Meier plots with adjusted HRs determined the relationship between MG and 3-year mortality. RESULTS: In total, 316,091 patients were analyzed; after propensity matching, 8,100 pairs of each group were compared. The 20-mm BEV was associated with higher MGs compared with ≥23-mm BEVs (16.2 ± 7.2 mm Hg vs 11.8 ± 5.7 mm Hg; P < 0.0001). At 3 years, there was no difference in mortality between 20- and ≥23-mm BEVs (31.5% vs 32.5%, respectively; HR: 0.97; 95% CI: 0.90-1.05). Compared with an MG of 10 to 30 mm Hg, an MG <10 mm Hg (HR: 1.25; 95% CI:1.22-1.27) was associated with increased 3-year mortality. Measured severe PPM and predicted no PPM were associated with increased 3-year mortality (33.5% vs 32.9% vs 32.1%; P < 0.0001) and (33.5% vs 31.1% vs 30%; P < 0.0001), respectively. Low MG and severe measured PPM were associated with lower left ventricular ejection fraction (LVEF). CONCLUSIONS: Patients with small-prosthesis BEVs (20 mm) had identical 3-year survival as those with larger (≥23-mm) BEV valves. Severe measured PPM and low MG (<10 mm Hg), but not predicted severe PPM, were associated with lower LVEF and increased mortality, suggesting that LVEF is the culprit for worse outcomes.

18.
Artículo en Inglés | MEDLINE | ID: mdl-39066744

RESUMEN

BACKGROUND: New postprocessing software facilitates 3-dimensional (3D) echocardiographic determination of mitral annular (MA) and neo-left ventricular outflow tract (neo-LVOT) dimensions in patients undergoing transcatheter mitral valve replacement (TMVR). OBJECTIVES: This study aims to test the accuracy of 3D echocardiographic analysis as compared to baseline computed tomography (CT). METHODS: A total of 105 consecutive patients who underwent TMVR at 2 tertiary care centers between October 2017 and May 2023 were retrospectively included. A virtual valve was projected in both baseline CT and 3D transesophageal echocardiography (TEE) using dedicated software. MA dimensions were measured in baseline images and neo-LVOT dimensions were measured in baseline and postprocedural images. All measurements were compared to baseline CT as a reference. The predicted neo-LVOT area was correlated with postprocedural peak LVOT gradients. RESULTS: There was no significant bias in baseline neo-LVOT prediction between both imaging modalities. TEE significantly underestimated MA area, perimeter, and medial-lateral dimension compared to CT. Both modalities significantly underestimated the actual neo-LVOT area (mean bias pre/post TEE: 25.6 mm2, limit of agreement: -92.2 mm2 to 143.3 mm2; P < 0.001; mean bias pre/post CT: 28.3 mm2, limit of agreement: -65.8 mm2 to 122.4 mm2; P = 0.046), driven by neo-LVOT underestimation in the group treated with dedicated mitral valve bioprosthesis. Both CT- and TEE-predicted-neo-LVOT areas exhibited an inverse correlation with postprocedural LVOT gradients (r2 = 0.481; P < 0.001 for TEE and r2 = 0.401; P < 0.001 for CT). CONCLUSIONS: TEE-derived analysis provides comparable results with CT-derived metrics in predicting the neo-LVOT area and peak gradient after TMVR.

19.
Circ Cardiovasc Imaging ; 17(2): e016409, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38377238

RESUMEN

Innovations in cardiac imaging have fundamentally advanced the understanding and treatment of cardiovascular disease. These advances in noninvasive cardiac imaging have also expanded the role of the cardiac imager and dramatically increased the demand for imagers who are cross-trained in multiple modalities. However, we hypothesize that there is significant variation in the availability of cardiac imaging expertise and a disparity in the adoption of advanced imaging technologies across the United States. To evaluate this, we have brought together the leaders of cardiovascular imaging societies, imaging trainees, as well as collaborated with national imaging accreditation commissions and imaging certification boards to assess the state of cardiac imaging and the diversity of the imaging workforce in the United States. Aggregate data confirm the presence of critical gaps, such as limited access to imaging and imaging expertise in rural communities, as well as disparities in the imaging workforce, notably among women and underrepresented minorities. Based on these results, we have proposed solutions to promote and maintain a robust and diverse community of cardiac imagers and improve equity and accessibility for cardiac imaging technologies.


Asunto(s)
Enfermedades Cardiovasculares , Grupos Minoritarios , Humanos , Femenino , Estados Unidos , Recursos Humanos , Imagen Multimodal , Técnicas de Imagen Cardíaca
20.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866455

RESUMEN

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA