RESUMEN
BACKGROUND: Monitoring of transfusion-transmissible infections in the blood supply is essential for blood safety, as the donor population is not static, and changes in policy, donor behavior, or other factors could increase the risk of recipient infection. We assessed patterns of recently acquired HIV infection in US blood donors, including before and after the implementation of the 12-month deferral for men who have sex with men (MSM). STUDY DESIGN AND METHODS: A large convenience sample of donations from donors testing HIV-1 nucleic acid testing (NAT) and serology-reactive were further tested with the Sedia HIV-1 Limiting Antigen enzyme immunoassay. Samples were analyzed across available demographic and donation data to provide an assessment of recently acquired HIV infection in US blood donors from 2010 to 2018. RESULTS: Overall, 317 of 1154 (27.5%; 95% confidence interval, 24.9%-30.1%) donations from HIV NAT and serology-reactive donors had recently acquired HIV infection. There was no evidence of change in the percentages of recent HIV infection by year over the study period, either in all donors or in male donors, including after the MSM policy change. In multivariable logistic regression analysis, donors aged 24 years or younger were over 2.7 times more likely and repeat donors 2.2 times more likely to have recently acquired HIV infection compared to donors aged 55 years or older and first-time donors, respectively. CONCLUSION: Patterns of recently acquired HIV infection varied by demographics but not over time. These findings suggest no impact of the MSM policy change on recently acquired HIV infection in US blood donors.
Asunto(s)
Donantes de Sangre , Seguridad de la Sangre , Selección de Donante , Infecciones por VIH , VIH-1 , Minorías Sexuales y de Género , Adolescente , Adulto , Femenino , Infecciones por VIH/sangre , Infecciones por VIH/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estados Unidos/epidemiologíaRESUMEN
BACKGROUND: The major aims of the RBC-Omics study were to evaluate the genomic and metabolomic determinants of spontaneous and stress-induced hemolysis during RBC storage. This study was unique in scale and design to allow evaluation of RBC donations from a sufficient number of donors across the spectrum of race, ethnicity, sex, and donation intensity. Study procedures were carefully piloted, optimized, and controlled to enable high-quality data collection. METHODS: The enrollment goal of 14,000 RBC donors across four centers, with characterization of RBC hemolysis across two testing laboratories, required rigorous piloting and optimization and establishment of a quality assurance (QA) and quality control (QC) program. Optimization of WBC elution from leukoreduction (LR) filters, development and validation of small-volume transfer bags, impact of manufacturing and sample-handling procedures on hemolysis parameters, and testing consistency across laboratories and technicians and over time were part of this quality assurance/quality control program. RESULTS: LR filter elution procedures were optimized for obtaining DNA for analysis. Significant differences between standard and pediatric storage bags led to use of an alternative LR-RBC transfer bag. The impact of sample preparation and freezing methods on metabolomics analyses was evaluated. Proficiency testing monitored and documented testing consistency across laboratories and technicians. CONCLUSION: Piloting and optimization, and establishment of a robust quality assurance/quality control program documented process consistency throughout the study and was essential in executing this large-scale multicenter study. This program supports the validity of the RBC-Omics study results and a sample repository that can be used in future studies.
Asunto(s)
Conservación de la Sangre/métodos , Hemólisis/fisiología , Adenosina Trifosfato/metabolismo , Eritrocitos/citología , Eritrocitos/metabolismo , Humanos , Control de CalidadRESUMEN
Background: Human immunodeficiency virus (HIV) antibodies are generated and maintained by ongoing systemic expression of HIV antigen. We investigated whether HIV antibody responses as measured by high-throughput quantitative and qualitative assays could be used to indirectly measure persistent HIV replication in individuals receiving antiretroviral therapy (ART). Methods: HIV antibody responses were measured over time in the presence or absence of suppressive ART and were compared to the HIV reservoir size and expression of antiviral restriction factors. Results: Among untreated individuals, including both elite controllers (ie, persons with a viral load of ≤40 copies/mL) and noncontrollers, antibody parameters were stable over time and correlated with the individual viral load. Viral suppression with ART led to a progressive decline in antibody responses after treatment induction that persisted for 5-7 years. Higher levels of HIV antibodies during suppressive therapy were associated with later initiation of ART after infection, with higher DNA and cell-associated RNA levels, and with lower expression of multiple anti-HIV host restriction factors. Discussion: These findings suggest that declining antibody levels during ART reflect lower levels of antigen production and/or viral replication in the persistent HIV reservoir. Results of relatively inexpensive and quantitative HIV antibody assays may be useful indirect markers that enable efficient monitoring of the viral reservoir and suppression during functional-cure interventions.
Asunto(s)
Anticuerpos Anti-VIH/sangre , Infecciones por VIH/sangre , VIH-1/fisiología , Replicación Viral , Terapia Antirretroviral Altamente Activa , Biomarcadores/sangre , Perfilación de la Expresión Génica , Antígenos VIH/sangre , Infecciones por VIH/tratamiento farmacológico , VIH-1/genética , Humanos , Estudios Longitudinales , ARN Viral/aislamiento & purificación , Manejo de Especímenes , Carga ViralRESUMEN
BACKGROUND: Notwithstanding 1 documented case of HIV-1 cure following allogeneic stem cell transplantation (allo-SCT), several subsequent cases of allo-SCT in HIV-1 positive individuals have failed to cure HIV-1 infection. The aim of our study was to describe changes in the HIV reservoir in a single chronically HIV-infected patient on suppressive antiretroviral therapy who underwent allo-SCT for treatment of acute lymphoblastic leukemia. METHODS AND FINDINGS: We prospectively collected peripheral blood mononuclear cells (PBMCs) by leukapheresis from a 55-year-old man with chronic HIV infection before and after allo-SCT to measure the size of the HIV-1 reservoir and characterize viral phylogeny and phenotypic changes in immune cells. At day 784 post-transplant, when HIV-1 was undetectable by multiple measures-including PCR measurements of both total and integrated HIV-1 DNA, replication-competent virus measurement by large cell input quantitative viral outgrowth assay, and in situ hybridization of colon tissue-the patient consented to an analytic treatment interruption (ATI) with frequent clinical monitoring. He remained aviremic off antiretroviral therapy until ATI day 288, when a low-level virus rebound of 60 HIV-1 copies/ml occurred, which increased to 1,640 HIV-1 copies/ml 5 days later, prompting reinitiation of ART. Rebounding plasma HIV-1 sequences were phylogenetically distinct from proviral HIV-1 DNA detected in circulating PBMCs before transplantation. The main limitations of this study are the insensitivity of reservoir measurements, and the fact that it describes a single case. CONCLUSIONS: allo-SCT led to a significant reduction in the size of the HIV-1 reservoir and a >9-month-long ART-free remission from HIV-1 replication. Phylogenetic analyses suggest that the origin of rebound virus was distinct from the viruses identified pre-transplant in the PBMCs.
Asunto(s)
Infecciones por VIH/terapia , Carga Viral/efectos de los fármacos , Antirretrovirales/uso terapéutico , VIH/genética , Infecciones por VIH/virología , VIH-1/genética , Humanos , Leucocitos Mononucleares , Masculino , Persona de Mediana Edad , Filogenia , Leucemia-Linfoma Linfoblástico de Células Precursoras/terapia , Trasplante de Células Madre/métodos , Carga Viral/fisiologíaRESUMEN
The HIV epidemic is still one of the world's most serious public health challenges, affecting about 38 million people worldwide, especially in sub-Saharan African and Southeast Asian countries. In recent years, tests have been developed to discriminate recent from long-term infection in HIV-infected populations, and these tools can help identify new outbreaks and networks of transmission and target prevention and treatment plans. New rapid tests for recent infection are being deployed in point-of-care settings; however, quality assurance programs need to be implemented to ensure consistency and reliability of the results. We have developed a dried tube specimen (DTS) stabilized with disaccharide trehalose as a quality control reagent for rapid recency testing that can be stored unrefrigerated prior to reconstitution at temperatures up to 37°C for up to 12 weeks. Analysis of 10 trehalose-stabilized DTSs showed that they maintained the same recency classification in all of the samples stored at 4°C and 37°C up to 12 weeks and at 56°C for 2 weeks, while the DTSs prepared without trehalose changed their classification from long-term to recent or recent to negative after storage at 37°C for 12 weeks. Development of DTS quality control reagents will facilitate proficiency and training programs, particularly in settings without cold chain capability in field environments. IMPORTANCE Implementation of stabilized dried tube specimens (DTSs) for quality control and training would facilitate HIV recency programs, especially in point-of-care settings without cold chain availability. This study shows that addition of the disaccharide trehalose to DTSs prior to drying the samples increased stability of the samples across a range of temperatures. This finding provides an affordable way to increase the availability of these key reagents for quality control in resource-constrained settings.
Asunto(s)
Infecciones por VIH , Trehalosa , Humanos , Reproducibilidad de los Resultados , Control de Calidad , Desecación , Infecciones por VIH/diagnósticoRESUMEN
Myalgic encephalomyelitis, or chronic fatigue syndrome (ME/CFS) is a serious disease whose cause has yet to be identified. Objective markers of the disease are also not well understood and would serve as important tools in diagnosis and management. One potential biomarker or transmitter of immune signals in ME/CFS is the extracellular vesicle (EV) compartment. These small, membrane bound particles have been shown to play a key role in intercellular signaling. Our laboratory has focused on methods of detection of EVS in clinical samples. In this study we explored whether the prevalence of EVs in the plasma of participants with mild or severe ME/CFS differed from the plasma of healthy control participants. By staining for multiple cell surface molecules, plasma EVs could be fingerprinted as to their cell of origin. Our study revealed a significant correlation between severe ME/CSF and levels of EVs bearing the B cell marker CD19 and the platelet marker CD41a, though these changes were not significant after correction for multiple comparisons. These findings point to potential dysregulation of B cell and platelet activation or homeostasis in ME/CFS, which warrants validation in a replication cohort and further exploration of potential mechanisms underlying the association.
Asunto(s)
Vesículas Extracelulares , Síndrome de Fatiga Crónica , Linfocitos B/metabolismo , Biomarcadores , Estudios de Cohortes , Vesículas Extracelulares/metabolismo , Síndrome de Fatiga Crónica/diagnóstico , HumanosRESUMEN
BACKGROUND: In people with HIV on antiretroviral therapy (ART), the relationship between HIV-specific immune responses and measures of HIV persistence is uncertain. METHODS: We evaluated 101 individuals on suppressive ART in the AIDS Clinical Trials Group A5321 cohort. Cell-associated (CA) HIV DNA and RNA levels and HIV antibody concentrations and avidity to Env/p24 were measured longitudinally at years 1, 4, and 6-15 after ART initiation. Plasma HIV RNA by single copy assay and T-cell responses (IFN-γ ELISPOT) against multiple HIV antigens were measured at the last time point. RESULTS: HIV antibody levels declined significantly with increasing time on ART (19%/year between year 1 and 4). HIV antibody levels correlated with T-cell responses to HIV Pol (r = 0.28, P = 0.014) and to Nef/Tat/Rev (r = 0.34; P = 0.002). HIV antibody and T-cell responses were positively associated with HIV DNA levels; for example, at the last time point (median 7 years on ART), r = 0.35 for antibody levels and HIV DNA (P < 0.001); r = 0.23 for Nef/Tat/Rev-specific T-cell responses and HIV DNA (P = 0.03). Neither antibody nor T-cell responses correlated with cell-associated HIV RNA or plasma RNA by single copy assay. CONCLUSIONS: In individuals on long-term ART, HIV-specific antibody and T-cell responses correlate with each other and with HIV DNA levels. The positive correlation between HIV immune responses and HIV DNA implies that the immune system is sensing, but not clearing, infected cells, perhaps because of immune dysfunction. Measuring immune responses to HIV antigens may provide insight into the impact of reservoir-reducing strategies.
Asunto(s)
Fármacos Anti-VIH/uso terapéutico , Linfocitos T CD4-Positivos/fisiología , Linfocitos T CD8-positivos/fisiología , ADN Viral/sangre , Anticuerpos Anti-VIH/sangre , Infecciones por VIH/sangre , Linfocitos T CD4-Positivos/efectos de los fármacos , Linfocitos T CD8-positivos/efectos de los fármacos , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/inmunología , HumanosRESUMEN
Laboratory assays for identifying recent HIV-1 infections are widely used for estimating incidence in cross-sectional population-level surveys in global HIV-1surveillance. Adequate assay and laboratory performance are required to ensure accurate incidence estimates. The NIAID-supported External Quality Assurance Program Oversight Laboratory (EQAPOL) established a proficiency testing program for the most widely-used incidence assay, the HIV-1 Limiting Antigen Avidity EIA (LAg), with US Centers for Disease Control and Prevention (CDC)-approved kits manufactured by Sedia Biosciences Corporation and Maxim Biomedical. The objective of this program is to monitor the performance of participating laboratories. Four rounds of blinded external proficiency (EP) panels were distributed to up to twenty testing sites (7 North American, 5 African, 4 Asian, 2 South American and 2 European). These panels consisted of ten plasma samples: three blinded well-characterized HIV-1-seropositive samples that were included as replicates and an HIV-negative control. The seropositive samples spanned the dynamic range of the assay and are categorized as either recent or long-term infection. Participating sites performed the assay according to manufacturers' instructions and completed an online survey to gather information on kit manufacturer, lot of kit used, laboratory procedures and the experience of technicians. On average, fifteen sites participated in each round of testing, with an average of four sites testing with only the Maxim assay, seven testing with only the Sedia assay and five sites utilizing both assays. Overall, the Sedia and Maxim assays yielded similar infection status categorization across the laboratories; however, for most of the nine HIV+ samples tested, there were significant differences in the optical density readouts, ODn (N = 8) and OD (N = 7), between LAg kit manufacturers (p < 0.05 based on mixed effects models. The EQAPOL LAg program is important for monitoring laboratory performance as well as detecting variations between manufacturers of HIV-1incidence assays.
Asunto(s)
Antígenos Virales/inmunología , Antígenos VIH/inmunología , Infecciones por VIH/inmunología , Seropositividad para VIH/inmunología , VIH-1/inmunología , Ensayos de Aptitud de Laboratorios/métodos , Pruebas Serológicas/métodos , Estudios Transversales , Humanos , Incidencia , Laboratorios , Carga Viral/inmunologíaRESUMEN
BACKGROUND: Two manufacturers, Maxim Biomedical and Sedia Biosciences Corporation, supply CDC-approved versions of the HIV-1 Limiting Antigen Avidity EIA (LAg) for detecting 'recent' HIV infection in cross-sectional incidence estimation. This study assesses and compares the performance of the two assays for incidence surveillance. METHODS: We ran both assays on a panel of 2,500 well-characterized HIV-1-infected specimens. We analysed concordance of assay results, assessed reproducibility using repeat testing and estimated mean durations of recent infection (MDRIs) and false-recent rates (FRRs) for a range of normalized optical density (ODn) thresholds, alone and in combination with viral load thresholds. We defined three hypothetical surveillance scenarios, similar to the Kenyan and South African epidemics, and a concentrated epidemic. These scenarios allowed us to evaluate the precision of incidence estimates obtained by means of various recent infection testing algorithms (RITAs) based on each of the two assays. RESULTS: The Maxim assay produced lower ODn values than the Sedia assay on average, largely as a result of higher calibrator readings (mean OD of 0.749 vs. 0.643), with correlation of normalized readings lower (R2 = 0.908 vs. R2 = 0.938). Reproducibility on blinded control specimens was slightly better for Maxim. The MDRI of a Maxim-based algorithm at the 'standard' threshold (ODn ≤1.5 & VL >1,000) was 201 days (95% CI: 180,223) and for Sedia 171 (152,191). The difference Differences in MDRI were estimated at 32.7 (22.9,42.8) and 30.9 days (21.7,40.7) for the two algorithms, respectively. Commensurately, the Maxim algorithm had a higher FRR in treatment-naive subjects (1.7% vs. 1.1%). The two assays produced similar precision of incidence estimates in the three surveillance scenarios. CONCLUSIONS: Differences between the assays can be primarily attributed to the calibrators supplied by the manufacturers. Performance for surveillance was extremely similar, although different thresholds were optimal (i.e. produced the lowest variance of incidence estimates) and at any given ODn threshold, different estimates of MDRI and FRR were obtained. The two assays cannot be treated as interchangeable: assay and algorithm-specific performance characteristic estimates must be used for survey planning and incidence estimation.
Asunto(s)
Epidemias , Antígenos VIH/fisiología , Infecciones por VIH/epidemiología , VIH-1/inmunología , Algoritmos , Estudios Transversales , Femenino , Antígenos VIH/inmunología , Infecciones por VIH/inmunología , Humanos , Incidencia , Kenia , Vigilancia de la Población , Carga ViralRESUMEN
Accurate HIV-1 incidence estimation is critical to the success of HIV-1 prevention strategies. Current assays are limited by high false recent rates (FRRs) in certain populations and a short mean duration of recent infection (MDRI). Dynamic early HIV-1 antibody response kinetics were harnessed to identify biomarkers for improved incidence assays. We conducted retrospective analyses on circulating antibodies from known recent and longstanding infections and evaluated binding and avidity measurements of Env and non-Env antigens and multiple antibody forms (i.e., IgG, IgA, IgG3, IgG4, dIgA, and IgM) in a diverse panel of 164 HIV-1-infected participants (clades A, B, C). Discriminant function analysis identified an optimal set of measurements that were subsequently evaluated in a 324-specimen blinded biomarker validation panel. These biomarkers included clade C gp140 IgG3, transmitted/founder clade C gp140 IgG4 avidity, clade B gp140 IgG4 avidity, and gp41 immunodominant region IgG avidity. MDRI was estimated at 215 day or alternatively, 267 days. FRRs in untreated and treated subjects were 5.0% and 3.6%, respectively. Thus, computational analysis of dynamic HIV-1 antibody isotype and antigen interactions during infection enabled design of a promising HIV-1 recency assay for improved cross-sectional incidence estimation.