Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Semin Thorac Cardiovasc Surg ; 31(2): 175-180, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30291887

RESUMEN

The axillary artery seems an interesting alternative in nonfemoral transaortic valve replacement (TAVR) patients. This study describes our experience with this technique and its short-term follow-up results. This is a retrospective single center study. All axillary TAVR performed in our department between 2015 and 2017 were included in the study. Mean follow-up was 13.2 ± 9.5 months. All reporting was done according to the VARC-2 criteria. During the period covered, 43 patients had an axillary TAVR. Most patients were men (62.7%), had a mean age of 83.9 ± 5.3 years and presented with EuroSCORE I, II, and STS score of 27.9 ± 13.5%, 5.6 ± 4.9%, and 7.7 ± 4.05%, respectively. Vascular access was successful in all patients with a higher frequency of left approach (69.7%, n = 30). Both Medtronic CoreValve 37.2% (n = 16) and Edwards Sapien3 62.8% (n = 27) valves were used. An apical Certitude delivery system was preferentially used (24/27) in the latter group. There were no reported instances of valve migration or need for a second valve implantation. A single case (2.3%) of arterial vascular complication was reported. Central neurologic morbidity was 2.3%. No patient experienced brachial plexus injury. A pacemaker was implanted in 18.6% of cases (n = 8), with no significant difference between the 2 valves patient groups (S3 14.8% vs CV 25%, P 0.67). The 30-day mortality was 6.9% (n = 3) and 1-year survival was 86% [95% CI 72.6, 93.4]. Axillary TAVR is associated with acceptable morbidity, mortality, and leads to satisfactory short-term clinical outcomes. It has the potential to become the main alternative access route in nonfemoral TAVR patients.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Arteria Axilar , Calcinosis/cirugía , Cateterismo Periférico/métodos , Enfermedad Arterial Periférica/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Arteria Axilar/diagnóstico por imagen , Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/mortalidad , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Punciones , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
2.
Am Heart J ; 153(4): 641-8, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17383306

RESUMEN

BACKGROUND: Left ventricular remodeling (LVR) is a strong predictor of cardiovascular events after myocardial infarction (MI). Although several factors have been shown to influence LVR, interindividual variability exists. Some studies have suggested that gene polymorphisms may be associated with LVR, but these studies were limited by either a retrospective design or the inclusion of limited patient numbers. The present study was designed to prospectively assess the impact of gene polymorphisms on LVR. METHODS: We included 266 patients with inaugural anterior MI. Systematic echocardiographic follow-ups were performed at 3 months and at 1 year after MI. The polymorphisms were selected using a candidate gene approach based on LVR pathophysiology. We analyzed 14 polymorphisms in 3 different systems: the renin-angiotensin-aldosterone system (ACE I/D, RAT1 1166A/C, angiotensinogen M235T, CYP11B2 -344C/T), the adrenergic system (beta1AR Ser49Gly, beta1AR Gly389Arg, beta2AR Gly16Arg, beta2AR Gln27Glu, beta2AR Thr164Ile, alpha2cAR Del322-325), and the metalloproteinase (MMP) system (-1607 1G/2G MMP-1, -1306 C/T MMP-2, -1171 5A/6A MMP-3, -1562 C/T MMP-9). RESULTS: Left ventricular remodeling was documented by a progressive increase in end-diastolic volume from 56.5 +/- 14.9 mL/m2 at baseline to 62.8 +/- 18.8 mL/m2 at 1 year (P < .0001). End-diastolic volume at baseline, 3 months, or 1 year did not differ significantly among genotypes for any polymorphism. The change in end-diastolic volume from baseline to 1 year was also similar among genotypes for all polymorphisms. CONCLUSIONS: Left ventricular remodeling after MI is not associated with common polymorphisms in the renin-angiotensin-aldosterone, adrenergic, or MMP systems.


Asunto(s)
Metaloproteinasas de la Matriz/genética , Infarto del Miocardio/genética , Polimorfismo Genético , Receptores Adrenérgicos/genética , Sistema Renina-Angiotensina/genética , Remodelación Ventricular/genética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA