Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Cardiovasc Electrophysiol ; 25(8): 882-888, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24724625

RESUMEN

BACKGROUND: The left ventricular (LV) lead local electrogram (EGM) delay from the beginning of the QRS complex (QLV) is considered a strong predictor of response to cardiac resynchronization therapy. We have developed a method for fast epicardial QLV mapping during video-thoracoscopic surgery to guide LV lead placement. METHODS: A three-port, video-thoracoscopic approach was used for LV free wall epicardial mapping and lead implantation. A decapolar electrophysiological catheter was introduced through one port and systematically attached to multiple accessible LV sites. The pacing lead was targeted to the site with maximum QLV. The LV free wall activation pattern was analyzed in 16 pre-specified anatomical segments. RESULTS: We implanted LV leads in 13 patients with LBBB or IVCD. The procedural and mapping times were 142 ± 39 minutes and 20 ± 9 minutes, respectively. A total of 15.0 ± 2.2 LV segments were mappable with variable spatial distribution of QLV-optimum. The QLV ratio (QLV/QRSd) at the optimum segment was significantly higher (by 0.17 ± 0.08, p < 0.00001) as compared to an empirical midventricular lateral segment. The LV lead was implanted at the optimum segment in 11 patients (at an adjacent segment in 2 patients) achieving a QLV ratio of 0.82 ± 0.09 (range 0.63-0.93) and 99.5 ± 0.6% match with intraprocedural mapping. CONCLUSION: Video-thoracoscopic LV lead implantation can be effectively and safely guided by epicardial QLV mapping. This strategy was highly successful in targeting the selected LV segment and resulted in significantly higher QLV ratios compared to an empirical midventricular lateral segment.


Asunto(s)
Bloqueo de Rama/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Mapeo Epicárdico , Ventrículos Cardíacos/cirugía , Pericardio/fisiopatología , Cirugía Torácica Asistida por Video , Anciano , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Factores de Tiempo , Función Ventricular Izquierda , Presión Ventricular
2.
BMC Cardiovasc Disord ; 12: 34, 2012 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-22607487

RESUMEN

BACKGROUND: Considerable proportion of patients does not respond to the cardiac resynchronization therapy (CRT). This study investigated clinical relevance of left ventricular electrode local electrogram delay from the beginning of QRS (QLV). We hypothesized that longer QLV indicating more optimal lead placement in the late activated regions is associated with the higher probability of positive CRT response. METHODS: We conducted a retrospective, single-centre analysis of 161 consecutive patients with heart failure and LBBB or nonspecific intraventricular conduction delay (IVCD) treated with CRT. We routinely intend to implant the LV lead in a region with long QLV. Clinical response to CRT, left ventricular (LV) reverse remodelling (i.e. decrease in LV end-systolic diameter - LVESD ≥10%) and reduction in plasma level of NT-proBNP >30% at 12-month post-implant were the study endpoints. We analyzed association between pre-implant variables and the study endpoints. RESULTS: Clinical CRT response rate reached 58%, 84% and 92% in the lowest (≤105 ms), middle (106-130 ms) and the highest (>130 ms) QLV tertile (p < 0.0001), respectively. Longer QRS duration (p = 0.002), smaller LVESD and a non-ischemic cardiomyopathy (both p = 0.02) were also univariately associated with positive clinical CRT response. In a multivariate analysis, QLV remained the strongest predictor of clinical CRT response (p < 0.00001), followed by LVESD (p = 0.01) and etiology of LV dysfunction (p = 0.04). Comparable predictive power of QLV for LV reverse remodelling and NT-proBNP response rates was observed. CONCLUSION: LV lead position assessed by duration of the QLV interval was found the strongest independent predictor of beneficial clinical response to CRT.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Técnicas Electrofisiológicas Cardíacas , Bloqueo Cardíaco/terapia , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Distribución de Chi-Cuadrado , República Checa , Diseño de Equipo , Femenino , Bloqueo Cardíaco/sangre , Bloqueo Cardíaco/fisiopatología , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/fisiopatología , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Remodelación Ventricular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA