Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Pacing Clin Electrophysiol ; 43(10): 1199-1204, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32820823

RESUMEN

BACKGROUND: Despite descriptions of various cardiovascular manifestations in patients with coronavirus disease 2019 (COVID-19), there is a paucity of reports of new onset bradyarrhythmias, and the clinical implications of these events are unknown. METHODS: Seven patients presented with or developed severe bradyarrhythmias requiring pacing support during the course of their COVID-19 illness over a 6-week period of peak COVID-19 incidence. A retrospective review of their presentations and clinical course was performed. RESULTS: Symptomatic high-degree heart block was present on initial presentation in three of seven patients (43%), and four patients developed sinus arrest or paroxysmal high-degree atrioventricular block. No patients in this series demonstrated left ventricular systolic dysfunction or acute cardiac injury, whereas all patients had elevated inflammatory markers. In some patients, bradyarrhythmias occurred prior to the onset of respiratory symptoms. Death from complications of COVID-19 infection occurred in 57% (4/7) patients during the initial hospitalization and in 71% (5/7) patients within 3 months of presentation. CONCLUSIONS: Despite management of bradycardia with temporary (3/7) or permanent leadless pacemakers (4/7), there was a high rate of short-term morbidity and death due to complications of COVID-19. The association between new-onset bradyarrhythmias and poor outcomes may influence management strategies for acutely ill patients with COVID-19.


Asunto(s)
Bradicardia/etiología , Bradicardia/terapia , Estimulación Cardíaca Artificial/métodos , Infecciones por Coronavirus/complicaciones , Neumonía Viral/complicaciones , Anciano , Betacoronavirus , Bradicardia/mortalidad , COVID-19 , Comorbilidad , Infecciones por Coronavirus/mortalidad , Electrocardiografía , Femenino , Humanos , Masculino , Pandemias , Neumonía Viral/mortalidad , Pronóstico , Estudios Retrospectivos , SARS-CoV-2
2.
Heart Rhythm ; 19(2): 206-216, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34710561

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.


Asunto(s)
Bloqueo Atrioventricular , COVID-19 , Control de Infecciones , Complicaciones Posoperatorias , Implantación de Prótesis , SARS-CoV-2/aislamiento & purificación , Síndrome del Seno Enfermo , Anciano , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/terapia , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/terapia , Comorbilidad , Desfibriladores Implantables/estadística & datos numéricos , Femenino , Salud Global/estadística & datos numéricos , Humanos , Control de Infecciones/instrumentación , Control de Infecciones/métodos , Control de Infecciones/organización & administración , Masculino , Persona de Mediana Edad , Mortalidad , Evaluación de Resultado en la Atención de Salud , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/mortalidad , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/mortalidad , Factores de Riesgo , Síndrome del Seno Enfermo/epidemiología , Síndrome del Seno Enfermo/terapia , Encuestas y Cuestionarios
3.
Pacing Clin Electrophysiol ; 34(1): e6-8, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20345623

RESUMEN

Dual site left ventricular pacing through two left ventricular pacing leads, located in discrete vessels, significantly lowered pacing thresholds from 6 V at 1 ms and 4.25 V at 0.5 ms through the leads individually, to 0.75 V at 0.5 ms by utilizing a Y-adaptor to connect the two leads.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Electrodos Implantados , Insuficiencia Cardíaca/prevención & control , Anciano , Umbral Diferencial , Humanos , Masculino , Resultado del Tratamiento
4.
J Innov Card Rhythm Manag ; 11(9): 4219-4222, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32983590

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic has necessitated rapid implementation of innovative strategies to manage patients remotely to help reduce the risk of community and nosocomial transmission. This case demonstrates the use of an Apple Watch (Apple, Cupertino, CA, USA) to monitor for arrhythmias and QT prolongation in a patient with COVID-19 during home isolation.

5.
AACN Adv Crit Care ; 26(4): 312-9, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26484991

RESUMEN

Implantation of cardiac implantable electronic devices (CIEDs), including pacemakers, implantable cardioverter-defibrillators, and biventricular pacemakers/cardioverter-defibrillators, is becoming increasingly common with new implants now exceeding 1.5 million per year globally. As a result, health care providers in all disciplines are caring for an increasing number of patients with CIEDs. Although the risk of complications associated with implantation of CIEDs is relatively low, the sequela can be catastrophic. Management requires an understanding of an individual patient's indication for CIED implant, the steps of implant procedures, device function, and natural history of each complication.


Asunto(s)
Enfermería de Cuidados Críticos , Desfibriladores Implantables , Cardiopatías/terapia , Complicaciones Intraoperatorias , Monitoreo Fisiológico/instrumentación , Marcapaso Artificial , Complicaciones Posoperatorias , Cardiopatías/enfermería , Cardiopatías/fisiopatología , Humanos , Complicaciones Intraoperatorias/diagnóstico , Complicaciones Intraoperatorias/enfermería , Monitoreo Fisiológico/enfermería , Diagnóstico de Enfermería , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/enfermería
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA