Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circ J ; 84(1): 43-53, 2019 12 25.
Artículo en Inglés | MEDLINE | ID: mdl-31813890

RESUMEN

BACKGROUND: The incidence and short- and long-term outcomes of coronary artery perforation (CAP) are not well described.Methods and Results:We analyzed the characteristics and the short- and long-term outcomes of CAP among 243,149 patients undergoing percutaneous coronary interventions (PCI) from 2005 until 2017 in the national Swedish registry. We identified 1,008 cases of CAP with an incidence of 0.42%. Major adverse event rates were significantly higher in patients with CAP than non-CAP (P<0.001). The 1-year mortality rate was 16% vs. 5.5%, respectively, and the 12-year mortality rate was 52% vs. 34%. The restenosis rate was 5.2% vs. 3.1% and 17% vs. 9%, respectively. The target lesion revascularization rate was 4.2% vs. 2.6% and 10.5% vs. 7%. The stent thrombosis rate was numerically higher, 1.5% vs. 0.8% and 4.5 vs. 2.8%, with no stent thrombosis cases for equine pericardial stent grafts. Among the patients with tamponade a large proportion of cases occurred at the late stage (215/1,008, 21%), and most were not recognized in the cath-lab (167/215, 78%). The mortality rate for late tamponade was similar in patients suffering acute tamponade at 1 year (25.6% vs. 27%) or at 12 years (54% vs. 58%). CONCLUSIONS: CAP is associated with an early high excess in morbidity and mortality but with low risk of additional adverse events in the long term. Late tamponade is as deadly as acute tamponade.


Asunto(s)
Taponamiento Cardíaco , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea/efectos adversos , Complicaciones Cognitivas Postoperatorias/mortalidad , Sistema de Registros , Perforación Espontánea , Anciano , Anciano de 80 o más Años , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/mortalidad , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Supervivencia sin Enfermedad , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Perforación Espontánea/etiología , Perforación Espontánea/mortalidad , Tasa de Supervivencia , Suecia/epidemiología
2.
BMC Cardiovasc Disord ; 19(1): 44, 2019 02 26.
Artículo en Inglés | MEDLINE | ID: mdl-30808296

RESUMEN

BACKGROUND: The mechanically expandable Lotus Valve System is a fully repositionable and retrievable valve with an adaptive seal to minimize paravalvular leak (PVL). The aim of this study was to evaluate the short- and long-term safety and efficacy of the new device with focus on a new implantation technique to reduce the need for a permanent pacemaker (PPM) post procedure. METHODS: We performed a prospective single-center, non-randomized evaluation of the Lotus Valve System. The first 100 consecutive Lotus Valve implantations were included in the analysis. Outcome was assessed according to VARC2-criteria. Postoperative pacemaker rates were assessed using the national pacemaker registry and electronic medical records. Mortality at 30 days and 12 months were acquired from the national population registry. RESULTS: Mean age was 82.7 ± 5.6 years, mean Euroscore I was 25.3 ± 14.5%, mean STS-score was 6.5 ± 4.1% and mean aortic valve area was 0.6 ± 0.1 cm2. There were no cases of valve embolization, ectopic valve deployment or additional valve implantation. Device success according to the VARC2-criteria was 97%. The 30-day mortality rate was 3%. Two deaths occurred due to stroke and one due to a ventricular rupture. Major stroke rate was 2% and major vascular complication rate was 2%. The 12-month mortality rate was 14%. At discharge 87% of patients had no/trace PVL, 12% had mild PVL and one patient had a moderate PVL. A total of 13% received a new PPM post valve implantation. Among patients who did not have a PPM before the procedure, the PPM rate was 15.3%. CONCLUSIONS: This single-center evaluation of the Lotus Valve System demonstrated a good clinical outcome with a low mortality, in a high-risk population. Introduction of a new implantation technique resulted in lower PPM rates than previously reported without negatively affecting PVL. TRIAL REGISTRATION: Current Controlled Trials ISRCTN14952278 , retrospectively registered 06/11/2017.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Femenino , Humanos , Masculino , Marcapaso Artificial , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Suecia , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
3.
Arterioscler Thromb Vasc Biol ; 36(5): 1010-5, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26941016

RESUMEN

OBJECTIVE: In a previous exploratory analysis, intracoronary near-infrared spectroscopy (NIRS) found the majority of culprit lesions in ST-segment-elevation myocardial infarction (STEMI) to contain a maximum lipid core burden index in 4 mm (maxLCBI4mm) of >400. This initial study was limited by a small sample size, enrollment at a single center, and post hoc selection of the maxLCBI4mm ≥400 threshold. This study was designed a priori to substantiate the ability of NIRS to discriminate STEMI culprit from nonculprit segments and to confirm the performance of the maxLCBI4mm ≥400 threshold. APPROACH AND RESULTS: At 2 centers in the United States and Sweden, 75 STEMI patients underwent intracoronary NIRS imaging after establishing thrombolysis in myocardial infarction 3 flow, but before stenting. Blinded core laboratory analysis defined the culprit segment as the 10-mm segment distal to the proximal angiographic culprit margin. The remaining vessel was divided into contiguous 10-mm nonculprit segments. The maxLCBI4mm of culprit segments (median [interquartile range]: 543 [273-756]) was 4.4-fold greater than nonculprit segments (median [interquartile range]: 123 [0-307]; P<0.001). Receiver-operating characteristic analysis demonstrated that maxLCBI4mm differentiated culprit from nonculprit segments with high accuracy (c-statistic=0.83; P<0.001). A threshold maxLCBI4mm ≥400 identified STEMI culprit segments with a sensitivity of 64% and specificity of 85%. CONCLUSIONS: This study substantiates the ability of NIRS to accurately differentiate STEMI culprit from nonculprit segments and confirms that a threshold maxLCBI4mm ≥400 is detected by NIRS in the majority of STEMI culprits.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Lípidos/análisis , Placa Aterosclerótica , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Espectroscopía Infrarroja Corta , Anciano , Área Bajo la Curva , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/metabolismo , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/metabolismo , Vasos Coronarios/patología , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Michigan , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Infarto del Miocardio con Elevación del ST/metabolismo , Infarto del Miocardio con Elevación del ST/patología , Suecia , Ultrasonografía Intervencional
4.
BMC Cardiovasc Disord ; 17(1): 60, 2017 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-28196527

RESUMEN

BACKGROUND: Effects of increased adenosine dose in the assessment of fractional flow reserve (FFR) were studied in relation to FFR results, hemodynamic effects and patient discomfort. FFR require maximal hyperemia mediated by adenosine. Standard dose is 140 µg/kg/min administrated intravenously. Higher doses are commonly used in clinical practice, but an extensive comparison between standard intravenous dose and a high dose (220 µg/kg/min) has previously not been performed. METHODS: Seventy-five patients undergoing FFR received standard dose adenosine, followed by high dose adenosine. FFR, mean arterial pressure (MAP) and heart rate (HR) were analyzed. Patient discomfort measured by Visual Analogue Scale (VAS) was assessed. RESULTS: No significant difference was found between the doses in FFR value (0.85 [0.79-0.90] vs 0.85 [0.79-0.89], p = 0.24). The two doses correlated well irrespective of lesion severity (r = 0.86, slope = 0.89, p = <0.001). There were no differences in MAP or HR. Patient discomfort was more pronounced using high dose adenosine (8.0 [5.0-9.0]) versus standard dose (5.0 [2.0-7.0]), p = <0.001. CONCLUSIONS: Increased dose adenosine does not improve hyperemia and is associated with increased patient discomfort. Our findings do not support the use of high dose adenosine. TRIAL REGISTRATION: Retrospective Trial registration: Current Controlled Trials ISRCTN14618196 . Registered 15 December 2016.


Asunto(s)
Adenosina/administración & dosificación , Enfermedad de la Arteria Coronaria/fisiopatología , Reserva del Flujo Fraccional Miocárdico/efectos de los fármacos , Vasodilatación/fisiología , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Relación Dosis-Respuesta a Droga , Femenino , Estudios de Seguimiento , Humanos , Infusiones Intravenosas , Masculino , Estudios Prospectivos , Vasodilatación/efectos de los fármacos , Vasodilatadores/administración & dosificación
5.
BMC Cardiovasc Disord ; 17(1): 25, 2017 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-28086805

RESUMEN

BACKGROUND: In the evolving field of transcatheter aortic valve replacements a new generation of valves have been introduced to clinical practice. With the complexity of the TAVR procedure and the unique aspects of each TAVR device, there is a perceived risk that changing or adding a new valve in a department could lead to a worse outcome for patients, especially during the learning phase. The objective was to study the safety aspect of introducing a second generation repositionable transcatheter valve (Boston Scientific Lotus valve besides Edwards Sapien valve) in a department. METHODS: In a retrospective study, 53 patients receiving the Lotus system, and 47 patients receiving the Sapien system over a period of three years were compared for short-term outcome according to VARC-2 definitions and 1-year survival. RESULTS: Outcome in terms VARC-2 criteria for early safety and clinical efficacy, stroke rate, and survival at 30 days and at 1 year were similar. The Lotus valve had less paravalvular leakage, where 90% had none or trace aortic insufficiency as compared to only 48% for the Sapien system. CONCLUSIONS: Introduction of a new generation valve can be done with early device success and safety, and without jeopardizing the outcome for patients up to one year. We found no adverse effects by changing valve type and observed improved outcome in terms of lower PVL-rates. Both existing and new centers starting a TAVR program can benefit from the use of a new generation device.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Diseño de Equipo , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
6.
N Engl J Med ; 369(17): 1587-97, 2013 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-23991656

RESUMEN

BACKGROUND: The clinical effect of routine intracoronary thrombus aspiration before primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI) is uncertain. We aimed to evaluate whether thrombus aspiration reduces mortality. METHODS: We conducted a multicenter, prospective, randomized, controlled, open-label clinical trial, with enrollment of patients from the national comprehensive Swedish Coronary Angiography and Angioplasty Registry (SCAAR) and end points evaluated through national registries. A total of 7244 patients with STEMI undergoing PCI were randomly assigned to manual thrombus aspiration followed by PCI or to PCI only. The primary end point was all-cause mortality at 30 days. RESULTS: No patients were lost to follow-up. Death from any cause occurred in 2.8% of the patients in the thrombus-aspiration group (103 of 3621), as compared with 3.0% in the PCI-only group (110 of 3623) (hazard ratio, 0.94; 95% confidence interval [CI], 0.72 to 1.22; P=0.63). The rates of hospitalization for recurrent myocardial infarction at 30 days were 0.5% and 0.9% in the two groups, respectively (hazard ratio, 0.61; 95% CI, 0.34 to 1.07; P=0.09), and the rates of stent thrombosis were 0.2% and 0.5%, respectively (hazard ratio, 0.47; 95% CI, 0.20 to 1.02; P=0.06). There were no significant differences between the groups with respect to the rate of stroke or neurologic complications at the time of discharge (P=0.87). The results were consistent across all major prespecified subgroups, including subgroups defined according to thrombus burden and coronary flow before PCI. CONCLUSIONS: Routine thrombus aspiration before PCI as compared with PCI alone did not reduce 30-day mortality among patients with STEMI. (Funded by the Swedish Research Council and others; ClinicalTrials.gov number, NCT01093404.).


Asunto(s)
Trombosis Coronaria/terapia , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea , Trombectomía , Anciano , Terapia Combinada , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Estudios Prospectivos , Recurrencia , Succión , Trombectomía/instrumentación , Trombectomía/métodos , Tiempo de Tratamiento
7.
J Interv Cardiol ; 29(2): 155-61, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27062125

RESUMEN

OBJECTIVES: To describe the first-in-man experience with the ClearLumen Thrombectomy System (Walk Vascular, Irvine, CA) and report on its safety, feasibility and efficacy when used as an adjunctive therapy during primary PCI. BACKGROUND: Thrombus aspiration (TA) aims to improve microvascular perfusion but currently available devices are not optimal. METHODS: Prospective, single-centre, non-randomized, safety, and efficacy trial. Patients with acute STEMI were enrolled and the investigational device was used for thrombus aspiration. Safety was evaluated as the overall rate of device related complications while efficacy as the rate of successful device deployment and culprit vessel reperfusion. The composite endpoint based on the achievement of at least two of the following three criteria-TIMI flow 3 and/or myocardial blush grade ≥2 at completion of the case and ST-resolution >70% at 90 minutes after vessel reperfusion-was also evaluated. RESULTS: Over a 3 months period 20 patients were enrolled in the study. Culprit lesion was successfully reached with the investigational device in 19 patients (95%). The pre-specified combined endpoint was met in 16 out of 19 patients (84.2%). Three patients not meeting the combined end point had procedure related, non TA associated, adverse event. Only 2 minor procedural adverse event occurred after thrombus aspiration. CONCLUSIONS: This first-in-man experience with the ClearLumen Thrombectomy System demonstrates initial promising results on safety and efficacy when used as an adjunctive therapy during primary PCI.


Asunto(s)
Trombosis Coronaria/terapia , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/métodos , Trombectomía/instrumentación , Anciano , Terapia Combinada , Angiografía Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Trombectomía/efectos adversos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 86(6): 1014-21, 2015 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-25418711

RESUMEN

OBJECTIVE: This study was performed to assess the lipid burden of culprit lesions in non-ST-segment elevation myocardial infarction (non-STEMI) and unstable angina (UA). BACKGROUND: A recent intracoronary near-infrared spectroscopy (NIRS) study showed 85% of STEMI culprit lesions have a maximum lipid core burden index in 4-mm (maxLCBI(4mm)) ≥ 400. Whether culprit lesions in non-STEMI and UA are characterized by a similarly large lipid burden is unknown. METHODS: We studied 81 non-STEMI and UA patients undergoing culprit vessel NIRS imaging before stenting. Culprit segments were compared to all nonoverlapping 10-mm nonculprit segments for maxLCBI(4mm). Culprit segments in non-STEMI and UA were compared for the frequency of maxLCBI(4mm) ≥ 400. RESULTS: Among 81 patients (53.1% non-STEMI, 46.9% UA), non-STEMI culprit segments had a 3.4-fold greater maxLCBI(4mm) than nonculprits (448 ± 229 vs 132 ± 154, P < 0.001) and UA culprit segments had a 2.6-fold higher maxLCBI(4mm) than nonculprits (381 ± 239 vs 146 ± 175, P < 0.001). NIRS detected a maxLCBI(4mm) ≥ 400 in 63.6% of culprit segments in NSTEMI and in 38.5% of culprit segments in UA (P = 0.02). Against a background of nonculprit segments, maxLCBI(4mm) ≥ 400 had a sensitivity of 63.6% and specificity of 94.0% for culprit segments in NSTEMI and a sensitivity of 38.5% and specificity of 89.8% for culprit segments in UA. CONCLUSIONS: Large lipid cores similar to those recently detected by NIRS at STEMI culprit sites were frequently observed at culprit sites in patients with non-STEMI and UA. These findings support ongoing prospective trials designed to determine if NIRS can provide site-specific prediction of future acute coronary events.


Asunto(s)
Angina Inestable/diagnóstico , Enfermedad de la Arteria Coronaria/diagnóstico , Electrocardiografía/métodos , Infarto del Miocardio/diagnóstico , Placa Aterosclerótica/diagnóstico , Espectroscopía Infrarroja Corta/métodos , Adulto , Anciano , Angina Inestable/terapia , Angioplastia Coronaria con Balón/métodos , Estudios de Cohortes , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/terapia , Placa Aterosclerótica/terapia , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Suecia
9.
BMC Cardiovasc Disord ; 14: 189, 2014 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-25516485

RESUMEN

BACKGROUND: Despite advances in anti-platelet treatments, there still exists an early increase in both ischemic as well as bleeding events following primary PCI in patients with ST-elevation myocardial infarction (STEMI). Platelet inhibition data of different anti-platelet treatments in the acute phase of a myocardial infarction might offer some insight into these problems. The aim of this study was to evaluate the pharmacodynamic profile of 5 different anti-platelet treatments in the acute phase of STEMI in patients undergoing primary PCI. METHODS: A total of 223 STEMI patients undergoing primary PCI were prospectively included. Patients received either pre-hospital clopidogrel only, pre-hospital clopidogrel followed by prasugrel switch in the cath lab, prasugrel treatment only, pre-hospital clopidogrel followed by ticagrelor switch in the cath lab or pre-hospital ticagrelor only. Platelet reactivity was measured serially using vasodilator-stimulated phosphoprotein (VASP). RESULTS: Patients receiving pre-hospital clopidogrel followed by prasugrel switch showed similar platelet inhibition data as patients receiving prasugrel only, with more than 90% being good responders the day after PCI. Average time from prasugrel administration to a VASP value of <50% was 1.5 hours. In patients receiving pre-hospital ticagrelor, 50% were good responders at completion of PCI and average time to a VASP-value of <50% was 2.3 hours. Only 32% of patients receiving clopidogrel only were responders the day after PCI. CONCLUSIONS: Switching from an upstream bolus dose of clopidogrel to prasugrel at the time of PCI, appeared as a safe and feasible option with no tendency for overshoot or attenuation of platelet inhibition. Pre-hospital administration of ticagrelor was associated with a 50% good responder rate at completion of PCI.


Asunto(s)
Plaquetas/efectos de los fármacos , Infarto del Miocardio/tratamiento farmacológico , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/farmacología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Adenosina/efectos adversos , Adenosina/análogos & derivados , Adenosina/farmacología , Adenosina/uso terapéutico , Anciano , Protocolos Clínicos , Clopidogrel , Esquema de Medicación , Electrocardiografía , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Piperazinas/efectos adversos , Piperazinas/farmacología , Piperazinas/uso terapéutico , Inhibidores de Agregación Plaquetaria/efectos adversos , Clorhidrato de Prasugrel , Estudios Prospectivos , Tiofenos/efectos adversos , Tiofenos/farmacología , Tiofenos/uso terapéutico , Ticagrelor , Ticlopidina/efectos adversos , Ticlopidina/análogos & derivados , Ticlopidina/farmacología , Ticlopidina/uso terapéutico
10.
J Heart Valve Dis ; 22(3): 433-5, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-24151773

RESUMEN

Increased life expectancy and improvement in clinical outcome following surgery has led to an increasing number of elderly patients with a history of prior aortic valve replacement (AVR). As a consequence, a considerable number of patients may require reintervention due to a dysfunctional bioprosthesis with structural valve deterioration (SVD). Transcatheter aortic valve implantation (TAVI) has become an established surgical alternative in patients with aortic stenosis and severe comorbidities. For those patients requiring reoperation, the 'valve-in-valve' concept has been described. Here, the case is reported of a patient with a very small Sorin Soprano 18 bioprosthesis with SVD who underwent a reintervention with the transapical valve-in-valve technique. The implantation was uneventful, with no residual paravalvular leakage and a low mean transprosthetic gradient. The valve-in-valve procedure may represent a feasible alternative for redo AVR in patients with a very small, structurally deteriorated bioprosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Monitoreo Intraoperatorio/métodos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Falla de Prótesis , Reoperación/métodos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
11.
Scand Cardiovasc J ; 47 Suppl 62: 1-10, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23941732

RESUMEN

OBJECTIVES: The Swedish Web-system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies (SWEDEHEART) collects data to support the improvement of care for heart disease. DESIGN: SWEDEHEART collects on-line data from consecutive patients treated at any coronary care unit n = (74), followed for secondary prevention, undergoing any coronary angiography, percutaneous coronary intervention, percutaneous valve or cardiac surgery. The registry is governed by an independent steering committee, the software is developed by Uppsala Clinical Research Center and it is funded by The Swedish national health care provider independent of industry support. Approximately 80,000 patients per year enter the database which consists of more than 3 million patients. RESULTS: Base-line, procedural, complications and discharge data consists of several hundred variables. The data quality is secured by monitoring. Outcomes are validated by linkage to other registries such as the National Cause of Death Register, the National Patient Registry, and the National Registry of Drug prescriptions. Thanks to the unique social security number provided to all citizens follow-up is complete. The 2011 outcomes with special emphasis on patients more than 80 years of age are presented. CONCLUSION: SWEDEHEART is a unique complete national registry for heart disease.


Asunto(s)
Servicio de Cardiología en Hospital , Unidades de Cuidados Coronarios , Cardiopatías/terapia , Evaluación de Procesos y Resultados en Atención de Salud , Mejoramiento de la Calidad , Calidad de la Atención de Salud , Sistema de Registros , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos , Servicio de Cardiología en Hospital/normas , Niño , Preescolar , Angiografía Coronaria , Unidades de Cuidados Coronarios/normas , Femenino , Cardiopatías/diagnóstico , Cardiopatías/mortalidad , Humanos , Lactante , Recién Nacido , Masculino , Registro Médico Coordinado , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud/normas , Intervención Coronaria Percutánea , Mejoramiento de la Calidad/normas , Calidad de la Atención de Salud/normas , Prevención Secundaria , Suecia/epidemiología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
12.
BMC Cardiovasc Disord ; 11: 30, 2011 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-21663688

RESUMEN

BACKGROUND: To elucidate the mechanism by which local delivery of 3-morpholino-sydnonimine (SIN-1) affects intimal hyperplasia after percutaneous transluminal coronary angioplasty (PTCA). METHODS: Porcine coronary arteries were treated with PTCA and immediately afterwards locally treated for 5 minutes, with a selective cytosolic guanylate cyclase inhibitor, 1 H-(1,2,4)oxadiazole(4,3-alpha)quinoxaline-1-one (ODQ) + SIN-1 or only SIN-1 using a drug delivery-balloon. Arteries were angiographically depicted, morphologically evaluated and analyzed after one and eight weeks for actin, myosin and intermediate filaments (IF) and nitric oxide synthase (NOS) contents. RESULTS: Luminal diameter after PCI in arteries treated with SIN-1 alone and corrected for age-growth was significantly larger as compared to ODQ + SIN-1 or to controls (p < 0.01). IF/actin ratio after one week in SIN-1 treated segments was not different compared to untreated segments, but was significantly reduced compared to ODQ + SIN-1 treated vessels (p < 0.05). Expression of endothelial NADPH diaphorase activity was significantly lower in untreated segments and in SIN-1 treated segments compared to controls and SIN-1 + ODQ treated arteries (p < 0.01). Restenosis index (p < 0.01) and intimal hyperplasia (p < 0.01) were significantly reduced while the residual lumen was increased (p < 0.01) in SIN-1 segments compared to controls and ODQ + SIN-1 treated vessels. CONCLUSIONS: After PTCA local delivery of high concentrations of the NO donor SIN-1 for 5 minutes inhibited injury induced neointimal hyperplasia. This favorable effect was abolished by inhibition of guanylyl cyclase indicating mediation of a cyclic guanosine 3',5'-monophosphate (cGMP)-dependent pathway. The momentary events at the time of injury play crucial role in the ensuring development of intimal hyperplasia.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Reestenosis Coronaria/prevención & control , Vasos Coronarios/efectos de los fármacos , GMP Cíclico/metabolismo , Molsidomina/análogos & derivados , Donantes de Óxido Nítrico/farmacología , Óxido Nítrico/metabolismo , Túnica Íntima/efectos de los fármacos , Actinas/metabolismo , Análisis de Varianza , Animales , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/metabolismo , Vasos Coronarios/metabolismo , Vasos Coronarios/patología , Electroforesis en Gel de Poliacrilamida , Inhibidores Enzimáticos/farmacología , Guanilato Ciclasa/antagonistas & inhibidores , Guanilato Ciclasa/metabolismo , Hiperplasia , Filamentos Intermedios/metabolismo , Molsidomina/farmacología , Miosinas/metabolismo , NAD(P)H Deshidrogenasa (Quinona)/metabolismo , NADP/metabolismo , Óxido Nítrico Sintasa/metabolismo , Oxadiazoles/farmacología , Quinoxalinas/farmacología , Transducción de Señal/efectos de los fármacos , Sus scrofa , Factores de Tiempo , Túnica Íntima/metabolismo , Túnica Íntima/patología
13.
BMC Cardiovasc Disord ; 11: 73, 2011 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-22182425

RESUMEN

BACKGROUND: Mechanical chest compressions (CCs) have been shown capable of maintaining circulation in humans suffering cardiac arrest for extensive periods of time. Reports have documented a visually normalized coronary blood flow during angiography in such cases (TIMI III flow), but it has never been actually measured. Only indirect measurements of the coronary circulation during cardiac arrest with on-going mechanical CCs have been performed previously through measurement of the coronary perfusion pressure (CPP). In this study our aim was to correlate average peak coronary flow velocity (APV) to CPP during mechanical CCs. METHODS: In a closed chest porcine model, cardiac arrest was established through electrically induced ventricular fibrillation (VF) in eleven pigs. After one minute, mechanical chest compressions were initiated and then maintained for 10 minutes upon which the pigs were defibrillated. Measurements of coronary blood flow in the left anterior descending artery were made at baseline and during VF with a catheter based Doppler flow fire measuring APV. Furthermore measurements of central (thoracic) venous and arterial pressures were also made in order to calculate the theoretical CPP. RESULTS: Average peak coronary flow velocity was significantly higher compared to baseline during mechanical chests compressions and this was observed during the entire period of mechanical chest compressions (12 - 39% above baseline). The APV slowly declined during the 10 min period of mechanical chest compressions, but was still higher than baseline at the end of mechanical chest compressions. CPP was simultaneously maintained at > 20 mmHg during the 10 minute episode of cardiac arrest. CONCLUSION: Our study showed good correlation between CPP and APV which was highly significant, during cardiac arrest with on-going mechanical CCs in a closed chest porcine model. In addition APV was even higher during mechanical CCs compared to baseline. Mechanical CCs can, at minimum, re-establish coronary blood flow in non-diseased coronary arteries during cardiac arrest.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Presión Sanguínea/fisiología , Circulación Coronaria/fisiología , Paro Cardíaco/fisiopatología , Masaje Cardíaco , Animales , Ecocardiografía Doppler , Modelos Animales , Porcinos
14.
EuroIntervention ; 14(16): 1660-1667, 2019 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-30375337

RESUMEN

AIMS: Covered stents are mostly used for coronary perforations with a high risk of early adverse events; however, their long-term outcome is unknown. The aim of this study was to elucidate the short- and long-term outcome of patients treated with covered stents compared to all other stented patients. METHODS AND RESULTS: The Swedish national registries from 2005-2017 disclosed 265 patients who had received 366 covered stents. Their outcomes were compared to all other stented patients (197,948) who had received 320,784 stents. Compared to regular stents, covered stents showed significant differences (p<0.001) in the short and long term in relation to in-stent restenosis (ISR), target lesion revascularisation (TLR), re-infarction (MI), re-PCI and mortality, the rates of which were all higher. The higher mortality was concentrated within the first month, as a landmark analysis at that time point, adjusted for age and procedural indication, demonstrated no future difference in mortality (HR 1.02 [0.78-1.33], p=0.877). Stent thrombosis (ST) within one year was reported to be higher in covered stents than in other stents. However, no ST was reported in equine pericardial covered stents. CONCLUSIONS: This observational study including the entire Swedish population shows that patients receiving covered stents have a significantly higher risk of all adverse events. Reassuringly, in the long term, mortality appears to be similar to that in other stented patients.


Asunto(s)
Reestenosis Coronaria , Intervención Coronaria Percutánea , Stents , Animales , Angiografía Coronaria , Caballos , Humanos , Sistema de Registros , Factores de Riesgo , Suecia , Resultado del Tratamiento
15.
Circulation ; 113(6): 851-5, 2006 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-16461812

RESUMEN

BACKGROUND: Mitral annuloplasty is the most common surgical procedure performed for ischemic mitral regurgitation (MR). Surgical mitral annuloplasty is limited by morbidity, mortality, and MR recurrence. We evaluated the safety and feasibility of a transvenous catheter-delivered implantable device to provide a percutaneous alternative to surgical mitral annuloplasty. METHODS AND RESULTS: Five patients with chronic ischemic MR underwent percutaneous transvenous implantation of an annuloplasty device in the coronary sinus. Implantation was successful in 4 patients. Baseline MR in the entire group was grade 3.0+/-0.7 and was reduced to grade 1.6+/-1.1 at the last postimplantation visit when the device was intact or the last postprocedural visit in the patient in whom the device was not successfully implanted. Separation of the bridge section of the device occurred in 3 of 4 implanted devices and was detected at 28 to 81 days after implantation. There were no postprocedural device-related complications. CONCLUSIONS: Percutaneous implantation of a device intended to remodel the mitral annulus is feasible. Initial experience suggests a possible favorable effect on MR. Percutaneous transvenous mitral annuloplasty warrants further evaluation as a less invasive alternative to surgical annuloplasty.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/terapia , Anciano , Falla de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/patología , Isquemia Miocárdica , Resultado del Tratamiento
16.
BMC Cardiovasc Disord ; 7: 5, 2007 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-17324251

RESUMEN

BACKGROUND: In experimentally induced myocardial infarction, mild hypothermia (33-35 degrees C) is beneficial if applied prior to ischemia or reperfusion. Hypothermia, when applied after reperfusion seems to confer little or no benefit. The mechanism by which hypothermia exerts its cell-protective effect during cardiac ischemia remains unclear. It has been hypothesized that hypothermia reduces the reperfusion damage; the additional damage incurred upon the myocardium during reperfusion. Reperfusion results in a massive increase in blood flow, reactive hyperemia, which may contribute to reperfusion damage. We postulated that hypothermia could attenuate the post-ischemic reactive hyperemia. METHODS: Sixteen 25-30 kg pigs, in a closed chest model, were anesthetized and temperature was established in all pigs at 37 degrees C using an intravascular cooling catheter. The 16 pigs were then randomized to hypothermia (34 degrees C) or control (37 degrees C). The left main coronary artery was then catheterized with a PCI guiding catheter. A Doppler flow wire was placed in the mid part of the LAD and a PCI balloon was then positioned proximal to the Doppler wire but distal to the first diagonal branch. The LAD was then occluded for ten minutes in all pigs. Coronary blood flow was measured before, during and after ischemia/reperfusion. RESULTS: The peak flow seen during post-ischemic reactive hyperemia (during the first minutes of reperfusion) was significantly reduced by 43 % (p < 0.01) in hypothermic pigs compared to controls. CONCLUSION: Mild hypothermia significantly reduces post-ischemic hyperemia in a closed chest pig model. The reduction of reactive hyperemia during reperfusion may have an impact on cardiac reperfusion injury.


Asunto(s)
Hiperemia/etiología , Hiperemia/terapia , Hipotermia Inducida/métodos , Infarto del Miocardio/complicaciones , Animales , Análisis de los Gases de la Sangre , Presión Sanguínea , Circulación Coronaria , Vasos Coronarios/patología , Modelos Animales de Enfermedad , Femenino , Frecuencia Cardíaca , Hiperemia/patología , Masculino , Daño por Reperfusión Miocárdica/etiología , Daño por Reperfusión Miocárdica/prevención & control , Tamaño de los Órganos , Distribución Aleatoria , Valores de Referencia , Sus scrofa , Resultado del Tratamiento
17.
Cardiovasc Revasc Med ; 18(8): 577-582, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29066343

RESUMEN

INTRODUCTION: Drug-eluting stents (DES) reduce the risk of restenosis after percutaneous coronary intervention. The aim of the study was to evaluate, by intravascular ultrasound (IVUS), the minimum lumen area site in the stented segment and the distribution of intimal hyperplasia in patients presenting with a DES or bare-metal stent (BMS) in-stent restenosis. METHODS: The "Nordic Intravascular Ultrasound Study (NIVUS)" study was conducted in Nordic and Baltic countries as a prospective multicenter registry. Two hundred nine patients (DES n=121 and BMS n=88) with in-stent restenosis were enrolled. RESULTS: At the minimum lumen area site in the stented segment, the stent area (5.8±2.2mm2 vs. 7.6±2.4mm2, p<0.001) and intimal hyperplasia area (2.6±2.0mm2 vs. 5.0±2.2mm2, p<0.001) were significantly lower in patients treated with DES compared to BMS. The percentage of stents that did not have a minimum stent area of at least 5.0mm2 (under expansion) was higher in DES (58.7% vs. 37.7%, p=0.008) compared to BMS. Intimal hyperplasia covered 55.4±33.3% of the stent length in the DES compared to 90.7±17.4% in the BMS group, p<0.001. Focal in-stent restenosis was more often seen in DES treated patients compared to BMS treated patients (DES n=84 (59.9%) vs. BMS n=15 (17.0%), p<0.001). CONCLUSION: Stent underexpansion was more often seen in DES than BMS in-stent restenosis. DES more often had focal in-stent restenosis with less intimal hyperplasia.


Asunto(s)
Reestenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Metales , Neointima , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Proliferación Celular , Reestenosis Coronaria/etiología , Reestenosis Coronaria/patología , Vasos Coronarios/patología , Femenino , Humanos , Hiperplasia , Letonia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Países Escandinavos y Nórdicos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional
18.
Am J Cardiol ; 120(2): 292-299, 2017 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-28535962

RESUMEN

Paravalvular leak (PVL) after transcatheter aortic valve replacement is associated with worse long-term outcomes. The Lotus Valve incorporates an innovative Adaptive Seal designed to minimize PVL. This analysis evaluated the incidence and predictors of PVL after implantation of the Lotus transcatheter aortic valve. The REPRISE II (REpositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System - Evaluation of Safety and Performance) Study With Extended Cohort enrolled 250 high-surgical risk patients with severe symptomatic aortic stenosis. Aortic regurgitation was assessed by echocardiography pre-procedure, at discharge and 30 days, by an independent core laboratory. Baseline and procedural predictors of mild or greater PVL at 30 days (or at discharge if 30-day data were not available) were determined using a multivariate regression model (n = 229). Of the 229 patients, 197 (86%) had no/trace PVL, 30 had mild, and 2 had moderate PVL; no patient had severe PVL. Significant predictors of mild/moderate PVL included device:annulus area ratio (odds ratio [OR] 0.87; 95% CI 0.83 to 0.92; p <0.001), left ventricular outflow tract calcium volume (OR 2.85; 95% CI 1.44 to 5.63; p = 0.003), and annulus area (OR 0.89; 95% CI 0.82 to 0.96; p = 0.002). When the device:annulus area ratio was <1, the rate of mild/moderate PVL was 53.1% (17 of 32). The rates of mild/moderate PVL with 0% to 5%, 5% to 10%, and >10% annular oversizing by area were 17.5% (11 of 63), 2.9% (2 of 70), and 3.2% (2 of 63), respectively. Significant independent predictors of PVL included device:annulus area ratio and left ventricular outflow tract calcium volume. When the prosthetic valve was oversized by ≥5%, the rate of mild or greater PVL was only 3%. In conclusion, the overall rates of PVL with the Lotus Valve are low and predominantly related to device/annulus areas and calcium; these findings have implications for optimal device sizing.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tomografía Computarizada Multidetector/métodos , Pronóstico , Diseño de Prótesis , Falla de Prótesis , Índice de Severidad de la Enfermedad
19.
EuroIntervention ; 13(7): 796-803, 2017 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-28506942

RESUMEN

AIMS: This analysis aimed to evaluate the incidence and predictors of the need for permanent pacemaker (PPM) implantation following implantation of the repositionable and fully retrievable LOTUS Aortic Valve Replacement System. METHODS AND RESULTS: The prospective, single-arm, multicentre REPRISE II study with extended cohort enrolled 250 symptomatic, high surgical risk patients with severe aortic stenosis for transfemoral transcatheter aortic valve implantation (TAVI) with a 23 mm or 27 mm LOTUS valve. Echocardiography, computed tomography, and electrocardiography data were evaluated by independent core labs. Post TAVI, 32.0% (72/225) of pacemaker-naïve patients underwent new PPM implantation at 30 days. Most (59/72, 82%) patients were implanted for third-degree atrioventricular block, and >10% overstretch of the LVOT by area was observed in 59.7% (43/72) of PPM patients. Significant independent predictors of PPM at 30 days included baseline RBBB (odds ratio [OR] 12.7, 95% CI: 4.5, 36.2; p<0.001) and LVOT overstretch >10% (OR 3.4, 95% CI: 1.7, 6.7; p<0.001). There was a trend towards a lower 30-day PPM rate in patients with a shallower (≤5 mm) implant depth (23.9% ≤5 mm vs. 36.9% >5 mm depth from LCS; p=0.06). CONCLUSIONS: Careful attention to valve sizing and implant depth may help to reduce the rate of PPM with the LOTUS valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/instrumentación , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
20.
EuroIntervention ; 13(7): 788-795, 2017 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-28555592

RESUMEN

AIMS: The REPRISE IIE trial aimed to evaluate outcomes following transcatheter aortic valve implantation of the fully repositionable and retrievable LOTUS valve with a unique seal designed to minimise paravalvular leak (PVL). METHODS AND RESULTS: This prospective, multicentre study enrolled 250 patients with severe aortic stenosis considered high-risk for surgery by a multidisciplinary Heart Team. An independent clinical events committee adjudicated events per Valve Academic Research Consortium criteria. Mean age was 84 years; 77% were in NYHA Class III/IV. LOTUS valve implantation produced significant haemodynamic improvements at one year without valve embolisation, ectopic valve deployment, or additional valve implantation. Primary endpoints were met as the 30-day mortality rate in the extended cohort (4.4%, N=250), and mean valve gradient in the main cohort (11.5±5.2 mmHg, N=120) were below (p<0.001) their predefined performance objectives. At 30 days, disabling stroke was 2.8% and new pacemaker implantation was 28.9% in all patients and 32.0% in pacemaker-naïve patients. By one year, all-cause mortality was 11.6%, disabling stroke was 3.6%, 95% of patients alive were in NYHA Class I/II, and there was no core laboratory-adjudicated moderate/severe PVL. CONCLUSIONS: LOTUS valve implantation produced good valve haemodynamics, minimal PVL, sustained significant improvement in functional status, and good clinical outcomes one year post implant.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Bioprótesis , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Diseño de Prótesis/métodos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA